FCC ID 2AJSTJHR-AC836M

Wireless Router

by YICHEN (SHENZHEN) TECHNOLOGY CO., LTD

Grantee Code: 2AJST   Product Code: JHRAC836M
Latest application date: 2016-10-19

Device Images

FCC ID Device Details

FCC ID2AJSTJHR-AC836M
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AJST
Product CodeJHRAC836M
Applicant BusinessYICHEN (SHENZHEN) TECHNOLOGY CO., LTD 🇨🇳
Related Domains jcg.com.cn
Equipment ClassWireless Router
Test FirmKeyway Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2016-10-19
5180-5240 MHzOriginal Equipment2016-10-19

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2016-10-19PDF 5.4 MB
Internal PhotosInternal Photos2016-10-19PDF 541.7 KB
External PhotosExternal Photos2016-10-19PDF 698.1 KB
Label & Label LocationID Label/Location Info2016-10-19PDF 124.3 KB
RF Test Set-Up PhotosTest Setup Photos2016-10-19PDF 348.7 KB
RF Test ReportTest Report2016-10-19PDF 3.2 MB
RF Test Report-1Test Report2016-10-19PDF 5.3 MB
RF Test Report-2Test Report2016-10-19PDF 3.1 MB
DoC LetterAttestation Statements2016-10-19PDF 34.3 KB
Authorization LetterCover Letter(s)2016-10-19PDF 79.7 KB
DTS 12-13 ch Declaration LetterCover Letter(s)2016-10-19PDF 101.2 KB
Family Model LetterCover Letter(s)2016-10-19PDF 62.8 KB
LTC LetterCover Letter(s)2016-10-19PDF 110.7 KB
MPE ReportRF Exposure Info2016-10-19PDF 78.5 KB
Block Diagram Metadata onlyBlock DiagramPDF 89.5 KB
Schematics Metadata onlySchematicsPDF 378.8 KB
Schematics Metadata onlyOperational DescriptionPDF 378.8 KB
Software Security Requirement Metadata onlySchematicsPDF 128.6 KB
Operational Description Metadata onlyOperational DescriptionPDF 32 KB

Application Information

Application IDmWhNXA58TW3wgUA6mhpEsA==
Final Action Date2016-10-19
Application PurposeOriginal Equipment
Applicant FRN0025882648
ModelJHR-AC836M
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWireless Router
Responsible PartyHe Li, coldmoon@jcg.com.cn , 86-755-84550187
Test FirmJade Yang, Keyway Testing Technology Co., Ltd., jade.yang@keywaytest.com , 86-769-87182258
TCB Emailtcb@siemic.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is maximum conducted output power. Device is 2X2 MIMO. Device contains 20 / 40 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.

Applications

Application IDDatePurpose
mWhNXA58TW3wgUA6mhpEsA==2016-10-19Original Equipment
PcheB36Lk8rCKNmCSJQc5w==2016-10-19Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.037000015CCC, MO
5180-5240 MHz0.03315E38, CC, MO
5745-5825 MHz0.03515E38, CC, MO

Grants

TCB Grant - Application PcheB36Lk8rCKNmCSJQc5w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 10/19/2016

Application Dated: 10/19/2016
YICHEN (SHENZHEN) TECHNOLOGY CO., LTD
23/F, Block C1, Nanshan I Park, No. 1001,
Xueyuan Road, Taoyuan Street, Nanshan District,
Shenzhen,
China
 
Attention: He Li

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AJSTJHR-AC836M
Name of Grantee:  YICHEN (SHENZHEN) TECHNOLOGY CO., LTD
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Wireless Router
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.033  
38 CC MO 15E 5745.0  -  5825.0 0.035  

Product is restricted for indoor use only in the 5.15-5.25 GHz band. Power listed is maximum conducted output power. Device contains 20 / 40 / 80 MHz signal bandwidth. Device is 2X2 MIMO. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application PcheB36Lk8rCKNmCSJQc5w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

YICHEN (SHENZHEN) TECHNOLOGY CO., LTD
23/F, Block C1, Nanshan I Park, No. 1001, Xueyuan Road, Taoyuan Street, Nanshan District,
Shenzhen,
China
  Date of Grant: 10/19/2016

Application Dated: 10/19/2016
 
Attention: He Li

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AJSTJHR-AC836M
Name of Grantee:  YICHEN (SHENZHEN) TECHNOLOGY CO., LTD
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Wireless Router
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.033  
38 CC MO 15E 5745.0  -  5825.0 0.035  

Product is restricted for indoor use only in the 5.15-5.25 GHz band. Power listed is maximum conducted output power. Device contains 20 / 40 / 80 MHz signal bandwidth. Device is 2X2 MIMO. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application mWhNXA58TW3wgUA6mhpEsA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 10/19/2016

Application Dated: 10/19/2016
YICHEN (SHENZHEN) TECHNOLOGY CO., LTD
23/F, Block C1, Nanshan I Park, No. 1001,
Xueyuan Road, Taoyuan Street, Nanshan District,
Shenzhen,
China
 
Attention: He Li

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AJSTJHR-AC836M
Name of Grantee:  YICHEN (SHENZHEN) TECHNOLOGY CO., LTD
Equipment Class: Digital Transmission System
Notes: Wireless Router
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.037  

Power listed is maximum conducted output power. Device is 2X2 MIMO. Device contains 20 / 40 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application mWhNXA58TW3wgUA6mhpEsA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

YICHEN (SHENZHEN) TECHNOLOGY CO., LTD
23/F, Block C1, Nanshan I Park, No. 1001, Xueyuan Road, Taoyuan Street, Nanshan District,
Shenzhen,
China
  Date of Grant: 10/19/2016

Application Dated: 10/19/2016
 
Attention: He Li

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AJSTJHR-AC836M
Name of Grantee:  YICHEN (SHENZHEN) TECHNOLOGY CO., LTD
Equipment Class: Digital Transmission System
Notes: Wireless Router
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.037  

Power listed is maximum conducted output power. Device is 2X2 MIMO. Device contains 20 / 40 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: