FCC ID 2AK5KU85E21006

upper arm electronic blood pressure monitor

by Shenzhen Urion Technology Co.,Ltd.

Grantee Code: 2AK5K   Product Code: U85E21006
Latest application date: 2022-09-20

FCC ID Device Details

FCC ID2AK5KU85E21006
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AK5K
Product CodeU85E21006
Applicant BusinessShenzhen Urion Technology Co.,Ltd. 🇨🇳
Related Domains urionsz.com
Equipment Classupper arm electronic blood pressure monitor
Test FirmShenzhen Huatongwei International Inspection Co.,

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
704-711 MHzOriginal Equipment2022-09-20

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2022-09-20PDF 905.1 KB
Internal photosInternal Photos2022-09-20PDF 570.2 KB
External photosExternal Photos2022-09-20PDF 533.7 KB
LabelID Label/Location Info2022-09-20PDF 301.5 KB
Test setupTest Setup Photos2022-09-20PDF 147.1 KB
Test setupTest Setup Photos2022-09-20PDF 197.1 KB
Test reportTest Report2022-09-20PDF 832.2 KB
Test report part 1Test Report2022-09-20PDF 3.8 MB
Test report part 10Test Report2022-09-20PDF 5.3 MB
Test report part 11Test Report2022-09-20PDF 5.3 MB
Test report part 12Test Report2022-09-20PDF 5.4 MB
Test report part 13Test Report2022-09-20PDF 5.4 MB
Test report part 14Test Report2022-09-20PDF 5.4 MB
Test report part 15Test Report2022-09-20PDF 5.4 MB
Test report part 16Test Report2022-09-20PDF 5.5 MB
Test report part 17Test Report2022-09-20PDF 5.5 MB
Test report part 18Test Report2022-09-20PDF 3.7 MB
Test report part 2Test Report2022-09-20PDF 5.3 MB
Test report part 3Test Report2022-09-20PDF 5.4 MB
Test report part 4Test Report2022-09-20PDF 5.4 MB
Test report part 5Test Report2022-09-20PDF 5.4 MB
Test report part 6Test Report2022-09-20PDF 5.4 MB
Test report part 7Test Report2022-09-20PDF 5.5 MB
Test report part 8Test Report2022-09-20PDF 5.2 MB
Test report part 9Test Report2022-09-20PDF 5.5 MB
Cover LetterCover Letter(s)2022-09-20PDF 2.5 MB
Cover letterCover Letter(s)2022-09-20PDF 605.1 KB
RF ExposureRF Exposure Info2022-09-20PDF 109.2 KB
Block Diagram Metadata onlyBlock DiagramPDF 386.9 KB
Schematics Metadata onlySchematicsPDF 77 KB
Operational Description Metadata onlyOperational DescriptionPDF 838.9 KB
Parts list Metadata onlyParts List/Tune Up InfoPDF 128 KB
Tune up Metadata onlyParts List/Tune Up InfoPDF 11.4 KB

Application Information

Application IDH+PTypSeD1Xsc/eQDstcCQ==
Final Action Date2022-09-20
Application PurposeOriginal Equipment
Applicant FRN0026250597
ModelU85E21006
Frequency Range704-711 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device Descriptionupper arm electronic blood pressure monitor
Responsible PartyRain Zhu, Director, rainzhu@urionsz.com , 0755-29231308
Test FirmJason Liu, Shenzhen Huatongwei International Inspection Co.,, quality@szhtw.com.cn , +86-755-26748078
TCB Emailvina.kerai@nemko.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power is EIRP and ERP for above and below 1 GHz, respectively. This transmitter must be installed and operated so as to provide a separation distance as evaluated in this filing from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. This device supports LTE Cat M1 FDD LTE Bands 2, 4, 5, 12, and 13.

Applications

Application IDDatePurpose
H+PTypSeD1Xsc/eQDstcCQ==2022-09-20Original Equipment
1XCHCEJ08s/CpGG7EFPLRg==2022-09-20Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
704-711 MHz0.19450.01ppm1M17G7D27
704-711 MHz0.17820.01ppm1M18W7D27
782 MHz0.24890.01ppm1M17W7D27
782 MHz0.2350.01ppm1M17G7D27
829-844 MHz0.21380.01ppm1M16G7D22H
829-844 MHz0.19540.01ppm1M16W7D22H
1720-1745 MHz0.3420.01ppm1M21G7D27
1720-1745 MHz0.35560.01ppm1M21W7D27
1860-1900 MHz0.30480.01ppm1M21W7D24E

Grants

TCB Grant - Application H+PTypSeD1Xsc/eQDstcCQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 09/20/2022

Application Dated: 09/20/2022
Shenzhen Urion Technology Co.,Ltd.
4F to 6F of Bld D Jiale Ind Zone
No.3,ChuangWei Road ,MaTian St, GuangMing New Dist
Shenzhen,
China
 
Attention: Rain Zhu , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AK5KU85E21006
Name of Grantee:  Shenzhen Urion Technology Co.,Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: upper arm electronic blood pressure monitor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1860.0  -  1900.0 0.2985 0.01  PM 1M20G7D
24E 1860.0  -  1900.0 0.3048 0.01  PM 1M21W7D
27 1720.0  -  1745.0 0.342 0.01  PM 1M21G7D
27 1720.0  -  1745.0 0.3556 0.01  PM 1M21W7D
22H 829.0  -  844.0 0.2138 0.01  PM 1M16G7D
22H 829.0  -  844.0 0.1954 0.01  PM 1M16W7D
27 704.0  -  711.0 0.1945 0.01  PM 1M17G7D
27 704.0  -  711.0 0.1782 0.01  PM 1M18W7D
27 782.0  -  782.0 0.235 0.01  PM 1M17G7D
27 782.0  -  782.0 0.2489 0.01  PM 1M17W7D

Output Power is EIRP and ERP for above and below 1 GHz, respectively. This transmitter must be installed and operated so as to provide a separation distance as evaluated in this filing from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. This device supports LTE Cat M1 FDD LTE Bands 2, 4, 5, 12, and 13.

EAS Grant - Application H+PTypSeD1Xsc/eQDstcCQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Urion Technology Co.,Ltd.
4F to 6F of Bld D Jiale Ind Zone No.3,ChuangWei Road ,MaTian St, GuangMing New Dist
Shenzhen,
China
  Date of Grant: 09/20/2022

Application Dated: 09/20/2022
 
Attention: Rain Zhu , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AK5KU85E21006
Name of Grantee:  Shenzhen Urion Technology Co.,Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: upper arm electronic blood pressure monitor
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1860.0  -  1900.0 0.2985 0.01  PM 1M20G7D
24E 1860.0  -  1900.0 0.3048 0.01  PM 1M21W7D
27 1720.0  -  1745.0 0.342 0.01  PM 1M21G7D
27 1720.0  -  1745.0 0.3556 0.01  PM 1M21W7D
22H 829.0  -  844.0 0.2138 0.01  PM 1M16G7D
22H 829.0  -  844.0 0.1954 0.01  PM 1M16W7D
27 704.0  -  711.0 0.1945 0.01  PM 1M17G7D
27 704.0  -  711.0 0.1782 0.01  PM 1M18W7D
27 782.0  -  782.0 0.235 0.01  PM 1M17G7D
27 782.0  -  782.0 0.2489 0.01  PM 1M17W7D

Output Power is EIRP and ERP for above and below 1 GHz, respectively. This transmitter must be installed and operated so as to provide a separation distance as evaluated in this filing from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. This device supports LTE Cat M1 FDD LTE Bands 2, 4, 5, 12, and 13.



TCB Grant - Application 1XCHCEJ08s/CpGG7EFPLRg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 09/20/2022

Application Dated: 09/20/2022
Shenzhen Urion Technology Co.,Ltd.
4F to 6F of Bld D Jiale Ind Zone
No.3,ChuangWei Road ,MaTian St, GuangMing New Dist
Shenzhen,
China
 
Attention: Rain Zhu , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AK5KU85E21006
Name of Grantee:  Shenzhen Urion Technology Co.,Ltd.
Equipment Class: Part 15 Class B Digital Device
Notes: upper arm electronic blood pressure monitor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15B  - 


EAS Grant - Application 1XCHCEJ08s/CpGG7EFPLRg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Urion Technology Co.,Ltd.
4F to 6F of Bld D Jiale Ind Zone No.3,ChuangWei Road ,MaTian St, GuangMing New Dist
Shenzhen,
China
  Date of Grant: 09/20/2022

Application Dated: 09/20/2022
 
Attention: Rain Zhu , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AK5KU85E21006
Name of Grantee:  Shenzhen Urion Technology Co.,Ltd.
Equipment Class: Part 15 Class B Digital Device
Notes: upper arm electronic blood pressure monitor
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15B  - 



Mail To: