FCC ID 2AIOC-FLD01W
FLOOD SENSOR
by HANK ELECTRONICS CO., LTD.
Grantee Code: 2AIOC Product Code: FLD01W
Latest application date: 2018-06-14
FCC ID Device Details
| FCC ID | 2AIOC-FLD01W |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AIOC |
| Product Code | FLD01W |
| Applicant Business | HANK ELECTRONICS CO., LTD. 🇨🇳 |
| Related Domains | |
| Equipment Class | FLOOD SENSOR |
| Test Firm | WALTEK TESTING GROUP CO., LTD. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2018-06-14 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2018-06-14 | PDF 517.6 KB |
| internal photos | Internal Photos | 2018-06-14 | PDF 4.4 MB |
| external photos | External Photos | 2018-06-14 | PDF 246.1 KB |
| label | ID Label/Location Info | 2018-06-14 | PDF 422.2 KB |
| test setup photos | Test Setup Photos | 2018-06-14 | PDF 188 KB |
| test report | Test Report | 2018-06-14 | PDF 2 MB |
| confidentiality request letter | Cover Letter(s) | 2018-06-14 | PDF 86.6 KB |
| poa | Cover Letter(s) | 2018-06-14 | PDF 64.9 KB |
| sar exemption report | RF Exposure Info | 2018-06-14 | PDF 53.7 KB |
| block diagram Metadata only | Block Diagram | PDF 44.9 KB | |
| schematics Metadata only | Schematics | PDF 189.5 KB | |
| operation description Metadata only | Operational Description | PDF 513 KB |
Application Information
| Application ID | scJeHRv4UZr6Z/P4hBwmBg== |
|---|---|
| Final Action Date | 2018-06-14 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0025629411 |
| Model | FLD01W |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | FLOOD SENSOR |
| Responsible Party | GuangCan Yang, yangguangcan@hank-tech.com |
| Test Firm | Philo Zhong, WALTEK TESTING GROUP CO., LTD., Philo@waltek.com.cn |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. End-users must be provided with the specific operating instructions for satisfying RF exposure compliance. The device must operate with the minimum separation distance tested for compliance, as described in this filing, which is 20 cm. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| scJeHRv4UZr6Z/P4hBwmBg== | 2018-06-14 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2412-2462 MHz | 0.0264000 | 15C |
Grants
TCB Grant - Application scJeHRv4UZr6Z/P4hBwmBg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 06/14/2018 Application Dated: 06/14/2018 |
| HANK ELECTRONICS CO., LTD. |
| Floor 2nd-7th,A8,Hongye Industry City |
| Lezhujiao, Zhoushi Road,Baoan District |
| Shenzhen, China |
| Attention: GuangCan Yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AIOC-FLD01W |
| Name of Grantee: | HANK ELECTRONICS CO., LTD. |
| Equipment Class: | Digital Transmission System |
| Notes: | FLOOD SENSOR |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.0264 |
| Power listed is conducted. End-users must be provided with the specific operating instructions for satisfying RF exposure compliance. The device must operate with the minimum separation distance tested for compliance, as described in this filing, which is 20 cm. |
EAS Grant - Application scJeHRv4UZr6Z/P4hBwmBg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
HANK ELECTRONICS CO., LTD. Floor 2nd-7th,A8,Hongye Industry City Lezhujiao, Zhoushi Road,Baoan District Shenzhen, China |
Date of Grant: 06/14/2018 Application Dated: 06/14/2018 |
| Attention: GuangCan Yang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AIOC-FLD01W |
| Name of Grantee: | HANK ELECTRONICS CO., LTD. |
| Equipment Class: | Digital Transmission System |
| Notes: | FLOOD SENSOR |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.0264 |
| Power listed is conducted. End-users must be provided with the specific operating instructions for satisfying RF exposure compliance. The device must operate with the minimum separation distance tested for compliance, as described in this filing, which is 20 cm. |
| Mail To: |