FCC ID 2AK72REU0707

digital-analog convertor and power amplifier

by KATHREIN Solutions GmbH

Grantee Code: 2AK72   Product Code: REU0707
Latest application date: 2017-05-04

Device Images

FCC ID Device Details

FCC ID2AK72REU0707
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AK72
Product CodeREU0707
Applicant BusinessKATHREIN Solutions GmbH 🇩🇪
Related Domains kathrein.de sgs.com
Equipment Classdigital-analog convertor and power amplifier
Test FirmSGS-CSTC Standards Technical Services Co.,Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2620-2690 MHzOriginal Equipment2017-05-04

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2017-05-04PDF 4.1 MB
Internal PhotosInternal Photos2017-05-04PDF 1.1 MB
External PhotosExternal Photos2017-05-04PDF 378.8 KB
LabelID Label/Location Info2017-05-04PDF 235.8 KB
Label LocationID Label/Location Info2017-05-04PDF 313.1 KB
Setpu PhotosTest Setup Photos2017-05-04PDF 183.6 KB
Test ReportTest Report2017-05-04PDF 3.9 MB
Authorization LetterCover Letter(s)2017-05-04PDF 673.8 KB
Confidentiality LetterCover Letter(s)2017-05-04PDF 498.7 KB
Cover LetterCover Letter(s)2017-05-04PDF 591.4 KB
Block Diagram Metadata onlyBlock DiagramPDF 19.3 KB
Schematic Metadata onlySchematicsPDF 326.7 KB
Schematics Metadata onlySchematicsPDF 948.9 KB
Operation Description Metadata onlyOperational DescriptionPDF 2.5 MB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 330.2 KB

Application Information

Application IDnT6O/sFejQBiBofIBCmJZw==
Final Action Date2017-05-04
Application PurposeOriginal Equipment
Applicant FRN0026253872
ModelREU0707
Frequency Range2620-2690 MHz
Equipment ClassB2I - Part 20 Industrial Booster (CMRS)
Device Descriptiondigital-analog convertor and power amplifier
Responsible PartyVeronika Shivaldova, veronika.shivaldova@kathrein.de , +49 08031 184-8366
AgentJack Jack Jack, SGS-CSTC Standards Technical Services Co., Ltd, Jack.Zhang@sgs.com , 0755-25328506
Technical Contactkeny XU, SGS-CSTC Standards Technical Services Co., Ltd, keny.xu@sgs.com , 0755-2654 4119
Non-Technical ContactSade LUO, SGS-CSTC Standards Technical Services Co., Ltd, Sade.Luo@sgs.com , 0755-25328662
Test FirmJune Zhang, SGS-CSTC Standards Technical Services Co.,Ltd., June.Zhang@sgs.com , 8675525328598
TCB EmailUSCTS.TCB@SGS.COM
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output is conducted at the antenna terminal. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3).

Applications

Application IDDatePurpose
nT6O/sFejQBiBofIBCmJZw==2017-05-04Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
2620-2690 MHz23.66Amp4M48G7D27
2620-2690 MHz21.53Amp17M9G7D27
2620-2690 MHz22.96Amp4M17F9W27

Grants

TCB Grant - Application nT6O/sFejQBiBofIBCmJZw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 05/04/2017

Application Dated: 05/04/2017
KATHREIN Solutions GmbH
Lise-Meitner-Strasse 7, 85737 Ismaning
Ismaning,
Germany
 
Attention: Veronika Shivaldova

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AK72REU0707
Name of Grantee:  KATHREIN Solutions GmbH
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: digital-analog convertor and power amplifier
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 2620.0  -  2690.0 23.66  Amp 4M48G7D
27 2620.0  -  2690.0 21.53  Amp 17M9G7D
27 2620.0  -  2690.0 22.96  Amp 4M17F9W

Power output is conducted at the antenna terminal. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3).

EAS Grant - Application nT6O/sFejQBiBofIBCmJZw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

KATHREIN Solutions GmbH
Lise-Meitner-Strasse 7, 85737 Ismaning
Ismaning,
Germany
  Date of Grant: 05/04/2017

Application Dated: 05/04/2017
 
Attention: Veronika Shivaldova

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AK72REU0707
Name of Grantee:  KATHREIN Solutions GmbH
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: digital-analog convertor and power amplifier
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 2620.0  -  2690.0 23.66  Amp 4M48G7D
27 2620.0  -  2690.0 21.53  Amp 17M9G7D
27 2620.0  -  2690.0 22.96  Amp 4M17F9W

Power output is conducted at the antenna terminal. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3).



Mail To: