FCC ID 2AJEM-HY757
Alarm System
by Shenzhen Macross Industrial Co., Ltd.
Grantee Code: 2AJEM Product Code: HY757
Latest application date: 2018-04-03
FCC ID Device Details
| FCC ID | 2AJEM-HY757 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AJEM |
| Product Code | HY757 |
| Applicant Business | Shenzhen Macross Industrial Co., Ltd. 🇨🇳 |
| Equipment Class | Alarm System |
| Test Firm | Shenzhen CTL Testing Technology Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 462.563-462.713 MHz | Original Equipment | 2018-04-03 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2018-04-03 | PDF 3.3 MB |
| Internal Photos | Internal Photos | 2018-04-03 | PDF 210.2 KB |
| External Photos | External Photos | 2018-04-03 | PDF 326.3 KB |
| ID Label/Location Info | ID Label/Location Info | 2018-04-03 | PDF 122.5 KB |
| Test Setup Photos | Test Setup Photos | 2018-04-03 | PDF 113.7 KB |
| Test Report | Test Report | 2018-04-03 | PDF 1.1 MB |
| Declaration of authorization | Cover Letter(s) | 2018-04-03 | PDF 12.7 KB |
| confidentiality | Cover Letter(s) | 2018-04-03 | PDF 17.8 KB |
| MPE | RF Exposure Info | 2018-04-03 | PDF 70.1 KB |
| Block diagram Metadata only | Block Diagram | PDF 190.4 KB | |
| Schematics Metadata only | Schematics | PDF 69.6 KB | |
| Operational Description Metadata only | Operational Description | PDF 128.5 KB | |
| Part List_BOM Metadata only | Parts List/Tune Up Info | PDF 76.3 KB |
Application Information
| Application ID | 8ceHLruFdn88WMLf9Cf11A== |
|---|---|
| Final Action Date | 2018-04-03 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0025796970 |
| Model | HY757 |
| Frequency Range | 462.563-462.713 MHz |
| Equipment Class | FRT - Part 95 Family Radio Body Worn Transmitter |
| Device Description | Alarm System |
| Responsible Party | William King, Manager, Williamwang18@outlook.com |
| Technical Contact | William King, Shenzhen Macross Industrial Co., Ltd., Williamwang18@outlook.com |
| Non-Technical Contact | William King, Shenzhen Macross Industrial Co., Ltd., Williamwang18@outlook.com |
| Test Firm | Tracy Qi, Shenzhen CTL Testing Technology Co., Ltd., qihui@ctl-lab.com |
| TCB Email | certification@telefication.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 8ceHLruFdn88WMLf9Cf11A== | 2018-04-03 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application 8ceHLruFdn88WMLf9Cf11A==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Telefication B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 04/03/2018 Application Dated: 04/02/2018 |
| Shenzhen Macross Industrial Co., Ltd. |
| 3rd floor,#5 Building,Jianghao Technology Park |
| #430 Jihua Rd.Bantian St.Longgang District |
| Shenzhen, Guangdong, China |
| Attention: William King , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AJEM-HY757 |
| Name of Grantee: | Shenzhen Macross Industrial Co., Ltd. |
| Equipment Class: | Part 95 Family Radio Body Worn Transmitter |
| Notes: | Alarm System |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95B | 462.5625 - 462.7125 | 0.446 | 0.000117 % | 10K5F3E |
| Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application 8ceHLruFdn88WMLf9Cf11A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Macross Industrial Co., Ltd. 3rd floor,#5 Building,Jianghao Technology Park #430 Jihua Rd.Bantian St.Longgang District Shenzhen, Guangdong, China |
Date of Grant: 04/03/2018 Application Dated: 04/02/2018 |
| Attention: William King , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AJEM-HY757 |
| Name of Grantee: | Shenzhen Macross Industrial Co., Ltd. |
| Equipment Class: | Part 95 Family Radio Body Worn Transmitter |
| Notes: | Alarm System |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95B | 462.5625 - 462.7125 | 0.446 | 0.000117 % | 10K5F3E |
| Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |