FCC ID 2AHYZGM291R5C-M1
Blood Glucose Monitoring System
by Smart Meter Corporation
Grantee Code: 2AHYZ Product Code: GM291R5CM1
Latest application date: 2022-11-16
FCC ID Device Details
| FCC ID | 2AHYZGM291R5C-M1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AHYZ |
| Product Code | GM291R5CM1 |
| Applicant Business | Smart Meter Corporation 🇺🇸 |
| Related Domains | |
| Equipment Class | Blood Glucose Monitoring System |
| Test Firm | SHENZHEN STS TEST SERVICES CO.,LTD. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 699-716 MHz | Original Equipment | 2022-11-16 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2022-11-16 | PDF 4.2 MB |
| Internal Photos | Internal Photos | 2022-11-16 | PDF 1.9 MB |
| External Photos | External Photos | 2022-11-16 | PDF 1.1 MB |
| Label | ID Label/Location Info | 2022-11-16 | PDF 119.3 KB |
| Test Setup Photos | Test Setup Photos | 2022-11-16 | PDF 409.2 KB |
| Test Report | Test Report | 2022-11-16 | PDF 4.4 MB |
| Agent Authorization | Cover Letter(s) | 2022-11-16 | PDF 29.4 KB |
| FCC Short & Long Term Confidentiality Request | Cover Letter(s) | 2022-11-16 | PDF 71 KB |
| SAR Dipole Performance Measurement Report | RF Exposure Info | 2022-11-16 | PDF 719.5 KB |
| SAR Report | RF Exposure Info | 2022-11-16 | PDF 5.7 MB |
| Block Diagram Metadata only | Block Diagram | PDF 120.9 KB | |
| SCH Metadata only | Schematics | PDF 146.9 KB | |
| Operation Description Metadata only | Operational Description | PDF 66.6 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 52.5 KB | |
| Tune up Metadata only | Parts List/Tune Up Info | PDF 87 KB |
Application Information
| Application ID | BEFeu7gfGysB9EM+5uNb7w== |
|---|---|
| Final Action Date | 2022-11-16 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0025483934 |
| Model | GM291R5C-M1 |
| Frequency Range | 699-716 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Blood Glucose Monitoring System |
| Responsible Party | Erez Pick, VP perations, erez.pick@iglucose.com |
| Technical Contact | Smart Meter Corporation, Erez.Pick@iglucose.com |
| Test Firm | Bovey Yang, SHENZHEN STS TEST SERVICES CO.,LTD., Bovey@stsapp.com |
| TCB Email | certification@micomlabs.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn is 0.33W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| BEFeu7gfGysB9EM+5uNb7w== | 2022-11-16 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application BEFeu7gfGysB9EM+5uNb7w==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 11/16/2022 Application Dated: 11/16/2022 |
| Smart Meter Corporation |
| 5501 W Waters Ave. |
| Suite 401 |
| Tampa, FL 33634 |
| Attention: Erez Pick , VP perations |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AHYZGM291R5C-M1 |
| Name of Grantee: | Smart Meter Corporation |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Blood Glucose Monitoring System |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.0 - 1910.0 | 0.2239 | 1.0 PM | 1M12G7D | |
| 24E | 1850.0 - 1910.0 | 0.2183 | 1.0 PM | 132KF7W | |
| 27 | 1710.0 - 1755.0 | 0.157 | 1.0 PM | 1M24G7D | |
| 27 | 1710.0 - 1755.0 | 0.1726 | 1.0 PM | 78K7F9W | |
| 27 | 699.0 - 716.0 | 0.2427 | 1.0 PM | 1M11W7D | |
| 27 | 699.0 - 716.0 | 0.2606 | 1.0 PM | 134KF7W |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn is 0.33W/kg. |
EAS Grant - Application BEFeu7gfGysB9EM+5uNb7w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Smart Meter Corporation 5501 W Waters Ave. Suite 401 Tampa, FL 33634 United States |
Date of Grant: 11/16/2022 Application Dated: 11/16/2022 |
| Attention: Erez Pick , VP perations |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AHYZGM291R5C-M1 |
| Name of Grantee: | Smart Meter Corporation |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Blood Glucose Monitoring System |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.0 - 1910.0 | 0.2239 | 1.0 PM | 1M12G7D | |
| 24E | 1850.0 - 1910.0 | 0.2183 | 1.0 PM | 132KF7W | |
| 27 | 1710.0 - 1755.0 | 0.157 | 1.0 PM | 1M24G7D | |
| 27 | 1710.0 - 1755.0 | 0.1726 | 1.0 PM | 78K7F9W | |
| 27 | 699.0 - 716.0 | 0.2427 | 1.0 PM | 1M11W7D | |
| 27 | 699.0 - 716.0 | 0.2606 | 1.0 PM | 134KF7W |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn is 0.33W/kg. |
| Mail To: |