FCC ID 2AIAY-RMAST1

Water meter register that count the water flow and wireless transmitting the counting data using integrated radio.

by Contadores de agua de Zaragoza S.A.

Grantee Code: 2AIAY   Product Code: RMAST1
Latest application date: 2018-02-19

FCC ID Device Details

FCC ID2AIAY-RMAST1
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AIAY
Product CodeRMAST1
Applicant BusinessContadores de agua de Zaragoza S.A. 🇪🇸
Related Domains contazara.es aradtec.com
Equipment ClassWater meter register that count the water flow and wireless transmitting the counting data using integrated radio.
Test FirmQualitech

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.3-914.9 MHzOriginal Equipment2018-02-19
903-916.3 MHzOriginal Equipment2018-02-19

Exhibits

DocumentTypeAvailableFile
Users manualUsers Manual2018-02-19PDF 285.8 KB
Internal photographsInternal Photos2018-02-19PDF 739.2 KB
External photographsExternal Photos2018-02-19PDF 377.4 KB
Label / label locationID Label/Location Info2018-02-19PDF 310.1 KB
Test set up photographsTest Setup Photos2018-02-19PDF 356.6 KB
Test reportTest Report2018-02-19PDF 2.1 MB
Authorisation letterCover Letter(s)2018-02-19PDF 44 KB
Confidentiality requestCover Letter(s)2018-02-19PDF 81.9 KB
RF exposure evaluationRF Exposure Info2018-02-19PDF 178.9 KB
Block diagram Metadata onlyBlock DiagramPDF 226.3 KB
Schematic diagram Metadata onlySchematicsPDF 724.7 KB
Operational description Metadata onlyOperational DescriptionPDF 444.1 KB

Application Information

Application IDsEuZsVwLaXkEfhO6bjv6FQ==
Final Action Date2018-02-19
Application PurposeOriginal Equipment
Applicant FRN0025552050
ModelRMAST1
Frequency Range902.3-914.9 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionWater meter register that count the water flow and wireless transmitting the counting data using integrated radio.
Responsible PartyNatalia Cebrian, ncebrian@contazara.es , +34976500691
AgentRami Rami Rami, QualiTech EMC Laboratory, rami.nataf@ecitele.com , 972-3-9266994
Technical ContactGabi Ben Yaakov, Arad Measuring Technologies Ltd., gabi.ben-yaakov@aradtec.com , +97249095033
Non-Technical ContactSnir Azulay, Arad Measuring Technologies Ltd., snirazulay@aradtec.com , 97249095033
Test FirmMeir Bass, Qualitech, Meir.Bass@ecitele.com , 972-3-9266994
TCB Emailhotline@acbcert.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is conducted. Certified for mobile use. Co-location of this device with other transmitters would require use of FCC multi-transmitter product procedures.

Applications

Application IDDatePurpose
sEuZsVwLaXkEfhO6bjv6FQ==2018-02-19Original Equipment
Y0t0ibSjMIzUSve+JNbaUQ==2018-02-19Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
902.3-914.9 MHz0.101000015CCC
903-916.3 MHz0.102000015CCC

Grants

TCB Grant - Application Y0t0ibSjMIzUSve+JNbaUQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 02/19/2018

Application Dated: 02/16/2018
Contadores de agua de Zaragoza S.A.
Carretera Castellon km. 5.5
Zaragoza, 50720
Spain
 
Attention: Natalia Cebrian

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIAY-RMAST1
Name of Grantee:  Contadores de agua de Zaragoza S.A.
Equipment Class: Digital Transmission System
Notes: Water meter register that count the water flow and wireless transmitting the counting data using integrated radio.
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 903.0  -  916.3 0.102  

Output power is conducted. Certified for mobile use. Co-location of this device with other transmitters would require use of FCC multi-transmitter product procedures.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application Y0t0ibSjMIzUSve+JNbaUQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Contadores de agua de Zaragoza S.A.
Carretera Castellon km. 5.5
Zaragoza, 50720
Spain
  Date of Grant: 02/19/2018

Application Dated: 02/16/2018
 
Attention: Natalia Cebrian

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIAY-RMAST1
Name of Grantee:  Contadores de agua de Zaragoza S.A.
Equipment Class: Digital Transmission System
Notes: Water meter register that count the water flow and wireless transmitting the counting data using integrated radio.
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 903.0  -  916.3 0.102  

Output power is conducted. Certified for mobile use. Co-location of this device with other transmitters would require use of FCC multi-transmitter product procedures.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application sEuZsVwLaXkEfhO6bjv6FQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 02/19/2018

Application Dated: 02/16/2018
Contadores de agua de Zaragoza S.A.
Carretera Castellon km. 5.5
Zaragoza, 50720
Spain
 
Attention: Natalia Cebrian

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIAY-RMAST1
Name of Grantee:  Contadores de agua de Zaragoza S.A.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Water meter register that count the water flow and wireless transmitting the counting data using integrated radio.
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 902.3  -  914.9 0.101  

Output power is conducted. Certified for mobile use. Co-location of this device with other transmitters would require use of FCC multi-transmitter product procedures.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application sEuZsVwLaXkEfhO6bjv6FQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Contadores de agua de Zaragoza S.A.
Carretera Castellon km. 5.5
Zaragoza, 50720
Spain
  Date of Grant: 02/19/2018

Application Dated: 02/16/2018
 
Attention: Natalia Cebrian

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIAY-RMAST1
Name of Grantee:  Contadores de agua de Zaragoza S.A.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Water meter register that count the water flow and wireless transmitting the counting data using integrated radio.
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 902.3  -  914.9 0.101  

Output power is conducted. Certified for mobile use. Co-location of this device with other transmitters would require use of FCC multi-transmitter product procedures.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: