FCC ID 2AL54-M546
Care Predict
by CarePredict, Inc.
Grantee Code: 2AL54 Product Code: M546
Latest application date: 2022-12-19
FCC ID Device Details
| FCC ID | 2AL54-M546 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AL54 |
| Product Code | M546 |
| Applicant Business | CarePredict, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | Care Predict |
| Test Firm | Shenzhen Global Test Service Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2022-12-19 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2022-12-19 | PDF 3.9 MB |
| Internal Photos | Internal Photos | 2022-12-19 | PDF 2.1 MB |
| External Photos | External Photos | 2022-12-19 | PDF 1.1 MB |
| Label and location | ID Label/Location Info | 2022-12-19 | PDF 189.8 KB |
| Test photos | Test Setup Photos | 2022-12-19 | PDF 254 KB |
| Antenna specification | Test Report | 2022-12-19 | PDF 527.4 KB |
| Test Report | Test Report | 2022-12-19 | PDF 4.2 MB |
| test report | Test Report | 2022-12-19 | PDF 577.8 KB |
| Agent Authorization Rev 1.0 | Cover Letter(s) | 2022-12-19 | PDF 20 KB |
| Long Term Confidentiality | Cover Letter(s) | 2022-12-19 | PDF 63.8 KB |
| RF Exposure Evaluation | RF Exposure Info | 2022-12-19 | PDF 490.6 KB |
| Block Metadata only | Block Diagram | PDF 297.5 KB | |
| SCH Metadata only | Schematics | PDF 347.4 KB | |
| OP Metadata only | Operational Description | PDF 186.8 KB |
Application Information
| Application ID | hYhg3GXhI2Qj0K3nFxOjLQ== |
|---|---|
| Final Action Date | 2022-12-19 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0026533356 |
| Model | M546 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Care Predict |
| Responsible Party | Satish Movva, smovva@carepredict.com |
| Technical Contact | CarePredict, Inc., smovva@carepredict.net |
| Test Firm | Simon Hu, Shenzhen Global Test Service Co., Ltd., huxiaolong@gtscert.com |
| TCB Email | certification@micomlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| hYhg3GXhI2Qj0K3nFxOjLQ== | 2022-12-19 | Original Equipment |
Grants
TCB Grant - Application hYhg3GXhI2Qj0K3nFxOjLQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 12/19/2022 Application Dated: 12/19/2022 |
| CarePredict, Inc. |
| 324 S. University Dr |
| Plantation, FL 33324 |
| Attention: Satish Movva |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AL54-M546 |
| Name of Grantee: | CarePredict, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Care Predict |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0007 | |||
| 15C | 2412.0 - 2462.0 | 0.0072 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. |
EAS Grant - Application hYhg3GXhI2Qj0K3nFxOjLQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
CarePredict, Inc. 324 S. University Dr Plantation, FL 33324 United States |
Date of Grant: 12/19/2022 Application Dated: 12/19/2022 |
| Attention: Satish Movva |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AL54-M546 |
| Name of Grantee: | CarePredict, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Care Predict |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0007 | |||
| 15C | 2412.0 - 2462.0 | 0.0072 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. |
| Mail To: |