TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy

HMD global Oy 3G mobile phone

Page 1 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 2 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 3 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 4 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 5 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 6 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 7 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 8 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 9 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 10 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 11 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 12 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 13 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 14 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 15 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 16 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 17 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 18 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 19 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 20 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 21 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 22 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 23 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 24 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 25 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 26 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 27 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 28 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 29 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 30 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 31 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 32 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 33 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 34 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 35 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 36 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 37 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 38 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 39 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 40 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 41 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 42 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Page 43 of TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab
Date: 2017.6.19
System Check_Head_835MHz
DUT: D835V2-SN:4d091
Communication System: UID 0, CW (0); Frequency: 835 MHz;Duty Cycle: 1:1
Medium: HSL_850 Medium parameters used: f = 835 MHz; σ = 0.914 S/m; εr = 41.643; ρ = 1000 kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.7 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3801; ConvF(8.8, 8.8, 8.8); Calibrated: 2016.6.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1279; Calibrated: 2017.5.2
- Phantom: SAM3; Type: SAM; Serial: TP-1839
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 2.94 W/kg
Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 51.83 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 3.43 W/kg
SAR(1 g) = 2.35 W/kg; SAR(10 g) = 1.57 W/kg
Maximum value of SAR (measured) = 2.95 W/kg
0 dB = 2.95 W/kg = 4.70 dBW/kg
Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab
Date: 2017.6.19
System Check_Head_1900MHz
DUT: D1900V2-SN:5d118
Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1
Medium: HSL_1900 Medium parameters used: f = 1900 MHz; σ = 1.44 S/m; εr = 40.908; ρ = 1000
kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.7 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3801; ConvF(7.39, 7.39, 7.39); Calibrated: 2016.6.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1279; Calibrated: 2017.5.2
- Phantom: SAM1; Type: SAM; Serial: TP-1842
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 14.5 W/kg
Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 2.709 V/m; Power Drift = 0.09 dB
Peak SAR (extrapolated) = 16.9 W/kg
SAR(1 g) = 9.78 W/kg; SAR(10 g) = 5.23 W/kg
Maximum value of SAR (measured) = 13.7 W/kg
0 dB = 13.7 W/kg = 11.37 dBW/kg
Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab
Date: 2017.6.21
System Check_Body_835MHz
DUT: D835V2-SN:4d091
Communication System: UID 0, CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: MSL_850 Medium parameters used: f = 835 MHz; σ = 0.974 S/m; εr = 54.938; ρ = 1000
kg/m3
Ambient Temperature:23.6 ℃; Liquid Temperature:22.6 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3801; ConvF(8.74, 8.74, 8.74); Calibrated: 2016.6.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1279; Calibrated: 2017.5.2
- Phantom: SAM3; Type: SAM; Serial: TP-1839
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 3.33 W/kg
Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 53.49 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 2.03 W/kg
SAR(1 g) = 2.65 W/kg; SAR(10 g) = 1.75 W/kg
Maximum value of SAR (measured) = 3.34 W/kg
0 dB = 3.33 W/kg = 5.22 dBW/kg
Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab
Date: 2017.6.16
System Check_Body_1900MHz
DUT: D1900V2-SN:5d118
Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1
Medium: MSL_1900 Medium parameters used: f = 1900 MHz; σ = 1.552 S/m; εr = 52.677; ρ = 1000
kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.7 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3801; ConvF(7.14, 7.14, 7.14); Calibrated: 2016.6.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1279; Calibrated: 2017.5.2
- Phantom: SAM3; Type: SAM; Serial: TP-1839
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 14.8 W/kg
Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 86.53 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 18.5 W/kg
SAR(1 g) = 10.5 W/kg; SAR(10 g) = 5.51 W/kg
Maximum value of SAR (measured) = 14.9 W/kg
0 dB = 14.9 W/kg = 11.73 dBW/kg
FCC SAR Test Report
Appendix B.
Report No. : FA752603
Plots of High SAR Measurement
The plots are shown as follows.
Sporton International (KunShan) INC.
TEL : 86-0512-5790-0158 / FAX : 86-0512-5790-0958
FCC ID : 2AJOTTA-1036
Page B1 of B1
Issued Date : Jul. 12, 2017
Form version. : 160427
Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab
Date: 2017.6.19
01_GSM850_GSM 1 Tx slot_Right Cheek_0mm_Ch251
Communication System: UID 0, General GSM (0); Frequency: 848.8 MHz;Duty Cycle: 1:8.3
Medium: HSL_850 Medium parameters used: f = 848.8 MHz; σ = 0.927 S/m; εr = 41.471; ρ =
1000 kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.7 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3801; ConvF(8.8, 8.8, 8.8); Calibrated: 2016.6.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1279; Calibrated: 2017.5.2
- Phantom: SAM3; Type: SAM; Serial: TP-1839
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
Ch251/Area Scan (51x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.575 W/kg
Ch251/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 11.02 V/m; Power Drift = -0.10 dB
Peak SAR (extrapolated) = 0.631 W/kg
SAR(1 g) = 0.472 W/kg; SAR(10 g) = 0.341 W/kg
Maximum value of SAR (measured) = 0.548 W/kg
0 dB = 0.548 W/kg = -2.61 dBW/kg
Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab
Date: 2017.6.19
02_GSM1900_GSM 1 Tx slot_Right Cheek_0mm_Ch512
Communication System: UID 0, General GSM (0); Frequency: 1850.2 MHz;Duty Cycle: 1:8.3
Medium: HSL_1900 Medium parameters used: f = 1850.2 MHz; σ = 1.39 S/m; εr = 41.109; ρ = 1000
kg/m3
Ambient Temperature:23.0 ℃; Liquid Temperature:22.0 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3801; ConvF(7.39, 7.39, 7.39); Calibrated: 2016.6.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1279; Calibrated: 2017.5.2
- Phantom: SAM1; Type: SAM; Serial: TP-1842
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
Ch512/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.563 W/kg
Ch512/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 10.89 V/m; Power Drift = -0.04 dB
Peak SAR (extrapolated) = 0.617 W/kg
SAR(1 g) = 0.429 W/kg; SAR(10 g) = 0.271 W/kg
Maximum value of SAR (measured) = 0.535 W/kg
0 dB = 0.535 W/kg = -2.72 dBW/kg
Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab
Date: 2017.6.19
03_WCDMA Band V_RMC 12.2Kbps_Right Cheek_0mm_Ch4132
Communication System: UID 0, UMTS (0); Frequency: 826.4 MHz;Duty Cycle: 1:1
Medium: HSL_850 Medium parameters used: f = 826.4 MHz; σ = 0.906 S/m; εr = 41.756; ρ = 1000
kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.7 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3801; ConvF(8.8, 8.8, 8.8); Calibrated: 2016.6.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1279; Calibrated: 2017.5.2
- Phantom: SAM3; Type: SAM; Serial: TP-1839
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
Ch4132/Area Scan (51x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.625 W/kg
Ch4132/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 12.04 V/m; Power Drift = -0.10 dB
Peak SAR (extrapolated) = 0.665 W/kg
SAR(1 g) = 0.502 W/kg; SAR(10 g) = 0.368 W/kg
Maximum value of SAR (measured) = 0.582 W/kg
0 dB = 0.582 W/kg = -2.35 dBW/kg
Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab
Date: 2017.6.19
04_WCDMA Band II_RMC 12.2Kbps_Right Cheek_0mm_Ch9400
Communication System: UID 0, UMTS (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: HSL_1900 Medium parameters used: f = 1880 MHz; σ = 1.419 S/m; εr = 40.98; ρ = 1000
kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.7 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3801; ConvF(7.39, 7.39, 7.39); Calibrated: 2016.6.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1279; Calibrated: 2017.5.2
- Phantom: SAM1; Type: SAM; Serial: TP-1842
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
Ch9400/Area Scan (51x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.804 W/kg
Ch9400/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 13.30 V/m; Power Drift = -0.04 dB
Peak SAR (extrapolated) = 0.899 W/kg
SAR(1 g) = 0.619 W/kg; SAR(10 g) = 0.391 W/kg
Maximum value of SAR (measured) = 0.771 W/kg
0 dB = 0.771 W/kg = -1.13 dBW/kg
Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab
Date: 2017.6.21
05_GSM850_GPRS 2 Tx slots_Back_15mm_Ch251
Communication System: UID 0, GPRS/EDGE (2 Tx slots) (0); Frequency: 848.8 MHz;Duty Cycle:1:4.15
Medium: MSL_850 Medium parameters used: f = 848.8 MHz; σ = 0.989 S/m; εr = 54.79; ρ = 1000 kg/m3
Ambient Temperature:23.6 ℃; Liquid Temperature:22.6 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3801; ConvF(8.74, 8.74, 8.74); Calibrated: 2016.6.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1279; Calibrated: 2017.5.2
- Phantom: SAM3; Type: SAM; Serial: TP-1839
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
Ch251/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.744 W/kg
Ch251/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 25.02 V/m; Power Drift = -0.13 dB
Peak SAR (extrapolated) = 0.742 W/kg
SAR(1 g) = 0.625 W/kg; SAR(10 g) = 0.481 W/kg
Maximum value of SAR (measured) = 0.700 W/kg
0 dB = 0.700 W/kg = -1.55 dBW/kg
Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab
Date: 2017.6.16
06_GSM1900_GPRS 2 Tx slots_Back_15mm_Ch810
Communication System: UID 0, GPRS/EDGE (2 Tx slots) (0); Frequency: 1909.8 MHz;Duty Cycle:1:4.15
Medium: MSL_1900 Medium parameters used: f = 1909.8 MHz; σ = 1.564 S/m; εr = 52.638; ρ = 1000kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.7 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3801; ConvF(7.14, 7.14, 7.14); Calibrated: 2016.6.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1279; Calibrated: 2017.5.2
- Phantom: SAM3; Type: SAM; Serial: TP-1839
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
Ch810/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.635 W/kg
Ch810/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 11.36 V/m; Power Drift = -0.08 dB
Peak SAR (extrapolated) = 0.706 W/kg
SAR(1 g) = 0.475 W/kg; SAR(10 g) = 0.307 W/kg
Maximum value of SAR (measured) = 0.601 W/kg
0 dB = 0.601 W/kg = -2.21 dBW/kg
Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab
Date: 2017.6.21
07_WCDMA Band V_RMC 12.2Kbps_Back_15mm_Ch4132
Communication System: UID 0, UMTS (0); Frequency: 826.4 MHz;Duty Cycle: 1:1
Medium: MSL_850 Medium parameters used: f = 826.4 MHz; σ = 0.966 S/m; εr = 55.026; ρ = 1000
kg/m3
Ambient Temperature:23.6 ℃; Liquid Temperature:22.6 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3801; ConvF(8.74, 8.74, 8.74); Calibrated: 2016.6.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1279; Calibrated: 2017.5.2
- Phantom: SAM3; Type: SAM; Serial: TP-1839
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
Ch4132/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.683 W/kg
Ch4132/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 23.93 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 0.699 W/kg
SAR(1 g) = 0.583 W/kg; SAR(10 g) = 0.450 W/kg
Maximum value of SAR (measured) = 0.657 W/kg
0 dB = 0.657 W/kg = -1.82 dBW/kg
Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab
Date: 2017.6.16
08_WCDMA Band II_RMC 12.2Kbps_Back_15mm_Ch9400
Communication System: UID 0, UMTS (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: MSL_1900 Medium parameters used: f = 1880 MHz; σ = 1.529 S/m; εr = 52.752; ρ = 1000
kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.7 ℃
DASY5 Configuration:
- Probe: EX3DV4 - SN3801; ConvF(7.14, 7.14, 7.14); Calibrated: 2016.6.29;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1279; Calibrated: 2017.5.2
- Phantom: SAM3; Type: SAM; Serial: TP-1839
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
Ch9400/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.794 W/kg
Ch9400/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 14.43 V/m; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 0.898 W/kg
SAR(1 g) = 0.599 W/kg; SAR(10 g) = 0.385 W/kg
Maximum value of SAR (measured) = 0.764 W/kg
0 dB = 0.764 W/kg = -1.17 dBW/kg
FCC SAR Test Report
Appendix C.
Report No. : FA752603
DASY Calibration Certificate
The DASY calibration certificates are shown as follows.
Sporton International (KunShan) INC.
TEL : 86-0512-5790-0158 / FAX : 86-0512-5790-0958
FCC ID : 2AJOTTA-1036
Page C1 of C1
Issued Date : Jul. 12, 2017
Form version. : 160427

Download: TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Mirror Download [FCC.gov]TA-1036 3G mobile phone RF Exposure Info SAR report part 2 HMD global Oy
Document ID3477748
Application IDZwFQuiCPe63EqZnEEtGwbg==
Document DescriptionSAR report part 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize402.1kB (5026191 bits)
Date Submitted2017-07-23 00:00:00
Date Available2017-07-25 00:00:00
Creation Date2017-07-20 19:29:15
Producing SoftwareFoxit PhantomPDF - Foxit Software Inc.
Document Lastmod2017-07-20 19:30:31
Document TitleSAR report part 2
Document Author: MelodySong

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Author                          : MelodySong
Create Date                     : 2017:07:20 19:29:15
Modify Date                     : 2017:07:20 19:30:31+08:00
Producer                        : Foxit PhantomPDF - Foxit Software Inc.
Has XFA                         : No
Page Count                      : 43