FCC ID 2AIQ2-V01

SMART WATCH

by BLUE IDEA LIMITED

Grantee Code: 2AIQ2   Product Code: V01
Latest application date: 2016-09-28

Device Images

FCC ID Device Details

FCC ID2AIQ2-V01
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AIQ2
Product CodeV01
Applicant BusinessBLUE IDEA LIMITED 🇨🇳
Related Domains blueideagps.com
Equipment ClassSMART WATCH
Test FirmShenzhen Anbotek Compliance Laboratory Limited

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2016-09-28
824.2-848.8 MHzOriginal Equipment2016-09-28

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2016-09-28PDF 342.3 KB
Internal PhotosInternal Photos2016-09-28PDF 624.2 KB
Internal photosInternal Photos2016-09-28PDF 624.2 KB
External PhotosExternal Photos2016-09-28PDF 302 KB
LabelID Label/Location Info2016-09-28PDF 9.4 KB
Label LocationID Label/Location Info2016-09-28PDF 50.5 KB
Label locationID Label/Location Info2016-09-28PDF 50.5 KB
RF Test Set-up PhotosTest Setup Photos2016-09-28PDF 233.2 KB
RF Test ReportTest Report2016-09-28PDF 1.4 MB
RF Test ReportTest Report2016-09-28PDF 3.2 MB
Authorization LetterCover Letter(s)2016-09-28PDF 25.5 KB
DTS Ch 12&13 Declaration letterCover Letter(s)2016-09-28PDF 54.8 KB
Family model letterCover Letter(s)2016-09-28PDF 19.7 KB
LTC LetterCover Letter(s)2016-09-28PDF 25.8 KB
PAG letterCover Letter(s)2016-09-28PDF 654.8 KB
SAR ReportRF Exposure Info2016-09-28PDF 3.2 MB
Block Diagram Metadata onlyBlock DiagramPDF 18.5 KB
Schematics Metadata onlySchematicsPDF 347.6 KB
Operational Description Metadata onlyOperational DescriptionPDF 30.7 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 118.2 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 12.7 KB

Application Information

Application IDXBZGyVrKpXfmaHFxTkOH3A==
Final Action Date2016-09-28
Application PurposeOriginal Equipment
Applicant FRN0025658469
ModelV01
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSMART WATCH
Responsible PartyRosemary Kuang, Sales manager, rosemary@blueideagps.com , 86-755-27214172
Test FirmDaniel zhu, Shenzhen Anbotek Compliance Laboratory Limited, Daniel.zhu@anbotek.com , 86-755-26014771
TCB Emailtcb@siemic.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is the maximum conducted output power. Device contains 20 and 40 MHz signal bandwidth.

Applications

Application IDDatePurpose
XBZGyVrKpXfmaHFxTkOH3A==2016-09-28Original Equipment
AtoJhFBQvL774jFOdR1nmw==2016-09-28Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz0.41110.022ppm245KGXW22H
824.2-848.8 MHz0.38730.026ppm247KG7W22H
1850.2-1909.8 MHz0.37070.017ppm246KGXW24E
1850.2-1909.8 MHz0.36060.02ppm247KG7W24E
2412-2462 MHz0.006800015C

Grants

TCB Grant - Application XBZGyVrKpXfmaHFxTkOH3A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 09/28/2016

Application Dated: 09/27/2016
BLUE IDEA LIMITED
ROOMS 1318-19, 13/F, HOLLYWOOD PLAZA,
610 NATHAN ROAD, KOWLOON
HONG KONG,
China
 
Attention: Rosemary Kuang , Sales manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIQ2-V01
Name of Grantee:  BLUE IDEA LIMITED
Equipment Class: Digital Transmission System
Notes: SMART WATCH
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.0068  

Power listed is the maximum conducted output power. Device contains 20 and 40 MHz signal bandwidth.

EAS Grant - Application XBZGyVrKpXfmaHFxTkOH3A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

BLUE IDEA LIMITED
ROOMS 1318-19, 13/F, HOLLYWOOD PLAZA, 610 NATHAN ROAD, KOWLOON
HONG KONG,
China
  Date of Grant: 09/28/2016

Application Dated: 09/27/2016
 
Attention: Rosemary Kuang , Sales manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIQ2-V01
Name of Grantee:  BLUE IDEA LIMITED
Equipment Class: Digital Transmission System
Notes: SMART WATCH
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.0068  

Power listed is the maximum conducted output power. Device contains 20 and 40 MHz signal bandwidth.



TCB Grant - Application AtoJhFBQvL774jFOdR1nmw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 09/28/2016

Application Dated: 09/27/2016
BLUE IDEA LIMITED
ROOMS 1318-19, 13/F, HOLLYWOOD PLAZA,
610 NATHAN ROAD, KOWLOON
HONG KONG,
China
 
Attention: Rosemary Kuang , Sales manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIQ2-V01
Name of Grantee:  BLUE IDEA LIMITED
Equipment Class: PCS Licensed Transmitter held to face
Notes: SMART WATCH
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.4111 0.022  PM 245KGXW
22H 824.2  -  848.8 0.3873 0.026  PM 247KG7W
24E 1850.2  -  1909.8 0.3707 0.017  PM 246KGXW
24E 1850.2  -  1909.8 0.3606 0.02  PM 247KG7W

Output power listed is ERP for Part 22 and EIRP for Part 24. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations. For body worn operation, this phone has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the handset a minimum of 0 mm from the body, a minimum of 10mm next to mouth. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. Highest reported Wrist-worn SAR and Head SAR when held next to mouth are 0.94 W/Kg and 0.03 W/Kg respectively.

EAS Grant - Application AtoJhFBQvL774jFOdR1nmw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

BLUE IDEA LIMITED
ROOMS 1318-19, 13/F, HOLLYWOOD PLAZA, 610 NATHAN ROAD, KOWLOON
HONG KONG,
China
  Date of Grant: 09/28/2016

Application Dated: 09/27/2016
 
Attention: Rosemary Kuang , Sales manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIQ2-V01
Name of Grantee:  BLUE IDEA LIMITED
Equipment Class: PCS Licensed Transmitter held to face
Notes: SMART WATCH
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.4111 0.022  PM 245KGXW
22H 824.2  -  848.8 0.3873 0.026  PM 247KG7W
24E 1850.2  -  1909.8 0.3707 0.017  PM 246KGXW
24E 1850.2  -  1909.8 0.3606 0.02  PM 247KG7W

Output power listed is ERP for Part 22 and EIRP for Part 24. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations. For body worn operation, this phone has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the handset a minimum of 0 mm from the body, a minimum of 10mm next to mouth. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. Highest reported Wrist-worn SAR and Head SAR when held next to mouth are 0.94 W/Kg and 0.03 W/Kg respectively.



Mail To: