SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V

Darmuoba, S.A. de C.V 3G Smartphone

Page 1 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 2 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 3 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 4 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 5 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 6 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 7 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 8 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 9 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 10 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 11 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 12 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 13 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 14 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 15 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 16 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 17 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 18 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Page 19 of SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V

Global United Technology Services Co., Ltd.
Report No.: GTS201811000020F05
TEST REPORT
Applicant:
Darmuoba, S.A. de C.V
Address of Applicant:
Mar Negro 1, Col. Tacuba, CDMX. C.P 11410 Miguel Hidalgo,
Distrito Federal, Mexico
Z-TECH COMMUNICATION(SZ)Co.Ltd
Manufacturer/ Factory:
7/F BLK D BAO'AN ZHI'GU YIN'TIAN RD. NO.4 XI'XIANG ST'
Address of
BAO'AN Shenzhen, China
Manufacturer/ Factory:
Equipment Under Test (EUT)
Product Name:
3G Smartphone
Model No.:
SD57
Trade Mark:
Uneone
FCC ID:
2AIFYSD57
Applicable standards:
FCC CFR Title 47 Part 15 Subpart B
Date of sample receipt:
November 06, 2018
Date of Test:
November 07-15, 2018
Date of report issued:
November 16, 2018
Test Result :
PASS *
* In the configuration tested, the EUT complied with the standards specified above.
Authorized Signature:
Robinson Lo
Laboratory Manager
This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in
full, without prior written permission of the company. The report would be invalid without specific stamp of test institute
and the signatures of compiler and approver.
Report No.: GTS201811000020F05
Version
Version No.
Date
Description
00
November 16, 2018
Original
Prepared By:
Date:
November 16, 2018
Date:
November 16, 2018
Project Engineer
Check By:
Reviewer
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 2 of 19
Report No.: GTS201811000020F05
Contents
COVER PAGE ........................................................................................................................................... 1
VERSION .................................................................................................................................................. 2
CONTENTS .............................................................................................................................................. 3
TEST SUMMARY ..................................................................................................................................... 4
GENERAL INFORMATION ...................................................................................................................... 5
5.1
5.2
5.3
5.4
5.5
5.6
5.7
GENERAL DESCRIPTION OF EUT ......................................................................................................... 5
TEST MODE AND TEST VOLTAGE .......................................................................................................... 5
DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 6
DEVIATION FROM STANDARDS ............................................................................................................. 6
ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................... 6
TEST FACILITY .................................................................................................................................... 6
TEST LOCATION .................................................................................................................................. 6
TEST INSTRUMENTS LIST ..................................................................................................................... 7
TEST RESULTS AND MEASUREMENT DATA...................................................................................... 9
7.1
7.2
RADIATED EMISSION ........................................................................................................................... 9
CONDUCTED EMISSIONS ................................................................................................................... 15
TEST SETUP PHOTO ............................................................................................................................ 18
EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 19
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 3 of 19
Report No.: GTS201811000020F05
Test Summary
Test Item
Test Requirement
Test Method
Class / Severity
Result
Conducted Emission
FCC Part15.107
ANSI C63.4
Class B
PASS
Radiated Emissions #
FCC Part15.109
ANSI C63.4
Class B
PASS
Remark:
1.
Pass: The EUT complies with the essential requirements in the standard.
2.
# Refer to FCC Part 15.33 (b)(1) conditional testing procedure :
The highest frequency generated or used in the EUT
Test frequency range of Radiated emission
<108MHz
30MHz ~ 1GHz
108MHz ~ 500MHz
30MHz ~ 2GHz
500MHz ~ 1GHz
30MHz ~ 5GHz
>1GHz
30MHz ~ 5th harmonic of the highest frequency or 40
GHz, whichever is lower.
Measurement Uncertainty
Test Item
Frequency Range
Measurement Uncertainty
Notes
Radiated Emission
9kHz ~ 30MHz
± 4.54dB
(1)
Radiated Emission
30MHz ~ 200MHz
± 3.92dB
(1)
Radiated Emission
200MHz~1000 MHz
± 4.10dB
(1)
Radiated Emission
1GHz ~ 6GHz
± 5.34dB
(1)
AC Power Line Conducted
Emission
0.15MHz ~ 30MHz
± 3.44dB
(1)
Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 4 of 19
Report No.: GTS201811000020F05
General Information
5.1 General Description of EUT
Product Name:
3G Smartphone
Model No.:
SD57
Serial No.:
352969090000431
Hardware version:
SD57_V1.3
Software version:
UNEONE_SD57_003R
Test sample(s) ID:
GTS201811000020-2
Sample(s) Status
Normal sample
Power supply:
Adaptor:
Model:SD57-A
Input: AC 100-240V, 50/60Hz, 150mA
Output: DC 5V, 700Ma
Or
Battery: DC 3.7V, 1800mAh, 6.66Wh
5.2 Test mode and Test voltage
Test mode:
PC mode
Keep the EUT in PC mode.
REC mode
Keep the EUT in REC mode.
Audio play mode
Keep the EUT in Audio play mode.
Video play mode
Keep the EUT in Video play mode.
Test voltage
AC120V 60Hz & DC 3.7V
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 5 of 19
Report No.: GTS201811000020F05
5.3 Description of Support Units
Manufacturer
Description
Model
Serial Number
Lenovo
Notebook PC
E40-80
N/A
Canon
Printer
IP1600
N/A
DELL
KEYBOARD
SK-8115
GTS237-2
DELL
MOUSE
MOC5UO
GTS237-3
5.4 Deviation from Standards
None.
5.5 Abnormalities from Standard Conditions
None.
5.6 Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
● FCC —Registration No.: 381383
Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and fully
described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
from the FCC is maintained in files. Registration 381383, January 08, 2018.
● Industry Canada (IC) —Registration No.: 9079A-2
The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been
registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
with Registration No.: 9079A-2, August 15, 2016
5.7 Test Location
The test was performed at:
Global United Technology Services Co., Ltd.
Address: No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road,
Baoan District, Shenzhen, Guangdong, China 518102
Tel: 0755-27798480
Fax: 0755-27798960
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 6 of 19
Report No.: GTS201811000020F05
Test Instruments list
Radiated Emission:
Item
Test Equipment
Manufacturer
Model No.
Inventory
No.
Cal.Date
(mm-dd-yy)
Cal.Due date
(mm-dd-yy)
3m Semi- Anechoic
Chamber
ZhongYu Electron
9.2(L)*6.2(W)* 6.4(H)
GTS250
July. 03 2015
July. 02 2020
Control Room
ZhongYu Electron
6.2(L)*2.5(W)* 2.4(H)
GTS251
N/A
N/A
EMI Test Receiver
Rohde & Schwarz
ESU26
GTS203
June. 27 2018
June. 26 2019
BiConiLog Antenna
SCHWARZBECK
MESS-ELEKTRONIK
VULB9163
GTS214
June. 27 2018
June. 26 2019
Double -ridged waveguide SCHWARZBECK
MESS-ELEKTRONIK
horn
9120D-829
GTS208
June. 27 2018
June. 26 2019
Horn Antenna
ETS-LINDGREN
3160
GTS217
June. 27 2018
June. 26 2019
EMI Test Software
AUDIX
E3
N/A
N/A
N/A
Coaxial Cable
GTS
N/A
GTS213
June. 27 2018
June. 26 2019
Coaxial Cable
GTS
N/A
GTS211
June. 27 2018
June. 26 2019
10
Coaxial cable
GTS
N/A
GTS210
June. 27 2018
June. 26 2019
11
Coaxial Cable
GTS
N/A
GTS212
June. 27 2018
June. 26 2019
12
Amplifier(100kHz-3GHz)
HP
8347A
GTS204
June. 27 2018
June. 26 2019
13
Amplifier(2GHz-20GHz)
HP
8349B
GTS206
June. 27 2018
June. 26 2019
14
Amplifier (18-26GHz)
Rohde & Schwarz
GTS218
June. 27 2018
June. 26 2019
15
Band filter
Amindeon
82346
GTS219
June. 27 2018
June. 26 2019
16
Power Meter
Anritsu
ML2495A
GTS540
June. 27 2018
June. 26 2019
17
Power Sensor
Anritsu
MA2411B
GTS541
June. 27 2018
June. 26 2019
18
Wideband Radio
Communication Tester
Rohde & Schwarz
CMW500
GTS588
June. 27 2018
June. 26 2019
19
Splitter
Agilent
11636B
GTS237
June. 27 2018
June. 26 2019
20
Loop Antenna
ZHINAN
ZN30900A
GTS534
June. 27 2018
June. 26 2019
AFS33-18002
650-30-8P-44
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 7 of 19
Report No.: GTS201811000020F05
Conducted Emission
Item
Test Equipment
Shielding Room
EMI Test Receiver
Coaxial Switch
Artificial Mains Network
Coaxial Cable
EMI Test Software
Thermo meter
Absorbing clamp
Manufacturer
ZhongYu Electron
R&S
ANRITSU CORP
SCHWARZBECK
MESS
GTS
AUDIX
KTJ
ElektronikFeinmechanik
Inventory
Cal.Date
No.
(mm-dd-yy)
GTS252
May.16 2014
GTS552
June. 27 2018
GTS225
June. 27 2018
Cal.Due date
(mm-dd-yy)
May.15 2019
June. 26 2019
June. 26 2019
NSLK8127
GTS226
June. 27 2018
June. 26 2019
N/A
E3
TA328
GTS227
N/A
GTS233
N/A
N/A
June. 27 2018
N/A
N/A
June. 26 2019
MDS21
GTS229
June. 27 2018
June. 26 2019
Model No.
7.3(L)x3.1(W)x2.9(H)
ESCI 7
MP59B
General used equipment:
Item
Test Equipment
Manufacturer
Model No.
Inventory
No.
Cal.Date
(mm-dd-yy)
Cal.Due date
(mm-dd-yy)
Humidity/
Temperature Indicator
Shanghai
ZJ1-2B
GTS243
June. 27 2018
June. 26 2019
Barometer
ChangChun
DYM3
GTS255
June. 27 2018
June. 26 2019
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 8 of 19
Report No.: GTS201811000020F05
Test Results and Measurement Data
7.1 Radiated Emission
Test Requirement:
FCC Part15 B Section 15.109
Test Method:
ANSI C63.4:2014
Test Frequency Range:
30MHz to 40GHz
Test site:
Measurement Distance: 3m (Semi-Anechoic Chamber)
Frequency
Detector
RBW
VBW
Remark
30MHzQuasi-peak
120kHz
300kHz Quasi-peak Value
1GHz
Peak
1MHz
3MHz
Peak Value
Above 1GHz
Peak
1MHz
10Hz
Average Value
Frequency
Limit (dBuV/m @3m)
Remark
Receiver setup:
Limit:
30MHz-88MHz
40.00
Quasi-peak Value
88MHz-216MHz
43.50
Quasi-peak Value
216MHz-960MHz
46.00
Quasi-peak Value
960MHz-1GHz
54.00
Quasi-peak Value
54.00
Average Value
74.00
Peak Value
Above 1GHz
Test setup:
For radiated emissions from 30MHz to1GHz
For radiated emissions above 1GHz
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 9 of 19
Report No.: GTS201811000020F05
Test environment:
The EUT was placed on the top of a rotating table 0.8 meters above
the ground at a 3 meter semi-anechoic chamber. The table was
rotated 360 degrees to determine the position of the highest
radiation.
2. The EUT was set 3 meters away from the interference-receiving
antenna, which was mounted on the top of a variable-height antenna
tower.
3. The antenna height is varied from one meter to four meters above
the ground to determine the maximum value of the field strength.
Both horizontal and vertical polarizations of the antenna are set to
make the measurement.
4. For each suspected emission, the EUT was arranged to its worst
case and then the antenna was tuned to heights from 1 meter to 4
meters and the rotatable table was turned from 0 degrees to 360
degrees to find the maximum reading.
5. The test-receiver system was set to Peak Detect Function and
Specified Bandwidth with Maximum Hold Mode.
6. If the emission level of the EUT in peak mode was 10dB lower than
the limit specified, then testing could be stopped and the peak
values of the EUT would be reported. Otherwise the emissions that
did not have 10dB margin would be re-tested one by one using
peak, quasi-peak or average method as specified and then reported
in a data sheet.
Temp.:
Humid.:
52%
Press.:
1 012mbar
25 °C
Test Instruments:
Refer to section 6 for details
Test mode:
Refer to section 5.2 for details, only show the worst case.
Test results:
Pass
Test Procedure:
1.
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 10 of 19
Report No.: GTS201811000020F05
Measurement Data
Below 1GHz
Test mode:
PC mode
Antenna Polarity:
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Horizontal
Page 11 of 19
Report No.: GTS201811000020F05
Test mode:
PC mode
Antenna Polarity:
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Vertical
Page 12 of 19
Report No.: GTS201811000020F05
Above 1GHz
Test mode:
PC mode
Antenna Polarity:
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Horizontal
Page 13 of 19
Report No.: GTS201811000020F05
Test mode:
PC mode
Antenna Polarity:
Vertical
Note:
The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
equation with a sample calculation is as follows:
Final Test Level =Receiver Reading + Antenna Factor + Cable Factor – Preamplifier Factor
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 14 of 19
Report No.: GTS201811000020F05
7.2 Conducted Emissions
Test Requirement:
FCC Part15 B Section 15.107
Test Method:
ANSI C63.4:2014
Test Frequency Range:
150kHz to 30MHz
Class / Severity:
Class B
RBW=9kHz, VBW=30kHz
Receiver setup:
Limit:
Frequency range (MHz)
0.15-0.5
0.5-5
0.5-30
Limit (dBµV)
Quasi-peak
Average
66 to 56*
56 to 46*
56
46
60
50
Test setup:
Test procedure
1.
The E.U.T and simulators are connected to the main power through
a line impedance stabilization network(L.I.S.N.). The provide a
50ohm/50uH coupling impedance for the measuring equipment.
2.
The peripheral devices are also connected to the main power
through a LISN that provides a 50ohm/50uH coupling impedance
with 50ohm termination. (Please refers to the block diagram of the
test setup and photographs).
3.
Both sides of A.C. line are checked for maximum conducted
interference. In order to find the maximum emission, the relative
positions of equipment and all of the interface cables must be
changed according to ANSI C63.4: 2014 on conducted
measurement.
25 °C
Test environment:
Temp.:
Humid.:
52%
Press.:
Test Instruments:
Refer to section 6 for details
Test mode:
Refer to section 5.2 for details, only show the worst case.
Test results:
Pass
1 012mbar
Remark: Both high and low voltages have been tested to show only the worst low voltage test data.
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 15 of 19
Report No.: GTS201811000020F05
Measurement Data
Test mode:
PC mode
Phase Polarity:
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Line
Page 16 of 19
Report No.: GTS201811000020F05
Test mode:
PC mode
Phase Polarity:
Neutral
Notes:
1. The following Quasi-Peak and Average measurements were performed on the EUT:
2. Final Test Level =Receiver Reading + LISN Factor + Cable Loss.
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 17 of 19
Report No.: GTS201811000020F05
Test Setup Photo
Radiated Emission
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 18 of 19
Report No.: GTS201811000020F05
Conducted Emission
EUT Constructional Details
Reference to the test report No. : GTS201811000020F01
------End------
Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960
Page 19 of 19
Download: SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Mirror Download [FCC.gov]SD57 3G Smartphone Test Report HD 271 S1 Darmuoba, S.A. de C.V
Document ID4114659
Application ID3YfyMoyRHjE5u3E9EE4tTA==
Document DescriptionGTS201811000020F05 Part 15B
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize77.79kB (972362 bits)
Date Submitted2018-12-24 00:00:00
Date Available2018-12-24 00:00:00
Creation Date2018-12-21 09:02:14
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2018-12-21 09:02:37
Document TitleHD 271 S1
Document CreatorAcrobat PDFMaker 11 Word 版
Document Author: LAB02

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : LAB02
Comments                        : 
Company                         : SGS-CSTC
Create Date                     : 2018:12:21 09:02:14+08:00
KSO Product Build Ver           : 2052-10.1.0.6569
Modify Date                     : 2018:12:21 09:02:37+08:00
Source Modified                 : D:20181220103935
Subject                         : 
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08
Metadata Date                   : 2018:12:21 09:02:37+08:00
Creator Tool                    : Acrobat PDFMaker 11 Word 版
Document ID                     : uuid:514172bf-229a-4700-a628-5b81ac9d41ea
Instance ID                     : uuid:b5956e06-bd17-4201-9ebd-33b569f84e75
Format                          : application/pdf
Title                           : HD 271 S1
Description                     : 
Creator                         : LAB02
Producer                        : Adobe PDF Library 11.0
Keywords                        : 
Page Layout                     : OneColumn
Page Count                      : 19