FCC ID 2AKZUFW14
Building Automation System
by EasyIO Holdings Pte. Ltd.
Grantee Code: 2AKZU Product Code: FW14
Latest application date: 2017-06-21
FCC ID Device Details
| FCC ID | 2AKZUFW14 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AKZU |
| Product Code | FW14 |
| Applicant Business | EasyIO Holdings Pte. Ltd. 🇸🇬 |
| Related Domains | |
| Equipment Class | Building Automation System |
| Test Firm | Cerpass Technology (SuZhou) Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2017-06-21 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2017-06-21 | PDF 568.5 KB |
| Internal Photos | Internal Photos | 2017-06-21 | PDF 734.9 KB |
| External Photos | External Photos | 2017-06-21 | PDF 496.9 KB |
| ID Label | ID Label/Location Info | 2017-06-21 | PDF 155.6 KB |
| Label Location | ID Label/Location Info | 2017-06-21 | PDF 34.3 KB |
| Test Setup Photos | Test Setup Photos | 2017-06-21 | PDF 312.4 KB |
| Test Report | Test Report | 2017-06-21 | PDF 3.8 MB |
| Declaration of authorization | Cover Letter(s) | 2017-06-21 | PDF 138.7 KB |
| DoC Declaration FCC subpart 15B | Cover Letter(s) | 2017-06-21 | PDF 159.3 KB |
| confidentiality | Cover Letter(s) | 2017-06-21 | PDF 228.6 KB |
| MPE Report | RF Exposure Info | 2017-06-21 | PDF 24.5 KB |
| Block Diagram Metadata only | Block Diagram | PDF 36.6 KB | |
| Schematics Metadata only | Schematics | PDF 560.8 KB | |
| Operational Description Metadata only | Operational Description | PDF 28.4 KB |
Application Information
| Application ID | c8m0bhZOpBAVWqd+3zA+eQ== |
|---|---|
| Final Action Date | 2017-06-21 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0026167148 |
| Model | FW14 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Building Automation System |
| Responsible Party | Lim Hoon Chiat, Chief Technology Office, mccheah@easyio.com |
| Agent | Karen Karen Karen, Cerdex Technology Limited, 86-769-8547-1212 |
| Technical Contact | Lim Hoon Chiat, EasyIO Holdings Pte. Ltd., 6596656024 |
| Non-Technical Contact | Karen Tang, Cerdex Technology Limited, Karent@cerpass.net |
| Test Firm | Miro Chueh, Cerpass Technology (SuZhou) Co., Ltd., miroc@cerpass.net |
| TCB Email | certification@telefication.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| c8m0bhZOpBAVWqd+3zA+eQ== | 2017-06-21 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2412-2462 MHz | 0.5100000 | 15C |
Grants
TCB Grant - Application c8m0bhZOpBAVWqd+3zA+eQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Telefication B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 06/21/2017 Application Dated: 06/20/2017 |
| EasyIO Holdings Pte. Ltd. |
| 101 Cecil Street #09-07, Tong Eng Building |
| Singapore, 069533 Singapore |
| Attention: Lim Hoon Chiat , Chief Technology Office |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AKZUFW14 |
| Name of Grantee: | EasyIO Holdings Pte. Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Building Automation System |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.51 |
| Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes. |
EAS Grant - Application c8m0bhZOpBAVWqd+3zA+eQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
EasyIO Holdings Pte. Ltd. 101 Cecil Street #09-07, Tong Eng Building Singapore, 069533 Singapore |
Date of Grant: 06/21/2017 Application Dated: 06/20/2017 |
| Attention: Lim Hoon Chiat , Chief Technology Office |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AKZUFW14 |
| Name of Grantee: | EasyIO Holdings Pte. Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Building Automation System |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.51 |
| Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes. |