FCC ID Device Details

FCC ID2AK8Y-M0208
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AK8Y
Product CodeM0208
Applicant BusinessCatalia Health Inc. 🇺🇸
Related Domains cataliahealth.com
Equipment ClassMabu
Test FirmShenzhen Toby Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
699-716 MHzOriginal Equipment2020-07-21
2402-2480 MHzOriginal Equipment2020-07-21

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2021-01-18PDF 157.8 KB
Internal PhotosInternal Photos2021-01-18PDF 626.5 KB
External PhotosExternal Photos2021-01-18PDF 499 KB
Label and label locationID Label/Location Info2020-07-21PDF 399.6 KB
Label and locationID Label/Location Info2020-07-21PDF 399.6 KB
Test Setup PhotosTest Setup Photos2021-01-18PDF 336.1 KB
Test Setup Photos-SARTest Setup Photos2021-01-18PDF 1.4 MB
Test report-DTS-2G4WLANTest Report2020-07-21PDF 2.9 MB
Test report-DTS-BLETest Report2020-07-21PDF 822 KB
Test report-PCB_LTE Part1Test Report2020-07-21PDF 4.4 MB
Test report-PCB_LTE Part2Test Report2020-07-21PDF 4.1 MB
FCC Confidentiality request letterCover Letter(s)2020-07-21PDF 83.2 KB
FCC Declaration of Disable WLAN Channel 12 and 13Cover Letter(s)2020-07-21PDF 111.4 KB
FCC POACover Letter(s)2020-07-21PDF 31.2 KB
RF Exposure Info-SAR ReportRF Exposure Info2020-07-21PDF 3.1 MB
SAR Calibration CertificateRF Exposure Info2020-07-21PDF 1.5 MB
Block diagram Metadata onlyBlock DiagramPDF 305.9 KB
Shematic Metadata onlySchematicsPDF 1.5 MB
Declaration concerning Antenna Specification Metadata onlyOperational DescriptionPDF 56.2 KB
Operation Description Metadata onlyOperational DescriptionPDF 118.9 KB
Part lists Metadata onlyParts List/Tune Up InfoPDF 135.9 KB

Application Information

Application IDW8r+HYAC75+5gp/Begl+bw==
Final Action Date2020-07-21
Application PurposeOriginal Equipment
Applicant FRN0026288498
ModelM0208
Frequency Range699-716 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionMabu
Responsible PartyCory Kidd, Chief Executive Officer, coryk@cataliahealth.com , 415-660-9264
AgentIvan Ivan Ivan, Shenzhen Toby Technology Co., Ltd., toby858@tongbiao.com , (86)755-26509301
Test FirmRay Lai, Shenzhen Toby Technology Co., Ltd., toby857@tongbiao.com , ---
TCB Emailjoergkusig@eurofins.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date01/18/2021
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsOutput power listed is ERP below 1GHz and EIRP above 1GHz. This device supports LTE bandwidths of 1.4, 3, 5, 10, 15, 20 MHz at LTE Band 2 and 4 and of 1.4, 3, 5 and 10 MHz at LTE Band 12. For body worn operation, this Mabu has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the Mabu a minimum of 10 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported 10-g SAR for limb-Worn and simultaneous transmission use conditions are 2.90 W/kg, and 2.94 W/kg, respectively. The highest reported 1-g SAR for body-worn accessory and simultaneous transmission use conditions are 1.29 W/kg, and 1.34 W/kg, respectively.

Applications

Application IDDatePurpose
W8r+HYAC75+5gp/Begl+bw==2020-07-21Original Equipment
O2xtjaaS5yvGU9/tIfTbbw==2020-07-21Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
699-716 MHz0.16480.5552ppm8M93G7D27
699-716 MHz0.16070.5523ppm2M68W7D27
699-716 MHz0.15670.5523ppm4M51W7D27
1710-1755 MHz0.15280.6773ppm17M9G7D27
1710-1755 MHz0.15670.5363ppm2M68W7D27
1710-1755 MHz0.14890.5363ppm4M52W7D27
1850-1910 MHz0.17580.0835ppm2M69G7D24E
1850-1910 MHz0.15670.0835ppm17M8G7D24E
1850-1910 MHz0.15630.6331ppm4M46W7D24E
2402-2480 MHz0.004415C
2412-2462 MHz0.036215C

Grants

TCB Grant - Application W8r+HYAC75+5gp/Begl+bw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 07/21/2020

Application Dated: 07/21/2020
Catalia Health Inc.
118 2nd Street
2nd Floor
San Francisco, CA 94105
 
Attention: Cory Kidd , Chief Executive Officer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AK8Y-M0208
Name of Grantee:  Catalia Health Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Mabu
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.0  -  1910.0 0.1758 0.0835  PM 2M69G7D
24E 1850.0  -  1910.0 0.1567 0.0835  PM 17M8G7D
24E 1850.0  -  1910.0 0.1563 0.6331  PM 4M46W7D
27 1710.0  -  1755.0 0.1528 0.6773  PM 17M9G7D
27 1710.0  -  1755.0 0.1567 0.5363  PM 2M68W7D
27 1710.0  -  1755.0 0.1489 0.5363  PM 4M52W7D
27 699.0  -  716.0 0.1648 0.5552  PM 8M93G7D
27 699.0  -  716.0 0.1607 0.5523  PM 2M68W7D
27 699.0  -  716.0 0.1567 0.5523  PM 4M51W7D

Output power listed is ERP below 1GHz and EIRP above 1GHz. This device supports LTE bandwidths of 1.4, 3, 5, 10, 15, 20 MHz at LTE Band 2 and 4 and of 1.4, 3, 5 and 10 MHz at LTE Band 12.

For body worn operation, this Mabu has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the Mabu a minimum of 10 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance.

The highest reported 10-g SAR for limb-Worn and simultaneous transmission use conditions are 2.90 W/kg, and 2.94 W/kg, respectively. The highest reported 1-g SAR for body-worn accessory and simultaneous transmission use conditions are 1.29 W/kg, and 1.34 W/kg, respectively.


EAS Grant - Application W8r+HYAC75+5gp/Begl+bw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Catalia Health Inc.
118 2nd Street 2nd Floor
San Francisco, CA 94105
United States
  Date of Grant: 07/21/2020

Application Dated: 07/21/2020
 
Attention: Cory Kidd , Chief Executive Officer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AK8Y-M0208
Name of Grantee:  Catalia Health Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Mabu
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.0  -  1910.0 0.1758 0.0835  PM 2M69G7D
24E 1850.0  -  1910.0 0.1567 0.0835  PM 17M8G7D
24E 1850.0  -  1910.0 0.1563 0.6331  PM 4M46W7D
27 1710.0  -  1755.0 0.1528 0.6773  PM 17M9G7D
27 1710.0  -  1755.0 0.1567 0.5363  PM 2M68W7D
27 1710.0  -  1755.0 0.1489 0.5363  PM 4M52W7D
27 699.0  -  716.0 0.1648 0.5552  PM 8M93G7D
27 699.0  -  716.0 0.1607 0.5523  PM 2M68W7D
27 699.0  -  716.0 0.1567 0.5523  PM 4M51W7D

Output power listed is ERP below 1GHz and EIRP above 1GHz. This device supports LTE bandwidths of 1.4, 3, 5, 10, 15, 20 MHz at LTE Band 2 and 4 and of 1.4, 3, 5 and 10 MHz at LTE Band 12.

For body worn operation, this Mabu has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the Mabu a minimum of 10 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance.

The highest reported 10-g SAR for limb-Worn and simultaneous transmission use conditions are 2.90 W/kg, and 2.94 W/kg, respectively. The highest reported 1-g SAR for body-worn accessory and simultaneous transmission use conditions are 1.29 W/kg, and 1.34 W/kg, respectively.



TCB Grant - Application O2xtjaaS5yvGU9/tIfTbbw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 07/21/2020

Application Dated: 07/21/2020
Catalia Health Inc.
118 2nd Street
2nd Floor
San Francisco, CA 94105
 
Attention: Cory Kidd , Chief Executive Officer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AK8Y-M0208
Name of Grantee:  Catalia Health Inc.
Equipment Class: Digital Transmission System
Notes: Mabu
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0044  
15C 2412.0  -  2462.0 0.0362  

Output Power listed is peak conducted.

This device supports 802.11b, 802.11g and 802.11n with a 20 MHz bandwidth mode.

For body worn operation, this Mabu has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the Mabu a minimum of 10 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance.

The highest reported 10-g SAR for limb-Worn and simultaneous transmission use conditions are 0.40 W/kg, and 2.94 W/kg, respectively. The highest reported 1-g SAR for body-worn accessory and simultaneous transmission use conditions are 0.28 W/kg, and 1.34 W/kg, respectively.


EAS Grant - Application O2xtjaaS5yvGU9/tIfTbbw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Catalia Health Inc.
118 2nd Street 2nd Floor
San Francisco, CA 94105
United States
  Date of Grant: 07/21/2020

Application Dated: 07/21/2020
 
Attention: Cory Kidd , Chief Executive Officer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AK8Y-M0208
Name of Grantee:  Catalia Health Inc.
Equipment Class: Digital Transmission System
Notes: Mabu
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0044  
15C 2412.0  -  2462.0 0.0362  

Output Power listed is peak conducted.

This device supports 802.11b, 802.11g and 802.11n with a 20 MHz bandwidth mode.

For body worn operation, this Mabu has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the Mabu a minimum of 10 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance.

The highest reported 10-g SAR for limb-Worn and simultaneous transmission use conditions are 0.40 W/kg, and 2.94 W/kg, respectively. The highest reported 1-g SAR for body-worn accessory and simultaneous transmission use conditions are 0.28 W/kg, and 1.34 W/kg, respectively.



Mail To: