FCC ID 2AJXY-EM200

Energy Manager for Glass

by Kinestral Technologies

Grantee Code: 2AJXY   Product Code: EM200
Latest application date: 2019-08-06

FCC ID Device Details

FCC ID2AJXY-EM200
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AJXY
Product CodeEM200
Applicant BusinessKinestral Technologies 🇺🇸
Related Domains kinestral.com
Equipment ClassEnergy Manager for Glass
Test FirmVPI Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2405-2475 MHzOriginal Equipment2019-08-06

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2019-08-06PDF 902.3 KB
Internal PhotosInternal Photos2019-08-06PDF 429.1 KB
External PhotosExternal Photos2019-08-06PDF 409 KB
Label LocationID Label/Location Info2019-08-06PDF 19.4 KB
Label SampleID Label/Location Info2019-08-06PDF 864.5 KB
Test Setup PhotosTest Setup Photos2019-08-06PDF 540.1 KB
Test ReportTest Report2019-08-06PDF 1.7 MB
Agent LetterCover Letter(s)2019-08-06PDF 125.4 KB
Confidentiality Request LetterCover Letter(s)2019-08-06PDF 127 KB
MPE ReportRF Exposure Info2019-08-06PDF 121.4 KB
Parts ListParts List/Tune Up Info2019-08-06PDF 157 KB
Block Diagram Metadata onlyBlock DiagramPDF 507.2 KB
Schematics Metadata onlySchematicsPDF 2.9 MB
Operational Description Metadata onlyOperational DescriptionPDF 93.7 KB

Application Information

Application ID5haA00cYuKDRj1Fp1RFRXA==
Final Action Date2019-08-06
Application PurposeOriginal Equipment
Applicant FRN0025929134
ModelEM200
Frequency Range2405-2475 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionEnergy Manager for Glass
Responsible PartyPaul E Nagel, Senior VP Product Development, pnagel@kinestral.com , 8014555544
Test FirmJason Stewart, VPI Laboratories, Inc., jasons@vpimfg.com , 801-495-2310
TCB Emailtei@timcoengr.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. The antenna installation and operating configurations of this transmitter, including any applicable antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter.

Applications

Application IDDatePurpose
5haA00cYuKDRj1Fp1RFRXA==2019-08-06Original Equipment

Equipment Authorization

FrequencyOutputRules
2405-2475 MHz0.020100015C

Grants

TCB Grant - Application 5haA00cYuKDRj1Fp1RFRXA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 08/06/2019

Application Dated: 08/06/2019
Kinestral Technologies
3955 Trust Way
P.O. Box 94080,
Hayward, CA 94545
 
Attention: Paul Nagel , Senior VP Product Development

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AJXY-EM200
Name of Grantee:  Kinestral Technologies
Equipment Class: Digital Transmission System
Notes: Energy Manager for Glass
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.0201  

Power listed is conducted. The antenna installation and operating configurations of this transmitter, including any applicable antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter.

EAS Grant - Application 5haA00cYuKDRj1Fp1RFRXA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Kinestral Technologies
3955 Trust Way P.O. Box 94080,
Hayward, CA 94545
United States
  Date of Grant: 08/06/2019

Application Dated: 08/06/2019
 
Attention: Paul Nagel , Senior VP Product Development

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AJXY-EM200
Name of Grantee:  Kinestral Technologies
Equipment Class: Digital Transmission System
Notes: Energy Manager for Glass
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.0201  

Power listed is conducted. The antenna installation and operating configurations of this transmitter, including any applicable antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter.



Mail To: