ONB18WI706 Wireless Charging Stand Test Report SZEM180600531301-Part18, RPT Zhejiang Fousine Science &Technology; Co.Ltd.

Zhejiang Fousine Science &Technology; Co.Ltd. Wireless Charging Stand

Alternate Views: PDF [Zoom] Download [PDF]

                                                               SGS-CSTC Standards Technical Services Co., Ltd.
                                                               Shenzhen Branch

No. 1 Workshop, M-10, Middle section, Science & Technology Park,
Shenzhen, Guangdong, China 518057
Telephone:            +86 (0) 755 2601 2053                                                                                       Report No.: SZEM180600531301
Fax:                  +86 (0) 755 2671 0594
                                                                                                                                  Page:        1 of 17
Email:                ee.shenzhen@sgs.com




                                                                    TEST REPORT
Application No.:                                            SZEM1806005313CR
Applicant:                                                  Zhejiang Fousine Science & Technology CO., Ltd.
Address of Applicant:                                       No. 198 Changyuan Rd.,Yuyao, Zhejiang Prvn., China 315400
Manufacturer:                                               Zhejiang Fousine Science & Technology CO., Ltd.
Address of Manufacturer:                                    No.198, Changyuan Road, Yuyao City, Zhejiang Province, China
Factory:                                                    Zhejiang Fousine Science & Technology CO., Ltd.
Address of Factory:                                         No.198, Changyuan Road, Yuyao City, Zhejiang Province, China
Equipment Under Test (EUT):
EUT Name:                                                   Wireless Charging Stand
Model No.:                                                  ONB18WI706
Trade mark:                                                 ONN
FCC ID:                                                     2AKP3-ONB18WI706
Standard(s) :                                               47 CFR Part 18
Date of Receipt:                                            2018-06-20
Date of Test:                                               2018-06-23 to 2018-06-24
Date of Issue:                                              2018-06-27
Test Result:                                                Pass*
* In the configuration tested, the EUT complied with the standards specified above.




                   Keny Xu
             EMC Laboratory Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International
Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International
Electrical Approvals in writing.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       2 of 17


                                                                                            Revision Record
                 Version                    Chapter                                           Date                                        Modifier                               Remark

                 01                                                                   2018-06-27                                                                                 Original




       Authorized for issue by:




                                                                     Leo Lai /Project Engineer




                                                                     Eric Fu /Reviewer




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       3 of 17


2          Test Summary
            Radio Spectrum Matter Part
                              Item                               Standard                                    Method                                     Requirement                               Result
                      Conducted
                                                           47 CFR Part 18                                 FCC MP-5                                        Part 18.307                               Pass
                      disturbance
               Radiated emission                           47 CFR Part 18                                 FCC MP-5                                        Part 18.305                               Pass




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                             SGS—CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                   Report No.: SZENM1etsoossts01
                                                   Page        Aof 17

3         Contents
                                                                               Page
1.        covenprce
2.        Test summany.
s         contents
a    eenenaL inFonmation                                                            s
 41—     bemuscrEUT                                                                 s
 42.     Descartonor Supzort Uins                                                   s
 43      Mexsureent Uicermiay                                                       s
 aa     TesLoownon                                                                  s
 45— TestFroum                                                                      s
 48.     Devamonrromstawowes                                                        s
 47     AmvommumesrronStaicaro Conmions                                             s
s Eoupment List.                                                                    3
6         mabio spectnum matren Test nesutts
     s1     Cornucrenosturemce,
       €.1.1 EUT. Operaton
       €.1.2 TestSotup Diagram
       618 Measuremont Procedire and Date
     s2 Raowreosmssion
       €21 EUT.Operaton
       €22.. TestSetupDiagram
       €23.— Measuremont Procedire and Date
7        pHotocnaphs
     71—    Coroucrenosturemce TesrSerte                                           16
     7e     Mrowreosmssion Tesr Serue                                              16
     7      EUT Coustruenor«. DetasuT Proros;                                      ar


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       5 of 17


4          General Information
4.1 Details of E.U.T.
           Power supply:                                    DC 5V from Adapter
           Cable:                                           USB cable: 100cm shielded
           Operation Frequency:                             112-205kHz
           Antenna Type:                                    Loop antenna
           Modulation type:                                 Load modulation
           Test voltage:                                    AC 120V/60Hz (Voltage of the AC/DC adapter)
           Remark:                                          This device has been tested the worst status of full load and mobile phone
                                                            at zero charge, intermediate charge, and full charge. The worst data was
                                                            show in the report and mobile phone at zero charge is the worst case if not
                                                            other specified.


4.2 Description of Support Units

           Description                                              Manufacturer                                            Model No.                                          Serial No.
             Mobile phone                                                Samsung                                                G950F                                                 N/A
                   Adapter                                                 Huawei                                     HW-059200CHQ                                                    N/A
              Dummy load                                               E-Charging                                                  N/A                                                N/A


4.3 Measurement Uncertainty

                No.                                                      Item                                                              Measurement Uncertainty
                  1                                          Radio Frequency                                                                             ± 7.25 x 10-8
                  2                                                 Duty cycle                                                                               ± 0.37%
                  3                                       Occupied Bandwidth                                                                                    ± 3%
                  4                                       RF conducted power                                                                                ± 0.75dB
                  5                                          RF power density                                                                               ± 2.84dB
                  6                             Conducted Spurious emissions                                                                                ± 0.75dB
                                                                                                                                                ± 4.5dB (below 1GHz)
                  7                                        RF Radiated power
                                                                                                                                                ± 4.8dB (above 1GHz)
                                                                                                                                                ± 4.5dB (Below 1GHz)
                  8                            Radiated Spurious emission test
                                                                                                                                               ± 4.8dB (Above 1GHz)
                  9                                          Temperature test                                                                                   ± 1°C
                 10                                              Humidity test                                                                                  ± 3%
                 11                                            Supply voltages                                                                                ± 1.5%
                 12                                                      Time                                                                                   ± 3%




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       6 of 17

4.4 Test Location
            All tests were performed at:
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
            No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
            518057.
            Tel: +86 755 2601 2053                                    Fax: +86 755 2671 0594
            No tests were sub-contracted.

4.5 Test Facility
            The test facility is recognized, certified, or accredited by the following organizations:
            • CNAS (No. CNAS L2929)
            CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
            Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
            Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
            Laboratories) for the competence in the field of testing.
            • A2LA (Certificate No. 3816.01)
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
            American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
            • VCCI
            The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
            Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
            Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
            been registered in accordance with the Regulations for Voluntary Control Measures with Registration
            No.: G-20026, R-14188, C-12383 and T-11153 respectively.
            • FCC –Designation Number: CN1178
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
            as an accredited testing laboratory.
            Designation Number: CN1178. Test Firm Registration Number: 406779.
            • Industry Canada (IC)
            Two 3m Semi-anechoic chambers and the 10m Semi-anechoic chamber of SGS-CSTC Standards
            Technical Services Co., Ltd. Shenzhen Branch EMC Lab have been registered by Certification and
            Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 4620C-1,
            4620C-2, 4620C-3.
4.6 Deviation from Standards
            None
4.7 Abnormalities from Standard Conditions
            None




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       7 of 17


5          Equipment List
Conducted disturbance
            Equipment                                   Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
        Shielding Room                           ChangZhou ZhongYu                                  GB-88                     SEM001-06                    2017-05-10                   2020-05-09
 Measurement Software                                          AUDIX                         e3 V5.4.1221d                            N/A                          N/A                         N/A
          Coaxial Cable                                          SGS                                   N/A                    SEM024-01                    2017-07-13                   2018-07-12
                   LISN                             Rohde & Schwarz                                ENV216                     SEM007-01                    2017-09-27                   2018-09-26
                   LISN                               ETS-LINDGREN                                  3816/2                    SEM007-02                    2018-04-02                   2019-04-01
      EMI Test Receiver                             Rohde & Schwarz                                   ESCI                    SEM004-02                    2018-04-02                   2019-04-01


Radiated emission
            Equipment                                   Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
    10m Semi-Anechoic
                                                              SAEMC                             FSAC1018                      SEM001-03                    2018-03-31                   2021-03-30
        Chamber
                                                                                             e3 V8.2014-6-
 Measurement Software                                          AUDIX                                                                  N/A                          N/A                         N/A
                                                                                                  27
          Coaxial Cable                                          SGS                                   N/A                    SEM029-01                    2017-07-13                   2018-07-12
      EMI Test Receiver
                                                    Rohde & Schwarz                                   ESCI                    SEM004-01                    2018-04-02                   2019-04-01
        (9kHz-3GHz)
    Trilog-Broadband
                                                         Schwarzbeck                            VULB9168                      SEM003-18                    2016-01-26                   2019-01-25
 Antenna(30MHz-1GHz)
                                                   Sonoma Instrument
           Pre-amplifier                                                                             310N                     SEM005-04                    2018-04-13                   2019-04-12
                                                         Co
    Active Loop Antenna                                 ETS-Lindgren                                  6502                    SEM003-08                    2017-08-22                   2020-08-21


General used equipment
             Equipment                                  Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
                                                         Shanghai
  Humidity/ Temperature
                                                       Meteorological                               ZJ1-2B                    SEM002-03                    2017-09-29                   2018-09-28
        Indicator
                                                      Industry Factory
                                                         Shanghai
  Humidity/ Temperature
                                                       Meteorological                               ZJ1-2B                    SEM002-04                    2017-09-29                   2018-09-28
        Indicator
                                                      Industry Factory
  Humidity/ Temperature
                                                                Mingle                                 N/A                    SEM002-08                    2017-09-29                   2018-09-28
        Indicator
                                                        Changchun
              Barometer                                Meteorological                                DYM3                     SEM002-01                    2018-04-08                   2019-04-07
                                                      Industry Factory




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       8 of 17



6          Radio Spectrum Matter Test Results
6.1 Conducted disturbance
           Test Requirement                                 Part 18.307
           Test Method:                                     FCC MP-5
           Limit:




6.1.1 E.U.T. Operation
      Operating Environment:
      Temperature:      26.2 °C       Humidity: 53.9 % RH                                                                               Atmospheric Pressure: 1010                                  mbar
      Test mode         a:Charge mode_Keep the EUT charging
6.1.2 Test Setup Diagram




6.1.3 Measurement Procedure and Data




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       9 of 17


Mode:a; Line:Live Line




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       10 of 17


Mode:a; Line:Neutral Line




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       11 of 17


6.2 Radiated emission
           Test Requirement      Part 18.305
           Test Method:          FCC MP-5
           Measurement Distance: 10m
           Limit:




          1Field
           strength may not exceed 10 µV/m at 1600 meters. Consumer equipment operating below 1000
MHz is not permitted the increase in field strength otherwise permitted here for power over 500 watts.
          2Reduced            to the greatest extent possible.
     3Field strength may not exceed 10 µV/m at 1600 meters. Consumer equipment is not permitted the

increase in field strength otherwise permitted here for over 500 watts.
4Induction cooking ranges manufactured prior to February 1, 1980, shall be subject to the field strength limits
for miscellaneous ISM equipment.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       12 of 17



6.2.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C         Humidity: 51 % RH                                                                                 Atmospheric Pressure: 1010                                  mbar
      Test mode         a:Charge mode_Keep the EUT charging
6.2.2 Test Setup Diagram




6.2.3 Measurement Procedure and Data




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       13 of 17


9kHz~150kHz




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       14 of 17


150kHz~30MHz




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       15 of 17

      The test was performed at a 10m test site. According to below formulate and the test data at 10m test
      distance,
      L300 / L10 = D10 / D300
      Note:
      L300: Level @ 300m distance. Unit: uV/m;
      L10: Level @ 10m distance. Unit: uV/m;
      D300: 300m distance. Unit: m
      D10: 10m distance. Unit: m
      The level at 300m test distance is below:


                                   Read Level                      Read Level                         Limit @
    Frequency                                                                                                                        Margin
                                     @ 10m                           @ 300m                            300m
      (MHz)                                                                                                                           (dB)
                                    (dBuV/m)                        (dBuV/m)                         (dBuV/m)
         0.01                         45.61                           -13.47                           23.52                          -37.00
         0.03                         45.23                           -13.85                           23.52                          -37.38
         0.14                         42.61                           -16.47                           23.52                          -40.00
         0.15                         48.88                           -10.20                           23.52                          -33.73
         1.22                         34.00                           -25.08                           23.52                          -48.61
         16.31                        14.42                           -44.66                           23.52                          -68.19




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       16 of 17



7         Photographs
7.1 Conducted disturbance Test Setup




7.2 Radiated emission Test Setup




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180600531301
                                                                                                                                 Page:       17 of 17

7.3 EUT Constructional Details (EUT Photos)
            Refer to EUT external and internal photos.



                                                                                   - End of the Report -




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.



Document Created: 2018-07-10 01:32:52
Document Modified: 2018-07-10 01:32:52
Download: ONB18WI706 Wireless Charging Stand Test Report SZEM180600531301-Part18, RPT Zhejiang Fousine Science &Technology; Co.Ltd.
Mirror Download [FCC.gov]ONB18WI706 Wireless Charging Stand Test Report SZEM180600531301-Part18, RPT Zhejiang Fousine Science &Technology; Co.Ltd.
Document ID3918343
Application IDfFmQ+5CoA7eVK4YOclm5Ew==
Document DescriptionTest Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize59.97kB (749669 bits)
Date Submitted2018-07-10 00:00:00
Date Available2018-07-10 00:00:00
Creation Date2018-07-10 09:32:50
Producing SoftwareGPL Ghostscript 8.64
Document Lastmod2018-07-10 01:32:52
Document TitleSZEM180600531301-Part18, RPT
Document CreatorPScript5.dll Version 5.2.2
Document Author: leo_lai