FCC ID 2AJ3K-990-04082-00
Wearable Vital Signs Monitor
by Verily Life Sciences LLC
Grantee Code: 2AJ3K Product Code: 9900408200
Latest application date: 2020-12-17
FCC ID Device Details
| FCC ID | 2AJ3K-990-04082-00 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AJ3K |
| Product Code | 9900408200 |
| Applicant Business | Verily Life Sciences LLC 🇺🇸 |
| Related Domains | |
| Equipment Class | Wearable Vital Signs Monitor |
| Test Firm | UL Verification Services Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2020-12-17 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| 953-00791-01 LIT, Instructions for Use [IFU], MAIN BOX, tPatch2 P1.3 | Users Manual | 2021-06-15 | PDF 1.3 MB |
| Confidentiality request internal photos | Cover Letter(s) | 2020-12-17 | PDF 1.7 MB |
| External Photos | External Photos | 2021-06-15 | PDF 713.3 KB |
| ID_Label Location | ID Label/Location Info | 2020-12-17 | PDF 278.1 KB |
| 13461097-E2V2 FCC SetUp Photos BLE | Test Setup Photos | 2021-06-15 | PDF 500.1 KB |
| 13461097-E2V2 FCC Test Report BLE | Test Report | 2020-12-17 | PDF 2.8 MB |
| FCC Agent Authorization Letter - Signed | Cover Letter(s) | 2020-12-17 | PDF 116.4 KB |
| FCC Request for Confidentiality Letter - Signed | Cover Letter(s) | 2020-12-17 | PDF 152 KB |
| Signatory authorisation | Cover Letter(s) | 2020-12-17 | PDF 206.4 KB |
| 13461097-E5V3 FCC SAR Exclusion Report Final | RF Exposure Info | 2020-12-17 | PDF 198.3 KB |
| Internal Photos Metadata only | Internal Photos | PDF 1.2 MB | |
| Block Diagram_rev1 Metadata only | Block Diagram | PDF 164.6 KB | |
| 650-02895-01-SCH_Rev01_Main_tPatch2_12 Metadata only | Schematics | PDF 442.1 KB | |
| Antenna Description Metadata only | Operational Description | PDF 539.3 KB | |
| Operational Description_rev1 Metadata only | Operational Description | PDF 325.2 KB |
Application Information
| Application ID | iLtMowYMc7wkCI4pNOsidA== |
|---|---|
| Final Action Date | 2020-12-17 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0025967647 |
| Model | 990-04082-00 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Wearable Vital Signs Monitor |
| Responsible Party | Cynthia Patton, General Counsel, cynthiapatton@verily.com |
| Agent | Sol Sol Sol, UL Verification Services Inc., soledad.u.kuwatani@ul.com |
| Technical Contact | Sol Kuwatani, UL Verification Services Inc., soledad.u.kuwatani@ul.com |
| Test Firm | Jay Kogoma, UL Verification Services Inc., jay.kogoma@ul.com |
| TCB Email | LST.FRE.CertNotice@ul.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 06/15/2021 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
| Grant Comments | Output power listed is conducted power. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| iLtMowYMc7wkCI4pNOsidA== | 2020-12-17 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2402-2480 MHz | 0.0070000 | 15C |
Grants
TCB Grant - Application iLtMowYMc7wkCI4pNOsidA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 12/17/2020 Application Dated: 12/15/2020 |
| Verily Life Sciences LLC |
| 269 East Grand Ave. |
| South San Francisco, CA 94080 |
| Attention: Cynthia Patton , General Counsel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AJ3K-990-04082-00 |
| Name of Grantee: | Verily Life Sciences LLC |
| Equipment Class: | Digital Transmission System |
| Notes: | Wearable Vital Signs Monitor |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.007 |
| Output power listed is conducted power. |
EAS Grant - Application iLtMowYMc7wkCI4pNOsidA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Verily Life Sciences LLC 269 East Grand Ave. South San Francisco, CA 94080 United States |
Date of Grant: 12/17/2020 Application Dated: 12/15/2020 |
| Attention: Cynthia Patton , General Counsel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AJ3K-990-04082-00 |
| Name of Grantee: | Verily Life Sciences LLC |
| Equipment Class: | Digital Transmission System |
| Notes: | Wearable Vital Signs Monitor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.007 |
| Output power listed is conducted power. |
| Mail To: |