FCC ID 2AJG4-FH-V1-4G

FH Emergency Device - V1-4G

by Universal Physicians, LLC

Grantee Code: 2AJG4   Product Code: FHV14G
Latest application date: 2021-03-09

FCC ID Device Details

FCC ID2AJG4-FH-V1-4G
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AJG4
Product CodeFHV14G
Applicant BusinessUniversal Physicians, LLC 🇺🇸
Related Domains uphealthusa.com
Equipment ClassFH Emergency Device - V1-4G
Test FirmShenzhen Tongzhou Testing Co., LTD

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
699-716 MHzOriginal Equipment2021-03-09

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2021-03-09PDF 2.9 MB
Internal PhotosInternal Photos2021-03-09PDF 1.5 MB
External PhotosExternal Photos2021-03-09PDF 856.4 KB
Label and Label LocationID Label/Location Info2021-03-09PDF 393.7 KB
Test Setup PhotosTest Setup Photos2021-03-09PDF 337.8 KB
Appendix Test Data for LTE Band12Test Report2021-03-09PDF 4.2 MB
Appendix Test Data for LTE Band17Test Report2021-03-09PDF 1.7 MB
Appendix Test Data for LTE Band25_Part1Test Report2021-03-09PDF 3.9 MB
Appendix Test Data for LTE Band25_Part2Test Report2021-03-09PDF 2.6 MB
Appendix Test Data for LTE Band4_Part1Test Report2021-03-09PDF 4 MB
Appendix Test Data for LTE Band4_Part2Test Report2021-03-09PDF 2.2 MB
Appendix Test Data for LTE Band7Test Report2021-03-09PDF 2.2 MB
Appendix Test data for LTE Band2_Part1Test Report2021-03-09PDF 4 MB
Appendix Test data for LTE Band2_Part2Test Report2021-03-09PDF 2.6 MB
Test report-GSMTest Report2021-03-09PDF 2.1 MB
Test report-LTETest Report2021-03-09PDF 1,014.1 KB
FCC Confidentiality request letterCover Letter(s)2021-03-09PDF 109.8 KB
FCC POACover Letter(s)2021-03-09PDF 71.3 KB
CALIBRATION DATARF Exposure Info2021-03-09PDF 3.9 MB
RF Exposure-SAR ReportRF Exposure Info2021-03-09PDF 5.3 MB
Block Diagram Metadata onlyBlock DiagramPDF 268 KB
Schematic Metadata onlySchematicsPDF 917.5 KB
Operation description Metadata onlyOperational DescriptionPDF 118.2 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 106.5 KB
Tune up Info Metadata onlyParts List/Tune Up InfoPDF 84.2 KB

Application Information

Application IDUikU8L7TwnBbINNThXDKjw==
Final Action Date2021-03-09
Application PurposeOriginal Equipment
Applicant FRN0025814682
ModelFH-V1-4G
Frequency Range699-716 MHz
Equipment ClassPCT - PCS Licensed Transmitter worn on body
Device DescriptionFH Emergency Device - V1-4G
Responsible PartyShelly R Hufford, Vice President, shufford@uphealthusa.com , 330 966-4735
Test FirmAndy Zhang, Shenzhen Tongzhou Testing Co., LTD, Andy.Zhang@sztz-testing.com , +86-755-32902198
TCB Emailjoergkusig@eurofins.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is ERP below 1GHz and EIRP above 1GHz. This device supports LTE bandwidths of 1.4/3/5 MHz at LTE Band 2/4/12/25 and bandwidths of 5MHz at LTE Band 7/17. This device contains functions that are not operational in U.S. and its territories. Filings under this FCC ID are approved only for U.S. operations. For body worn operation, the FH Emergency Device - V1-4G has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the device a minimum of 0 mm from the body.Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for body-worn accessory use conditions is 1.44 W/kg.

Applications

Application IDDatePurpose
UikU8L7TwnBbINNThXDKjw==2021-03-09Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
699-716 MHz0.01142.5ppm4M60G7D27
699-716 MHz0.00912.5ppm4M61W7D27
704-716 MHz0.00812.5ppm4M63G7D27
704-716 MHz0.0072.5ppm4M61W7D27
1710-1755 MHz0.12712.5ppm1M16G7D27
1710-1755 MHz0.1252.5ppm4M60G7D27
1710-1755 MHz0.11072.5ppm4M59W7D27
1850-1915 MHz0.14862.5ppm1M15G7D24E
1850-1915 MHz0.14592.5ppm4M61G7D24E
1850-1915 MHz0.12622.5ppm4M62W7D24E
1850-1910 MHz0.15812.5ppm1M14G7D24E
1850-1910 MHz0.14392.5ppm4M60G7D24E
1850-1910 MHz0.13462.5ppm4M61W7D24E
1850.2-1909.8 MHz0.38462.5ppm248KGXW24E
2500-2570 MHz0.07552.5ppm4M61W7D27
2500-2570 MHz0.08382.5ppm4M63G7D27

Grants

TCB Grant - Application UikU8L7TwnBbINNThXDKjw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 03/09/2021

Application Dated: 03/09/2021
Universal Physicians, LLC
7747 Supreme Ave NW
N. Canton, OH 44720
 
Attention: Shelly Hufford , Vice President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AJG4-FH-V1-4G
Name of Grantee:  Universal Physicians, LLC
Equipment Class: PCS Licensed Transmitter worn on body
Notes: FH Emergency Device - V1-4G
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.526 2.5  PM 253KGXW
24E 1850.2  -  1909.8 0.3846 2.5  PM 248KGXW
24E 1850.0  -  1910.0 0.1581 2.5  PM 1M14G7D
24E 1850.0  -  1910.0 0.1439 2.5  PM 4M60G7D
24E 1850.0  -  1910.0 0.1346 2.5  PM 4M61W7D
27 1710.0  -  1755.0 0.1271 2.5  PM 1M16G7D
27 1710.0  -  1755.0 0.125 2.5  PM 4M60G7D
27 1710.0  -  1755.0 0.1107 2.5  PM 4M59W7D
27 2500.0  -  2570.0 0.0838 2.5  PM 4M63G7D
27 2500.0  -  2570.0 0.0755 2.5  PM 4M61W7D
27 699.0  -  716.0 0.0114 2.5  PM 4M60G7D
27 699.0  -  716.0 0.0091 2.5  PM 4M61W7D
27 704.0  -  716.0 0.0081 2.5  PM 4M63G7D
27 704.0  -  716.0 0.007 2.5  PM 4M61W7D
24E 1850.0  -  1915.0 0.1486 2.5  PM 1M15G7D
24E 1850.0  -  1915.0 0.1459 2.5  PM 4M61G7D
24E 1850.0  -  1915.0 0.1262 2.5  PM 4M62W7D

Output power listed is ERP below 1GHz and EIRP above 1GHz.

This device supports LTE bandwidths of 1.4/3/5 MHz at LTE Band 2/4/12/25 and bandwidths of 5MHz at LTE Band 7/17.

This device contains functions that are not operational in U.S. and its territories. Filings under this FCC ID are approved only for U.S. operations.

For body worn operation, the FH Emergency Device - V1-4G has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the device a minimum of 0 mm from the body.Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance.

The highest reported SAR values for body-worn accessory use conditions is 1.44 W/kg.


EAS Grant - Application UikU8L7TwnBbINNThXDKjw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Universal Physicians, LLC
7747 Supreme Ave NW
N. Canton, OH 44720
United States
  Date of Grant: 03/09/2021

Application Dated: 03/09/2021
 
Attention: Shelly Hufford , Vice President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AJG4-FH-V1-4G
Name of Grantee:  Universal Physicians, LLC
Equipment Class: PCS Licensed Transmitter worn on body
Notes: FH Emergency Device - V1-4G
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.526 2.5  PM 253KGXW
24E 1850.2  -  1909.8 0.3846 2.5  PM 248KGXW
24E 1850.0  -  1910.0 0.1581 2.5  PM 1M14G7D
24E 1850.0  -  1910.0 0.1439 2.5  PM 4M60G7D
24E 1850.0  -  1910.0 0.1346 2.5  PM 4M61W7D
27 1710.0  -  1755.0 0.1271 2.5  PM 1M16G7D
27 1710.0  -  1755.0 0.125 2.5  PM 4M60G7D
27 1710.0  -  1755.0 0.1107 2.5  PM 4M59W7D
27 2500.0  -  2570.0 0.0838 2.5  PM 4M63G7D
27 2500.0  -  2570.0 0.0755 2.5  PM 4M61W7D
27 699.0  -  716.0 0.0114 2.5  PM 4M60G7D
27 699.0  -  716.0 0.0091 2.5  PM 4M61W7D
27 704.0  -  716.0 0.0081 2.5  PM 4M63G7D
27 704.0  -  716.0 0.007 2.5  PM 4M61W7D
24E 1850.0  -  1915.0 0.1486 2.5  PM 1M15G7D
24E 1850.0  -  1915.0 0.1459 2.5  PM 4M61G7D
24E 1850.0  -  1915.0 0.1262 2.5  PM 4M62W7D

Output power listed is ERP below 1GHz and EIRP above 1GHz.

This device supports LTE bandwidths of 1.4/3/5 MHz at LTE Band 2/4/12/25 and bandwidths of 5MHz at LTE Band 7/17.

This device contains functions that are not operational in U.S. and its territories. Filings under this FCC ID are approved only for U.S. operations.

For body worn operation, the FH Emergency Device - V1-4G has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the device a minimum of 0 mm from the body.Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance.

The highest reported SAR values for body-worn accessory use conditions is 1.44 W/kg.



Mail To: