FCC ID 2AIUZ-HXWSG100R410

LoRaWAN Gateway

by Hexing Electrical Co.,Ltd

Grantee Code: 2AIUZ   Product Code: HXWSG100R410
Latest application date: 2026-07-02

FCC ID Device Details

FCC ID2AIUZ-HXWSG100R410
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AIUZ
Product CodeHXWSG100R410
Applicant BusinessHexing Electrical Co.,Ltd 🇨🇳
Related Domains hxgroup.co iconsigh.com
Equipment ClassLoRaWAN Gateway
Test FirmBay Area Compliance Laboratories Corp. (Kunshan)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.3-927.7 MHzOriginal Equipment2026-07-02
2412-2462 MHzOriginal Equipment2026-07-02

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2026-07-02PDF 827.8 KB
Internal PhotosInternal Photos2026-07-02PDF 2.5 MB
External PhotosExternal Photos2026-07-02PDF 1.1 MB
Label and Label LocationID Label/Location Info2026-07-02PDF 288.8 KB
Test Setup PhotosTest Setup Photos2026-07-02PDF 501.4 KB
Test Setup PhotosTest Setup Photos2026-07-02PDF 423.6 KB
Antenna SpecificationTest Report2026-07-02PDF 532.5 KB
Test ReportTest Report2026-07-02PDF 2.7 MB
Test ReportTest Report2026-07-02PDF 4.1 MB
Attestation LetterAttestation Statements2026-07-02PDF 502.3 KB
Attestation Letter-2.911(d)(5)(i)(ii)Attestation Statements2026-07-02PDF 467.9 KB
Professional Installation DeclarationAttestation Statements2026-07-02PDF 433.8 KB
US Agent Attestation LetterAttestation Statements2026-07-02PDF 285.3 KB
FCC Agent Authorization LetterCover Letter(s)2026-07-02PDF 253.6 KB
FCC Confidentiality LetterCover Letter(s)2026-07-02PDF 203.5 KB
RF Exposure InformationRF Exposure Info2026-07-02PDF 171.6 KB
Block Diagram Metadata onlyBlock DiagramPDF 501 KB
Schematics Metadata onlySchematicsPDF 4.5 MB
Operation Description Metadata onlyOperational DescriptionPDF 573.6 KB

Application Information

Application IDGAlbtpXksneShUqdJz9MtA==
Final Action Date2026-07-02
Application PurposeOriginal Equipment
Applicant FRN0025677535
ModelHXWSG100R410
Frequency Range902.3-927.7 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionLoRaWAN Gateway
Responsible PartyGang Wang, tech_117@hxgroup.co , 0571-28859173
Non-Technical ContactBenjamin Kaur, Iconsigh, benjamin.kaur@iconsigh.com , +1 (408) 320-9867
Test FirmJohn Chan, Bay Area Compliance Laboratories Corp. (Kunshan), qa.ks@baclcorp.com , 86-512-86175000
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
GAlbtpXksneShUqdJz9MtA==2026-07-02Original Equipment
Ey7959jpHGusrIIeNrqUGw==2026-07-02Original Equipment

Equipment Authorization

FrequencyOutputRules
902.3-927.7 MHz0.08415C
2412-2462 MHz0.04215C

Grants

TCB Grant - Application GAlbtpXksneShUqdJz9MtA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratories Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 07/02/2026

Application Dated: 07/02/2026
Hexing Electrical Co.,Ltd
1418 moganshan Road
shangcheng Industrial Zone
Hangzhou, 310011
China
 
Attention: Gang Wang ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIUZ-HXWSG100R410
Name of Grantee:  Hexing Electrical Co.,Ltd
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: LoRaWAN Gateway
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.3  -  927.7 0.084  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device must be professionally installed.

TCB Grant - Application Ey7959jpHGusrIIeNrqUGw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratories Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 07/02/2026

Application Dated: 07/02/2026
Hexing Electrical Co.,Ltd
1418 moganshan Road
shangcheng Industrial Zone
Hangzhou, 310011
China
 
Attention: Gang Wang ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIUZ-HXWSG100R410
Name of Grantee:  Hexing Electrical Co.,Ltd
Equipment Class: Digital Transmission System
Notes: LoRaWAN Gateway
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.042  

Output power listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device must be professionally installed.