Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2018-01-17
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2018-01-17
2402-2480 MHzOriginal Equipment2017-04-21
2402-2480 MHzOriginal Equipment2017-04-21

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2017-07-29PDF 68.3 KB
Users Manual_LV Connected Watch LeafletUsers Manual2017-07-29PDF 976.5 KB
Internal photoInternal Photos2018-07-16PDF 720.2 KB
Internal PhotosInternal Photos2017-07-29PDF 720.2 KB
External photoExternal Photos2018-07-16PDF 618.8 KB
External PhotosExternal Photos2017-07-29PDF 642.6 KB
ID label/Location infoID Label/Location Info2018-01-17PDF 104.7 KB
ID Label/Location InfoID Label/Location Info2017-04-21PDF 104.7 KB
Test setup photo_SARTest Setup Photos2018-07-16PDF 236.8 KB
Test Setup Photos_DSSTest Setup Photos2017-07-29PDF 422.9 KB
Test Setup Photos_DTSTest Setup Photos2017-07-29PDF 339.8 KB
Test Setup Photos_SARTest Setup Photos2017-07-29PDF 232.4 KB
Test report-SARRF Exposure Info2018-01-17PDF 857.9 KB
DTS test report_BLETest Report2017-04-21PDF 1.9 MB
DTS test report_WIFITest Report2017-04-21PDF 4.8 MB
Test Report_DSSTest Report2017-04-21PDF 4.2 MB
Test Report_SARRF Exposure Info2017-04-21PDF 1.1 MB
Declaration of authorizationCover Letter(s)2018-01-17PDF 41.8 KB
FCC Class II permissive change letterCover Letter(s)2018-01-17PDF 41 KB
confidentialityCover Letter(s)2018-01-17PDF 48.2 KB
Declaration of authorizationCover Letter(s)2017-04-21PDF 91.3 KB
LT and ST ConfidentialityCover Letter(s)2017-04-21PDF 16.9 KB
WIFI ch 12 -13 Declaration letterCover Letter(s)2017-04-21PDF 29.3 KB
confidentialityCover Letter(s)2017-04-21PDF 51 KB
Block Diagram Metadata onlyBlock DiagramPDF 183.9 KB
Block diagram Metadata onlyBlock DiagramPDF 183.9 KB
Schematics Metadata onlySchematicsPDF 1.6 MB
Operational Description Metadata onlyOperational DescriptionPDF 112.8 KB
Operational description Metadata onlyOperational DescriptionPDF 112.8 KB

Application Information

Application IDB2014h2eTjvE684UtBJlOw==
Final Action Date2018-01-17
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0024554651
ModelQA00
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionLouis Vuitton Connected Watch
Responsible PartyXiaohan Lu, Head of Hardware IoT, xiaohan.lu@louisvuitton.com , +33668415733
Technical ContactWillis Chen, SGS Taiwan Ltd., willis.chen@sgs.com , 886222993279
Non-Technical ContactWillis Chen, SGS Taiwan Ltd., willis.chen@sgs.com , 886222993279
Test FirmRyan Wang, SGS Taiwan Ltd., Ryan-ec.wang@sgs.com , +886-2-2299-3279
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date07/16/2018
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsCIIPC: To add the metal watchband, the SAR testing is performed accordingly to demonstrate RF compliance. . End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements. The highest reported SAR values for body and simultaneous transmission use conditions are 0.09 W/kg (10g), and 0.35 W/kg, respectively. Output power listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filing. SAR has been evaluated at 0 mm. End-users must be informed regarding RF exposure compliance. The highest reported SAR values for body and simultaneous transmission use conditions are 0.093 W/kg, and 0.36 W/kg, respectively.

Applications

Application IDDatePurpose
B2014h2eTjvE684UtBJlOw==2018-01-17Class II permissive change or modification of presently authorized equipment
1kWmOT5Cd+53ncOW727FKQ==2018-01-17Class II permissive change or modification of presently authorized equipment
tYrnqutiSIJyIMASB2tP3w==2017-04-21Original Equipment
bGRJm/Z7NT4t1yeeEgK1KQ==2017-04-21Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.019000015C
2402-2480 MHz0.002115C
2412-2462 MHz0.07715C

Grants

TCB Grant - Application tYrnqutiSIJyIMASB2tP3w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 04/21/2017

Application Dated: 04/20/2017
LOUIS VUITTON MALLETIER
2, rue du Pont Neuf 75001
PARIS,
France
 
Attention: Xiaohan Lu , Head of Hardware IoT

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ALDGQA00
Name of Grantee:  LOUIS VUITTON MALLETIER
Equipment Class: Digital Transmission System
Notes: Louis Vuitton Connected Watch
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0021  
15C 2412.0  -  2462.0 0.077  

Output power listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. End-users must be informed regarding RF exposure compliance. The highest reported SAR values for body and simultaneous transmission use conditions are 0.28 W/kg, and 0.36 W/kg, respectively. This device has a 20 MHz bandwidth mode.

EAS Grant - Application tYrnqutiSIJyIMASB2tP3w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

LOUIS VUITTON MALLETIER
2, rue du Pont Neuf 75001
PARIS,
France
  Date of Grant: 04/21/2017

Application Dated: 04/20/2017
 
Attention: Xiaohan Lu , Head of Hardware IoT

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ALDGQA00
Name of Grantee:  LOUIS VUITTON MALLETIER
Equipment Class: Digital Transmission System
Notes: Louis Vuitton Connected Watch
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0021  
15C 2412.0  -  2462.0 0.077  

Output power listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. End-users must be informed regarding RF exposure compliance. The highest reported SAR values for body and simultaneous transmission use conditions are 0.28 W/kg, and 0.36 W/kg, respectively. This device has a 20 MHz bandwidth mode.



TCB Grant - Application bGRJm/Z7NT4t1yeeEgK1KQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 04/21/2017

Application Dated: 04/20/2017
LOUIS VUITTON MALLETIER
2, rue du Pont Neuf 75001
PARIS,
France
 
Attention: Xiaohan Lu , Head of Hardware IoT

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ALDGQA00
Name of Grantee:  LOUIS VUITTON MALLETIER
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Louis Vuitton Connected Watch
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.019  

Output power listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. End-users must be informed regarding RF exposure compliance. The highest reported SAR values for body and simultaneous transmission use conditions are 0.093 W/kg, and 0.36 W/kg, respectively.

EAS Grant - Application bGRJm/Z7NT4t1yeeEgK1KQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

LOUIS VUITTON MALLETIER
2, rue du Pont Neuf 75001
PARIS,
France
  Date of Grant: 04/21/2017

Application Dated: 04/20/2017
 
Attention: Xiaohan Lu , Head of Hardware IoT

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ALDGQA00
Name of Grantee:  LOUIS VUITTON MALLETIER
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Louis Vuitton Connected Watch
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.019  

Output power listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. End-users must be informed regarding RF exposure compliance. The highest reported SAR values for body and simultaneous transmission use conditions are 0.093 W/kg, and 0.36 W/kg, respectively.



TCB Grant - Application B2014h2eTjvE684UtBJlOw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 01/17/2018

Application Dated: 01/16/2018
LOUIS VUITTON MALLETIER
2, rue du Pont Neuf 75001
PARIS,
France
 
Attention: Xiaohan Lu , Head of Hardware IoT

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ALDGQA00
Name of Grantee:  LOUIS VUITTON MALLETIER
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Louis Vuitton Connected Watch
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.019  

CIIPC: To add the metal watchband, the SAR testing is performed accordingly to demonstrate RF compliance. . End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements. The highest reported SAR values for body and simultaneous transmission use conditions are 0.09 W/kg (10g), and 0.35 W/kg, respectively.

Output power listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filing. SAR has been evaluated at 0 mm. End-users must be informed regarding RF exposure compliance. The highest reported SAR values for body and simultaneous transmission use conditions are 0.093 W/kg, and 0.36 W/kg, respectively.


EAS Grant - Application B2014h2eTjvE684UtBJlOw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

LOUIS VUITTON MALLETIER
2, rue du Pont Neuf 75001
PARIS,
France
  Date of Grant: 01/17/2018

Application Dated: 01/16/2018
 
Attention: Xiaohan Lu , Head of Hardware IoT

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ALDGQA00
Name of Grantee:  LOUIS VUITTON MALLETIER
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Louis Vuitton Connected Watch
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.019  

CIIPC: To add the metal watchband, the SAR testing is performed accordingly to demonstrate RF compliance. . End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements. The highest reported SAR values for body and simultaneous transmission use conditions are 0.09 W/kg (10g), and 0.35 W/kg, respectively.

Output power listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filing. SAR has been evaluated at 0 mm. End-users must be informed regarding RF exposure compliance. The highest reported SAR values for body and simultaneous transmission use conditions are 0.093 W/kg, and 0.36 W/kg, respectively.



TCB Grant - Application 1kWmOT5Cd+53ncOW727FKQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 01/17/2018

Application Dated: 01/16/2018
LOUIS VUITTON MALLETIER
2, rue du Pont Neuf 75001
PARIS,
France
 
Attention: Xiaohan Lu , Head of Hardware IoT

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ALDGQA00
Name of Grantee:  LOUIS VUITTON MALLETIER
Equipment Class: Digital Transmission System
Notes: Louis Vuitton Connected Watch
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.077  
15C 2402.0  -  2480.0 0.0021  

CIIPC: To add the metal watch band, the SAR testing is performed accordingly to demonstrate RF compliance. . End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements. The highest reported SAR values for body and simultaneous transmission use conditions are 0.27 W/kg (10g), and 0.35 W/kg, respectively.

Output power listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filing. SAR has been evaluated at 0 mm. End-users must be informed regarding RF exposure compliance. The highest reported SAR values for body and simultaneous transmission use conditions are 0.28 W/kg, and 0.36 W/kg, respectively.


EAS Grant - Application 1kWmOT5Cd+53ncOW727FKQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

LOUIS VUITTON MALLETIER
2, rue du Pont Neuf 75001
PARIS,
France
  Date of Grant: 01/17/2018

Application Dated: 01/16/2018
 
Attention: Xiaohan Lu , Head of Hardware IoT

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ALDGQA00
Name of Grantee:  LOUIS VUITTON MALLETIER
Equipment Class: Digital Transmission System
Notes: Louis Vuitton Connected Watch
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.077  
15C 2402.0  -  2480.0 0.0021  

CIIPC: To add the metal watch band, the SAR testing is performed accordingly to demonstrate RF compliance. . End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements. The highest reported SAR values for body and simultaneous transmission use conditions are 0.27 W/kg (10g), and 0.35 W/kg, respectively.

Output power listed is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filing. SAR has been evaluated at 0 mm. End-users must be informed regarding RF exposure compliance. The highest reported SAR values for body and simultaneous transmission use conditions are 0.28 W/kg, and 0.36 W/kg, respectively.



Mail To: