FCC ID 2AL6R-ESGL01

Ultrasound Scanner

by BCF Technology Ltd

Grantee Code: 2AL6R   Product Code: ESGL01
Latest application date: 2018-03-14

FCC ID Device Details

FCC ID2AL6R-ESGL01
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AL6R
Product CodeESGL01
Applicant BusinessBCF Technology Ltd 🇬🇧
Related Domains bcftechnology.com
Equipment ClassUltrasound Scanner
Test FirmTUV SUD Product Service

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2018-03-14
2412-2462 MHzOriginal Equipment2018-03-13

Exhibits

DocumentTypeAvailableFile
Scan Go Manual full Eng Ver. LR AW V13 Dec 2017Users Manual2018-09-10PDF 332.3 KB
Charger Internal PhotosInternal Photos2018-09-10PDF 5.5 MB
Scanner Internal Photos_Part1Internal Photos2018-09-10PDF 5.9 MB
Scanner Internal Photos_Part2Internal Photos2018-09-10PDF 5.3 MB
Scanner Internal Photos_Part3Internal Photos2018-09-10PDF 812 KB
Belt Clip photosExternal Photos2018-09-10PDF 4.2 MB
Charger_Part1 photosExternal Photos2018-09-10PDF 5.4 MB
Charger_Part2 photosExternal Photos2018-09-10PDF 3.9 MB
ScannerExternal Photos2018-09-10PDF 1.8 MB
Charger labelID Label/Location Info2018-03-14PDF 108.9 KB
Label LocationID Label/Location Info2018-03-14PDF 1.3 MB
Scanner labelID Label/Location Info2018-03-14PDF 108.1 KB
75940063 FCC & IC Set Up Photos Issue 1Test Setup Photos2018-09-10PDF 682.9 KB
FR4O0971D_R01_Part15E_Texas_WG7837-T0B test reportTest Report2018-03-14PDF 1.9 MB
Test report 75940063-06 Issue 01Test Report2018-03-14PDF 393.4 KB
FR4O0971C_R01_Part15C_Texas_WG7837-T0B test reportTest Report2018-03-13PDF 2.8 MB
Wifi module integration statementTest Report2018-03-13PDF 56 KB
ESG Confidentiality RequestCover Letter(s)2018-03-14PDF 96.6 KB
Letter of authorityCover Letter(s)2018-03-14PDF 75.8 KB
Document 75940063 Report 07 Issue 1_Part1RF Exposure Info2018-03-14PDF 5.9 MB
Document 75940063 Report 07 Issue 1_Part2RF Exposure Info2018-03-14PDF 4.6 MB
SAR report 75940063 Report 07 Issue 1_Part1RF Exposure Info2018-03-13PDF 5.9 MB
SAR report 75940063 Report 07 Issue 1_Part2RF Exposure Info2018-03-13PDF 4.6 MB
ESG-Charger Block Diagram Metadata onlyBlock DiagramPDF 36.2 KB
ESGL01_BLOCK_DIAGRAM Metadata onlyBlock DiagramPDF 13.8 KB
Charger Schematics Metadata onlySchematicsPDF 823.7 KB
Scanner Schematics Metadata onlySchematicsPDF 4.8 MB
ESG-SCANNER-L - ANTENNA POSITION Metadata onlyOperational DescriptionPDF 190.1 KB
ESGL01 - Operating Description Metadata onlyOperational DescriptionPDF 200.2 KB
W3006 ANTENNA DATASHEET Metadata onlyOperational DescriptionPDF 1.4 MB
Wifi module integration statement Metadata onlyOperational DescriptionPDF 56 KB
XP Power ACDC Supply Metadata onlyOperational DescriptionPDF 452.1 KB
Charger Parts Metadata onlyParts List/Tune Up InfoPDF 211.9 KB
Scanner Parts Metadata onlyParts List/Tune Up InfoPDF 469.2 KB

Application Information

Application ID3mo/3KeviUNaJ8m7G+Tg9g==
Final Action Date2018-03-14
Application PurposeOriginal Equipment
Applicant FRN0026535971
ModelESGL01
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionUltrasound Scanner
Responsible PartyFabrizio Gaudenzi, Mr, fabrizio.gaudenzi@bcftechnology.com , +44 (0)1506 460 023
Test FirmMark Jenkins, TUV SUD Product Service, mark.jenkins@tuv-sud.co.uk , 00-44-1489-558258
TCB EmailALLEN.FERRY@BABT.COM
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date09/10/2018
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted. The highest reported SAR body-worn accessory, product specific (wireless router) and simultaneous transmission are 1.03 W/kg and 1.03 W/Kg respectively.

Applications

Application IDDatePurpose
3mo/3KeviUNaJ8m7G+Tg9g==2018-03-14Original Equipment
BVXO/TL+J1+sE1Xk/aMH7g==2018-03-13Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.115000015CCC
5180-5240 MHz0.038000015ECC

Grants

TCB Grant - Application BVXO/TL+J1+sE1Xk/aMH7g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  TUV SUD BABT
Octagon House, Concorde Way, Segensworth North,
Fareham, PO15 5RL
United Kingdom
Date of Grant: 03/13/2018

Application Dated: 03/13/2018
BCF Technology Ltd
Imaging House, Phoenix Crescent
Strathclyde Business Park
Belshill, Scotland, ML4 3NJ
United Kingdom
 
Attention: Fabrizio Gaudenzi , Mr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AL6R-ESGL01
Name of Grantee:  BCF Technology Ltd
Equipment Class: Digital Transmission System
Notes: Ultrasound Scanner
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.115  

Output power is conducted. SAR compliance for body worn operating configurations must be restricted to belt-clips described in this filing, and which contain no metallic component in the assembly. The highest reported SAR body-worn accessory, product specific (wireless router) and simultaneous transmission are 0.48 W/kg and 1.03 W/Kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application BVXO/TL+J1+sE1Xk/aMH7g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

BCF Technology Ltd
Imaging House, Phoenix Crescent Strathclyde Business Park
Belshill, Scotland, ML4 3NJ
United Kingdom
  Date of Grant: 03/13/2018

Application Dated: 03/13/2018
 
Attention: Fabrizio Gaudenzi , Mr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AL6R-ESGL01
Name of Grantee:  BCF Technology Ltd
Equipment Class: Digital Transmission System
Notes: Ultrasound Scanner
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.115  

Output power is conducted. SAR compliance for body worn operating configurations must be restricted to belt-clips described in this filing, and which contain no metallic component in the assembly. The highest reported SAR body-worn accessory, product specific (wireless router) and simultaneous transmission are 0.48 W/kg and 1.03 W/Kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 3mo/3KeviUNaJ8m7G+Tg9g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  TUV SUD BABT
Octagon House, Concorde Way, Segensworth North,
Fareham, PO15 5RL
United Kingdom
Date of Grant: 03/14/2018

Application Dated: 03/13/2018
BCF Technology Ltd
Imaging House, Phoenix Crescent
Strathclyde Business Park
Belshill, Scotland, ML4 3NJ
United Kingdom
 
Attention: Fabrizio Gaudenzi , Mr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AL6R-ESGL01
Name of Grantee:  BCF Technology Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Ultrasound Scanner
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.038  

Power output listed is conducted. The highest reported SAR body-worn accessory, product specific (wireless router) and simultaneous transmission are 1.03 W/kg and 1.03 W/Kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 3mo/3KeviUNaJ8m7G+Tg9g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

BCF Technology Ltd
Imaging House, Phoenix Crescent Strathclyde Business Park
Belshill, Scotland, ML4 3NJ
United Kingdom
  Date of Grant: 03/14/2018

Application Dated: 03/13/2018
 
Attention: Fabrizio Gaudenzi , Mr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AL6R-ESGL01
Name of Grantee:  BCF Technology Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Ultrasound Scanner
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.038  

Power output listed is conducted. The highest reported SAR body-worn accessory, product specific (wireless router) and simultaneous transmission are 1.03 W/kg and 1.03 W/Kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: