A81F Tablet PC Test Report CE EMC Haier International Business Corporation Limited
Haier International Business Corporation Limited Tablet PC
TEST REPORT FCC ID: 2ALAVA81F Product: Tablet PC Model No.: A81F Additional Model No.: Trade Mark: Report No.: TCT180126E010 Issued Date: January 22, 2018 Issued for: Haier International Business Corporation Limited Room 1602, 16th Floor, Tower A, No. 1 Ke Yuan Wei Yi Road, Lao Shan District, Qingdao, Shandong, China Issued By: Shenzhen Tongce Testing Lab. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China TEL: +86-755-27673339 FAX: +86-755-27673332 Note: This report shall not be reproduced except in full, without the written approval of Shenzhen Tongce Testing Lab. This document may be altered or revised by Shenzhen Tongce Testing Lab. personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample. Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 TABLE OF CONTENTS 1. Test Certification ..................................................................................... 3 2. Test Result Summary .............................................................................. 4 3. EUT Description ....................................................................................... 5 4. Genera Information.................................................................................. 7 4.1. TEST ENVIRONMENT AND MODE .............................................................................................................. 7 4.2. DESCRIPTION OF SUPPORT UNITS .......................................................................................................... 8 5. Facilities and Accreditations .................................................................. 9 5.1. FACILITIES ............................................................................................................................................ 9 5.2. LOCATION ............................................................................................................................................. 9 5.3. MEASUREMENT UNCERTAINTY ............................................................................................................... 9 6. Test Results and Measurement Data ................................................... 10 6.1. ANTENNA REQUIREMENT ...................................................................................................................... 10 6.2. CONDUCTED EMISSION ........................................................................................................................ 11 6.3. M AXIMUM CONDUCTED OUTPUT POWER .............................................................................................. 15 6.4. 6DB EMISSION BANDWIDTH ................................................................................................................. 18 6.5. 26DB BANDWIDTH AND 99% OCCUPIED BANDWIDTH ............................................................................ 23 6.6. POWER SPECTRAL DENSITY ................................................................................................................ 28 6.7. BAND EDGE ......................................................................................................................................... 37 6.8. SPURIOUS EMISSION............................................................................................................................ 46 6.9. FREQUENCY STABILITY MEASUREMENT................................................................................................ 55 Appendix A: Photographs of Test Setup Appendix B: Photographs of EUT Page 2 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 1. Test Certification Product: Tablet PC Model No.: A81F Additional Model No.: Trade Mark: Applicant: Haier International Business Corporation Limited Address: Room 1602, 16th Floor, Tower A, No. 1 Ke Yuan Wei Yi Road, Lao Shan District, Qingdao, Shandong, China Manufacturer: Haier International Business Corporation Limited Address: Room 1602, 16th Floor, Tower A, No. 1 Ke Yuan Wei Yi Road, Lao Shan District, Qingdao, Shandong, China Date of Test: January 06, 2018 - January 19, 2018 Applicable Standards: FCC CFR Title 47 Part 15 Subpart E Section 15.407: 2017 ANSI C63.10-2013 KDB789033 D02 General U-NII Test Procedures New Rules v02 The above equipment has been tested by Shenzhen Tongce Testing Lab. and found compliance with the requirements set forth in the technical standards mentioned above. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Tested By: Date: January 06, 2018 Date: January 17, 2018 Date: January 22, 2018 Brews Xu Reviewed By: Joe Zhou Approved By: Tomsin Page 3 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 2. Test Result Summary Requirement CFR 47 Section Result Antenna requirement §15.203 PASS AC Power Line Conducted Emission §15.207 PASS Maximum Conducted Output Power 6dB Emission Bandwidth §15.407(a) §2.1046 §15.407(a) §2.1049 PASS PASS 26dB Emission Bandwidth& §15.407(a) 99% Occupied Bandwidth §2.1049 Power Spectral Density §15.407(a) PASS Band edge §15.407(a) PASS Radiated Emission Frequency Stability §15.407(a) §2.1053 §15.407(g) §2.1055 PASS PASS PASS Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. Page 4 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 3. EUT Description Product: Tablet PC Model No.: A81F Additional Model No.: Trade Mark: Operation Frequency: Channel Bandwidth: Band I: 5180MHz-5240MHz; 5190MHz-5230MHz Band IV: 5745MHz-5825MHz; 5755MHz-5795MHz 802.11a/n(HT20): 20MHz 802.11n(HT40): 40MHz Modulation Technology: Orthogonal Frequency Division Multiplexing(OFDM) Modulation Type BPSK, QPSK, 16QAM, 64QAM Antenna Type: 1 Transmit, 1 Receive Antenna Gain: 1.0 dBi Power Supply: DC 3.7V for internal battery Adapter: Model: XHY050200UCC Input: 100-240Va.c., 50/60Hz, 0.5A Output: 5.0Vd.c., 2.0A Page 5 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Operation Frequency each of channel 20MHz Channel Frequency 36 5180 40 5200 44 5220 48 5240 149 5745 153 5765 157 5785 161 5805 165 5825 40MHz Channel Frequency 38 5190 46 5230 151 5755 159 5795 Note: In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle frequency, and the highest frequency of channel were selected to perform the test, and the selected channel see below: For 802.11a/n (HT20) Band I (5150 - 5250 MHz) Channel Number 36 44 48 Channel Frequency (MHz) Low Mid High 5180 5220 5240 Band IV (5725 - 5850 MHz) Channel Number 149 157 165 Channel Frequency (MHz) Low Mid High 5745 5785 5825 For 802.11n (HT40) Band I (5150 - 5250 MHz) Channel Number 38 46 Channel Frequency (MHz) Low High 5190 5230 Band IV (5725 - 5850 MHz) Channel Number 151 159 Channel Frequency (MHz) Low High 5755 5795 Page 6 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 4. Genera Information 4.1. Test environment and mode Operating Environment: Temperature: 25.0 C Humidity: 56 % RH Atmospheric Pressure: 1010 mbar Test Mode: Engineering mode: Keep the EUT in continuous transmitting by select channel and modulations(The value of duty cycle is 100%) The sample was placed 0.8m/1.5m for blow/above 1GHz above the ground plane of 3m chamber. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown in Test Results of the following pages. We have verified the construction and function in typical operation. All the test modes were carried out with the EUT in transmitting operation, which was shown in this test report and defined as follows: Per-scan all kind of data rate in lowest channel, and found the follow list which it was worst case. Mode Data rate 802.11a 6 Mbps 802.11n(HT20) MCS0 802.11n(HT40) MCS0 Final Test Mode: Operation mode: Keep the EUT in continuous transmitting with modulation Page 7 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 4.2. Description of Support Units The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Equipment Model No. Serial No. FCC ID Trade Name Note: 1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test. 2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended use. 3. For conducted measurements (Output Power, Emission Bandwidth, Power Spectral Density, Spurious Emissions), the antenna of EUT is connected to the test equipment via temporary antenna connector, the antenna connector is soldered on the antenna port of EUT, and the temporary antenna connector is listed in the Test Instruments. Page 8 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 5. Facilities and Accreditations 5.1. Facilities The test facility is recognized, certified, or accredited by the following organizations: ● FCC - Registration No.: 645098 Shenzhen Tongce Testing Lab The 3m Semi-anechoic chamber has been registered and fully described in a report with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. ● IC - Registration No.: 10668A-1 The 3m Semi-anechoic chamber of Shenzhen TCT Testing Technology Co., Ltd. has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing 5.2. Location Shenzhen Tongce Testing Lab Address: 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China TEL: +86-755-27673339 5.3. Measurement Uncertainty The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item MU Conducted Emission ±2.56dB RF power, conducted ±0.12dB Spurious emissions, conducted ±0.11dB All emissions, radiated(<1G) ±3.92dB All emissions, radiated(>1G) ±4.28dB Temperature ±0.1°C Humidity ±1.0% Page 9 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6. Test Results and Measurement Data 6.1. Antenna requirement Standard requirement: FCC Part15 C Section 15.203 /247(c) 15.203 requirement: An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. E.U.T Antenna: The directional gain of the antenna less than 6 dBi, please refer to the below antenna photo. WiFi/BT ANT LTE DIV ANT Page 10 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.2. Conducted Emission 6.2.1. Test Specification Test Requirement: FCC Part15 C Section 15.207 Test Method: ANSI C63.10:2013 Frequency Range: 150 kHz to 30 MHz Receiver setup: RBW=9 kHz, VBW=30 kHz, Sweep time=auto Limits: Frequency range (MHz) 0.15-0.5 0.5-5 5-30 Limit (dBuV) Quasi-peak Average 66 to 56* 56 to 46* 56 46 60 50 Test Setup: Test Mode: Tx Mode Test Procedure: 1. The E.U.T and simulators are connected to the main power through a line impedance stabilization network (L.I.S.N.). This provides a 50ohm/50uH coupling impedance for the measuring equipment. 2. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please refer to the block diagram of the test setup and photographs). 3. Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed according to ANSI C63.10: 2013 on conducted measurement. Test Result: PASS Page 11 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.2.2. Test Instruments Conducted Emission Shielding Room Test Site (843) Equipment Manufacturer Model Serial Number Calibration Due Test Receiver R&S ESPI 101401 Jun. 12, 2018 LISN Schwarzbeck NSLK 8126 8126453 Sep. 27, 2018 Coax cable (9KHz-30MHz) TCT CE-05 N/A Sep. 27, 2018 EMI Test Software Shurple Technology EZ-EMC N/A N/A Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to international system unit (SI). Page 12 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.2.3. Test data Please refer to following diagram for individual Conducted Emission on Line Terminal of the power line Remark: Transd = Cable lose+ PULSE LIMITER factor + ARTIFICIAL MAINS factor; Margin= Limit - Level Page 13 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Conducted Emission on Neutral Terminal of the power line Remark: Transd = Cable lose+ PULSE LIMITER factor + ARTIFICIAL MAINS factor; Margin= Limit - Level Page 14 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.3. Maximum Conducted Output Power 6.3.1. Test Specification Test Requirement: Test Method: FCC Part15 E Section 15.407(a)& Part 2 J Section 2.1046 KDB789033 D02 General UNII Test Procedures New Rules v02 Section E Frequency (MHz) Limit: Band Limit 5150-5250 250mW for client devices 5725-5850 1W Note: For those cases where it is specified that the conducted output power be reduced by the amount in dB that the directional gain of the transmitting antenna exceeds 6 dBi, the output power effective limit shall be calculated as follows in Equation: Pout = PLimit - ( directional gain - 6) Test Setup: Test Mode: Transmitting mode with modulation Test Procedure: 1. The testing follows the Measurement Procedure of KDB789033 D02 General UNII Test Procedures New Rules v02 Section E, 3, a 2. The RF output of EUT was connected to the power meter by RF cable and attenuator. The path loss was compensated to the results for each measurement. 3. Set to the maximum power setting and enable the EUT transmit continuously. 5. Measure the conducted output power and record the results in the test report. Test Result: PASS Remark: Conducted output power= measurement power +10log(1/x) X is duty cycle=1, so 10log(1/1)=0 Conducted output power= measurement power Page 15 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.3.2. Test Instruments RF Test Room Equipment Manufacturer Model Serial Number Calibration Due Spectrum Analyzer Agilent N9020A MY49100060 Sep. 27, 2018 Power Meter Agilent N1911A MY45101557 Sep. 27, 2018 Power Sensor Agilent N1922A MY44124432 Sep. 27, 2018 RF Cable (9KHz-40GHz) TCT RE-03 N/A Sep. 27, 2018 Antenna Connector TCT RFC-03 N/A Sep. 27, 2018 Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to international system unit (SI). Page 16 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.3.3. Test Data Configuration Band I (5150 - 5250 MHz ) Mode Test channel Maximum Conducted Output Power (dBm) FCC Limit (dBm) Result 11a CH36 11.40 24 PASS 11a CH40 10.63 24 PASS 11a CH48 10.20 24 PASS 11n(HT20) CH36 9.46 24 PASS 11n(HT20) CH40 8.53 24 PASS 11n(HT20) CH48 8.14 24 PASS 11n(HT40) CH38 7.34 24 PASS 11n(HT40) CH46 6.70 24 PASS FCC Limit (dBm) Result Configuration Band IV (5725 - 5850 MHz ) Mode Test channel Maximum Conducted Output Power (dBm) 11a CH149 11.42 30 PASS 11a CH157 9.88 30 PASS 11a CH165 9.21 30 PASS 11n(HT20) CH149 9.47 30 PASS 11n(HT20) CH157 7.98 30 PASS 11n(HT20) CH165 7.21 30 PASS 11n(HT40) CH151 7.10 30 PASS 11n(HT40) CH159 6.40 30 PASS Page 17 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.4. 6dB Emission Bandwidth 6.4.1. Test Specification FCC CFR47 Part 15 Section 15.407(e)& Part 2 J Section 2.1049 KDB789033 D02 General UNII Test Procedures New Rules v02 Section C >500kHz Test Requirement: Test Method: Limit: Test Setup: Test Mode: Transmitting mode with modulation Test Procedure: 1. KDB789033 D02 General UNII Test Procedures New Rules v02 Section C 2. Set to the maximum power setting and enable the EUT transmit continuously. 3. Make the measurement with the spectrum analyzer's resolution bandwidth (RBW) = 100 kHz. Set the Video bandwidth (VBW) = 300 kHz. In order to make an accurate measurement. The 6dB bandwidth must be greater than 500 kHz. 4. Measure and record the results in the test report. Test Result: PASS 6.4.2. Test Instruments RF Test Room Equipment Manufacturer Model Serial Number Calibration Due Spectrum Analyzer Agilent N9020A MY49100060 Sep. 27, 2018 RF Cable (9KHz-40GHz) TCT RE-03 N/A Sep. 27, 2018 Antenna Connector TCT RFC-03 N/A Sep. 27, 2018 Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to international system unit (SI). Page 18 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.4.3. Test data Band IV (5725 - 5850 MHz ) Mode Test channel Frequency (MHz) 6 dB Bandwidth (MHz) Limit (MHz) Result 11a 11a 11a 11n(HT20) 11n(HT20) 11n(HT20) 11n(HT40) 11n(HT40) CH149 CH157 CH161 CH149 CH157 CH161 CH151 CH159 5745 5785 5825 5745 5785 5825 5755 5795 15.15 14.25 15.12 14.70 15.93 15.09 36.52 35.83 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 PASS PASS PASS PASS PASS PASS PASS PASS Test plots as follows: Page 19 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Band IV (5725 – 5850 MHz) 802.11a Low Mid High Page 20 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 802.11n(HT20) Low Mid High Page 21 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 802.11n(HT40) Low High Page 22 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.5. 26dB Bandwidth and 99% Occupied Bandwidth 6.5.1. Test Specification 47 CFR Part 15C Section 15.407 (a)& Part 2 J Section 2.1049 KDB789033 D02 General UNII Test Procedures New Rules v02 Section D No restriction limits Test Requirement: Test Method: Limit: Test Setup: Test Mode: Transmitting mode with modulation Test Procedure: 1. KDB789033 D02 General UNII Test Procedures New Rules v02 Section D 2. Set to the maximum power setting and enable the EUT transmit continuously. 3. Make the measurement with the spectrum analyzer's resolution bandwidth (RBW) = 100 kHz. Set the Video bandwidth (VBW) = 300 kHz. In order to make an accurate measurement. 4. Measure and record the results in the test report. Test Result: PASS 6.5.2. Test Instruments RF Test Room Equipment Manufacturer Model Serial Number Calibration Due Spectrum Analyzer Agilent N9020A MY49100060 Sep. 27, 2018 RF Cable (9KHz-26.5GHz) TCT RE-06 N/A Sep. 27, 2018 Antenna Connector TCT RFC-01 N/A Sep. 27, 2018 Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to international system unit (SI). Page 23 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.5.3. Test data Band I Mode Test channel 11a 11a 11a 11n(HT20) 11n(HT20) 11n(HT20) 11n(HT40) 11n(HT40) CH36 CH44 CH48 CH36 CH44 CH48 CH38 CH46 Frequency (MHz) 5180 5220 5240 5180 5220 5240 5190 5230 26 dB Bandwidth 99% Bandwidth (MHz) (MHz) 19.47 16.48 19.71 16.51 20.88 16.57 19.62 17.53 19.74 17.65 19.71 17.62 40.26 36.38 41.04 36.38 Test plots as follows: Page 24 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Band I (5150 – 5250 MHz) 802.11a Low Mid High Page 25 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 802.11n(HT20) Low Mid High Page 26 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 802.11n(HT40) Low High Page 27 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.6. Power Spectral Density 6.6.1. Test Specification Test Requirement: Test Method: Limit: FCC Part15 E Section 15.407 (a) KDB789033 D02 General UNII Test Procedures New Rules v02 Section F ≤11.00dBm/MHz for Band I 5150MHz-5250MHz ≤30.00dBm/500KHz for Band IV 5725MHz-5850MHz The e.i.r.p spectral density for Band I 5150MHz – 5250 MHz should not exceed 10dBm/MHz Note: For those cases where it is specified that the conducted output power be reduced by the amount in dB that the directional gain of the transmitting antenna exceeds 6 dBi, the PSD effective limit shall be calculated as follows in Equation: PSDout = PSDLimit - ( directional gain - 6) Test Setup: Test Mode: Transmitting mode with modulation Test Procedure: 1. Set the spectrum analyzer or EMI receiver span to view the entire emission bandwidth. 1. Set RBW = 500 kHz/1 MHz, VBW ≥ 3*RBW, Sweep time = Auto, Detector = RMS. 2. Allow the sweeps to continue until the trace stabilizes. 3. Use the peak marker function to determine the maximum amplitude level. 4. The E.I.R.P spectral density used radiated test method. At a test site that has been validated using the procedures of ANSI C63.4 or the latest CISPR 16-1-4 for measurements above 1 GHz, so as to simulate a near free-space environment. Test Result: PASS Page 28 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.6.2. Test Instruments RF Test Room Equipment Manufacturer Model Serial Number Calibration Due Spectrum Analyzer Agilent N9020A MY49100060 Sep. 27, 2018 Spectrum Analyzer ROHDE&SCH WARZ FSP40 100056 Sep. 27, 2018 RF Cable (9KHz-40GHz) TCT RE-03 N/A Sep. 27, 2018 Antenna Connector TCT RFC-03 N/A Sep. 27, 2018 Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to international system unit (SI). Page 29 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.6.3. Test data Configuration Band I (5150 - 5250 MHz ) Mode Test channel 11a CH36 Power Spectral Density 0.99 11a CH44 11a Limit (dBm/MHz) Result 11 PASS 0.58 11 PASS CH48 0.22 11 PASS 11n(HT20) CH36 -0.75 11 PASS 11n(HT20) CH44 -1.52 11 PASS 11n(HT20) CH48 -2.42 11 PASS 11n(HT40) CH38 -6.59 11 PASS 11n(HT40) CH46 -7.27 11 PASS Limit (dBm/MHz) Result 30 PASS Configuration Band IV (5725 - 5850 MHz ) Mode Test channel 11a CH149 Power Spectral Density 0.14 11a CH157 -1.19 30 PASS 11a CH161 -1.53 30 PASS 11n(HT20) CH149 -1.76 30 PASS 11n(HT20) CH157 -2.88 30 PASS 11n(HT20) CH161 -3.62 30 PASS 11n(HT40) CH151 -8.10 30 PASS 11n(HT40) CH159 -9.04 30 PASS Test plots as follows: Page 30 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Band I (5150 – 5250 MHz) 802.11a Low Mid High Page 31 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 802.11n(HT20) Low Mid High Page 32 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 802.11n(HT40) Low High Page 33 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Band IV (5725 – 5850 MHz) 802.11a Low Mid High Page 34 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 802.11n(HT20) Low Mid High Page 35 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 802.11n(HT40) Low High Page 36 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.7. Band edge 6.7.1. Test Specification Test Requirement: FCC CFR47 Part 15E Section 15.407 Test Method: ANSI C63.10 2013 For band I&II&III: E[dBμV/m] = EIRP[dBm] + 95.2=68.2 dBμV/m, for EIRP(dBm)= -27dBm Limit: For band IV(5715-5725MHz&5850-5860MHz): E[dBμV/m] = EIRP[dBm] + 95.2=78.2 dBμV/m, for EIRP(dBm)= -17dBm; For band IV(other un-restricted band):E[dBμV/m] = EIRP[dBm] + 95.2=68.2 dBμV/m, for EIRP(dBm)= -27dBm Test Setup: Test Mode: Transmitting mode with modulation Test Procedure: 1. The EUT was placed on the top of a rotating table 1.5 meters above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation. 2. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. 3. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. 4. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rotatable was turned from 0 degrees to 360 degrees to find the maximum reading. 5. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. 6. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasipeak or average method as specified and then Page 37 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 reported in a data sheet. Test Result: PASS Page 38 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.7.2. Test Instruments Radiated Emission Test Site (966) Name of Equipment Manufacturer Model Serial Number Calibration Due Test Receiver ROHDE&SCHW ARZ ESVD 100008 Sep. 27, 2018 Spectrum Analyzer ROHDE&SCHW ARZ FSQ 200061 Sep. 27, 2018 Spectrum Analyzer ROHDE&SCHW ARZ FSP40 100056 Sep. 27, 2018 Spectrum Analyzer Agilent N9020A MY49100060 Sep. 27, 2018 Pre-amplifier EM Electronics Corporation CO.,LTD EM30265 07032613 Sep. 27, 2018 Pre-amplifier HP 8447D 2727A05017 Sep. 27, 2018 Loop antenna ZHINAN ZN30900A 12024 Sep. 27, 2018 Broadband Antenna Schwarzbeck VULB9163 340 Sep. 27, 2018 Horn Antenna Schwarzbeck BBHA 9120D 631 Sep. 27, 2018 Horn Antenna Schwarzbeck BBH 9170 582 Jun. 07, 2018 Coax cable (9KHz-1GHz) TCT RE-low-01 N/A Sep. 27, 2018 Coax cable (9KHz-40GHz) TCT RE-high-02 N/A Sep. 27, 2018 Coax cable (9KHz-1GHz) TCT RE-low-03 N/A Sep. 27, 2018 Coax cable (9KHz-40GHz) TCT RE-high-04 N/A Sep. 27, 2018 Antenna Mast Keleto CC-A-4M N/A N/A EMI Test Software Shurple Technology EZ-EMC N/A N/A Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to international system unit (SI). Page 39 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.7.3. Test Data Bandwidth: 20MHz Band I for Band edge emission Worst mode: 802.11a Test channel: Low Frequency (MHz) Read Level (dBuV) Antenna Factor (dB) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Detector 5150.00 16.25 31.70 9.79 0.00 57.74 68.20 -10.46 Horizontal Peak 5350.00 12.77 31.40 10.06 0.00 54.23 68.20 -13.97 Horizontal Peak 5150.00 17.48 31.70 9.79 0.00 58.97 68.20 -9.23 Vertical Peak 5350.00 13.89 31.40 10.06 0.00 55.35 68.20 -12.85 Vertical Peak 5150.00 7.21 31.70 9.79 0.00 48.70 54.00 -5.30 Horizontal Average 5350.00 5.63 31.40 10.06 0.00 47.09 54.00 -6.91 Horizontal Average 5150.00 8.36 31.70 9.79 0.00 49.85 54.00 -4.15 Vertical Average 5350.00 6.58 31.40 10.06 0.00 48.04 54.00 -5.96 Vertical Average Bandwidth: 20MHz Band IV for Band edge emission Worst mode: 802.11a Test channel: Low Frequency (MHz) Read Level (dBuV) Antenna Factor (dB) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Detector 5725.00 17.86 31.73 10.47 0.00 60.06 68.20 -8.14 Horizontal Peak 5850.00 15.65 32.20 10.61 0.00 58.46 68.20 -9.74 Horizontal Peak 5725.00 17.63 31.73 10.47 0.00 59.83 68.20 -8.37 Vertical Peak 5850.00 15.71 32.20 10.61 0.00 58.52 68.20 -9.68 Vertical Peak 5725.00 8.67 31.73 10.47 0.00 50.87 54.00 -3.13 Horizontal Average 5850.00 5.48 32.20 10.61 0.00 48.29 54.00 -5.71 Horizontal Average 5725.00 8.55 31.73 10.47 0.00 50.75 54.00 -3.25 Vertical Average 5850.00 6.06 32.20 10.61 0.00 48.87 54.00 -5.13 Vertical Average Page 40 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Bandwidth: 20MHz Band I for Band edge emission Worst mode: 802.11a Test channel: High Frequency (MHz) Read Level (dBuV) Antenna Factor (dB) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Detector 5150.00 12.67 31.70 9.79 0.00 54.16 68.20 -14.04 Horizontal Peak 5350.00 16.17 31.40 10.06 0.00 57.63 68.20 -10.57 Horizontal Peak 5150.00 12.53 31.70 9.79 0.00 54.02 68.20 -14.18 Vertical Peak 5350.00 17.15 31.40 10.06 0.00 58.61 68.20 -9.59 Vertical Peak 5150.00 5.42 31.70 9.79 0.00 46.91 54.00 -7.09 Horizontal Average 5350.00 8.63 31.40 10.06 0.00 50.09 54.00 -3.91 Horizontal Average 5150.00 6.36 31.70 9.79 0.00 47.85 54.00 -6.15 Vertical Average 5350.00 8.58 31.40 10.06 0.00 50.04 54.00 -3.96 Vertical Average Bandwidth: 20MHz Band IV for Band edge emission Worst mode: 802.11a Test channel: High Frequency (MHz) Read Level (dBuV) Antenna Factor (dB) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Detector 5725.00 12.46 31.73 10.47 0.00 54.66 68.20 -13.54 Horizontal Peak 5850.00 16.75 32.20 10.61 0.00 59.56 68.20 -8.64 Horizontal Peak 5725.00 13.01 31.73 10.47 0.00 55.21 68.20 -12.99 Vertical Peak 5850.00 17.21 32.20 10.61 0.00 60.02 68.20 -8.18 Vertical Peak 5725.00 5.42 31.73 10.47 0.00 47.62 54.00 -6.38 Horizontal Average 5850.00 8.01 32.20 10.61 0.00 50.82 54.00 -3.18 Horizontal Average 5725.00 5.69 31.73 10.47 0.00 47.89 54.00 -6.11 Vertical Average 5850.00 7.59 32.20 10.61 0.00 50.40 54.00 -3.60 Vertical Average Page 41 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Bandwidth: 20MHz Band I for Band edge emission Worst mode: 802.11n Test channel: Low Frequency (MHz) Read Level (dBuV) Antenna Factor (dB) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Detector 5150.00 15.36 31.70 9.79 0.00 56.85 68.20 -11.35 Horizontal Peak 5350.00 12.12 31.40 10.06 0.00 53.58 68.20 -14.62 Horizontal Peak 5150.00 16.28 31.70 9.79 0.00 57.77 68.20 -10.43 Vertical Peak 5350.00 11.72 31.40 10.06 0.00 53.18 68.20 -15.02 Vertical Peak 5150.00 6.51 31.70 9.79 0.00 48.00 54.00 -6.00 Horizontal Average 5350.00 5.32 31.40 10.06 0.00 46.78 54.00 -7.22 Horizontal Average 5150.00 6.85 31.70 9.79 0.00 48.34 54.00 -5.66 Vertical Average 5350.00 5.46 31.40 10.06 0.00 46.92 54.00 -7.08 Vertical Average Bandwidth: 20MHz Band IV for Band edge emission Worst mode: 802.11n Test channel: Low Frequency (MHz) Read Level (dBuV) Antenna Factor (dB) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Detector 5725.00 17.57 31.73 10.47 0.00 59.77 68.20 -8.43 Horizontal Peak 5850.00 15.35 32.20 10.61 0.00 58.16 68.20 -10.04 Horizontal Peak 5725.00 17.23 31.73 10.47 0.00 59.43 68.20 -8.77 Vertical Peak 5850.00 15.21 32.20 10.61 0.00 58.02 68.20 -10.18 Vertical Peak 5725.00 8.37 31.73 10.47 0.00 50.57 54.00 -3.43 Horizontal Average 5850.00 5.37 32.20 10.61 0.00 48.18 54.00 -5.82 Horizontal Average 5725.00 8.25 31.73 10.47 0.00 50.45 54.00 -3.55 Vertical Average 5850.00 5.76 32.20 10.61 0.00 48.57 54.00 -5.43 Vertical Average Page 42 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Bandwidth: 20MHz Band I for Band edge emission Worst mode: 802.11n Test channel: High Frequency (MHz) Read Level (dBuV) Antenna Factor (dB) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Detector 5150.00 12.43 31.70 9.79 0.00 53.92 68.20 -14.28 Horizontal Peak 5350.00 15.77 31.40 10.06 0.00 57.23 68.20 -10.97 Horizontal Peak 5150.00 12.08 31.70 9.79 0.00 53.57 68.20 -14.63 Vertical Peak 5350.00 16.44 31.40 10.06 0.00 57.90 68.20 -10.30 Vertical Peak 5150.00 5.97 31.70 9.79 0.00 47.46 54.00 -6.54 Horizontal Average 5350.00 7.63 31.40 10.06 0.00 49.09 54.00 -4.91 Horizontal Average 5150.00 5.33 31.70 9.79 0.00 46.82 54.00 -7.18 Vertical Average 5350.00 8.28 31.40 10.06 0.00 49.74 54.00 -4.26 Vertical Average Bandwidth: 20MHz Band IV for Band edge emission Worst mode: 802.11n Test channel: High Frequency (MHz) Read Level (dBuV) Antenna Factor (dB) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Detector 5725.00 12.23 31.73 10.47 0.00 54.43 68.20 -13.77 Horizontal Peak 5850.00 16.57 32.20 10.61 0.00 59.38 68.20 -8.82 Horizontal Peak 5725.00 12.46 31.73 10.47 0.00 54.66 68.20 -13.54 Vertical Peak 5850.00 16.35 32.20 10.61 0.00 59.16 68.20 -9.04 Vertical Peak 5725.00 5.41 31.73 10.47 0.00 47.61 54.00 -6.39 Horizontal Average 5850.00 7.81 32.20 10.61 0.00 50.62 54.00 -3.38 Horizontal Average 5725.00 5.64 31.73 10.47 0.00 47.84 54.00 -6.16 Vertical Average 5850.00 7.43 32.20 10.61 0.00 50.24 54.00 -3.76 Vertical Average Page 43 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Bandwidth: 40MHz Band I for Band edge emission Worst mode: 802.11n Test channel: Low Frequency (MHz) Read Level (dBuV) Antenna Factor (dB) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Detector 5150.00 15.75 31.70 9.79 0.00 57.24 68.20 -10.96 Horizontal Peak 5350.00 12.65 31.40 10.06 0.00 54.11 68.20 -14.09 Horizontal Peak 5150.00 17.26 31.70 9.79 0.00 58.75 68.20 -9.45 Vertical Peak 5350.00 13.25 31.40 10.06 0.00 54.71 68.20 -13.49 Vertical Peak 5150.00 6.85 31.70 9.79 0.00 48.34 54.00 -5.66 Horizontal Average 5350.00 5.46 31.40 10.06 0.00 46.92 54.00 -7.08 Horizontal Average 5150.00 7.98 31.70 9.79 0.00 49.47 54.00 -4.53 Vertical Average 5350.00 6.46 31.40 10.06 0.00 47.92 54.00 -6.08 Vertical Average Bandwidth: 40MHz Band IV for Band edge emission Worst mode: 802.11n Test channel: Low Frequency (MHz) Read Level (dBuV) Antenna Factor (dB) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Detector 5725.00 17.45 31.73 10.47 0.00 59.65 68.20 -8.55 Horizontal Peak 5850.00 15.23 32.20 10.61 0.00 58.04 68.20 -10.16 Horizontal Peak 5725.00 17.57 31.73 10.47 0.00 59.77 68.20 -8.43 Vertical Peak 5850.00 15.27 32.20 10.61 0.00 58.08 68.20 -10.12 Vertical Peak 5725.00 8.24 31.73 10.47 0.00 50.44 54.00 -3.56 Horizontal Average 5850.00 5.38 32.20 10.61 0.00 48.19 54.00 -5.81 Horizontal Average 5725.00 8.35 31.73 10.47 0.00 50.55 54.00 -3.45 Vertical Average 5850.00 5.86 32.20 10.61 0.00 48.67 54.00 -5.33 Vertical Average Page 44 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Bandwidth: 40MHz Band I for Band edge emission Worst mode: 802.11n Test channel: High Frequency (MHz) Read Level (dBuV) Antenna Factor (dB) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Detector 5150.00 12.53 31.70 9.79 0.00 54.02 68.20 -14.18 Horizontal Peak 5350.00 16.24 31.40 10.06 0.00 57.70 68.20 -10.50 Horizontal Peak 5150.00 12.59 31.70 9.79 0.00 54.08 68.20 -14.12 Vertical Peak 5350.00 16.88 31.40 10.06 0.00 58.34 68.20 -9.86 Vertical Peak 5150.00 5.84 31.70 9.79 0.00 47.33 54.00 -6.67 Horizontal Average 5350.00 8.23 31.40 10.06 0.00 49.69 54.00 -4.31 Horizontal Average 5150.00 6.46 31.70 9.79 0.00 47.95 54.00 -6.05 Vertical Average 5350.00 8.51 31.40 10.06 0.00 49.97 54.00 -4.03 Vertical Average Bandwidth: 40MHz Band IV for Band edge emission Worst mode: 802.11n Test channel: High Frequency (MHz) Read Level (dBuV) Antenna Factor (dB) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Detector 5725.00 12.39 31.73 10.47 0.00 54.59 68.20 -13.61 Horizontal Peak 5850.00 16.51 32.20 10.61 0.00 59.32 68.20 -8.88 Horizontal Peak 5725.00 12.71 31.73 10.47 0.00 54.91 68.20 -13.29 Vertical Peak 5850.00 17.04 32.20 10.61 0.00 59.85 68.20 -8.35 Vertical Peak 5725.00 5.45 31.73 10.47 0.00 47.65 54.00 -6.35 Horizontal Average 5850.00 7.82 32.20 10.61 0.00 50.63 54.00 -3.37 Horizontal Average 5725.00 5.39 31.73 10.47 0.00 47.59 54.00 -6.41 Vertical Average 5850.00 7.44 32.20 10.61 0.00 50.25 54.00 -3.75 Vertical Average Page 45 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.8. Spurious Emission 6.8.1.1. Test Specification Test Requirement: FCC CFR47 Part 15 Section 15.407 & 15.209 & 15.205 Test Method: KDB 789033 D02 v01r04 Frequency Range: 9kHz to 40GHz Measurement Distance: 3m Antenna Polarization: Horizontal & Vertical Operation mode: Transmitting mode with modulation Receiver Setup: Frequency 9kHz- 150kHz 150kHz30MHz 30MHz-1GHz Above 1GHz Detector Quasi-peak Quasi-peak RBW 200Hz 9kHz VBW 1kHz 30kHz Remark Quasi-peak Value Quasi-peak Value Quasi-peak Peak Peak 120KHz 1MHz 1MHz 300KHz 3MHz 10Hz Quasi-peak Value Peak Value Average Value Unwanted spurious emissions fallen in restricted bands per FCC Part15.205 shall comply with the general field strength limits set forth in § 15.209 as below table, Frequency Limit: 0.009-0.490 0.490-1.705 1.705-30 30-88 88-216 216-960 Above 960 Frequency Above 1G Field Strength (microvolts/meter) 2400/F(KHz) 24000/F(KHz) 30 100 150 200 500 Measurement Distance (meters) 300 30 30 Limit (dBuV/m @3m) 74.0 54.0 Detector Peak Average For radiated emissions below 30MHz Test setup: Page 46 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 30MHz to 1GHz Above 1GHz Test Procedure: Test results: 1. The EUT was placed on the top of a rotating table 0.8/1.5 meters above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation. 2. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. 3. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. 4. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rotatable was turned from 0 degrees to 360 degrees to find the maximum reading. 5. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. 6. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet. PASS Page 47 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.8.2. Test Data Please refer to following diagram for individual Below 1GHz Remark: 1. Transd = Cable lose + Antenna factor - Pre-amplifier; Margin = Limit – Level 2. The low frequency, which started from 9KHz~30MHz, was pre-scanned and the result which was 20dB lower than the limit line per 15.31(o) was not reported 3. The 802.11a,802.11n,802.11ac Test mode, found that 802.11a and band 1 mode for low channel was the worst mode, and the report showed only the test results of the worst mode. Page 48 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Above 1GHz Band I for Low Bandwidth: Frequency (MHz) 3143.98 6331.33 9562.85 11140.85 2097.51 4299.89 8083.96 11197.71 Read Level (dBuV) 33.84 31.49 34.34 31.77 33.19 34.05 33.02 32.22 20MHz Antenna Factor (dB/m) 28.80 33.16 39.05 40.30 26.69 30.20 37.02 40.30 Cable Loss (dB) 7.65 11.00 13.73 13.51 6.35 9.03 12.50 13.49 Worst mode: Preamp Factor (dB) 38.21 35.30 35.19 33.52 37.32 37.61 34.54 33.37 Level (dBuV/m) Limit Line (dBuV/m) 32.08 40.35 51.93 52.06 28.91 35.67 48.00 52.64 68.20 68.20 68.20 74.00 68.20 74.00 74.00 74.00 802.11a Margin Limit (dB) -36.12 -27.85 -16.27 -21.94 -39.29 -38.33 -26.00 -21.36 Polarization Test value Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Peak Peak Peak Peak Peak Peak Peak Peak Band I for Mid Bandwidth: 20MHz Worst mode: Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) 1286.61 3057.17 7081.70 11140.85 1638.59 3644.18 6594.52 11312.31 35.92 34.71 31.97 32.06 35.20 34.80 32.38 32.53 26.21 28.72 35.55 40.30 25.02 29.30 34.19 40.30 4.81 7.55 11.85 13.51 5.65 8.32 11.35 13.45 36.52 38.22 34.91 33.52 36.80 38.26 35.36 33.81 30.42 32.76 44.46 52.35 29.07 34.16 42.56 52.47 68.20 68.20 68.20 74.00 68.20 74.00 68.20 74.00 802.11a Margin Limit (dB) -43.58 -41.24 -29.54 -21.65 -44.93 -39.84 -31.44 -21.53 Polarization Test value Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Peak Peak Peak Peak Peak Peak Peak Peak Band I for High Bandwidth: Frequency (MHz) Read Level (dBuV) 20MHz Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Worst mode: Level (dBuV/m) Limit Line (dBuV/m) 802.11a Margin Limit (dB) -46.08 -34.90 -26.44 -22.13 -44.70 -39.79 -24.55 -16.36 Polarization 1672.30 33.96 25.12 5.71 36.87 27.92 74.00 Horizontal 3498.74 34.61 28.99 8.11 38.41 33.30 68.20 Horizontal 6662.01 31.38 34.20 11.43 35.25 41.76 68.20 Horizontal 10888.51 32.04 40.56 13.58 34.31 51.87 74.00 Horizontal 1323.14 34.80 26.13 4.87 36.50 29.30 74.00 Vertical 3662.78 34.83 29.30 8.34 38.26 34.21 74.00 Vertical 7063.69 31.19 35.49 11.85 34.88 43.65 68.20 Vertical 10587.85 31.66 39.96 13.59 33.37 51.84 68.20 Vertical Remark: 1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor 2. The emission levels of other frequencies are very lower than the limit and not show in test report. 3. Measuring frequencies from 1 GHz to 40GHz of highest fundamental frequency. Test value Peak Peak Peak Peak Peak Peak Peak Peak Page 49 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Band I for Low Bandwidth: 20MHz Worst mode: Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) 1750.70 3719.15 6267.19 8792.37 1244.73 1851.54 4170.53 8145.93 31.65 32.77 30.78 31.60 33.80 32.29 31.83 31.28 25.30 29.36 33.03 37.72 26.25 25.35 29.97 36.86 5.86 8.41 11.00 13.09 4.74 6.04 8.92 12.64 37.04 38.25 35.30 34.29 36.55 37.18 37.72 34.54 25.77 32.29 39.51 48.12 28.24 26.50 33.00 46.24 68.20 74.00 68.20 68.20 68.20 68.20 74.00 74.00 802.11n Margin Limit (dB) -42.43 -41.71 -28.69 -20.08 -39.96 -41.70 -41.00 -27.76 Polarization Test value Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Peak Peak Peak Peak Peak Peak Peak Peak Band I for Mid Bandwidth: Frequency (MHz) 1750.70 3184.25 4594.10 8637.08 1768.62 3913.39 6235.36 8681.17 Read Level (dBuV) 33.82 32.27 31.83 31.61 33.70 33.43 31.92 31.75 20MHz Antenna Factor (dB/m) 25.30 28.80 30.89 37.52 25.34 29.70 32.97 37.79 Cable Loss (dB) 5.86 7.70 9.45 12.93 5.90 8.66 11.01 12.98 Worst mode: Preamp Factor (dB) 37.04 38.20 37.24 34.48 37.07 38.16 35.29 34.42 Level (dBuV/m) Limit Line (dBuV/m) 27.94 30.57 34.93 47.58 27.87 33.63 40.61 48.10 68.20 68.20 74.00 68.20 68.20 74.00 68.20 68.20 802.11n Margin Limit (dB) -40.26 -37.63 -39.07 -20.62 -40.33 -40.37 -27.59 -20.10 Polarization Test value Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Peak Peak Peak Peak Peak Peak Peak Peak Band I for High Bandwidth: Frequency (MHz) Read Level (dBuV) 20MHz Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Worst mode: Level (dBuV/m) Limit Line (dBuV/m) 802.11n Margin Limit (dB) -44.57 -41.11 -26.44 -28.27 -37.70 -38.06 -32.00 -21.32 Polarization 2883.32 31.89 28.43 7.42 38.31 29.43 74.00 Horizontal 3805.33 33.00 29.61 8.51 38.23 32.89 74.00 Horizontal 6662.01 31.38 34.20 11.43 35.25 41.76 68.20 Horizontal 8334.70 30.79 36.47 12.82 34.35 45.73 74.00 Horizontal 2157.07 34.27 27.16 6.40 37.33 30.50 68.20 Vertical 3428.21 32.22 28.43 8.00 38.51 30.14 68.20 Vertical 5462.30 30.79 31.75 10.17 36.51 36.20 68.20 Vertical 8002.06 32.01 37.10 12.30 34.53 46.88 68.20 Vertical Remark: 1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor 2. The emission levels of other frequencies are very lower than the limit and not show in test report. 3. Measuring frequencies from 1 GHz to 40GHz of highest fundamental frequency. Test value Peak Peak Peak Peak Peak Peak Peak Peak Page 50 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Band I for Low Bandwidth: 40MHz Worst mode: Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) 1235.26 2905.42 4321.84 7741.59 1573.19 3662.78 7099.75 9204.60 33.97 32.00 31.66 30.06 33.61 33.39 30.42 32.67 26.26 28.51 30.27 36.10 25.14 29.30 35.60 38.63 4.72 7.43 9.06 13.10 5.49 8.34 11.85 13.50 36.55 38.29 37.60 35.04 36.69 38.26 34.93 35.84 28.40 29.65 33.39 44.22 27.55 32.77 42.94 48.96 74.00 68.20 74.00 74.00 74.00 74.00 68.20 68.20 802.11n Margin Limit (dB) -45.60 -38.55 -40.61 -29.78 -46.45 -41.23 -25.26 -19.24 Polarization Test value Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Peak Peak Peak Peak Peak Peak Peak Peak Band I for High Bandwidth: Frequency (MHz) 1251.08 3634.91 5244.30 8166.69 1309.74 2258.20 3747.66 7027.82 Read Level (dBuV) 34.02 32.68 30.46 31.12 33.85 32.37 33.75 32.05 40MHz Antenna Factor (dB/m) 26.25 29.30 31.41 36.80 26.17 27.85 29.44 35.38 Cable Loss (dB) 4.75 8.31 9.90 12.69 4.85 6.54 8.44 11.85 Preamp Factor (dB) 36.54 38.26 36.33 34.55 36.51 37.50 38.24 34.83 Worst mode: Level (dBuV/m) Limit Line (dBuV/m) 28.48 32.03 35.44 46.06 28.36 29.26 33.39 44.45 68.20 74.00 68.20 74.00 74.00 74.00 74.00 68.20 802.11n Margin Limit (dB) -39.72 -41.97 -32.76 -27.94 -45.64 -44.74 -40.61 -23.75 Polarization Test value Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Peak Peak Peak Peak Peak Peak Peak Peak Remark: 1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor 2. The emission levels of other frequencies are very lower than the limit and not show in test report. 3. Measuring frequencies from 1 GHz to 40GHz of highest fundamental frequency. Page 51 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Bandwidth: 20MHz Band IV for Low Worst mode: 802.11a Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Test value 1257.47 3570.71 7451.57 11254.86 1545.41 3120.06 5574.67 10833.22 35.67 35.05 32.25 31.47 34.40 35.32 32.70 32.72 26.24 29.21 36.20 40.30 25.38 28.80 31.83 40.37 4.76 8.22 12.24 13.47 5.41 7.62 10.25 13.58 36.54 38.31 34.86 33.58 36.65 38.21 35.99 34.51 30.13 34.17 45.83 51.66 28.54 33.53 38.79 52.16 68.20 68.20 74.00 74.00 74.00 68.20 68.20 74.00 -38.07 -34.03 -28.17 -22.34 -45.46 -34.67 -29.41 -21.84 Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Peak Peak Peak Peak Peak Peak Peak Peak Bandwidth: 20MHz Band IV for Mid Worst mode: 802.11a Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) 1442.76 3049.39 5217.66 11226.25 1270.33 3184.25 7604.87 10833.22 33.60 33.96 32.29 31.69 35.53 35.84 31.45 32.34 25.86 28.70 31.46 40.30 26.23 28.80 36.20 40.37 5.12 7.54 9.86 13.48 4.78 7.70 12.73 13.58 36.52 38.22 36.25 33.47 36.53 38.20 34.98 34.51 28.06 31.98 37.36 52.00 30.01 34.14 45.40 51.78 74.00 68.20 68.20 74.00 68.20 68.20 74.00 74.00 -45.94 -36.22 -30.84 -22.00 -38.19 -34.06 -28.60 -22.22 Bandwidth: 20MHz Band IV for High Worst mode: Polarization Test value Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Peak Peak Peak Peak Peak Peak Peak Peak 802.11a Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Margin Limit (dB) Polarization Test value 1553.29 3903.44 5546.36 11169.24 1244.73 3184.25 6235.36 11226.25 33.97 34.19 32.09 32.00 34.88 34.62 32.46 33.06 25.31 29.70 31.85 40.30 26.25 28.80 32.97 40.30 5.44 8.64 10.23 13.50 4.74 7.70 11.01 13.48 36.66 38.17 36.12 33.44 36.55 38.20 35.29 33.47 28.06 34.36 38.05 52.36 29.32 32.92 41.15 53.37 74.00 74.00 68.20 74.00 68.20 68.20 68.20 74.00 -45.94 -39.64 -30.15 -21.64 -38.88 -35.28 -27.05 -20.63 Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Peak Peak Peak Peak Peak Peak Peak Peak Remark: 1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor 2. The emission levels of other frequencies are very lower than the limit and not show in test report. 3. Measuring frequencies from 1 GHz to 40GHz of highest fundamental frequency. Page 52 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Bandwidth: 20MHz Band IV for Low Worst mode: Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) 1289.89 3543.55 5164.81 8355.94 1646.95 3766.79 7045.74 8770.01 33.95 33.25 31.73 31.35 32.34 32.63 30.75 31.26 26.21 29.13 31.64 36.51 25.04 29.50 35.44 37.76 4.81 8.18 9.80 12.83 5.66 8.46 11.85 13.07 36.52 38.35 36.24 34.32 36.82 38.24 34.86 34.32 28.45 32.21 36.93 46.37 26.22 32.35 43.18 47.77 68.20 68.20 68.20 74.00 68.20 74.00 68.20 68.20 Bandwidth: Frequency (MHz) 1472.44 3543.55 4895.97 9298.80 1286.61 3308.19 4996.69 8527.85 Read Level (dBuV) 31.70 33.17 30.87 32.43 34.07 32.25 30.73 31.84 20MHz Antenna Factor (dB/m) 25.83 29.13 31.41 39.19 26.21 28.20 31.50 37.01 Bandwidth: Frequency (MHz) Read Level (dBuV) Cable Loss (dB) 5.21 8.18 9.60 13.59 4.81 7.85 9.67 12.88 Antenna Factor (dB/m) Cable Loss (dB) Margin Limit (dB) -39.75 -35.99 -31.27 -27.63 -41.98 -41.65 -25.02 -20.43 Band IV for Mid Worst mode: Preamp Factor (dB) 36.55 38.35 36.69 35.58 36.52 38.39 36.41 34.43 20MHz 802.11n Level (dBuV/m) Limit Line (dBuV/m) 26.19 32.13 35.19 49.63 28.57 29.91 35.49 47.30 74.00 68.20 74.00 68.20 68.20 68.20 74.00 68.20 Level (dBuV/m) Limit Line (dBuV/m) Test value Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Peak Peak Peak Peak Peak Peak Peak Peak 802.11n Margin Limit (dB) -47.81 -36.07 -38.81 -18.57 -39.63 -38.29 -38.51 -20.90 Band IV for High Worst mode: Preamp Factor (dB) Polarization Polarization Test value Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Peak Peak Peak Peak Peak Peak Peak Peak 802.11n Margin Limit (dB) -45.88 -43.70 -41.25 -20.26 -45.82 -42.22 -29.09 -20.77 Polarization 1213.44 33.71 26.29 4.68 36.56 28.12 74.00 Horizontal 3266.35 32.42 28.40 7.80 38.32 30.30 74.00 Horizontal 4191.82 31.50 29.99 8.93 37.67 32.75 74.00 Horizontal 8593.22 32.29 37.27 12.89 34.51 47.94 68.20 Horizontal 1228.98 33.75 26.27 4.71 36.55 28.18 74.00 Vertical 3662.78 32.40 29.30 8.34 38.26 31.78 74.00 Vertical 6315.23 30.28 33.13 11.00 35.30 39.11 68.20 Vertical 8770.01 30.92 37.76 13.07 34.32 47.43 68.20 Vertical Remark: 1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor 2. The emission levels of other frequencies are very lower than the limit and not show in test report. 3. Measuring frequencies from 1 GHz to 40GHz of highest fundamental frequency. Test value Peak Peak Peak Peak Peak Peak Peak Peak Page 53 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Bandwidth: 40MHz Band IV for Low Worst mode: Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) 1257.47 3258.04 6140.85 8549.59 1685.12 3308.19 5588.88 9204.60 34.27 32.48 30.61 31.43 33.10 32.50 30.61 32.31 26.24 28.45 32.66 37.10 25.16 28.20 31.81 38.63 4.76 7.79 10.91 12.88 5.74 7.85 10.26 13.50 36.54 38.30 35.34 34.45 36.90 38.39 35.92 35.84 28.73 30.42 38.84 46.96 27.10 30.16 36.76 48.60 68.20 74.00 68.20 68.20 74.00 68.20 68.20 68.20 Bandwidth: Frequency (MHz) 1219.64 2912.82 5806.41 9660.72 1884.83 3498.74 5776.92 7800.94 Read Level (dBuV) 33.62 31.34 30.14 31.13 32.38 33.30 31.92 30.85 40MHz Antenna Factor (dB/m) 26.28 28.51 32.11 39.09 25.31 28.99 31.99 36.11 Cable Loss (dB) 4.69 7.43 10.59 13.71 6.09 8.11 10.55 13.26 802.11n Margin Limit (dB) -39.47 -43.58 -29.36 -21.24 -46.90 -38.04 -31.44 -19.60 Band IV for High Worst mode: Preamp Factor (dB) 36.56 38.29 35.32 35.32 37.21 38.41 35.38 35.07 Level (dBuV/m) Limit Line (dBuV/m) 28.03 28.99 37.52 48.61 26.57 31.99 39.08 45.15 74.00 68.20 68.20 68.20 68.20 68.20 68.20 68.20 Polarization Test value Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Peak Peak Peak Peak Peak Peak Peak Peak 802.11n Margin Limit (dB) -45.97 -39.21 -30.68 -19.59 -41.63 -36.21 -29.12 -23.05 Polarization Test value Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Peak Peak Peak Peak Peak Peak Peak Peak Remark: 1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor 2. The emission levels of other frequencies are very lower than the limit and not show in test report. 3. Measuring frequencies from 1 GHz to 40GHz of highest fundamental frequency. Page 54 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 6.9. Frequency Stability Measurement 6.9.1. Test Specification Test Requirement: FCC Part15 Section 15.407(g) &Part2 J Section 2.1055 Test Method: ANSI C63.10: 2013 The frequency tolerance shall be maintained within the band of operation frequency over a temperature variation of -30 degrees to 50 degrees C at normal supply voltage, and for a variation in the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees C. Limit: Test Setup: Test Procedure: The EUT was placed inside the environmental test chamber and powered by nominal AC/DC voltage. b. Turn the EUT on and couple its output to a spectrum analyzer. c. Turn the EUT off and set the chamber to the highest temperature specified. d. Allow sufficient time (approximately 30 min) for the temperature of the chamber to stabilize. e. Repeat step 2 and 3 with the temperature chamber set to the lowest temperature. f. The test chamber was allowed to stabilize at +20 degree C for a minimum of 30 minutes. The supply voltage was then adjusted on the EUT from 85% to 115% and the frequency record. Test Result: PASS Remark: Pre-scan was performed at Low/ Mid /High channel, the worst case was found. Only the test data of Low channel was shown in this report. Page 55 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Test plots as follows: Band I for 802.11a Low Test Voltage(%) Power(VDC) TEMP(°C) Frequency (MHz) 100% -20 5180 100% -10 5180 100% 5180 100% 10 5180 3.70 100% 20 5180 100% 30 5180 100% 40 5180 100% 50 5180 Freq.Dev (Hz) Deviation (ppm) -19000.00 -19000.00 -20000.00 -19000.00 -19000.00 -19000.00 -19000.00 -19000.00 -3.66795 -3.66795 -3.86100 -3.66795 -3.66795 -3.66795 -3.66795 -3.66795 85% 3.33 25 5180 -20000.00 -3.86100 115% 4.07 25 5180 -19000.00 -3.66795 Freq.Dev (Hz) Deviation (ppm) -20000.00 -20000.00 -20000.00 -21000.00 -21000.00 -21000.00 -21000.00 -21000.00 -3.48129 -3.48129 -3.48129 -3.65535 -3.65535 -3.65535 -3.65535 -3.65535 Band IV for 802.11a Low Test Voltage(%) Power(VDC) TEMP(°C) Frequency (MHz) 100% -20 5745 100% -10 5745 100% 5745 100% 10 5745 3.70 100% 20 5745 100% 30 5745 100% 40 5745 100% 50 5745 85% 3.33 25 5745 -20000.00 -3.48129 115% 4.07 25 5745 -20000.00 -3.48129 Page 56 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Appendix A: Photographs of Test Setup Radiated Emission Page 57 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 CE Page 58 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT180126E010 Appendix B: Photographs of EUT Reference to the test report No.: TRE1801004501. *****END OF REPORT***** Page 59 of 59 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Source Exif Data [exif.tools]:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 2018:02:09 15:46:40Z Creator Tool : Microsoft® Office Word 2007 Modify Date : 2018:02:09 15:46:57+08:00 Metadata Date : 2018:02:09 15:46:57+08:00 Format : application/pdf Creator : Harris Title : CE EMC TEST REPORT Producer : Microsoft® Office Word 2007 Document ID : uuid:aa2ea4c5-48db-4d87-86e7-99864bc194d3 Instance ID : uuid:172de4b8-d709-4d72-94cf-649ae793ad05 Page Count : 59 Language : zh-CN Author : Harris