FCC ID 2AL5K-HUB216300

Site Interface Controller

by TNBI, Inc.

Grantee Code: 2AL5K   Product Code: HUB216300
Latest application date: 2018-01-26

FCC ID Device Details

FCC ID2AL5K-HUB216300
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AL5K
Product CodeHUB216300
Applicant BusinessTNBI, Inc. 🇺🇸
Related Domains bccpayments.com
Equipment ClassSite Interface Controller
Test FirmShenzhen NTEK Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
915 MHzOriginal Equipment2018-01-26

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2018-01-26PDF 402.2 KB
Internal photoInternal Photos2018-01-26PDF 395.3 KB
External photoExternal Photos2018-01-26PDF 471.3 KB
LabelID Label/Location Info2018-01-26PDF 202.4 KB
Test setup photoTest Setup Photos2018-01-26PDF 301 KB
Test reportTest Report2018-01-26PDF 803.2 KB
Authorization letterCover Letter(s)2018-01-26PDF 21.1 KB
Confidentiality request letterCover Letter(s)2018-01-26PDF 28.4 KB
RF exposureRF Exposure Info2018-01-26PDF 78.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 337.9 KB
Schematic Metadata onlySchematicsPDF 2.8 MB
Operational description Metadata onlyOperational DescriptionPDF 99.3 KB

Application Information

Application ID0lXAOxv+C1gKMQcWa4sTmQ==
Final Action Date2018-01-26
Application PurposeOriginal Equipment
Applicant FRN0026530352
ModelHUB216300
Frequency Range915 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSite Interface Controller
Responsible PartyCharles Pasquale, CEO, Charlie@bccpayments.com , 8888236782
Technical ContactJason Chen, Shenzhen NTEK Testing Technology Co., Ltd., jason_chen@ntek.org.cn , 86-755-61156588
Test FirmAlex Li, Shenzhen NTEK Testing Technology Co., Ltd., certification@ntek.org.cn , +86-755-6115-9384
TCB Emailmicomlabs_certification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
0lXAOxv+C1gKMQcWa4sTmQ==2018-01-26Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
915 MHz0.005800015C20

Grants

TCB Grant - Application 0lXAOxv+C1gKMQcWa4sTmQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 01/26/2018

Application Dated: 01/26/2018
TNBI, Inc.
Radnor Corporate Center
100 Matsonford Rd, Bldg 3, Ste 101
Radnor, PA 19087
 
Attention: Charles Pasquale , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AL5K-HUB216300
Name of Grantee:  TNBI, Inc.
Equipment Class: Digital Transmission System
Notes: Site Interface Controller
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 915.0  -  915.0 0.0058  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application 0lXAOxv+C1gKMQcWa4sTmQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

TNBI, Inc.
Radnor Corporate Center 100 Matsonford Rd, Bldg 3, Ste 101
Radnor, PA 19087
United States
  Date of Grant: 01/26/2018

Application Dated: 01/26/2018
 
Attention: Charles Pasquale , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AL5K-HUB216300
Name of Grantee:  TNBI, Inc.
Equipment Class: Digital Transmission System
Notes: Site Interface Controller
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 915.0  -  915.0 0.0058  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

Mail To: