OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.

ALE USA Inc. OmniAccess Stellar

Page 1 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 2 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 3 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 4 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 5 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 6 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 7 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 8 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 9 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 10 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 11 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 12 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 13 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 14 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 15 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 16 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 17 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 18 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 19 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 20 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 21 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 22 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 23 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 24 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 25 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 26 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 27 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 28 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 29 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 30 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 31 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 32 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 33 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 34 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 35 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 36 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 37 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 38 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 39 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 40 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 41 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 42 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 43 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 44 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 45 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 46 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 47 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 48 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 49 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 50 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 51 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 52 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 53 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 54 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 55 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 56 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 57 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 58 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 59 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 60 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 61 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Page 62 of OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.

FCC Test Report
Report No.: RF180615D14
FCC ID: 2AI9TOAW-AP1201H
Test Model: OAW-AP1201H
Received Date: Apr. 25, 2018
Test Date: May 4 ~ Jun. 27, 2018
Issued Date: Jul. 6, 2018
Applicant: ALE USA Inc.
Address: 26801 West Agoura Road, Calabasas, CA 91301
Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
(R.O.C.)
FCC Registration /
Designation Number: 198487 / TW2021
This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to
us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such
notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your
unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the
uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be
used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 1 / 62
Report Format Version: 6.1.1
Table of Contents
Release Control Record ............................................................................................................................... 4
Certificate of Conformity ................................................................................................................... 5
Summary of Test Results................................................................................................................... 6
2.1
2.2
Measurement Uncertainty ................................................................................................................. 6
Modification Record .......................................................................................................................... 6
General Information ........................................................................................................................... 7
3.1
3.2
3.2.1
3.3
3.4
3.4.1
3.5
General Description of EUT .............................................................................................................. 7
Description of Test Modes ................................................................................................................ 8
Test Mode Applicability and Tested Channel Detail ........................................................................... 9
Duty Cycle of Test Signal ................................................................................................................. 11
Description of Support Units ........................................................................................................... 12
Configuration of System under Test ................................................................................................ 12
General Description of Applied Standards ...................................................................................... 13
Test Types and Results .................................................................................................................... 14
4.1
4.1.1
4.1.2
4.1.3
4.1.4
4.1.5
4.1.6
4.1.7
4.2
4.2.1
4.2.2
4.2.3
4.2.4
4.2.5
4.2.6
4.2.7
4.3
4.3.1
4.3.2
4.3.3
4.3.4
4.3.5
4.3.6
4.3.7
4.4
4.4.1
4.4.2
4.4.3
4.4.4
4.4.5
4.4.6
4.4.7
4.5
4.5.1
4.5.2
4.5.3
4.5.4
4.5.5
Radiated Emission and Bandedge Measurement ........................................................................... 14
Limits of Radiated Emission and Bandedge Measurement ............................................................. 14
Test Instruments.............................................................................................................................. 15
Test Procedures .............................................................................................................................. 16
Deviation from Test Standard .......................................................................................................... 16
Test Setup ....................................................................................................................................... 17
EUT Operating Conditions .............................................................................................................. 18
Test Results .................................................................................................................................... 19
Conducted Emission Measurement ................................................................................................ 38
Limits of Conducted Emission Measurement .................................................................................. 38
Test Instruments.............................................................................................................................. 38
Test Procedures .............................................................................................................................. 39
Deviation from Test Standard .......................................................................................................... 39
Test Setup ....................................................................................................................................... 39
EUT Operating Conditions .............................................................................................................. 39
Test Results .................................................................................................................................... 40
6dB Bandwidth Measurement ......................................................................................................... 44
Limits of 6dB Bandwidth Measurement ........................................................................................... 44
Test Setup ....................................................................................................................................... 44
Test Instruments.............................................................................................................................. 44
Test Procedure ................................................................................................................................ 44
Deviation fromTest Standard ........................................................................................................... 44
EUT Operating Conditions .............................................................................................................. 44
Test Result ...................................................................................................................................... 45
Conducted Output Power Measurement ......................................................................................... 47
Limits of Conducted Output Power Measurement ........................................................................... 47
Test Setup ....................................................................................................................................... 47
Test Instruments.............................................................................................................................. 47
Test Procedures .............................................................................................................................. 47
Deviation from Test Standard .......................................................................................................... 47
EUT Operating Conditions .............................................................................................................. 47
Test Results .................................................................................................................................... 48
Power Spectral Density Measurement ............................................................................................ 49
Limits of Power Spectral Density Measurement .............................................................................. 49
Test Setup ....................................................................................................................................... 49
Test Instruments.............................................................................................................................. 49
Test Procedure ................................................................................................................................ 49
Deviation from Test Standard .......................................................................................................... 49
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 2 / 62
Report Format Version: 6.1.1
4.5.6
4.5.7
4.6
4.6.1
4.6.2
4.6.3
4.6.4
4.6.5
4.6.6
4.6.7
EUT Operating Condition ................................................................................................................ 49
Test Results .................................................................................................................................... 50
Conducted Out of Band Emission Measurement ............................................................................ 52
Limits of Conducted Out of Band Emission Measurement .............................................................. 52
Test Setup ....................................................................................................................................... 52
Test Instruments.............................................................................................................................. 52
Test Procedure ................................................................................................................................ 52
Deviation from Test Standard .......................................................................................................... 52
EUT Operating Condition ................................................................................................................ 52
Test Results .................................................................................................................................... 52
Pictures of Test Arrangements ........................................................................................................ 61
Appendix – Information on the Testing Laboratories .............................................................................. 62
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 3 / 62
Report Format Version: 6.1.1
Release Control Record
Issue No.
Description
Date Issued
RF180615D14
Original release.
Jul. 6, 2018
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 4 / 62
Report Format Version: 6.1.1
1
Certificate of Conformity
Product: OmniAccess Stellar
Brand: Alcatel-Lucent Enterprise
Test Model: OAW-AP1201H
Sample Status: Engineering sample
Applicant: ALE USA Inc.
Test Date: May 4 ~ Jun. 27, 2018
Standards: 47 CFR FCC Part 15, Subpart C (Section 15.247)
ANSI C63.10: 2013
The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.
Prepared by :
Date:
Jul. 6, 2018
Date:
Jul. 6, 2018
Annie Chang / Senior Specialist
Approved by :
Rex Lai / Associate Technical Manager
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 5 / 62
Report Format Version: 6.1.1
2
Summary of Test Results
47 CFR FCC Part 15, Subpart C (Section 15.247)
FCC
Clause
Test Item
Result
Remarks
15.207
AC Power Conducted Emission
PASS
Meet the requirement of limit.
Minimum passing margin is -3.42dB at
15.07422MHz.
15.205 /
15.209 /
15.247(d)
Radiated Emissions and Band Edge
Measurement
PASS
Meet the requirement of limit.
Minimum passing margin is -1.00dB at
2390.00MHz.
15.247(d)
Antenna Port Emission
PASS
Meet the requirement of limit.
15.247(a)(2)
6dB bandwidth
PASS
Meet the requirement of limit.
15.247(b)
Conducted power
PASS
Meet the requirement of limit.
15.247(e)
Power Spectral Density
PASS
Meet the requirement of limit.
15.203
Antenna Requirement
PASS
No antenna connector is used.
2.1
Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the
EUT as specified in CISPR 16-4-2:
Measurement
Frequency
Conducted Emissions at mains ports
150kHz ~ 30MHz
9kHz ~ 30MHz
30MHz ~ 1000MHz
1GHz ~ 6GHz
6GHz ~ 18GHz
Radiated Emissions up to 1 GHz
Radiated Emissions above 1 GHz
2.2
Expanded Uncertainty
(k=2) (±)
2.79 dB
2.38 dB
5.54 dB
4.77 dB
5.48 dB
Modification Record
There were no modifications required for compliance.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 6 / 62
Report Format Version: 6.1.1
3
3.1
General Information
General Description of EUT
Product
OmniAccess Stellar
Brand
Alcatel-Lucent Enterprise
Test Model
OAW-AP1201H
Status of EUT
Engineering sample
Power Supply Rating
48Vdc from Adapter or 55Vdc from PoE
Modulation Type
CCK, DQPSK, DBPSK for DSSS
64QAM, 16QAM, QPSK, BPSK for OFDM
Modulation Technology
DSSS,OFDM
802.11b:11/5.5/2/1Mbps
Transfer Rate
802.11g: 54/48/36/24/18/12/9/6Mbps
802.11n: up to 300Mbps
Operating Frequency
2.412 ~ 2.462GHz
Number of Channel
11 for 802.11b, 802.11g, 802.11n (20MHz)
7 for 802.11n (40MHz)
Output Power
360.229mW
Antenna Type
Antenna Connector
Printed antenna with 4dBi gain
N/A
Accessory Device
N/A
Data Cable Supplied
N/A
Note:
1. The EUT provides 2 completed transmitters and 2 receivers.
Modulation Mode
TX Function
802.11b
2TX
802.11g
2TX
802.11n (20MHz)
2TX
802.11n (40MHz)
2TX
2. The EUT uses following adapter or PoE Adapter (Support unit only):
Item
Brand
Model No.
Rating
AC I/P: 100-240V, 50-60Hz, 1A
Adapter
DELTA
ADP-30HR B
DC O/P: 48V, 0.66A
Non-shielded DC (1.5m) with one ferrite core
AC I/P: 100-240V, 50/60Hz, 0.67A
PoE Adapter Microsemi
PD-9001GR/AT/AC
DC O/P: 55V, 0.6A
3. For Radiated test, the EUT was pre-tested with the following modes:
 Operating Mode, Powered from Adapter
 Operating Mode, Powered from PoE
The worst emission level was found when the EUT tested under Operating Mode, Powered from
Adapter, therefore, only its test data was recorded in this report.
4. The above EUT information is declared by manufacturer and for more detailed features description,
please refer to the manufacturer's specifications or user's manual.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 7 / 62
Report Format Version: 6.1.1
3.2
Description of Test Modes
11 channels are provided for 802.11b, 802.11g and 802.11n (20MHz):
Channel
Frequency
Channel
Frequency
2412MHz
2442MHz
2417MHz
2447MHz
2422MHz
2452MHz
2427MHz
10
2457MHz
2432MHz
11
2462MHz
2437MHz
7 channels are provided for 802.11n (40MHz):
Channel
Frequency
Channel
Frequency
2422MHz
2442MHz
2427MHz
2447MHz
2432MHz
2452MHz
2437MHz
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 8 / 62
Report Format Version: 6.1.1
3.2.1
Test Mode Applicability and Tested Channel Detail
EUT Configure
Mode
Applicable To
Description
RE1G
RE<1G
PLC
APCM
√
√
√
√
Powered from Adapter
√
Powered from PoE
Where
RE1G: Radiated Emission above 1GHz &
Bandedge Measurement
RE<1G: Radiated Emission below 1GHz
PLC: Power Line Conducted Emission
APCM: Antenna Port Conducted Measurement
NOTE: The EUT had been pre-tested on the positioned of each 3 axis. The worst case was found when positioned on Y-plane.
NOTE: “-”means no effect.
Radiated Emission Test (Above 1GHz):
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
Following channel(s) was (were) selected for the final test as listed below.
EUT Configure
Mode
Mode
Available
Tested
Modulation
Modulation
Data Rate
Channel
Channel
Technology
Type
(Mbps)
802.11b
1 to 11
1, 6, 11
DSSS
DBPSK
802.11g
1 to 11
1, 2, 6, 10, 11
OFDM
BPSK
802.11n (20MHz)
1 to 11
1, 2, 6, 10, 11
OFDM
BPSK
6.5
802.11n (40MHz)
3 to 9
3, 4, 6, 8, 9
OFDM
BPSK
13.5
Radiated Emission Test (Below 1GHz):
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
Following channel(s) was (were) selected for the final test as listed below.
EUT Configure
Mode
Mode
802.11g
Available
Tested
Modulation
Modulation
Data Rate
Channel
Channel
Technology
Type
(Mbps)
1 to 11
OFDM
BPSK
Power Line Conducted Emission Test:
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
Following channel(s) was (were) selected for the final test as listed below.
EUT Configure
Mode
A&B
Report No.: RF180615D14
Reference No.: 180425D01
Mode
802.11g
Available
Tested
Modulation
Modulation
Data Rate
Channel
Channel
Technology
Type
(Mbps)
1 to 11
OFDM
BPSK
Page No. 9 / 62
Report Format Version: 6.1.1
Antenna Port Conducted Measurement:
This item includes all test value of each mode, but only includes spectrum plot of worst value of each
mode.
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
Following channel(s) was (were) selected for the final test as listed below.
EUT Configure
Mode
Mode
Available
Tested
Modulation
Modulation
Data Rate
Channel
Channel
Technology
Type
(Mbps)
802.11b
1 to 11
1, 6, 11
DSSS
DBPSK
802.11g
1 to 11
1, 2, 6, 10, 11
OFDM
BPSK
802.11n (20MHz)
1 to 11
1, 2, 6, 10, 11
OFDM
BPSK
6.5
802.11n (40MHz)
3 to 9
3, 4, 6, 8, 9
OFDM
BPSK
13.5
Test Condition:
Applicable To
EUT Configure Mode
Environmental Conditions
Input Power
Tested By
RE1G
22deg. C, 76%RH
120Vac, 60Hz
James Wei
RE<1G
23deg. C, 74%RH
120Vac, 60Hz
James Wei
25deg. C, 78%RH
120Vac, 60Hz
Starltaly Wu
PLC
APCM
Report No.: RF180615D14
Reference No.: 180425D01
25deg. C, 75%RH
120Vac, 60Hz
Starltaly Wu
25deg. C, 76%RH
120Vac, 60Hz
Saxon Lee
Page No. 10 / 62
Report Format Version: 6.1.1
3.3
Duty Cycle of Test Signal
If duty cycle of test signal is ≥ 98 %, duty factor is not required.
If duty cycle of test signal is < 98%, duty factor shall be considered.
802.11b: Duty cycle = 100%
802.11g: Duty cycle = 2.016/2.076 = 0.971, Duty factor = 10 * log( 1/0.971) = 0.13
802.11n (20MHz): Duty cycle = 1.881/1.938 = 0.971, Duty factor = 10 * log( 1/0.971) = 0.13
802.11n (40MHz): Duty cycle = 0.892/0.964 = 0.925, Duty factor = 10 * log( 1/0.925) = 0.34
802.11b
802.11g
802.11n (20MHz)
802.11n (40MHz)
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 11 / 62
Report Format Version: 6.1.1
3.4
Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
ID
Product
Brand
Model No.
Serial No.
FCC ID
Remarks
A.
Adapter
DELTA
ADP-30HR B
N/A
N/A
Supplied by client
B.
Notebook PC
DELL
PP27L
8SNZ12S
FCC DoC Approved
Provided by Lab
C.
PoE Adapter
Microsemi
PD-9001GR/AT/AC
N/A
N/A
Supplied by client
Note:
1. All power cords of the above support units are non-shielded (1.8m).
2. Item B acted as communication partners to transfer data.
ID
Descriptions
Qty.
Length (m)
Shielding
(Yes/No)
Cores (Qty.)
Remarks
1.
DC cable
1.5
Supplied by client
2.
LAN cable
10
Provided by Lab
3.
AC Cable
1.8
Provided by Lab
4.
LAN cable
1.5
Provided by Lab
5.
AC Cable
1.8
Provided by Lab
Note: The core(s) is(are) originally attached to the cable(s).
3.4.1
Configuration of System under Test
For Mode A:
EUT
AC Adapter (A)
DC input
LAN
120Vac
Remote site
Notebook PC (B)
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 12 / 62
Report Format Version: 6.1.1
For Mode B:
EUT
DC input
PoE Adapter (C)
LAN
120Vac
Remote site
Notebook PC (B)
3.5
General Description of Applied Standards
The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:
FCC Part 15, Subpart C (15.247)
KDB 558074 D01 DTS Meas Guidance v04
KDB 662911 D01 Multiple Transmitter Output v02r01
ANSI C63.10-2013
All test items have been performed and recorded as per the above standards.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 13 / 62
Report Format Version: 6.1.1
4
Test Types and Results
4.1
Radiated Emission and Bandedge Measurement
4.1.1
Limits of Radiated Emission and Bandedge Measurement
Radiated emissions which fall in the restricted bands must comply with the radiated emission limits
specified as below table. Other emissions shall be at least 30dB below the highest level of the desired
power:
Frequencies
(MHz)
Field Strength
(microvolts/meter)
Measurement Distance
(meters)
0.009 ~ 0.490
2400/F(kHz)
300
0.490 ~ 1.705
24000/F(kHz)
30
1.705 ~ 30.0
30
30
30 ~ 88
100
88 ~ 216
150
216 ~ 960
200
Above 960
500
NOTE:
1.
The lower limit shall apply at the transition frequencies.
2.
3.
Emission level (dBuV/m) = 20 log Emission level (uV/m).
For frequencies above 1000MHz, the field strength limits are based on average detector, however, the
peak field strength of any emission shall not exceed the maximum permitted average limits, specified
above by more than 20dB under any condition of modulation.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 14 / 62
Report Format Version: 6.1.1
4.1.2
Test Instruments
DESCRIPTION &
MODEL NO.
MANUFACTURER
HP Preamplifier
8447D
HP Preamplifier
8449B
MITEQ Preamplifier
AMF-6F-260400-33-8P
Agilent TEST RECEIVER
N9038A
Schwarzbeck Antenna
VULB 9168
Schwarzbeck Antenna
VHBA 9123
Schwarzbeck Horn
BBHA-9170
Antenna
Schwarzbeck Horn
BBHA 9120-D1
Antenna
ADT. Turn Table
TT100
ADT. Tower
AT100
Software
SUHNER RF cable
With 4dB PAD
SUHNER RF cable
With 3dB PAD
Loop Antenna EMCI
EMCO Horn Antenna
Highpass filter
Wainwright Instruments
ROHDE & SCHWARZ
Spectrum Analyzer
Anritsu
Power Sensor
Anritsu
Power Meter
CALIBRATED
DATE
Feb. 21, 2018
Feb. 22, 2018
Feb. 21, 2018
Feb. 6, 2018
CALIBRATED
UNTIL
Feb. 20, 2019
Feb. 21, 2019
Feb. 20, 2019
Feb. 5, 2019
Nov. 29, 2017
May 19, 2017
Nov. 28, 2018
May 18, 2019
212
Dec. 1, 2017
Nov. 30, 2018
D130
Dec. 1, 2017
Nov. 30, 2018
0306
0306
NA
NA
NA
NA
Radiated_V7.6.15.9.5
NA
NA
NA
SF104
CABLE-CH6
Aug. 14, 2017
Aug. 13, 2018
SF102
Cable-CH8-3.6m
Aug. 14, 2017
Aug. 13, 2018
LPA600
3115
270
00028257
Aug. 11, 2017
Nov. 30, 2017
Aug. 10, 2019
Nov. 29, 2018
WHK 3.1/18G-10SS
SN 8
NA
NA
FSV40
101042
Sep. 29, 2017
Sep. 28, 2018
MA2411B
0738404
Apr. 26, 2018
Apr. 25, 2019
ML2495A
0842014
Apr. 26, 2018
Apr. 25, 2019
SERIAL NO.
2432A03504
3008A01201
892164
MY51210129
139
480
NOTE: 1. The calibration interval of the above test instruments is 12/24 months. And the calibrations are
traceable to NML/ROC and NIST/USA.
2. The horn antenna and HP preamplifier (model: 8449B) are used only for the measurement of
emission frequency above 1GHz if tested.
3. The test was performed in Chamber No. 6.
4. The Industry Canada Reference No. IC 7450E-6.
5. Tested Date: May 4 ~ 17, 2018
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 15 / 62
Report Format Version: 6.1.1
4.1.3 Test Procedures
For Radiated emission below 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
room. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
of a variable-height antenna tower.
c. Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
measurement.
d. For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
from 0 degrees to 360 degrees to find the maximum reading.
e. The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with Maximum
Hold Mode.
NOTE:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at frequency
below 30MHz.
For Radiated emission above 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters (for 30MHz ~ 1GHz) / 1.5 meters (for above
1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
determine the position of the highest radiation.
b.
The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
of a variable-height antenna tower.
c.
The height of antenna is varied from one meter to four meters above the ground to determine the
maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
make the measurement.
d.
For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
find the maximum reading.
e.
The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
hold mode when the test frequency is below 1 GHz.
f.
The test-receiver system was set to peak and average detects function and specified bandwidth with
maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
average limit, measurement with the average detector is unnecessary.
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
Quasi-peak detection (QP) at frequency below 1GHz.
2.
The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
for Peak detection (PK) at frequency above 1GHz.
3.
The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video bandwidth is ≥ 1/T
(Duty cycle < 98%) or 10Hz (Duty cycle ≥ 98%) for Average detection (AV) at frequency above 1GHz.
4.
All modes of operation were investigated and the worst-case emissions are reported.
4.1.4
Deviation from Test Standard
No deviation.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 16 / 62
Report Format Version: 6.1.1
4.1.5
Test Setup
For Radiated emission below 30MHz
1m
EUT&
Support Units
3m
Turn Table
80cm
Ground Plane
Test Receiver
For Radiated emission 30MHz to 1GHz
Ant. Tower
EUT&
Support Units
3m
10m
1-4m
Variable
Turn Table
80cm
Ground Plane
Test Receiver
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 17 / 62
Report Format Version: 6.1.1
For Radiated emission above 1GHz
Ant. Tower
EUT&
Support Units
3m
Turn Table
1-4m
Variable
Absorber
150cm
Ground Plane
Test Receiver
For the actual test configuration, please refer to the attached file (Test Setup Photo).
4.1.6
EUT Operating Conditions
a. Connected the EUT with AC adapter placed on testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 18 / 62
Report Format Version: 6.1.1
4.1.7
Test Results
Mode A
Above 1GHz Data:
802.11b
CHANNEL
TX Channel 1
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2412.00
*2412.00
4824.00
4824.00
63.36 PK
52.95 AV
110.57 PK
107.61 AV
49.22 PK
42.36 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-10.64
-1.05
74.00
54.00
-24.78
-11.64
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.00 H
1.00 H
1.00 H
1.00 H
1.52 H
1.52 H
230
230
230
230
284
284
65.74
55.33
113.08
110.12
45.89
39.03
-2.38
-2.38
-2.51
-2.51
3.33
3.33
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2412.00
*2412.00
4824.00
4824.00
61.28 PK
52.51 AV
109.65 PK
106.72 AV
47.05 PK
41.29 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-12.72
-1.49
74.00
54.00
-26.95
-12.71
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
2.22 V
2.22 V
2.22 V
2.22 V
3.45 V
3.45 V
221
221
221
221
257
257
63.66
54.89
112.16
109.23
43.72
37.96
-2.38
-2.38
-2.51
-2.51
3.33
3.33
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 19 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 6
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2437.00
*2437.00
4874.00
4874.00
113.11 PK
109.40 AV
50.07 PK
42.94 AV
LIMIT
(dBuV/m)
74.00
54.00
MARGIN
(dB)
-23.93
-11.06
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.60 H
1.60 H
1.31 H
1.31 H
78
78
149
149
115.75
112.04
46.72
39.59
-2.64
-2.64
3.35
3.35
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2437.00
*2437.00
4874.00
4874.00
111.74 PK
108.37 AV
47.34 PK
41.45 AV
LIMIT
(dBuV/m)
74.00
54.00
MARGIN
(dB)
-26.66
-12.55
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
2.62 V
2.62 V
3.22 V
3.22 V
181
181
264
264
114.38
111.01
43.99
38.10
-2.64
-2.64
3.35
3.35
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 20 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 11
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2462.00
*2462.00
2483.50
2483.50
4924.00
4924.00
112.11 PK
108.89 AV
62.19 PK
52.92 AV
49.82 PK
42.76 AV
LIMIT
(dBuV/m)
74.00
54.00
74.00
54.00
MARGIN
(dB)
-11.81
-1.08
-24.18
-11.24
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.26 H
1.26 H
1.26 H
1.26 H
1.44 H
1.44 H
80
80
80
80
152
152
114.64
111.42
64.43
55.16
46.58
39.52
-2.53
-2.53
-2.24
-2.24
3.24
3.24
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2462.00
*2462.00
2483.50
2483.50
4924.00
4924.00
110.89 PK
107.76 AV
60.49 PK
51.25 AV
47.13 PK
41.28 AV
LIMIT
(dBuV/m)
74.00
54.00
74.00
54.00
MARGIN
(dB)
-13.51
-2.75
-26.87
-12.72
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
2.71 V
2.71 V
2.71 V
2.71 V
3.01 V
3.01 V
177
177
177
177
263
263
113.42
110.29
62.73
53.49
43.89
38.04
-2.53
-2.53
-2.24
-2.24
3.24
3.24
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 21 / 62
Report Format Version: 6.1.1
802.11g
CHANNEL
TX Channel 1
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
DETECTOR
FUNCTION
Average (AV)
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2412.00
*2412.00
4824.00
4824.00
73.00 PK
51.13 AV
112.57 PK
101.81 AV
42.91 PK
29.28 AV
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2412.00
*2412.00
4824.00
4824.00
68.49 PK
46.86 AV
107.74 PK
97.06 AV
41.60 PK
27.92 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-1.00
-2.87
74.00
54.00
-31.09
-24.72
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.13 H
1.13 H
1.13 H
1.13 H
1.12 H
1.12 H
100
100
100
100
241
241
75.38
53.51
115.08
104.32
39.58
25.95
-2.38
-2.38
-2.51
-2.51
3.33
3.33
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-5.51
-7.14
74.00
54.00
-32.40
-26.08
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.92 V
1.92 V
1.92 V
1.92 V
1.00 V
1.00 V
85
85
85
85
103
103
70.87
49.24
110.25
99.57
38.27
24.59
-2.38
-2.38
-2.51
-2.51
3.33
3.33
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 22 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 2
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2417.00
*2417.00
72.74 PK
51.48 AV
112.77 PK
102.01 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-1.26
-2.52
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.13 H
1.13 H
1.13 H
1.13 H
101
101
101
101
75.12
53.86
115.31
104.55
-2.38
-2.38
-2.54
-2.54
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2417.00
*2417.00
68.28 PK
47.20 AV
107.97 PK
97.16 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-5.72
-6.80
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.99 V
1.99 V
1.99 V
1.99 V
88
88
88
88
70.66
49.58
110.51
99.70
-2.38
-2.38
-2.54
-2.54
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 23 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 6
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2437.00
*2437.00
4874.00
4874.00
72.95 PK
52.75 AV
116.00 PK
106.63 AV
46.32 PK
33.23 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-1.05
-1.25
74.00
54.00
-27.68
-20.77
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.12 H
1.12 H
1.12 H
1.12 H
1.57 H
1.57 H
79
79
79
79
188
188
75.33
55.13
118.64
109.27
42.97
29.88
-2.38
-2.38
-2.64
-2.64
3.35
3.35
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2437.00
*2437.00
4874.00
4874.00
70.24 PK
51.44 AV
110.83 PK
100.91 AV
44.57 PK
31.48 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-3.76
-2.56
74.00
54.00
-29.43
-22.52
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.57 V
1.57 V
1.57 V
1.57 V
1.02 V
1.02 V
221
221
221
221
175
175
72.62
53.82
113.47
103.55
41.22
28.13
-2.38
-2.38
-2.64
-2.64
3.35
3.35
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 24 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 10
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2457.00
*2457.00
2483.50
2483.50
113.84 PK
103.76 AV
72.97 PK
50.34 AV
LIMIT
(dBuV/m)
74.00
54.00
MARGIN
(dB)
-1.03
-3.66
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.27 H
1.27 H
1.27 H
1.27 H
101
101
101
101
116.44
106.36
75.21
52.58
-2.60
-2.60
-2.24
-2.24
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2457.00
*2457.00
2483.50
2483.50
108.98 PK
98.82 AV
68.64 PK
47.84 AV
LIMIT
(dBuV/m)
74.00
54.00
MARGIN
(dB)
-5.36
-6.16
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.89 V
1.89 V
1.89 V
1.89 V
97
97
97
97
111.58
101.42
70.88
50.08
-2.60
-2.60
-2.24
-2.24
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 25 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 11
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2462.00
*2462.00
2483.50
2483.50
4924.00
4924.00
112.31 PK
102.30 AV
72.95 PK
48.86 AV
42.65 PK
29.12 AV
LIMIT
(dBuV/m)
74.00
54.00
74.00
54.00
MARGIN
(dB)
-1.05
-5.14
-31.35
-24.88
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.27 H
1.27 H
1.27 H
1.27 H
1.34 H
1.34 H
97
97
97
97
255
255
114.84
104.83
75.19
51.10
39.41
25.88
-2.53
-2.53
-2.24
-2.24
3.24
3.24
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2462.00
*2462.00
2483.50
2483.50
4924.00
4924.00
107.45 PK
96.69 AV
68.57 PK
46.87 AV
41.42 PK
27.76 AV
LIMIT
(dBuV/m)
74.00
54.00
74.00
54.00
MARGIN
(dB)
-5.43
-7.13
-32.58
-26.24
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.99 V
1.99 V
1.99 V
1.99 V
1.00 V
1.00 V
95
95
95
95
88
88
109.98
99.22
70.81
49.11
38.18
24.52
-2.53
-2.53
-2.24
-2.24
3.24
3.24
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 26 / 62
Report Format Version: 6.1.1
802.11n (20MHz)
CHANNEL
TX Channel 1
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
DETECTOR
FUNCTION
Average (AV)
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2412.00
*2412.00
4824.00
4824.00
72.96 PK
48.16 AV
109.49 PK
98.43 AV
42.99 PK
29.06 AV
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2412.00
*2412.00
4824.00
4824.00
69.36 PK
46.11 AV
107.68 PK
97.13 AV
41.60 PK
27.84 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-1.04
-5.84
74.00
54.00
-31.01
-24.94
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
3.44 H
3.44 H
3.44 H
3.44 H
1.88 H
1.88 H
97
97
97
97
206
206
75.34
50.54
112.00
100.94
39.66
25.73
-2.38
-2.38
-2.51
-2.51
3.33
3.33
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-4.64
-7.89
74.00
54.00
-32.40
-26.16
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.51 V
1.51 V
1.51 V
1.51 V
1.02 V
1.02 V
84
84
84
84
122
122
71.74
48.49
110.19
99.64
38.27
24.51
-2.38
-2.38
-2.51
-2.51
3.33
3.33
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 27 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 2
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2417.00
*2417.00
72.90 PK
51.83 AV
112.56 PK
102.11 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-1.10
-2.17
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.30 H
1.30 H
1.30 H
1.30 H
98
98
98
98
75.28
54.21
115.10
104.65
-2.38
-2.38
-2.54
-2.54
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2417.00
*2417.00
69.30 PK
50.43 AV
110.48 PK
101.18 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-4.70
-3.57
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.88 V
1.88 V
1.88 V
1.88 V
91
91
91
91
71.68
52.81
113.02
103.72
-2.38
-2.38
-2.54
-2.54
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 28 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 6
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2437.00
*2437.00
4874.00
4874.00
72.97 PK
50.60 AV
116.05 PK
105.03 AV
48.00 PK
33.06 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-1.03
-3.40
74.00
54.00
-26.00
-20.94
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.27 H
1.27 H
1.27 H
1.27 H
1.67 H
1.67 H
99
99
99
99
215
215
75.35
52.98
118.69
107.67
44.65
29.71
-2.38
-2.38
-2.64
-2.64
3.35
3.35
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2437.00
*2437.00
4874.00
4874.00
69.43 PK
46.17 AV
113.67 PK
103.78 AV
46.62 PK
31.88 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-4.57
-7.83
74.00
54.00
-27.38
-22.12
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.48 V
1.48 V
1.48 V
1.48 V
1.00 V
1.00 V
80
80
80
80
132
132
71.81
48.55
116.31
106.42
43.27
28.53
-2.38
-2.38
-2.64
-2.64
3.35
3.35
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 29 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 10
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2457.00
*2457.00
2483.50
2483.50
112.26 PK
101.94 AV
72.56 PK
49.16 AV
LIMIT
(dBuV/m)
74.00
54.00
MARGIN
(dB)
-1.44
-4.84
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.27 H
1.27 H
1.27 H
1.27 H
102
102
102
102
114.86
104.54
74.80
51.40
-2.60
-2.60
-2.24
-2.24
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2457.00
*2457.00
2483.50
2483.50
99.98 PK
100.61 AV
69.05 PK
46.92 AV
LIMIT
(dBuV/m)
74.00
54.00
MARGIN
(dB)
-4.95
-7.08
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.66 V
1.66 V
1.66 V
1.66 V
97
97
97
97
102.58
103.21
71.29
49.16
-2.60
-2.60
-2.24
-2.24
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 30 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 11
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2462.00
*2462.00
2483.50
2483.50
4924.00
4924.00
109.05 PK
98.34 AV
72.77 PK
46.12 AV
42.78 PK
28.85 AV
LIMIT
(dBuV/m)
74.00
54.00
74.00
54.00
MARGIN
(dB)
-1.23
-7.88
-31.22
-25.15
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.26 H
1.26 H
1.26 H
1.26 H
1.87 H
1.87 H
95
95
95
95
189
189
111.58
100.87
75.01
48.36
39.54
25.61
-2.53
-2.53
-2.24
-2.24
3.24
3.24
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2462.00
*2462.00
2483.50
2483.50
4924.00
4924.00
107.22 PK
96.95 AV
69.24 PK
44.35 AV
41.40 PK
27.66 AV
LIMIT
(dBuV/m)
74.00
54.00
74.00
54.00
MARGIN
(dB)
-4.76
-9.65
-32.60
-26.34
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.69 V
1.69 V
1.69 V
1.69 V
1.00 V
1.00 V
88
88
88
88
103
103
109.75
99.48
71.48
46.59
38.16
24.42
-2.53
-2.53
-2.24
-2.24
3.24
3.24
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 31 / 62
Report Format Version: 6.1.1
802.11n (40MHz)
CHANNEL
TX Channel 3
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
DETECTOR
FUNCTION
Average (AV)
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2422.00
*2422.00
4844.00
4844.00
72.89 PK
50.09 AV
108.42 PK
98.02 AV
44.04 PK
30.87 AV
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2422.00
*2422.00
4844.00
4844.00
67.36 PK
45.58 AV
102.87 PK
93.08 AV
41.96 PK
28.82 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-1.11
-3.91
74.00
54.00
-29.96
-23.13
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.28 H
1.28 H
1.28 H
1.28 H
2.45 H
2.45 H
98
98
98
98
111
111
75.27
52.47
110.98
100.58
40.66
27.49
-2.38
-2.38
-2.56
-2.56
3.38
3.38
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-6.64
-8.42
74.00
54.00
-32.04
-25.18
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.52 V
1.52 V
1.52 V
1.52 V
1.86 V
1.86 V
88
88
88
88
103
103
69.74
47.96
105.43
95.64
38.58
25.44
-2.38
-2.38
-2.56
-2.56
3.38
3.38
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 32 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 4
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2427.00
*2427.00
72.94 PK
52.86 AV
109.80 PK
99.62 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-1.06
-1.14
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.28 H
1.28 H
1.28 H
1.28 H
82
82
82
82
75.32
55.24
112.39
102.21
-2.38
-2.38
-2.59
-2.59
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2427.00
*2427.00
67.51 PK
46.43 AV
104.39 PK
94.69 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-6.49
-7.57
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.55 V
1.55 V
1.55 V
1.55 V
72
72
72
72
69.89
48.81
106.98
97.28
-2.38
-2.38
-2.59
-2.59
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 33 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 6
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2437.00
*2437.00
4874.00
4874.00
67.48 PK
52.93 AV
112.66 PK
102.44 AV
46.07 PK
32.23 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-6.52
-1.07
74.00
54.00
-27.93
-21.77
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.77 H
1.77 H
1.77 H
1.77 H
2.55 H
2.55 H
102
102
102
102
101
101
69.86
55.31
115.30
105.08
42.72
28.88
-2.38
-2.38
-2.64
-2.64
3.35
3.35
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
2390.00
2390.00
*2437.00
*2437.00
4874.00
4874.00
61.61 PK
48.85 AV
107.38 PK
97.53 AV
43.64 PK
30.64 AV
LIMIT
(dBuV/m)
MARGIN
(dB)
74.00
54.00
-12.39
-5.15
74.00
54.00
-30.36
-23.36
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.58 V
1.58 V
1.58 V
1.58 V
1.88 V
1.88 V
69
69
69
69
103
103
63.99
51.23
110.02
100.17
40.29
27.29
-2.38
-2.38
-2.64
-2.64
3.35
3.35
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 34 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 8
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2447.00
*2447.00
2483.50
2483.50
110.48 PK
100.07 AV
72.99 PK
52.91 AV
LIMIT
(dBuV/m)
74.00
54.00
MARGIN
(dB)
-1.01
-1.09
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.27 H
1.27 H
1.27 H
1.27 H
83
83
83
83
113.17
102.76
75.23
55.15
-2.69
-2.69
-2.24
-2.24
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2447.00
*2447.00
2483.50
2483.50
105.14 PK
94.90 AV
68.31 PK
48.18 AV
LIMIT
(dBuV/m)
74.00
54.00
MARGIN
(dB)
-5.69
-5.82
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.57 V
1.57 V
1.57 V
1.57 V
133
133
133
133
107.83
97.59
70.55
50.42
-2.69
-2.69
-2.24
-2.24
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 35 / 62
Report Format Version: 6.1.1
CHANNEL
TX Channel 9
FREQUENCY RANGE
1GHz ~ 25GHz
Peak (PK)
Average (AV)
DETECTOR
FUNCTION
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2452.00
*2452.00
2483.50
2483.50
4904.00
4904.00
106.87 PK
96.43 AV
71.61 PK
52.94 AV
43.52 PK
30.50 AV
LIMIT
(dBuV/m)
74.00
54.00
74.00
54.00
MARGIN
(dB)
-2.39
-1.06
-30.48
-23.50
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.58 H
1.58 H
1.58 H
1.58 H
2.58 H
2.58 H
99
99
99
99
129
129
109.55
99.11
73.85
55.18
40.23
27.21
-2.68
-2.68
-2.24
-2.24
3.29
3.29
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
*2452.00
*2452.00
2483.50
2483.50
4904.00
4904.00
101.60 PK
91.59 AV
65.98 PK
48.23 AV
41.71 PK
28.60 AV
LIMIT
(dBuV/m)
74.00
54.00
74.00
54.00
MARGIN
(dB)
-8.02
-5.77
-32.29
-25.40
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
1.55 V
1.55 V
1.55 V
1.55 V
1.80 V
1.80 V
135
135
135
135
100
100
104.28
94.27
68.22
50.47
38.42
25.31
-2.68
-2.68
-2.24
-2.24
3.29
3.29
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
5. " * ": Fundamental frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 36 / 62
Report Format Version: 6.1.1
Below 1GHz Data:
802.11g
CHANNEL
TX Channel 6
FREQUENCY RANGE
9kHz ~ 1GHz
DETECTOR
FUNCTION
Quasi-Peak (QP)
ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
LIMIT
(dBuV/m)
MARGIN
(dB)
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
42.95
92.71
520.38
580.72
716.18
746.93
24.62 QP
19.54 QP
30.69 QP
31.91 QP
33.64 QP
35.17 QP
40.00
43.50
46.00
46.00
46.00
46.00
-15.38
-23.96
-15.31
-14.09
-12.36
-10.83
3.11 H
2.08 H
2.24 H
2.03 H
1.46 H
3.09 H
119
94
77
84
310
301
32.11
32.06
31.25
31.23
30.59
31.43
-7.49
-12.52
-0.56
0.68
3.05
3.74
ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
NO.
FREQ.
(MHz)
EMISSION
LEVEL
(dBuV/m)
LIMIT
(dBuV/m)
MARGIN
(dB)
ANTENNA
HEIGHT
(m)
TABLE
ANGLE
(Degree)
RAW
VALUE
(dBuV)
CORRECTION
FACTOR
(dB/m)
42.92
92.66
592.70
678.15
746.93
851.30
36.70 QP
25.75 QP
33.29 QP
33.13 QP
35.91 QP
34.37 QP
40.00
43.50
46.00
46.00
46.00
46.00
-3.30
-17.75
-12.71
-12.87
-10.09
-11.63
1.03 V
1.15 V
1.86 V
1.76 V
2.04 V
2.26 V
205
266
134
82
160
240
44.19
38.28
32.14
30.69
32.17
28.99
-7.49
-12.53
1.15
2.44
3.74
5.38
REMARKS:
1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission Level – Limit value
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 37 / 62
Report Format Version: 6.1.1
4.2
4.2.1
Conducted Emission Measurement
Limits of Conducted Emission Measurement
Conducted Limit (dBuV)
Quasi-peak
Average
0.15 - 0.5
66 - 56
56 - 46
0.50 - 5.0
56
46
5.0 - 30.0
60
50
Note: 1. The lower limit shall apply at the transition frequencies.
2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50MHz.
Frequency (MHz)
4.2.2
Test Instruments
Description & Manufacturer
Model No.
Serial No.
Cal. Date
Cal. Due
ROHDE & SCHWARZ
ESR3
102413
Feb. 8, 2018
Feb. 7, 2019
TEST RECEIVER
ROHDE & SCHWARZ Artificial Mains
ESH2-Z5
100104
Dec. 6, 2017
Dec. 5, 2018
Network (for EUT)
LISN With Adapter (for EUT)
AD10
C09Ada-001
Dec. 6, 2017
Dec. 5, 2018
ROHDE & SCHWARZ Artificial Mains
ESH3-Z5
847265/023
Nov. 03, 2017 Nov. 02, 2018
Network (for peripherals)
SCHWARZBECK
NNLK8129
8129229
May 3, 2018
May 2, 2019
Artificial Mains Network (For EUT)
Software
Cond_V7.3.7.4
NA
NA
NA
RF cable (JYEBAO)
5D-FB
Cable-C09.01 Feb. 21, 2018 Feb. 20, 2019
With 10dB PAD
SUHNER Terminator
65BNC-5001
E1-010789
May 8, 2018
May 7, 2019
(For ROHDE & SCHWARZ LISN)
Notes: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.
2. The test was performed in Shielded Room No. 9.
3. Tested Date: Jun. 1 ~ 27, 2018
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 38 / 62
Report Format Version: 6.1.1
4.2.3
Test Procedures
a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
connected to the power mains through a line impedance stabilization network (LISN). Other support
units were connected to the power mains through another LISN. The two LISNs provide 50 ohm/ 50uH
of coupling impedance for the measuring instrument.
b. Both lines of the power mains connected to the EUT were checked for maximum conducted
interference.
c. The frequency range from 150kHz to 30MHz was searched. Emission levels under (Limit - 20dB) was
not recorded.
NOTE: The resolution bandwidth and video bandwidth of test receiver is 9kHz for quasi-peak detection (QP)
and average detection (AV) at frequency 0.15MHz-30MHz.
4.2.4
Deviation from Test Standard
No deviation.
4.2.5
Test Setup
Vertical Ground
Reference Plane
40cm
Test Receiver
EUT
80cm
LISN
Horizontal Ground
Reference Plane
Note: 1.Support units were connected to second LISN.
For the actual test configuration, please refer to the attached file (Test Setup Photo).
4.2.6
EUT Operating Conditions
Mode A:
a. Connected the EUT with AC adapter placed on testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.
Mode B:
a. Connected the EUT with PoE adapter placed on testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 39 / 62
Report Format Version: 6.1.1
4.2.7
Test Results
Phase
Line (L)
Test Mode
Mode A
No
Freq.
[MHz]
0.18125
0.37266
1.07422
3.35547
12.40234
15.07422
Corr.
Factor
(dB)
10.12
10.15
10.26
10.42
10.77
10.89
Detector Function
Reading Value
[dB (uV)]
Q.P.
AV.
28.82
17.79
36.63
30.57
24.82
16.18
23.31
15.07
28.54
25.40
35.80
35.69
Emission Level
[dB (uV)]
Q.P.
AV.
38.94
27.91
46.78
40.72
35.08
26.44
33.73
25.49
39.31
36.17
46.69
46.58
Quasi-Peak (QP) /
Average (AV)
Limit
[dB (uV)]
Q.P.
AV.
64.43
54.43
58.44
48.44
56.00
46.00
56.00
46.00
60.00
50.00
60.00
50.00
Margin
(dB)
Q.P.
AV.
-25.49
-26.52
-11.66
-7.72
-20.92
-19.56
-22.27
-20.51
-20.69
-13.83
-13.31
-3.42
REMARKS:
1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
2. The emission levels of other frequencies were very low against the limit.
3. Margin value = Emission level - Limit value
4. Correction factor = Insertion loss + Cable loss
5. Emission Level = Correction Factor + Reading Value.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 40 / 62
Report Format Version: 6.1.1
Phase
Neutral (N)
Test Mode
Mode A
No
Freq.
[MHz]
0.17734
0.37266
1.42969
3.50000
8.61719
15.07422
Corr.
Factor
(dB)
10.13
10.16
10.30
10.45
10.61
10.77
Detector Function
Reading Value
[dB (uV)]
Q.P.
AV.
30.36
17.46
37.64
31.48
24.30
15.46
23.62
14.60
25.13
20.26
36.78
35.20
Emission Level
[dB (uV)]
Q.P.
AV.
40.49
27.59
47.80
41.64
34.60
25.76
34.07
25.05
35.74
30.87
47.55
45.97
Quasi-Peak (QP) /
Average (AV)
Limit
[dB (uV)]
Q.P.
AV.
64.61
54.61
58.44
48.44
56.00
46.00
56.00
46.00
60.00
50.00
60.00
50.00
Margin
(dB)
Q.P.
AV.
-24.12
-27.02
-10.64
-6.80
-21.40
-20.24
-21.93
-20.95
-24.26
-19.13
-12.45
-4.03
REMARKS:
1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
2. The emission levels of other frequencies were very low against the limit.
3. Margin value = Emission level - Limit value
4. Correction factor = Insertion loss + Cable loss
5. Emission Level = Correction Factor + Reading Value.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 41 / 62
Report Format Version: 6.1.1
Phase
Line (L)
Test Mode
Mode B
No
Freq.
[MHz]
0.16173
0.42761
0.59142
1.19508
3.15098
21.39072
Corr.
Factor
(dB)
10.11
10.15
10.18
10.26
10.41
11.13
Detector Function
Reading Value
[dB (uV)]
Q.P.
AV.
37.61
27.19
29.96
23.25
17.74
12.15
15.00
9.60
12.27
8.02
28.92
26.41
Emission Level
[dB (uV)]
Q.P.
AV.
47.72
37.30
40.11
33.40
27.92
22.33
25.26
19.86
22.68
18.43
40.05
37.54
Quasi-Peak (QP) /
Average (AV)
Limit
[dB (uV)]
Q.P.
AV.
65.37
55.37
57.30
47.30
56.00
46.00
56.00
46.00
56.00
46.00
60.00
50.00
Margin
(dB)
Q.P.
AV.
-17.65
-18.07
-17.19
-13.90
-28.08
-23.67
-30.74
-26.14
-33.32
-27.57
-19.95
-12.46
REMARKS:
1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
2. The emission levels of other frequencies were very low against the limit.
3. Margin value = Emission level - Limit value
4. Correction factor = Insertion loss + Cable loss
5. Emission Level = Correction Factor + Reading Value.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 42 / 62
Report Format Version: 6.1.1
Phase
Neutral (N)
Test Mode
Mode B
No
Freq.
[MHz]
0.15782
0.42370
0.58993
1.19207
4.48038
21.39463
Corr.
Factor
(dB)
10.12
10.16
10.19
10.28
10.50
10.86
Detector Function
Reading Value
[dB (uV)]
Q.P.
AV.
35.29
21.12
28.31
21.59
16.42
10.90
12.32
6.99
6.91
2.55
29.84
27.16
Emission Level
[dB (uV)]
Q.P.
AV.
45.41
31.24
38.47
31.75
26.61
21.09
22.60
17.27
17.41
13.05
40.70
38.02
Quasi-Peak (QP) /
Average (AV)
Limit
[dB (uV)]
Q.P.
AV.
65.58
55.58
57.38
47.38
56.00
46.00
56.00
46.00
56.00
46.00
60.00
50.00
Margin
(dB)
Q.P.
AV.
-20.17
-24.34
-18.91
-15.63
-29.39
-24.91
-33.40
-28.73
-38.59
-32.95
-19.30
-11.98
REMARKS:
1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
2. The emission levels of other frequencies were very low against the limit.
3. Margin value = Emission level - Limit value
4. Correction factor = Insertion loss + Cable loss
5. Emission Level = Correction Factor + Reading Value.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 43 / 62
Report Format Version: 6.1.1
4.3
4.3.1
6dB Bandwidth Measurement
Limits of 6dB Bandwidth Measurement
The minimum of 6dB Bandwidth Measurement is 0.5 MHz.
4.3.2
Test Setup
EUT
4.3.3 Test Instruments
DESCRIPTION &
MANUFACTURER
ROHDE & SCHWARZ
Spectrum Analyzer
Anritsu Power Sensor
Anritsu Power Meter
Attenuator
Spectrum
Analyzer
MODEL NO.
SERIAL NO.
CALIBRATED
DATE
CALIBRATED
UNTIL
FSV40
101042
Sep. 29, 2017
Sep. 28, 2018
MA2411B
ML2495A
0738404
0842014
Apr. 26, 2018
Apr. 26, 2018
Apr. 25, 2019
Apr. 25, 2019
NOTE: 1. The calibration interval of the above test instruments is 12/24 months. And the calibrations are
traceable to NML/ROC and NIST/USA.
2. The test was performed in Chamber No. 6.
3. The Industry Canada Reference No. IC 7450E-6.
4. Tested Date: Jun. 22, 2018
4.3.4
a.
b.
c.
d.
e.
4.3.5
Test Procedure
Set resolution bandwidth (RBW) = 100kHz
Set the video bandwidth (VBW) ≥ 3 x RBW, Detector = Peak.
Trace mode = max hold.
Sweep = auto couple.
Measure the maximum width of the emission that is constrained by the frequencies associated with the
two amplitude points (upper and lower) that are attenuated by 6 dB relative to the maximum level
measured in the fundamental emission
Deviation fromTest Standard
No deviation.
4.3.6
EUT Operating Conditions
The software provided by client to enable the EUT under transmission condition continuously at lowest,
middle and highest channel frequencies individually.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 44 / 62
Report Format Version: 6.1.1
4.3.7
Test Result
Mode A
802.11b
6db Bandwidth (MHz)
Chain 0
Chain 1
Minimum Limit
(MHz)
2412
7.05
7.08
0.5
PASS
2437
7.10
7.11
0.5
PASS
11
2462
7.05
7.09
0.5
PASS
Pass / Fail
Channel
Frequency (MHz)
Pass / Fail
802.11g
6db Bandwidth (MHz)
Chain 0
Chain 1
Minimum Limit
(MHz)
2412
15.17
15.19
0.5
PASS
2437
15.18
15.17
0.5
PASS
11
2462
15.15
15.18
0.5
PASS
Pass / Fail
Channel
Frequency (MHz)
802.11n (20MHz)
6db Bandwidth (MHz)
Chain 0
Chain 1
Minimum Limit
(MHz)
2412
16.98
16.78
0.5
PASS
2437
15.14
15.17
0.5
PASS
11
2462
15.16
15.14
0.5
PASS
Pass / Fail
Channel
Frequency (MHz)
802.11n (40MHz)
6db Bandwidth (MHz)
Chain 0
Chain 1
Minimum Limit
(MHz)
2422
35.10
35.12
0.5
PASS
2437
31.43
33.85
0.5
PASS
2452
35.11
35.05
0.5
PASS
Channel
Frequency (MHz)
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 45 / 62
Report Format Version: 6.1.1
Spectrum Plot of Worst Value
802.11b / Chain 1 : CH6
802.11g / Chain 1 : CH1
802.11n (20MHz) / Chain 0 : CH1
802.11n (40MHz) / Chain 1 : CH3
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 46 / 62
Report Format Version: 6.1.1
4.4
Conducted Output Power Measurement
4.4.1
Limits of Conducted Output Power Measurement
For systems using digital modulation in the 2400–2483.5 MHz bands: 1 Watt (30dBm)
Per KDB 662911 D01 Multiple Transmitter Output Method of conducted output power measurement on IEEE
802.11 devices,
Array Gain = 0 dB (i.e., no array gain) for NANT ≤ 4;
Array Gain = 0 dB (i.e., no array gain) for channel widths ≥ 40 MHz for any NANT;
Array Gain = 5 log(NANT/NSS) dB or 3 dB, whichever is less for 20-MHz channel widths with NANT ≥ 5.
For power measurements on all other devices: Array Gain = 10 log(NANT/NSS) dB.
4.4.2
Test Setup
EUT
4.4.3
Attenuator
Power Sensor
Power Meter
Test Instruments
Refer to section 4.3.3 to get information of above instrument.
4.4.4
Test Procedures
Average power sensor was used to perform output power measurement, trigger and gating function of wide
band power meter is enabled to measure max output power of TX on burst. Duty factor is not added to
measured value.
4.4.5
Deviation from Test Standard
No deviation.
4.4.6
EUT Operating Conditions
Same as Item 4.3.6.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 47 / 62
Report Format Version: 6.1.1
4.4.7
Test Results
Mode A
802.11b
Chan.
Chan.
Freq.
(MHz)
Chain 0
Chain 1
Total Power
(mW)
Total Power
(dBm)
Limit
(dBm)
Pass / Fail
2412
21.02
21.20
258.300
24.12
30
Pass
2437
22.49
22.62
360.229
25.57
30
Pass
11
2462
21.39
21.60
282.265
24.51
30
Pass
Chan.
Freq.
(MHz)
Average Power (dBm)
Chan.
Chain 0
Chain 1
Total Power
(mW)
Total Power
(dBm)
Limit
(dBm)
Pass / Fail
2412
15.18
15.33
67.080
18.27
30
Pass
2417
15.76
15.84
76.041
18.81
30
Pass
2437
20.61
20.82
235.861
23.73
30
Pass
10
2457
17.22
17.41
107.804
20.33
30
Pass
11
2462
15.20
15.27
66.764
18.25
30
Pass
Total Power
(dBm)
Limit
(dBm)
Pass / Fail
Average Power (dBm)
802.11g
802.11n (20MHz)
Chan.
Chan.
Freq.
(MHz)
Chain 0
Chain 1
Total Power
(mW)
2412
14.64
14.73
58.824
17.70
30
Pass
2417
15.18
15.34
67.159
18.27
30
Pass
2437
20.85
21.10
250.444
23.99
30
Pass
10
2457
13.99
14.18
51.243
17.10
30
Pass
11
2462
13.09
13.37
42.097
16.24
30
Pass
Total Power
(dBm)
Limit
(dBm)
Pass / Fail
Average Power (dBm)
802.11n (40MHz)
Chan.
Chan.
Freq.
(MHz)
Chain 0
Chain 1
Total Power
(mW)
2422
12.47
12.52
35.525
15.51
30
Pass
2427
13.25
13.44
43.215
16.36
30
Pass
2437
18.50
18.57
142.740
21.55
30
Pass
2447
13.52
13.74
46.150
16.64
30
Pass
2452
12.50
12.72
36.490
15.62
30
Pass
Report No.: RF180615D14
Reference No.: 180425D01
Average Power (dBm)
Page No. 48 / 62
Report Format Version: 6.1.1
4.5
4.5.1
Power Spectral Density Measurement
Limits of Power Spectral Density Measurement
The Maximum of Power Spectral Density Measurement is 8dBm in any 3 kHz.
4.5.2
Test Setup
EUT
4.5.3
Attenuator
Spectrum
Analyzer
Test Instruments
Refer to section 4.3.3 to get information of above instrument.
4.5.4
Test Procedure
For duty cycle ≥ 98%
a) Set instrument center frequency to DTS channel center frequency.
b) Set span to at least 1.5 times the OBW.
c) Set RBW to: 3 kHz ≤ RBW ≤ 100 kHz. .
d) Set VBW ≥3 x RBW.
e) Detector = power averaging (RMS) or sample detector (when RMS not available).
f) Ensure that the number of measurement points in the sweep ≥ 2 x span/RBW.
g) Sweep time = auto couple.
h) Employ trace averaging (RMS) mode over a minimum of 100 traces.
i) Use the peak marker function to determine the maximum amplitude level.
For duty cycle < 98%
a) Measure the duty cycle (x).
b) Set instrument center frequency to DTS channel center frequency.
c) Set span to at least 1.5 times the OBW.
d) Set RBW to: 3 kHz ≤ RBW ≤ 100 kHz..
e) Set VBW ≥3 x RBW.
f) Detector = power averaging (RMS) or sample detector (when RMS not available).
g) Ensure that the number of measurement points in the sweep ≥ 2 x span/RBW.
h) Sweep time = auto couple.
i) Do not use sweep triggering. Allow sweep to “free run”.
j) Employ trace averaging (RMS) mode over a minimum of 100 traces.
k) Use the peak marker function to determine the maximum amplitude level.
l) Add 10 log (1/x), where x is the duty cycle measured in step (a, to the measured PSD to compute the
average PSD during the actual transmission time.
4.5.5
Deviation from Test Standard
No deviation.
4.5.6
EUT Operating Condition
Same as Item 4.3.6
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 49 / 62
Report Format Version: 6.1.1
4.5.7
Test Results
Mode A
802.11b
TX
chain
Channel
Freq.
(MHz)
PSD
(dBm/3kHz)
10 log
(N=2) dB
Total PSD
(dBm/3kHz)
Limit
(dBm/3kHz)
Pass
/Fail
2412
-0.61
3.01
2.40
6.99
Pass
2437
1.62
3.01
4.63
6.99
Pass
11
2462
-0.65
3.01
2.36
6.99
Pass
2412
-0.11
3.01
2.90
6.99
Pass
2437
1.46
3.01
4.47
6.99
Pass
11
2462
0.14
3.01
3.15
6.99
Pass
Note: 1. Directional gain = 4dBi + 10log(2) = 7.01dBi > 6dBi , so the power density limit shall be reduced to
8-(7.01-6) = 6.99dBm.
2. Refer to section 3.3 for duty cycle spectrum plot.
802.11g
TX
chain
Channel
Freq.
(MHz)
PSD w/o
Duty Factor
(dBm/3kHz)
10 log
(N=2)
dB
Duty
Factor
(dB)
TOTAL PSD
With Duty
Factor
(dBm/3kHz)
Limit
(dBm/3kHz)
Pass
/Fail
2412
-9.30
3.01
0.13
-6.16
6.99
Pass
2437
-5.06
3.01
0.13
-1.92
6.99
Pass
11
2462
-9.57
3.01
0.13
-6.43
6.99
Pass
2412
-10.37
3.01
0.13
-7.23
6.99
Pass
2437
-4.24
3.01
0.13
-1.10
6.99
Pass
11
2462
-9.53
3.01
0.13
-6.39
6.99
Pass
Note: 1. Directional gain = 4dBi + 10log(2) = 7.01dBi > 6dBi , so the power density limit shall be reduced to
8-(7.01-6) = 6.99dBm.
2. Refer to section 3.3 for duty cycle spectrum plot.
802.11n (20MHz)
TX
chain
Channel
Freq.
(MHz)
PSD w/o
Duty Factor
(dBm/3kHz)
10 log
(N=2)
dB
Duty
Factor
(dB)
TOTAL PSD
With Duty
Factor
(dBm/3kHz)
Limit
(dBm/3kHz)
Pass
/Fail
2412
-7.37
3.01
0.13
-4.23
6.99
Pass
2437
-4.58
3.01
0.13
-1.44
6.99
Pass
11
2462
-12.08
3.01
0.13
-8.94
6.99
Pass
2412
-6.71
3.01
0.13
-3.57
6.99
Pass
2437
-3.92
3.01
0.13
-0.78
6.99
Pass
11
2462
-11.20
3.01
0.13
-8.06
6.99
Pass
Note: 1. Directional gain = 4dBi + 10log(2) = 7.01dBi > 6dBi , so the power density limit shall be reduced to
8-(7.01-6) = 6.99dBm.
2. Refer to section 3.3 for duty cycle spectrum plot.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 50 / 62
Report Format Version: 6.1.1
802.11n (40MHz)
TX
chain
Channel
Freq.
(MHz)
PSD w/o
Duty Factor
(dBm/3kHz)
10 log
(N=2)
dB
Duty
Factor
(dB)
TOTAL PSD
With Duty
Factor
(dBm/3kHz)
Limit
(dBm/3kHz)
Pass
/Fail
2422
-16.22
3.01
0.34
-12.87
6.99
Pass
2437
-9.56
3.01
0.34
-6.21
6.99
Pass
2452
-16.25
3.01
0.34
-12.90
6.99
Pass
2422
-16.05
3.01
0.34
-12.70
6.99
Pass
2437
-9.62
3.01
0.34
-6.27
6.99
Pass
2452
-15.08
3.01
0.34
-11.73
6.99
Pass
Note: 1. Directional gain = 4dBi + 10log(2) = 7.01dBi > 6dBi , so the power density limit shall be reduced to
8-(7.01-6) = 6.99dBm.
2. Refer to section 3.3 for duty cycle spectrum plot.
Spectrum Plot of Worst Value
802.11b / Chain 0 : CH6
802.11g / Chain 1 : CH6
802.11n (20MHz) / Chain 1 : CH6
802.11n (40MHz) / Chain 0 : CH6
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 51 / 62
Report Format Version: 6.1.1
4.6
4.6.1
Conducted Out of Band Emission Measurement
Limits of Conducted Out of Band Emission Measurement
Below -30dB of the highest emission level of operating band (in 100kHz Resolution Bandwidth).
4.6.2
Test Setup
EUT
4.6.3
Attenuator
Spectrum
Analyzer
Test Instruments
Refer to section 4.3.3 to get information of above instrument.
4.6.4
Test Procedure
MEASUREMENT PROCEDURE REF
1. Set the RBW = 100 kHz.
2. Set the VBW ≥ 300 kHz.
3. Detector = peak.
4. Sweep time = auto couple.
5. Trace mode = max hold.
6. Allow trace to fully stabilize.
7. Use the peak marker function to determine the maximum power level in any 100 kHz band segment within
the fundamental EBW.
MEASUREMENT PROCEDURE OOBE
1. Set RBW = 100 kHz.
2. Set VBW ≥ 300 kHz.
3. Detector = peak.
4. Sweep = auto couple.
5. Trace Mode = max hold.
6. Allow trace to fully stabilize.
7. Use the peak marker function to determine the maximum amplitude level.
4.6.5 Deviation from Test Standard
No deviation.
4.6.6
EUT Operating Condition
Same as Item 4.3.6
4.6.7
Test Results
The spectrum plots are attached on the following pages. D1 line indicates the highest level, and D2 line
indicates the 30dB offset below D1. It shows compliance with the requirement.
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 52 / 62
Report Format Version: 6.1.1
Mode A
802.11b: Chain 0
CH 1
CH 6
CH 11
CH 1 Band edge
Report No.: RF180615D14
Reference No.: 180425D01
CH 11 Band edge
Page No. 53 / 62
Report Format Version: 6.1.1
Chain 1
CH 1
CH 6
CH 11
CH 1 Band edge
Report No.: RF180615D14
Reference No.: 180425D01
CH 11 Band edge
Page No. 54 / 62
Report Format Version: 6.1.1
802.11g: Chain 0
CH 1
CH 6
CH 11
CH 1 Band edge
Report No.: RF180615D14
Reference No.: 180425D01
CH 11 Band edge
Page No. 55 / 62
Report Format Version: 6.1.1
Chain 1
CH 1
CH 6
CH 11
CH 1 Band edge
Report No.: RF180615D14
Reference No.: 180425D01
CH 11 Band edge
Page No. 56 / 62
Report Format Version: 6.1.1
802.11n (20MHz): Chain 0
CH 1
CH 6
CH 11
CH 1 Band edge
Report No.: RF180615D14
Reference No.: 180425D01
CH 11 Band edge
Page No. 57 / 62
Report Format Version: 6.1.1
Chain 1
CH 1
CH 6
CH 11
CH 1 Band edge
Report No.: RF180615D14
Reference No.: 180425D01
CH 11 Band edge
Page No. 58 / 62
Report Format Version: 6.1.1
802.11n (40MHz): Chain 0
CH 3
CH 6
CH 9
CH 3 Band edge
Report No.: RF180615D14
Reference No.: 180425D01
CH 9 Band edge
Page No. 59 / 62
Report Format Version: 6.1.1
Chain 1
CH 3
CH 6
CH 9
CH 3 Band edge
Report No.: RF180615D14
Reference No.: 180425D01
CH 9 Band edge
Page No. 60 / 62
Report Format Version: 6.1.1
5
Pictures of Test Arrangements
Please refer to the attached file (Test Setup Photo).
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 61 / 62
Report Format Version: 6.1.1
Appendix – Information on the Testing Laboratories
We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.
If you have any comments, please feel free to contact us at the following:
Linkou EMC/RF Lab
Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180
Fax: 886-2-26051924
Tel: 886-3-6668565
Fax: 886-3-6668323
Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892
Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com
The address and road map of all our labs can be found in our web site also.
--- END ---
Report No.: RF180615D14
Reference No.: 180425D01
Page No. 62 / 62
Report Format Version: 6.1.1
Download: OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Mirror Download [FCC.gov]OAW-AP1201H OmniAccess Stellar Test Report RF ALE USA Inc.
Document ID3957219
Application ID83zwiZhtweU2X6Q9fwkvWQ==
Document DescriptionRF Test Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize162.15kB (2026846 bits)
Date Submitted2018-08-09 00:00:00
Date Available2018-08-09 00:00:00
Creation Date2018-07-30 10:44:20
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2018-07-30 10:44:49
Document TitleRF Test Report
Document CreatorPScript5.dll Version 5.2.2
Document Author: anchang

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : anchang
Create Date                     : 2018:07:30 10:44:20+08:00
Modify Date                     : 2018:07:30 10:44:49+08:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Format                          : application/pdf
Title                           : Microsoft Word - RF180615D14_Sercomm AP_2.4G WLAN _1.5m_ _RF_v6.1.1 2T2R_ AV Power 有PoE_Copy
Creator                         : anchang
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2018:07:30 10:44:49+08:00
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:c2cf2f86-dc88-4d5e-b449-8f243e7f4476
Instance ID                     : uuid:dc3cb4e7-4d3a-4821-a12d-77fdf6c5cf34
Page Count                      : 62