FCC ID 2AKQD-ORCA-50

2AKQDORCA-50, 2AKQD ORCA50, 2AKQD-0RCA-50, 2AKQD-ORCA-5O, 2AKQD-ORCA-50, 2AKQD-ORCA-S0, 2AKOD-ORCA-50, 2AK0D-ORCA-50

Shenzhen RodinBell Technology Co., Ltd. ORCA-50 Handheld Data Terminal -ORCA-50


An FCC ID is the product ID assigned by the FCC to identify wireless products in the market. The FCC chooses 3 or 5 character "Grantee" codes to identify the business that created the product. For example, the grantee code for FCC ID: 2AKQD-ORCA-50 is 2AKQD. The remaining characters of the FCC ID, -ORCA-50, are often associated with the product model, but they can be random. These letters are chosen by the applicant. In addition to the application, the FCC also publishes internal images, external images, user manuals, and test results for wireless devices. They can be under the "exhibits" tab below.

Purchase on Amazon: ORCA-50 Handheld Data Terminal

App # Purpose Date Unique ID
1 Original Equipment 2017-10-11 ByufGzZHZiZlRMXB/EAeXQ==
2 Original Equipment 2017-10-11 8RRtZczwMimV6MGcBr4sJw==
3 Original Equipment 2017-10-11 m7rsWXqHHDHep9UEI5NobQ==
4 Original Equipment 2017-10-11 tlcTlwyIOABF4ZAb5Pq6rg==

Operating Frequencies

Frequency RangePower OutputToleranceEmission DesignatorRule Parts App #
15B 1.1
706.5-713.5 MHz48 mW0.004ppm4M50G7D27 3.18
706.5-713.5 MHz49.9 mW0.004ppm4M51W7D27 3.19
709-711 MHz45.4 mW0.004ppm8M97G7D27 3.16
709-711 MHz49.8 mW0.003ppm8M98W7D27 3.17
824.7-848.3 MHz49.2 mW0.005ppm1M09G7D22H 3.14
824.7-848.3 MHz49.2 mW0.005ppm1M09W7D22H 3.15
829-844 MHz50 mW0.004ppm8M99G7D22H 3.12
829-844 MHz50 mW0.003ppm8M99W7D22H 3.13
902.5-927.5 MHz997.7 mW15C 4.2
1.7107-1.7543 GHz236.6 mW0.004ppm1M09G7D27 3.1
1.7107-1.7543 GHz184.1 mW0.005ppm1M09W7D27 3.11
1.7124-1.7526 GHz54.1 mW0.005ppm4M16F9W27 3.3
1.72-1.745 GHz231.2 mW0.004ppm17M9G7D27 3.8
1.72-1.745 GHz179.5 mW0.003ppm17M9W7D27 3.9
1.8507-1.9093 GHz158.1 mW0.008ppm1M09G7D24E 3.6
1.8507-1.9093 GHz92 mW0.008ppm1M09W7D24E 3.7
1.8524-1.9076 GHz120.5 mW0.005ppm4M16F9W24E 3.2
1.86-1.9 GHz97.7 mW0.008ppm18M0G7D24E 3.4
1.86-1.9 GHz96.4 mW0.008ppm18M0W7D24E 3.5
2.402-2.48 GHz Bluetooth4.67 mW15C 2.2
2.402-2.48 GHz Bluetooth4.8 mW15C 4.1
2.412-2.462 GHz 2.4 GHz WiFi40.27 mW15C 2.1

Exhibits

Available Exhibits

App # Document Type Submitted
Available
4 SAR reportRF Exposure Info
Adobe Acrobat PDF (5625 kB)
2017-10-10
2017-10-11
4 User manualUsers Manual
Adobe Acrobat PDF (2259 kB)
2017-10-10
2017-10-11
2 User manualUsers Manual
Adobe Acrobat PDF (2259 kB)
2017-10-10
2017-10-11
2 SAR reportRF Exposure Info
Adobe Acrobat PDF (5625 kB)
2017-10-10
2017-10-11
2 Test setupTest Setup Photos
Adobe Acrobat PDF (287 kB)
2017-10-10
2017-10-11
4 Test setupTest Setup Photos
Adobe Acrobat PDF (287 kB)
2017-10-10
2017-10-11
4 Test reportTest Report
Adobe Acrobat PDF (4611 kB)
2017-10-10
2017-10-11
2 Test reportTest Report
Adobe Acrobat PDF (4784 kB)
2017-10-10
2017-10-11
4 Internal photosInternal Photos
Adobe Acrobat PDF (5051 kB)
2017-10-10
2017-10-11
4 LabelID Label/Location Info
Adobe Acrobat PDF (61 kB)
2017-10-10
2017-10-11
2 Internal photosInternal Photos
Adobe Acrobat PDF (5051 kB)
2017-10-10
2017-10-11
4 External photosExternal Photos
Adobe Acrobat PDF (866 kB)
2017-10-10
2017-10-11
2 LabelID Label/Location Info
Adobe Acrobat PDF (61 kB)
2017-10-10
2017-10-11
2 External photosExternal Photos
Adobe Acrobat PDF (866 kB)
2017-10-10
2017-10-11
1 User manualUsers Manual
Adobe Acrobat PDF (2259 kB)
2017-10-10
2017-10-11
1 Test setupTest Setup Photos
Adobe Acrobat PDF (321 kB)
2017-10-10
2017-10-11
1 Test reportTest Report
Adobe Acrobat PDF (2350 kB)
2017-10-10
2017-10-11
1 Internal photosInternal Photos
Adobe Acrobat PDF (5051 kB)
2017-10-10
2017-10-11
1 LabelID Label/Location Info
Adobe Acrobat PDF (61 kB)
2017-10-10
2017-10-11
1 External photosExternal Photos
Adobe Acrobat PDF (866 kB)
2017-10-10
2017-10-11
3 User manualUsers Manual
Adobe Acrobat PDF (2259 kB)
2017-10-10
2017-10-11
3 Test setupTest Setup Photos
Adobe Acrobat PDF (233 kB)
2017-10-10
2017-10-11
3 SAR reportRF Exposure Info
Adobe Acrobat PDF (5625 kB)
2017-10-10
2017-10-11
3 Internal photosInternal Photos
Adobe Acrobat PDF (5051 kB)
2017-10-10
2017-10-11
3 LabelID Label/Location Info
Adobe Acrobat PDF (61 kB)
2017-10-10
2017-10-11
3 External photosExternal Photos
Adobe Acrobat PDF (866 kB)
2017-10-10
2017-10-11
3 Cover letterCover Letter(s)
Adobe Acrobat PDF (347 kB)
2017-10-10
2017-10-11
1 Cover letterCover Letter(s)
Adobe Acrobat PDF (347 kB)
2017-10-03
2017-10-11
4 Cover letterCover Letter(s)
Adobe Acrobat PDF (347 kB)
2017-10-03
2017-10-11
2 Cover letterCover Letter(s)
Adobe Acrobat PDF (347 kB)
2017-10-03
2017-10-11
3 Test report LTETest Report
Adobe Acrobat PDF (645 kB)
2017-10-03
2017-10-11
3 Test report WCDMATest Report
Adobe Acrobat PDF (443 kB)
2017-10-03
2017-10-11
3 Modular test report part 24Test Report
Adobe Acrobat PDF (2288 kB)
2017-10-03
2017-10-11
3 Modular test report part 23Test Report
Adobe Acrobat PDF (5006 kB)
2017-10-03
2017-10-11
3 Modular test report part 22Test Report
Adobe Acrobat PDF (4797 kB)
2017-10-03
2017-10-11
3 Modular test report part 21Test Report
Adobe Acrobat PDF (1402 kB)
2017-10-03
2017-10-11
3 Modular test report part 20Test Report
Adobe Acrobat PDF (4830 kB)
2017-10-03
2017-10-11
3 Modular test report part 19Test Report
Adobe Acrobat PDF (255 kB)
2017-10-03
2017-10-11
3 Modular test report part 18Test Report
Adobe Acrobat PDF (119 kB)
2017-10-03
2017-10-11
3 Modular test report part 17Test Report
Adobe Acrobat PDF (4266 kB)
2017-10-03
2017-10-11
3 Modular test report part 16Test Report
Adobe Acrobat PDF (4503 kB)
2017-10-03
2017-10-11
3 Modular test report part 15Test Report
Adobe Acrobat PDF (4051 kB)
2017-10-03
2017-10-11
3 Modular test report part 14Test Report
Adobe Acrobat PDF (3493 kB)
2017-10-03
2017-10-11
3 Modular test report part 13Test Report
Adobe Acrobat PDF (4444 kB)
2017-10-03
2017-10-11
3 Modular test report part 12Test Report
Adobe Acrobat PDF (4464 kB)
2017-10-03
2017-10-11
3 Modular test report part 11Test Report
Adobe Acrobat PDF (3799 kB)
2017-10-03
2017-10-11
3 Modular test report part 10Test Report
Adobe Acrobat PDF (874 kB)
2017-10-03
2017-10-11
3 Modular test report part 9Test Report
Adobe Acrobat PDF (4405 kB)
2017-10-03
2017-10-11
3 Modular test report part 8Test Report
Adobe Acrobat PDF (4487 kB)
2017-10-03
2017-10-11
3 Modular test report part 7Test Report
Adobe Acrobat PDF (3944 kB)
2017-10-03
2017-10-11
3 Modular test report part 6Test Report
Adobe Acrobat PDF (3220 kB)
2017-10-03
2017-10-11
3 Modular test report part 5Test Report
Adobe Acrobat PDF (5004 kB)
2017-10-03
2017-10-11
3 Modular test report part 4Test Report
Adobe Acrobat PDF (4482 kB)
2017-10-03
2017-10-11
3 Modular test report part 3Test Report
Adobe Acrobat PDF (4305 kB)
2017-10-03
2017-10-11
3 Modular test report part 2Test Report
Adobe Acrobat PDF (5029 kB)
2017-10-03
2017-10-11
3 Modular test report part 1Test Report
Adobe Acrobat PDF (374 kB)
2017-10-03
2017-10-11

APP # 4 (2017-10-11)

App # Document Type Submitted
Available
4 SAR report RF Exposure Info
Adobe Acrobat PDF (5625 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
4 User manual Users Manual
Adobe Acrobat PDF (2259 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00

APP # 2 (2017-10-11)

App # Document Type Submitted
Available
2 User manual Users Manual
Adobe Acrobat PDF (2259 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
2 SAR report RF Exposure Info
Adobe Acrobat PDF (5625 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
2 Test setup Test Setup Photos
Adobe Acrobat PDF (287 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00

APP # 4 (2017-10-11)

App # Document Type Submitted
Available
4 Test setup Test Setup Photos
Adobe Acrobat PDF (287 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
4 Test report Test Report
Adobe Acrobat PDF (4611 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00

APP # 2 (2017-10-11)

App # Document Type Submitted
Available
2 Test report Test Report
Adobe Acrobat PDF (4784 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00

APP # 4 (2017-10-11)

App # Document Type Submitted
Available
4 Internal photos Internal Photos
Adobe Acrobat PDF (5051 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
4 Label ID Label/Location Info
Adobe Acrobat PDF (61 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00

APP # 2 (2017-10-11)

App # Document Type Submitted
Available
2 Internal photos Internal Photos
Adobe Acrobat PDF (5051 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00

APP # 4 (2017-10-11)

App # Document Type Submitted
Available
4 External photos External Photos
Adobe Acrobat PDF (866 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00

APP # 2 (2017-10-11)

App # Document Type Submitted
Available
2 Label ID Label/Location Info
Adobe Acrobat PDF (61 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
2 External photos External Photos
Adobe Acrobat PDF (866 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00

APP # 1 (2017-10-11)

App # Document Type Submitted
Available
1 User manual Users Manual
Adobe Acrobat PDF (2259 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
1 Test setup Test Setup Photos
Adobe Acrobat PDF (321 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
1 Test report Test Report
Adobe Acrobat PDF (2350 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
1 Internal photos Internal Photos
Adobe Acrobat PDF (5051 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
1 Label ID Label/Location Info
Adobe Acrobat PDF (61 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
1 External photos External Photos
Adobe Acrobat PDF (866 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00

APP # 3 (2017-10-11)

App # Document Type Submitted
Available
3 User manual Users Manual
Adobe Acrobat PDF (2259 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
3 Test setup Test Setup Photos
Adobe Acrobat PDF (233 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
3 SAR report RF Exposure Info
Adobe Acrobat PDF (5625 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
3 Internal photos Internal Photos
Adobe Acrobat PDF (5051 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
3 Label ID Label/Location Info
Adobe Acrobat PDF (61 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
3 External photos External Photos
Adobe Acrobat PDF (866 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00
3 Cover letter Cover Letter(s)
Adobe Acrobat PDF (347 kB)
2017-10-10 00:00:00
2017-10-11 00:00:00

APP # 1 (2017-10-11)

App # Document Type Submitted
Available
1 Cover letter Cover Letter(s)
Adobe Acrobat PDF (347 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00

APP # 4 (2017-10-11)

App # Document Type Submitted
Available
4 Cover letter Cover Letter(s)
Adobe Acrobat PDF (347 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00

APP # 2 (2017-10-11)

App # Document Type Submitted
Available
2 Cover letter Cover Letter(s)
Adobe Acrobat PDF (347 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00

APP # 3 (2017-10-11)

App # Document Type Submitted
Available
3 Test report LTE Test Report
Adobe Acrobat PDF (645 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Test report WCDMA Test Report
Adobe Acrobat PDF (443 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 24 Test Report
Adobe Acrobat PDF (2288 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 23 Test Report
Adobe Acrobat PDF (5006 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 22 Test Report
Adobe Acrobat PDF (4797 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 21 Test Report
Adobe Acrobat PDF (1402 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 20 Test Report
Adobe Acrobat PDF (4830 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 19 Test Report
Adobe Acrobat PDF (255 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 18 Test Report
Adobe Acrobat PDF (119 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 17 Test Report
Adobe Acrobat PDF (4266 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 16 Test Report
Adobe Acrobat PDF (4503 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 15 Test Report
Adobe Acrobat PDF (4051 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 14 Test Report
Adobe Acrobat PDF (3493 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 13 Test Report
Adobe Acrobat PDF (4444 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 12 Test Report
Adobe Acrobat PDF (4464 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 11 Test Report
Adobe Acrobat PDF (3799 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 10 Test Report
Adobe Acrobat PDF (874 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 9 Test Report
Adobe Acrobat PDF (4405 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 8 Test Report
Adobe Acrobat PDF (4487 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 7 Test Report
Adobe Acrobat PDF (3944 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 6 Test Report
Adobe Acrobat PDF (3220 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 5 Test Report
Adobe Acrobat PDF (5004 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 4 Test Report
Adobe Acrobat PDF (4482 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 3 Test Report
Adobe Acrobat PDF (4305 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 2 Test Report
Adobe Acrobat PDF (5029 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00
3 Modular test report part 1 Test Report
Adobe Acrobat PDF (374 kB)
2017-10-03 00:00:00
2017-10-11 00:00:00

APP # 4 (2017-10-11)

App # Document Type Submitted
Available
4 Tune up Parts List/Tune Up Info
Adobe Acrobat PDF (55 kB)
2017-10-10 00:00:00
N/A

APP # 1 (2017-10-11)

App # Document Type Submitted
Available
1 Block Diagram Block Diagram
Adobe Acrobat PDF (47 kB)
2017-10-10 00:00:00
N/A

APP # 3 (2017-10-11)

App # Document Type Submitted
Available
3 Tune up Parts List/Tune Up Info
Adobe Acrobat PDF (55 kB)
2017-10-10 00:00:00
N/A

APP # 4 (2017-10-11)

App # Document Type Submitted
Available
4 Schematics Schematics
Adobe Acrobat PDF (635 kB)
2017-10-10 00:00:00
N/A
4 Block Diagram Block Diagram
Adobe Acrobat PDF (47 kB)
2017-10-10 00:00:00
N/A

APP # 1 (2017-10-11)

App # Document Type Submitted
Available
1 Operational Description Operational Description
Adobe Acrobat PDF (180 kB)
2017-10-10 00:00:00
N/A

APP # 3 (2017-10-11)

App # Document Type Submitted
Available
3 Parts list Parts List/Tune Up Info
Adobe Acrobat PDF (84 kB)
2017-10-10 00:00:00
N/A

APP # 2 (2017-10-11)

App # Document Type Submitted
Available
2 Parts list Parts List/Tune Up Info
Adobe Acrobat PDF (84 kB)
2017-10-10 00:00:00
N/A

APP # 4 (2017-10-11)

App # Document Type Submitted
Available
4 Operational Description Operational Description
Adobe Acrobat PDF (180 kB)
2017-10-10 00:00:00
N/A

APP # 1 (2017-10-11)

App # Document Type Submitted
Available
1 Schematics Schematics
Adobe Acrobat PDF (635 kB)
2017-10-10 00:00:00
N/A

APP # 2 (2017-10-11)

App # Document Type Submitted
Available
2 Tune up Parts List/Tune Up Info
Adobe Acrobat PDF (55 kB)
2017-10-10 00:00:00
N/A
2 Block Diagram Block Diagram
Adobe Acrobat PDF (47 kB)
2017-10-10 00:00:00
N/A

APP # 3 (2017-10-11)

App # Document Type Submitted
Available
3 Schematics Schematics
Adobe Acrobat PDF (635 kB)
2017-10-10 00:00:00
N/A

APP # 2 (2017-10-11)

App # Document Type Submitted
Available
2 Schematics Schematics
Adobe Acrobat PDF (635 kB)
2017-10-10 00:00:00
N/A

APP # 3 (2017-10-11)

App # Document Type Submitted
Available
3 Block Diagram Block Diagram
Adobe Acrobat PDF (17 kB)
2017-10-10 00:00:00
N/A
3 Operational Description Operational Description
Adobe Acrobat PDF (180 kB)
2017-10-10 00:00:00
N/A

APP # 2 (2017-10-11)

App # Document Type Submitted
Available
2 Operational Description Operational Description
Adobe Acrobat PDF (180 kB)
2017-10-10 00:00:00
N/A

APP # 1 (2017-10-11)

App # Document Type Submitted
Available
1 Parts list Parts List/Tune Up Info
Adobe Acrobat PDF (84 kB)
2017-10-10 00:00:00
N/A

APP # 4 (2017-10-11)

App # Document Type Submitted
Available
4 Parts list Parts List/Tune Up Info
Adobe Acrobat PDF (84 kB)
2017-10-10 00:00:00
N/A

Application Forms

Application for Equipment Authorization FCC Form 731 TCB Version


Applicant Information
Applicant's complete, legal business name: Shenzhen RodinBell Technology Co., Ltd.
FCC Registration Number (FRN): 0026131482
Alphanumeric FCC ID: 2AKQDORCA50
Unique Application Identifier: ByufGzZHZiZlRMXB/EAeXQ==
Line one: 905#, Tower B, Xinghe WORLD, Wuhe Avenue,
Line two: Longgang District
City: Shenzhen
State: N/A
Country: China

TCB Information
TCB Application Email Address: [email protected]
TCB Scope: A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices

FCC ID
Grantee Code: 2AKQD
Product Code: -ORCA-50

Person at the applicant's address to receive grant or for contact
Name: Alex Luo
Telephone Number: 86-0755-28225530 Extension:
Fax Number: 86-0755-89373021
Email: [email protected]
Long-Term Confidentiality
Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:   Yes

Short-Term Confidentiality
Does short-term confidentiality apply to this application?:   No
If so, specify the short-term confidentiality release date (MM/DD/YYYY format):  
Note: If no date is supplied, the release date will be set to 45 calendar days past the date of grant.

Software Defined/Cognitive Radio
Is this application for software defined/cognitive radio authorization?   No

Equipment Class
Equipment Class:   JBP - Part 15 Class B Computing Device Peripheral
Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant): ORCA-50 Handheld Data Terminal

Related OET KnowledgeDataBase Inquiry
Is there a KDB inquiry associated with this application?  No

Modular Equipment
Modular Type:  Does not apply

Application Purpose
Application is for:   Original Equipment

Composite/Related Equipment
Is the equipment in this application a composite device subject to an additional equipment authorization?   Yes
Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization?   No


Test Firm Information
Name of test firm and contact person on file with the FCC:
Firm Name:   Shenzhen Zhongjian Nanfang Testing Co.,Ltd
First Name:   Bruce
Last Name:   Zhang
Telephone Number: 86-755-23118282 Extension:
Fax Number:  86-755-23116366
E-mail:  [email protected]

Grant Comments
Set the grant of this application to be deferred to a specified date:
No

Equipment Authorization Waiver
Is there an equipment authorization waiver associated with this application?  No
If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded?:  No

WILLFUL FALSE STATEMENTS MADE ON THIS FORM ARE PUNISHABLE BY FINE AND IMPRISONMENT (U.S. CODE, TITLE 18, SECTION 1001), AND/OR REVOCATION OF ANY STATION LICENSE OR CONSTRUCTION PERMIT (U.S. CODE, TITLE 47, SECTION 312(a)(1)), AND/OR FORFEITURE (U.S. CODE, TITLE 47, SECTION 503).

SECTION 5301 (ANTI-DRUG ABUSE) CERTIFICATION:
The applicant must certify that neither the applicant nor any party to the application is subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes.

Does the applicant or authorized agent so certify?  Yes

Applicant/Agent Certification:

I certify that I am authorized to sign this application. All of the statements herein and the exhibits attached hereto, are true and correct to the best of my knowledge and belief. In accepting a Grant of Equipment Authorization as a result of the representations made in this application, the applicant is responsible for (1) labeling the equipment with the exact FCC ID specified in this application, (2) compliance statement labeling pursuant to the applicable rules, and (3) compliance of the equipment with the applicable technical rules. If the applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC's technical requirements.

Authorizing an agent to sign this application, is done solely at the applicant's discretion; however, the applicant remains responsible for all statements in this application.

If an agent has signed this application on behalf of the applicant, a written letter of authorization which includes information to enable the agent to respond to the above section 5301 (Anti-Drug Abuse) Certification statement has been provided by the applicant. It is understood that the letter of authorization must be submitted to the FCC upon request, and that the FCC reserves the right to contact the applicant directly at any time.

Signature of Authorized Person Filing:  Bruce Zhang
Title of authorized signature:  EMC Laboratory Manager

Application for Equipment Authorization FCC Form 731 TCB Version


Applicant Information
Applicant's complete, legal business name: Shenzhen RodinBell Technology Co., Ltd.
FCC Registration Number (FRN): 0026131482
Alphanumeric FCC ID: 2AKQDORCA50
Unique Application Identifier: 8RRtZczwMimV6MGcBr4sJw==
Line one: 905#, Tower B, Xinghe WORLD, Wuhe Avenue,
Line two: Longgang District
City: Shenzhen
State: N/A
Country: China

TCB Information
TCB Application Email Address: [email protected]
TCB Scope: A4: UNII devices & low power transmitters using spread spectrum techniques

FCC ID
Grantee Code: 2AKQD
Product Code: -ORCA-50

Person at the applicant's address to receive grant or for contact
Name: Alex Luo
Telephone Number: 86-0755-28225530 Extension:
Fax Number: 86-0755-89373021
Email: [email protected]
Long-Term Confidentiality
Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:   Yes

Short-Term Confidentiality
Does short-term confidentiality apply to this application?:   No
If so, specify the short-term confidentiality release date (MM/DD/YYYY format):  
Note: If no date is supplied, the release date will be set to 45 calendar days past the date of grant.

Software Defined/Cognitive Radio
Is this application for software defined/cognitive radio authorization?   No

Equipment Class
Equipment Class:   DTS - Digital Transmission System
Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant): ORCA-50 Handheld Data Terminal

Related OET KnowledgeDataBase Inquiry
Is there a KDB inquiry associated with this application?  No

Modular Equipment
Modular Type:  Does not apply

Application Purpose
Application is for:   Original Equipment

Composite/Related Equipment
Is the equipment in this application a composite device subject to an additional equipment authorization?   Yes
Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization?   No


Test Firm Information
Name of test firm and contact person on file with the FCC:
Firm Name:   Shenzhen Zhongjian Nanfang Testing Co.,Ltd
First Name:   Bruce
Last Name:   Zhang
Telephone Number: 86-755-23118282 Extension:
Fax Number:  86-755-23116366
E-mail:  [email protected]

Grant Comments
Enter any text that you would like to appear at the bottom of the Grant of Equipment Authorization:
Output power listed is conducted. The highest reported SAR for extremity (hand) exposure conditions is < 0.10 W/kg. End-users must be informed of transmitter operating conditions for satisfying RF exposure compliance.
Set the grant of this application to be deferred to a specified date:
No

Equipment Authorization Waiver
Is there an equipment authorization waiver associated with this application?  No
If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded?:  No

WILLFUL FALSE STATEMENTS MADE ON THIS FORM ARE PUNISHABLE BY FINE AND IMPRISONMENT (U.S. CODE, TITLE 18, SECTION 1001), AND/OR REVOCATION OF ANY STATION LICENSE OR CONSTRUCTION PERMIT (U.S. CODE, TITLE 47, SECTION 312(a)(1)), AND/OR FORFEITURE (U.S. CODE, TITLE 47, SECTION 503).

SECTION 5301 (ANTI-DRUG ABUSE) CERTIFICATION:
The applicant must certify that neither the applicant nor any party to the application is subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes.

Does the applicant or authorized agent so certify?  Yes

Applicant/Agent Certification:

I certify that I am authorized to sign this application. All of the statements herein and the exhibits attached hereto, are true and correct to the best of my knowledge and belief. In accepting a Grant of Equipment Authorization as a result of the representations made in this application, the applicant is responsible for (1) labeling the equipment with the exact FCC ID specified in this application, (2) compliance statement labeling pursuant to the applicable rules, and (3) compliance of the equipment with the applicable technical rules. If the applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC's technical requirements.

Authorizing an agent to sign this application, is done solely at the applicant's discretion; however, the applicant remains responsible for all statements in this application.

If an agent has signed this application on behalf of the applicant, a written letter of authorization which includes information to enable the agent to respond to the above section 5301 (Anti-Drug Abuse) Certification statement has been provided by the applicant. It is understood that the letter of authorization must be submitted to the FCC upon request, and that the FCC reserves the right to contact the applicant directly at any time.

Signature of Authorized Person Filing:  Bruce Zhang
Title of authorized signature:  EMC Laboratory Manager

Application for Equipment Authorization FCC Form 731 TCB Version


Applicant Information
Applicant's complete, legal business name: Shenzhen RodinBell Technology Co., Ltd.
FCC Registration Number (FRN): 0026131482
Alphanumeric FCC ID: 2AKQDORCA50
Unique Application Identifier: m7rsWXqHHDHep9UEI5NobQ==
Line one: 905#, Tower B, Xinghe WORLD, Wuhe Avenue,
Line two: Longgang District
City: Shenzhen
State: N/A
Country: China

TCB Information
TCB Application Email Address: [email protected]
TCB Scope: B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27

FCC ID
Grantee Code: 2AKQD
Product Code: -ORCA-50

Person at the applicant's address to receive grant or for contact
Name: Alex Luo
Telephone Number: 86-0755-28225530 Extension:
Fax Number: 86-0755-89373021
Email: [email protected]
Long-Term Confidentiality
Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:   Yes

Short-Term Confidentiality
Does short-term confidentiality apply to this application?:   No
If so, specify the short-term confidentiality release date (MM/DD/YYYY format):  
Note: If no date is supplied, the release date will be set to 45 calendar days past the date of grant.

Software Defined/Cognitive Radio
Is this application for software defined/cognitive radio authorization?   No

Equipment Class
Equipment Class:   PCB - PCS Licensed Transmitter
Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant): ORCA-50 Handheld Data Terminal

Related OET KnowledgeDataBase Inquiry
Is there a KDB inquiry associated with this application?  Yes

Modular Equipment
Modular Type:  Does not apply

Application Purpose
Application is for:   Original Equipment

Composite/Related Equipment
Is the equipment in this application a composite device subject to an additional equipment authorization?   Yes
Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization?   No


Test Firm Information
Name of test firm and contact person on file with the FCC:
Firm Name:   Shenzhen Zhongjian Nanfang Testing Co.,Ltd
First Name:   Bruce
Last Name:   Zhang
Telephone Number: 86-755-23118282 Extension:
Fax Number:  86-755-23116366
E-mail:  [email protected]

Grant Comments
Enter any text that you would like to appear at the bottom of the Grant of Equipment Authorization:
Power output listed is ERP for Part 22 and Part 27 below 1 GHz, EIRP for Part 24 and Part 27 above 1 GHz. The highest reported SAR for extremity (hand) exposure conditions is 1.67 W/kg. End-users must be informed of the operating requirements for satisfying RF exposure compliance. This device contains functions that are not operational in the U.S. Territories. This filing is only applicable for U.S. operations.
Set the grant of this application to be deferred to a specified date:
No

Equipment Authorization Waiver
Is there an equipment authorization waiver associated with this application?  No
If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded?:  No

WILLFUL FALSE STATEMENTS MADE ON THIS FORM ARE PUNISHABLE BY FINE AND IMPRISONMENT (U.S. CODE, TITLE 18, SECTION 1001), AND/OR REVOCATION OF ANY STATION LICENSE OR CONSTRUCTION PERMIT (U.S. CODE, TITLE 47, SECTION 312(a)(1)), AND/OR FORFEITURE (U.S. CODE, TITLE 47, SECTION 503).

SECTION 5301 (ANTI-DRUG ABUSE) CERTIFICATION:
The applicant must certify that neither the applicant nor any party to the application is subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes.

Does the applicant or authorized agent so certify?  Yes

Applicant/Agent Certification:

I certify that I am authorized to sign this application. All of the statements herein and the exhibits attached hereto, are true and correct to the best of my knowledge and belief. In accepting a Grant of Equipment Authorization as a result of the representations made in this application, the applicant is responsible for (1) labeling the equipment with the exact FCC ID specified in this application, (2) compliance statement labeling pursuant to the applicable rules, and (3) compliance of the equipment with the applicable technical rules. If the applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC's technical requirements.

Authorizing an agent to sign this application, is done solely at the applicant's discretion; however, the applicant remains responsible for all statements in this application.

If an agent has signed this application on behalf of the applicant, a written letter of authorization which includes information to enable the agent to respond to the above section 5301 (Anti-Drug Abuse) Certification statement has been provided by the applicant. It is understood that the letter of authorization must be submitted to the FCC upon request, and that the FCC reserves the right to contact the applicant directly at any time.

Signature of Authorized Person Filing:  Bruce Zhang
Title of authorized signature:  EMC Laboratory Manager

Application for Equipment Authorization FCC Form 731 TCB Version


Applicant Information
Applicant's complete, legal business name: Shenzhen RodinBell Technology Co., Ltd.
FCC Registration Number (FRN): 0026131482
Alphanumeric FCC ID: 2AKQDORCA50
Unique Application Identifier: tlcTlwyIOABF4ZAb5Pq6rg==
Line one: 905#, Tower B, Xinghe WORLD, Wuhe Avenue,
Line two: Longgang District
City: Shenzhen
State: N/A
Country: China

TCB Information
TCB Application Email Address: [email protected]
TCB Scope: A4: UNII devices & low power transmitters using spread spectrum techniques

FCC ID
Grantee Code: 2AKQD
Product Code: -ORCA-50

Person at the applicant's address to receive grant or for contact
Name: Alex Luo
Telephone Number: 86-0755-28225530 Extension:
Fax Number: 86-0755-89373021
Email: [email protected]
Long-Term Confidentiality
Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:   Yes

Short-Term Confidentiality
Does short-term confidentiality apply to this application?:   No
If so, specify the short-term confidentiality release date (MM/DD/YYYY format):  
Note: If no date is supplied, the release date will be set to 45 calendar days past the date of grant.

Software Defined/Cognitive Radio
Is this application for software defined/cognitive radio authorization?   No

Equipment Class
Equipment Class:   DSS - Part 15 Spread Spectrum Transmitter
Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant): ORCA-50 Handheld Data Terminal

Related OET KnowledgeDataBase Inquiry
Is there a KDB inquiry associated with this application?  Yes

Modular Equipment
Modular Type:  Does not apply

Application Purpose
Application is for:   Original Equipment

Composite/Related Equipment
Is the equipment in this application a composite device subject to an additional equipment authorization?   Yes
Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization?   No


Test Firm Information
Name of test firm and contact person on file with the FCC:
Firm Name:   Shenzhen Zhongjian Nanfang Testing Co.,Ltd
First Name:   Bruce
Last Name:   Zhang
Telephone Number: 86-755-23118282 Extension:
Fax Number:  86-755-23116366
E-mail:  [email protected]

Grant Comments
Enter any text that you would like to appear at the bottom of the Grant of Equipment Authorization:
Output power listed is conducted. The highest reported SAR for extremity (hand) exposure conditions is 1.42 W/kg. End-users must be informed of transmitter operating conditions for satisfying RF exposure compliance.
Set the grant of this application to be deferred to a specified date:
No

Equipment Authorization Waiver
Is there an equipment authorization waiver associated with this application?  No
If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded?:  No

WILLFUL FALSE STATEMENTS MADE ON THIS FORM ARE PUNISHABLE BY FINE AND IMPRISONMENT (U.S. CODE, TITLE 18, SECTION 1001), AND/OR REVOCATION OF ANY STATION LICENSE OR CONSTRUCTION PERMIT (U.S. CODE, TITLE 47, SECTION 312(a)(1)), AND/OR FORFEITURE (U.S. CODE, TITLE 47, SECTION 503).

SECTION 5301 (ANTI-DRUG ABUSE) CERTIFICATION:
The applicant must certify that neither the applicant nor any party to the application is subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes.

Does the applicant or authorized agent so certify?  Yes

Applicant/Agent Certification:

I certify that I am authorized to sign this application. All of the statements herein and the exhibits attached hereto, are true and correct to the best of my knowledge and belief. In accepting a Grant of Equipment Authorization as a result of the representations made in this application, the applicant is responsible for (1) labeling the equipment with the exact FCC ID specified in this application, (2) compliance statement labeling pursuant to the applicable rules, and (3) compliance of the equipment with the applicable technical rules. If the applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC's technical requirements.

Authorizing an agent to sign this application, is done solely at the applicant's discretion; however, the applicant remains responsible for all statements in this application.

If an agent has signed this application on behalf of the applicant, a written letter of authorization which includes information to enable the agent to respond to the above section 5301 (Anti-Drug Abuse) Certification statement has been provided by the applicant. It is understood that the letter of authorization must be submitted to the FCC upon request, and that the FCC reserves the right to contact the applicant directly at any time.

Signature of Authorized Person Filing:  Bruce Zhang
Title of authorized signature:  EMC Laboratory Manager

Applications are submitted for FCC ID and Grant requests. Click an above application to view details

Grants

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 10/11/2017

Application Dated: 10/03/2017
Shenzhen RodinBell Technology Co., Ltd.
905#, Tower B, Xinghe WORLD, Wuhe Avenue,
Longgang District
Shenzhen,
China
 
Attention: Alex Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AKQD-ORCA-50
Name of Grantee:  Shenzhen RodinBell Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: ORCA-50 Handheld Data Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.04027  
15C 2402.0  -  2480.0 0.00467  

Output power listed is conducted. The highest reported SAR for extremity (hand) exposure conditions is < 0.10 W/kg. End-users must be informed of transmitter operating conditions for satisfying RF exposure compliance.

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen RodinBell Technology Co., Ltd.
905#, Tower B, Xinghe WORLD, Wuhe Avenue, Longgang District
Shenzhen,
China
  Date of Grant: 10/11/2017

Application Dated: 10/03/2017
 
Attention: Alex Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AKQD-ORCA-50
Name of Grantee:  Shenzhen RodinBell Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: ORCA-50 Handheld Data Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.04027  
15C 2402.0  -  2480.0 0.00467  

Output power listed is conducted. The highest reported SAR for extremity (hand) exposure conditions is < 0.10 W/kg. End-users must be informed of transmitter operating conditions for satisfying RF exposure compliance.



Mail To:


EA678084
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 10/11/2017

Application Dated: 10/03/2017
Shenzhen RodinBell Technology Co., Ltd.
905#, Tower B, Xinghe WORLD, Wuhe Avenue,
Longgang District
Shenzhen,
China
 
Attention: Alex Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AKQD-ORCA-50
Name of Grantee:  Shenzhen RodinBell Technology Co., Ltd.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: ORCA-50 Handheld Data Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15B  -       


COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen RodinBell Technology Co., Ltd.
905#, Tower B, Xinghe WORLD, Wuhe Avenue, Longgang District
Shenzhen,
China
  Date of Grant: 10/11/2017

Application Dated: 10/03/2017
 
Attention: Alex Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AKQD-ORCA-50
Name of Grantee:  Shenzhen RodinBell Technology Co., Ltd.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: ORCA-50 Handheld Data Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15B  -       



Mail To:


EA602642
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 10/11/2017

Application Dated: 10/03/2017
Shenzhen RodinBell Technology Co., Ltd.
905#, Tower B, Xinghe WORLD, Wuhe Avenue,
Longgang District
Shenzhen,
China
 
Attention: Alex Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AKQD-ORCA-50
Name of Grantee:  Shenzhen RodinBell Technology Co., Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: ORCA-50 Handheld Data Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 826.4  -  846.6 0.0217 0.003  PM 4M16F9W
24E 1852.4  -  1907.6 0.1205 0.005  PM 4M16F9W
27 1712.4  -  1752.6 0.0541 0.005  PM 4M16F9W
24E 1860.0  -  1900.0 0.0977 0.008  PM 18M0G7D
24E 1860.0  -  1900.0 0.0964 0.008  PM 18M0W7D
24E 1850.7  -  1909.3 0.1581 0.008  PM 1M09G7D
24E 1850.7  -  1909.3 0.092 0.008  PM 1M09W7D
27 1720.0  -  1745.0 0.2312 0.004  PM 17M9G7D
27 1720.0  -  1745.0 0.1795 0.003  PM 17M9W7D
27 1710.7  -  1754.3 0.2366 0.004  PM 1M09G7D
27 1710.7  -  1754.3 0.1841 0.005  PM 1M09W7D
22H 829.0  -  844.0 0.05 0.004  PM 8M99G7D
22H 829.0  -  844.0 0.05 0.003  PM 8M99W7D
22H 824.7  -  848.3 0.0492 0.005  PM 1M09G7D
22H 824.7  -  848.3 0.0492 0.005  PM 1M09W7D
27 709.0  -  711.0 0.0454 0.004  PM 8M97G7D
27 709.0  -  711.0 0.0498 0.003  PM 8M98W7D
27 706.5  -  713.5 0.048 0.004  PM 4M50G7D
27 706.5  -  713.5 0.0499 0.004  PM 4M51W7D

Power output listed is ERP for Part 22 and Part 27 below 1 GHz, EIRP for Part 24 and Part 27 above 1 GHz. The highest reported SAR for extremity (hand) exposure conditions is 1.67 W/kg. End-users must be informed of the operating requirements for satisfying RF exposure compliance. This device contains functions that are not operational in the U.S. Territories. This filing is only applicable for U.S. operations.

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen RodinBell Technology Co., Ltd.
905#, Tower B, Xinghe WORLD, Wuhe Avenue, Longgang District
Shenzhen,
China
  Date of Grant: 10/11/2017

Application Dated: 10/03/2017
 
Attention: Alex Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AKQD-ORCA-50
Name of Grantee:  Shenzhen RodinBell Technology Co., Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: ORCA-50 Handheld Data Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 826.4  -  846.6 0.0217 0.003  PM 4M16F9W
24E 1852.4  -  1907.6 0.1205 0.005  PM 4M16F9W
27 1712.4  -  1752.6 0.0541 0.005  PM 4M16F9W
24E 1860.0  -  1900.0 0.0977 0.008  PM 18M0G7D
24E 1860.0  -  1900.0 0.0964 0.008  PM 18M0W7D
24E 1850.7  -  1909.3 0.1581 0.008  PM 1M09G7D
24E 1850.7  -  1909.3 0.092 0.008  PM 1M09W7D
27 1720.0  -  1745.0 0.2312 0.004  PM 17M9G7D
27 1720.0  -  1745.0 0.1795 0.003  PM 17M9W7D
27 1710.7  -  1754.3 0.2366 0.004  PM 1M09G7D
27 1710.7  -  1754.3 0.1841 0.005  PM 1M09W7D
22H 829.0  -  844.0 0.05 0.004  PM 8M99G7D
22H 829.0  -  844.0 0.05 0.003  PM 8M99W7D
22H 824.7  -  848.3 0.0492 0.005  PM 1M09G7D
22H 824.7  -  848.3 0.0492 0.005  PM 1M09W7D
27 709.0  -  711.0 0.0454 0.004  PM 8M97G7D
27 709.0  -  711.0 0.0498 0.003  PM 8M98W7D
27 706.5  -  713.5 0.048 0.004  PM 4M50G7D
27 706.5  -  713.5 0.0499 0.004  PM 4M51W7D

Power output listed is ERP for Part 22 and Part 27 below 1 GHz, EIRP for Part 24 and Part 27 above 1 GHz. The highest reported SAR for extremity (hand) exposure conditions is 1.67 W/kg. End-users must be informed of the operating requirements for satisfying RF exposure compliance. This device contains functions that are not operational in the U.S. Territories. This filing is only applicable for U.S. operations.



Mail To:


EA750428
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 10/11/2017

Application Dated: 10/03/2017
Shenzhen RodinBell Technology Co., Ltd.
905#, Tower B, Xinghe WORLD, Wuhe Avenue,
Longgang District
Shenzhen,
China
 
Attention: Alex Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AKQD-ORCA-50
Name of Grantee:  Shenzhen RodinBell Technology Co., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: ORCA-50 Handheld Data Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0048  
15C 902.5  -  927.5 0.9977  

Output power listed is conducted. The highest reported SAR for extremity (hand) exposure conditions is 1.42 W/kg. End-users must be informed of transmitter operating conditions for satisfying RF exposure compliance.

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen RodinBell Technology Co., Ltd.
905#, Tower B, Xinghe WORLD, Wuhe Avenue, Longgang District
Shenzhen,
China
  Date of Grant: 10/11/2017

Application Dated: 10/03/2017
 
Attention: Alex Luo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AKQD-ORCA-50
Name of Grantee:  Shenzhen RodinBell Technology Co., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: ORCA-50 Handheld Data Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0048  
15C 902.5  -  927.5 0.9977  

Output power listed is conducted. The highest reported SAR for extremity (hand) exposure conditions is 1.42 W/kg. End-users must be informed of transmitter operating conditions for satisfying RF exposure compliance.



Mail To:


EA913305

Grants authorize equipment for operation at approved frequencies and sale within the USA. Click an above grant to view details


Facebook Twitter Google+ RSS © FCCID.io 2017