FCC ID 2AIZN-X6887

Mobile Phone

by INFINIX MOBILITY LIMITED

Grantee Code: 2AIZN   Product Code: X6887
Latest application date: 2025-12-31

FCC ID Device Details

FCC ID2AIZN-X6887
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AIZN
Product CodeX6887
Applicant BusinessINFINIX MOBILITY LIMITED
Related Domains infinixmobility.com picus.fi
Equipment ClassMobile Phone
Test FirmShanghai Tejet Communications Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2025-12-31
3705-3975 MHzOriginal Equipment2025-12-31
5745-5825 MHzOriginal Equipment2025-12-31
2412-2462 MHzOriginal Equipment2025-12-31
13.56 MHzOriginal Equipment2025-12-31

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2026-06-28PDF 444.3 KB
Internal PhotosInternal Photos2026-06-28PDF 3.2 MB
External PhotosExternal Photos2026-06-28PDF 1.5 MB
ID Label/Location InfoID Label/Location Info2025-12-31PDF 134.6 KB
Test Setup Photos_DXXTest Setup Photos2026-06-28PDF 1.9 MB
Test Setup Photos_JBPTest Setup Photos2026-06-28PDF 2 MB
Test Setup Photos_NIITest Setup Photos2026-06-28PDF 1.1 MB
Test Setup Photos_PCETest Setup Photos2026-06-28PDF 535 KB
Test Setup Photos_SARTest Setup Photos2026-06-28PDF 263.9 KB
ANTTest Report2025-12-31PDF 3.8 MB
BLE_test reportTest Report2025-12-31PDF 4.3 MB
BLE_test report_min_Part1Test Report2025-12-31PDF 5.2 MB
BT_test reportTest Report2025-12-31PDF 5.3 MB
BT_test report_min_Part1Test Report2025-12-31PDF 5 MB
BT_test report_min_Part2Test Report2025-12-31PDF 4.2 MB
Data Part 1Test Report2025-12-31PDF 1.4 MB
Data Part 1Test Report2025-12-31PDF 3 MB
Data Part 2Test Report2025-12-31PDF 983.1 KB
Data Part 2-1Test Report2025-12-31PDF 4.3 MB
Data Part 2-10Test Report2025-12-31PDF 4.6 MB
Data Part 2-11Test Report2025-12-31PDF 4.6 MB
Data Part 2-12Test Report2025-12-31PDF 4.6 MB
Data Part 2-13Test Report2025-12-31PDF 4.6 MB
Data Part 2-14Test Report2025-12-31PDF 4.6 MB
Data Part 2-15Test Report2025-12-31PDF 4.6 MB
Data Part 2-16Test Report2025-12-31PDF 4.6 MB
Data Part 2-17Test Report2025-12-31PDF 4.6 MB
Data Part 2-18Test Report2025-12-31PDF 4.6 MB
Data Part 2-19Test Report2025-12-31PDF 4.4 MB
Data Part 2-2Test Report2025-12-31PDF 4.6 MB
Data Part 2-3Test Report2025-12-31PDF 4.6 MB
Data Part 2-4Test Report2025-12-31PDF 4.6 MB
Data Part 2-5Test Report2025-12-31PDF 4.6 MB
Data Part 2-6Test Report2025-12-31PDF 4.6 MB
Data Part 2-7Test Report2025-12-31PDF 4.6 MB
Data Part 2-8Test Report2025-12-31PDF 3.8 MB
Data Part 2-9Test Report2025-12-31PDF 4.6 MB
Data Part 3Test Report2025-12-31PDF 3 MB
Data Part 3-1Test Report2025-12-31PDF 3.3 MB
Data Part 3-10Test Report2025-12-31PDF 5 MB
Data Part 3-11Test Report2025-12-31PDF 4.9 MB
Data Part 3-12Test Report2025-12-31PDF 4.9 MB
Data Part 3-13Test Report2025-12-31PDF 4.9 MB
Data Part 3-14Test Report2025-12-31PDF 4.9 MB
Data Part 3-15Test Report2025-12-31PDF 5 MB
Data Part 3-16Test Report2025-12-31PDF 2.4 MB
Data Part 3-2Test Report2025-12-31PDF 4.9 MB
Data Part 3-3Test Report2025-12-31PDF 4.9 MB
Data Part 3-4Test Report2025-12-31PDF 4.9 MB
Data Part 3-5Test Report2025-12-31PDF 4.9 MB
Data Part 3-6Test Report2025-12-31PDF 4.9 MB
Data Part 3-7Test Report2025-12-31PDF 4.9 MB
Data Part 3-8Test Report2025-12-31PDF 4.9 MB
Data Part 3-9Test Report2025-12-31PDF 4.9 MB
Data Part 4Test Report2025-12-31PDF 4.4 MB
Data Part 5-1Test Report2025-12-31PDF 4.3 MB
Data Part 5-10Test Report2025-12-31PDF 1.8 MB
Data Part 5-2Test Report2025-12-31PDF 4.6 MB
Data Part 5-3Test Report2025-12-31PDF 4.9 MB
Data Part 5-5Test Report2025-12-31PDF 4.5 MB
Data Part 5-6Test Report2025-12-31PDF 4.4 MB
Data Part 5-7Test Report2025-12-31PDF 4.3 MB
Data Part 5-8Test Report2025-12-31PDF 4.3 MB
Data Part 5-9Test Report2025-12-31PDF 3.3 MB
Data Part 6-1Test Report2025-12-31PDF 2.9 MB
Data Part 6-10Test Report2025-12-31PDF 2.6 MB
Data Part 6-2Test Report2025-12-31PDF 3.9 MB
Data Part 6-3Test Report2025-12-31PDF 4.3 MB
Data Part 6-4Test Report2025-12-31PDF 4.5 MB
Data Part 6-6Test Report2025-12-31PDF 4.8 MB
Data Part 6-7Test Report2025-12-31PDF 4.5 MB
Data Part 6-8Test Report2025-12-31PDF 4.4 MB
Data Part 6-9Test Report2025-12-31PDF 3.8 MB
Data Part 7-1Test Report2025-12-31PDF 4.6 MB
Data Part 7-2Test Report2025-12-31PDF 4.8 MB
Data Part 7-3Test Report2025-12-31PDF 3.6 MB
PCE test reportTest Report2025-12-31PDF 1.1 MB
SAR test reportRF Exposure Info2025-12-31PDF 3.3 MB
Test Report_DFSTest Report2025-12-31PDF 1.8 MB
Test Report_DXXTest Report2025-12-31PDF 1.5 MB
Test Report_JBPTest Report2025-12-31PDF 1.8 MB
Test Report_NIITest Report2025-12-31PDF 3.7 MB
WIFI_test reportTest Report2025-12-31PDF 4 MB
WIFI_test report_min_Part1Test Report2025-12-31PDF 4.5 MB
Attestation Letter COVERED EQUIPMENTAttestation Statements2025-12-31PDF 116.9 KB
US agentAttestation Statements2025-12-31PDF 144.2 KB
Authorization LetterCover Letter(s)2025-12-31PDF 79.2 KB
Confidentiality Request LetterCover Letter(s)2025-12-31PDF 80.6 KB
BL-SH25A1131-ACRF Exposure Info2025-12-31PDF 5.5 MB
BL-SH25A1131-APRF Exposure Info2025-12-31PDF 1 MB
BL-SH25A1131-ASCRF Exposure Info2025-12-31PDF 1.9 MB
BL-SH25A1131-ASTRF Exposure Info2025-12-31PDF 1.2 MB
BL-SH25A1131-ATDRF Exposure Info2025-12-31PDF 2.4 MB
Block Diagram Metadata onlyBlock DiagramPDF 107.9 KB
Schematics Metadata onlySchematicsPDF 278.3 KB
DTS_Software Configuration Control declaration Metadata onlyOperational DescriptionPDF 145.7 KB
Operational Description Metadata onlyOperational DescriptionPDF 110.3 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 621.5 KB
Tune-Up Procedure Metadata onlyParts List/Tune Up InfoPDF 1 MB

Application Information

Application IDsxn4oXhOBoBEXRH6mttHug==
Final Action Date2025-12-31
Application PurposeOriginal Equipment
Applicant FRN0025707605
ModelX6887
Equipment ClassJBP - Part 15 Class B Computing Device Peripheral
Device DescriptionMobile Phone
Responsible PartyJerry Liu, jerry.liu@infinixmobility.com , +86-0755-61803856
Technical Contactxuewen wu, Shenzhen BALUN Technology Co., Ltd, cbproject@baluntek.com , 86-755-66850100
Non-Technical Contactlvan Wang, Picus Advisors US LLC, ivan.wang@picus.fi , (713) 391-4488
Test FirmCarol Duan, Shanghai Tejet Communications Technology Co., Ltd., xiaohong.duan@titcgroup.com , 86-021-58180736
TCB Emaildl_radio-certification@kiwa.com
TCB ScopeA1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
sxn4oXhOBoBEXRH6mttHug==2025-12-31Original Equipment
cKn1XyC5ThaFXMH4CS5hag==2025-12-31Original Equipment
SaWruluWMtN2935xupf88Q==2025-12-31Original Equipment
PsdHADs2bNA9SdBrJMwa5A==2025-12-31Original Equipment
LQl5F+XG5PkiHK4komokGQ==2025-12-31Original Equipment
JaIXVhgM0ehkP72Lb9ONDQ==2025-12-31Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
15BCC
824.2-848.8 MHz0.2662.5 PM247KGXW22H
1850.2-1909.8 MHz0.7872.5 PM246KGXW24E
1852.4-1907.6 MHz0.1452.5 PM4M14F9W24E
1712.4-1752.6 MHz0.1072.5 PM4M14F9W27
826.4-846.6 MHz0.0662.5 PM4M14F9W22H
1850.7-1909.3 MHz0.1172.5 PM18M0G7D24E
1850.7-1909.3 MHz0.1032.5 PM18M0G7D24E
1850.7-1909.3 MHz0.1182.5 PM4M51W7D24E
1850.7-1909.3 MHz0.1042.5 PM4M51W7D24E
1710.7-1754.3 MHz0.1362.5 PM18M0G7D27
1710.7-1754.3 MHz0.122.5 PM18M0W7D27
1710.7-1754.3 MHz0.1382.5 PM5M50G7D27
1710.7-1754.3 MHz0.1192.5 PM13M5W7D27
824.7-848.3 MHz0.0542.5 PM8M99G7D22H
824.7-848.3 MHz0.0462.5 PM9M00W7D22H
824.7-848.3 MHz0.0482.5 PM4M51W7D22H
2502.5-2567.5 MHz0.0922.5 PM18M0G7D27
2502.5-2567.5 MHz0.0832.5 PM18M0W7D27
2502.5-2567.5 MHz0.0942.5 PM4M51G7D27
2502.5-2567.5 MHz0.0792.5 PM13M5W7D27
699.7-715.3 MHz0.0422.5 PM8M99G7D27
699.7-715.3 MHz0.0362.5 PM9M00W7D27
699.7-715.3 MHz0.0372.5 PM4M51W7D27
779.5-784.5 MHz0.0442.5 PM9M00G7D27
779.5-784.5 MHz0.0342.5 PM8M97W7D27
706.5-713.5 MHz0.0422.5 PM8M97G7D27
706.5-713.5 MHz0.0352.5 PM8M97W7D27
706.5-713.5 MHz0.0342.5 PM4M51W7D27
2572.5-2617.5 MHz0.1572.5 PM18M0G7D27
2572.5-2617.5 MHz0.1332.5 PM18M0W7D27
2572.5-2617.5 MHz0.1362.5 PM13M5W7D27
2498.5-2687.5 MHz0.1552.5 PM18M0G7D27
2498.5-2687.5 MHz0.1322.5 PM18M0W7D27
2498.5-2687.5 MHz0.1592.5 PM4M50G7D27
2498.5-2687.5 MHz0.1322.5 PM9M02W7D27
3452.5-3547.5 MHz0.052.5 PM18M0G7D27
3452.5-3547.5 MHz0.0452.5 PM18M0W7D27
3452.5-3547.5 MHz0.0532.5 PM4M49G7D27
3452.5-3547.5 MHz0.0462.5 PM9M00W7D27
1710.7-1779.3 MHz0.1422.5 PM18M0G7D27
1710.7-1779.3 MHz0.1252.5 PM18M0W7D27
826.5-846.5 MHz0.0452.5 PM18M9G7D22H
826.5-846.5 MHz0.0352.5 PM18M9W7D22H
826.5-846.5 MHz0.0352.5 PM14M1W7D22H
2502.5-2567.5 MHz0.0852.5 PM18M9G7D27
2502.5-2567.5 MHz0.0652.5 PM18M9W7D27
2502.5-2567.5 MHz0.0642.5 PM14M1W7D27
701.5-713.5 MHz0.0382.5 PM14M1G7D27
701.5-713.5 MHz0.0292.5 PM14M1W7D27
2575-2615 MHz0.0812.5 PM18M2G7D27
2575-2615 MHz0.0632.5 PM18M2W7D27
2575-2615 MHz0.0622.5 PM13M6W7D27
2501.01-2685 MHz0.1142.5 PM97M5G7D27
2501.01-2685 MHz0.0842.5 PM97M8W7D27
2501.01-2685 MHz0.0862.5 PM47M7W7D27
1712.5-1777.5 MHz0.0772.5 PM38M9G7D27
1712.5-1777.5 MHz0.0612.5 PM38M8W7D27
1712.5-1777.5 MHz0.0792.5 PM18M9G7D27
1712.5-1777.5 MHz0.062.5 PM18M9W7D27
3455.01-3544.995 MHz0.0852.5 PM97M5G7D27
3455.01-3544.995 MHz0.0652.5 PM97M7W7D27
3705-3975 MHz0.0642.5 PM47M7W7D27
3705-3975 MHz0.072.5 PM97M5G7D27
3705-3975 MHz0.0532.5 PM97M7W7D27
3705-3975 MHz0.0522.5 PM47M7W7D27
3455.01-3544.995 MHz0.0812.5 PM97M5G7D27
3455.01-3544.995 MHz0.0632.5 PM97M7W7D27
3455.01-3544.995 MHz0.0642.5 PM47M7W7D27
3705-3975 MHz0.072.5 PM97M4G7D27
3705-3975 MHz0.0562.5 PM97M7W7D27
3705-3975 MHz0.0782.5 PM8M56G7D27
3705-3975 MHz0.062.5 PM8M57W7D27
5180-5240 MHz0.03615ECC
5260-5320 MHz0.03915ECC ND
5500-5700 MHz0.03615ECC ND
5745-5825 MHz0.03715ECC
2402-2480 MHz0.0005615CCC
2412-2462 MHz0.2915CCC
13.56 MHz15CCC
2402-2480 MHz0.02815CCC

Grants

TCB Grant - Application sxn4oXhOBoBEXRH6mttHug==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/31/2025

Application Dated: 12/30/2025
INFINIX MOBILITY LIMITED
FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL
CENTRE 19-25 SHAN MEI STREET FOTAN
NT,
Hong Kong
 
Attention: Jerry Liu ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIZN-X6887
Name of Grantee:  INFINIX MOBILITY LIMITED
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application SaWruluWMtN2935xupf88Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/31/2025

Application Dated: 12/30/2025
INFINIX MOBILITY LIMITED
FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL
CENTRE 19-25 SHAN MEI STREET FOTAN
NT,
Hong Kong
 
Attention: Jerry Liu ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIZN-X6887
Name of Grantee:  INFINIX MOBILITY LIMITED
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.266 2.5  PM 247KGXW
24E 1850.2  -  1909.8 0.787 2.5  PM 246KGXW
24E 1852.4  -  1907.6 0.145 2.5  PM 4M14F9W
27 1712.4  -  1752.6 0.107 2.5  PM 4M14F9W
22H 826.4  -  846.6 0.066 2.5  PM 4M14F9W
24E 1850.7  -  1909.3 0.117 2.5  PM 18M0G7D
24E 1850.7  -  1909.3 0.103 2.5  PM 18M0G7D
24E 1850.7  -  1909.3 0.118 2.5  PM 4M51W7D
24E 1850.7  -  1909.3 0.104 2.5  PM 4M51W7D
27 1710.7  -  1754.3 0.136 2.5  PM 18M0G7D
27 1710.7  -  1754.3 0.12 2.5  PM 18M0W7D
27 1710.7  -  1754.3 0.138 2.5  PM 5M50G7D
27 1710.7  -  1754.3 0.119 2.5  PM 13M5W7D
22H 824.7  -  848.3 0.054 2.5  PM 8M99G7D
22H 824.7  -  848.3 0.046 2.5  PM 9M00W7D
22H 824.7  -  848.3 0.048 2.5  PM 4M51W7D
27 2502.5  -  2567.5 0.092 2.5  PM 18M0G7D
27 2502.5  -  2567.5 0.083 2.5  PM 18M0W7D
27 2502.5  -  2567.5 0.094 2.5  PM 4M51G7D
27 2502.5  -  2567.5 0.079 2.5  PM 13M5W7D
27 699.7  -  715.3 0.042 2.5  PM 8M99G7D
27 699.7  -  715.3 0.036 2.5  PM 9M00W7D
27 699.7  -  715.3 0.037 2.5  PM 4M51W7D
27 779.5  -  784.5 0.044 2.5  PM 9M00G7D
27 779.5  -  784.5 0.034 2.5  PM 8M97W7D
27 706.5  -  713.5 0.042 2.5  PM 8M97G7D
27 706.5  -  713.5 0.035 2.5  PM 8M97W7D
27 706.5  -  713.5 0.034 2.5  PM 4M51W7D
27 2572.5  -  2617.5 0.157 2.5  PM 18M0G7D
27 2572.5  -  2617.5 0.133 2.5  PM 18M0W7D
27 2572.5  -  2617.5 0.136 2.5  PM 13M5W7D
27 2498.5  -  2687.5 0.155 2.5  PM 18M0G7D
27 2498.5  -  2687.5 0.132 2.5  PM 18M0W7D
27 2498.5  -  2687.5 0.159 2.5  PM 4M50G7D
27 2498.5  -  2687.5 0.132 2.5  PM 9M02W7D
27 3452.5  -  3547.5 0.05 2.5  PM 18M0G7D
27 3452.5  -  3547.5 0.045 2.5  PM 18M0W7D
27 3452.5  -  3547.5 0.053 2.5  PM 4M49G7D
27 3452.5  -  3547.5 0.046 2.5  PM 9M00W7D
27 1710.7  -  1779.3 0.142 2.5  PM 18M0G7D
27 1710.7  -  1779.3 0.125 2.5  PM 18M0W7D
22H 826.5  -  846.5 0.045 2.5  PM 18M9G7D
22H 826.5  -  846.5 0.035 2.5  PM 18M9W7D
22H 826.5  -  846.5 0.035 2.5  PM 14M1W7D
27 2502.5  -  2567.5 0.085 2.5  PM 18M9G7D
27 2502.5  -  2567.5 0.065 2.5  PM 18M9W7D
27 2502.5  -  2567.5 0.064 2.5  PM 14M1W7D
27 701.5  -  713.5 0.038 2.5  PM 14M1G7D
27 701.5  -  713.5 0.029 2.5  PM 14M1W7D
27 2575.0  -  2615.0 0.081 2.5  PM 18M2G7D
27 2575.0  -  2615.0 0.063 2.5  PM 18M2W7D
27 2575.0  -  2615.0 0.062 2.5  PM 13M6W7D
27 2501.01  -  2685.0 0.114 2.5  PM 97M5G7D
27 2501.01  -  2685.0 0.084 2.5  PM 97M8W7D
27 2501.01  -  2685.0 0.086 2.5  PM 47M7W7D
27 1712.5  -  1777.5 0.077 2.5  PM 38M9G7D
27 1712.5  -  1777.5 0.061 2.5  PM 38M8W7D
27 1712.5  -  1777.5 0.079 2.5  PM 18M9G7D
27 1712.5  -  1777.5 0.06 2.5  PM 18M9W7D
27 3455.01  -  3544.995 0.085 2.5  PM 97M5G7D
27 3455.01  -  3544.995 0.065 2.5  PM 97M7W7D
27 3705.0  -  3975.0 0.064 2.5  PM 47M7W7D
27 3705.0  -  3975.0 0.07 2.5  PM 97M5G7D
27 3705.0  -  3975.0 0.053 2.5  PM 97M7W7D
27 3705.0  -  3975.0 0.052 2.5  PM 47M7W7D
27 3455.01  -  3544.995 0.081 2.5  PM 97M5G7D
27 3455.01  -  3544.995 0.063 2.5  PM 97M7W7D
27 3455.01  -  3544.995 0.064 2.5  PM 47M7W7D
27 3705.0  -  3975.0 0.07 2.5  PM 97M4G7D
27 3705.0  -  3975.0 0.056 2.5  PM 97M7W7D
27 3705.0  -  3975.0 0.078 2.5  PM 8M56G7D
27 3705.0  -  3975.0 0.06 2.5  PM 8M57W7D

Power Output is ERP for part 22, 90 and 27(Below 1GHz) and EIRP for Part 24 and 27(Above 1GHz). SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.

The highest reported SAR values for head, body-worn accessory, product specific (hotspot), and simultaneous transmission use conditions are 1.19 W/kg, 0.76 W/kg, 0.96 W/kg,  and 1.59 W/kg, respectively. 

The device supports GSM Band 2/5, WCDMA Band 2/4/5, and FDD LTE Band 2/4/5/7/12/13/17/66, TDD LTE Band 38/41/42, 5G SA Band n5/n7/n12/n38/n41/n66/n77/n78.

Channel Bandwidth (1.4/3/5/10/15/20 MHz) for LTE B2, B4, B66,

Channel Bandwidth (1.4/3/5/10 MHz) for LTE B5, B12,

Channel Bandwidth (5/10/15/20 MHz) for LTE B7, B38, B41, B42,

Channel Bandwidth (5/10 MHz) for LTE B13, B17.


TCB Grant - Application PsdHADs2bNA9SdBrJMwa5A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/31/2025

Application Dated: 12/30/2025
INFINIX MOBILITY LIMITED
FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL
CENTRE 19-25 SHAN MEI STREET FOTAN
NT,
Hong Kong
 
Attention: Jerry Liu ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIZN-X6887
Name of Grantee:  INFINIX MOBILITY LIMITED
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.036  
CC ND 15E 5260.0  -  5320.0 0.039  
CC ND 15E 5500.0  -  5700.0 0.036  
CC 15E 5745.0  -  5825.0 0.037  

Power output listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.

The highest reported SAR values for head, body-worn accessory, product specific (hotspot), simultaneous transmission and extremity use conditions are 0.35 W/kg, 0.11 W/kg, 0.37 W/kg, 1.56 W/kg and 0.39 W/kg, respectively.

This device supports 20 MHz, 40 MHz and 80 MHz bandwidth modes. The 80 MHz modes are limited to channel at 5210MHz, 5290 MHz, 5530 MHz, 5610 MHz and 5775 MHz.


CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application LQl5F+XG5PkiHK4komokGQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/31/2025

Application Dated: 12/30/2025
INFINIX MOBILITY LIMITED
FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL
CENTRE 19-25 SHAN MEI STREET FOTAN
NT,
Hong Kong
 
Attention: Jerry Liu ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIZN-X6887
Name of Grantee:  INFINIX MOBILITY LIMITED
Equipment Class: Digital Transmission System
Notes: Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00056  
CC 15C 2412.0  -  2462.0 0.29  

Power output listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.

The highest reported SAR values for head, body-worn accessory, product specific (hotspot), and simultaneous transmission use conditions are 0.38 W/kg, 0.13 W/kg, 0.13 W/kg and 1.59 W/kg, respectively.

This device has 20 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application JaIXVhgM0ehkP72Lb9ONDQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/31/2025

Application Dated: 12/30/2025
INFINIX MOBILITY LIMITED
FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL
CENTRE 19-25 SHAN MEI STREET FOTAN
NT,
Hong Kong
 
Attention: Jerry Liu ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIZN-X6887
Name of Grantee:  INFINIX MOBILITY LIMITED
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application cKn1XyC5ThaFXMH4CS5hag==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 12/31/2025

Application Dated: 12/30/2025
INFINIX MOBILITY LIMITED
FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL
CENTRE 19-25 SHAN MEI STREET FOTAN
NT,
Hong Kong
 
Attention: Jerry Liu ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIZN-X6887
Name of Grantee:  INFINIX MOBILITY LIMITED
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.028  

Power output listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.

The highest reported SAR values for head, body-worn accessory, product specific (hotspot) and simultaneous transmission  use conditions are 0.21 W/kg, <0.10 W/kg, <0.10 W/kg and 1.59 W/kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.