PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC

PCD, LLC Jaguar PRO LTE

Page 1 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 2 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 3 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 4 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 5 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 6 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 7 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 8 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 9 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 10 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 11 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 12 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 13 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 14 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 15 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Page 16 of PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC

Shenzhen Zhongjian Nanfang Testing Co., Ltd.
Report No: CCISE180711006
Cover Page
FCC REPORT
Applicant:
PCD, LLC
Address of Applicant:
1500 Tradeport Drive, ORLANDO, Florida, 32824. United States
Equipment Under Test (EUT)
Product Name:
Jaguar PRO LTE
Model No.:
PL570
Trade mark:
PCD
FCC ID:
2ALJJPL570
Applicable standards:
FCC CFR Title 47 Part 15 Subpart B
Date of sample receipt:
27 Jul., 2018
Date of Test:
27 Jul., to 27 Aug., 2018
Date of report issued:
28 Aug., 2018
Test Result:
PASS *
* In the configuration tested, the EUT complied with the standards specified above.
Authorized Signature:
Bruce Zhang
Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.
This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.
This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.
Report No: CCISE180711006
Version
Version No.
Date
Description
00
28 Aug., 2018
Original
Tested by:
Date:
28 Aug., 2018
Date:
28 Aug., 2018
Test Engineer
Reviewed by:
Project Engineer
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1807110
Page 2 of 18
Report No: CCISE180711006
Contents
Page
COVER PAGE ....................................................................................................................................................... 1
VERSION ............................................................................................................................................................... 2
CONTENTS ........................................................................................................................................................... 3
TEST SUMMARY .................................................................................................................................................. 4
GENERAL INFORMATION .................................................................................................................................. 5
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
CLIENT INFORMATION ...................................................................................................................................................... 5
GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
TEST MODE.................................................................................................................................................................... 5
MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
LABORATORY FACILITY ...................................................................................................................................................... 6
LABORATORY LOCATION ................................................................................................................................................... 6
TEST INSTRUMENTS LIST.................................................................................................................................................... 7
TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
6.1
6.2
CONDUCTED EMISSION ..................................................................................................................................................... 8
RADIATED EMISSION ...................................................................................................................................................... 11
TEST SETUP PHOTO ........................................................................................................................................ 17
EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1807110
Page 3 of 18
Report No: CCISE180711006
Test Summary
Test Item
Section in CFR 47
Result
Conducted Emission
Part 15.107
Pass
Radiated Emission
Part 15.109
Pass
Remark:
Pass: The EUT complies with the essential requirements in the standard.
N/A: The EUT not applicable of the test item.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1807110
Page 4 of 18
Report No: CCISE180711006
General Information
5.1 Client Information
Applicant:
PCD, LLC
Address of Applicant:
1500 Tradeport Drive, ORLANDO, Florida, 32824. United States
Manufacturer:
PCD, LLC
Address:
1500 Tradeport Drive, ORLANDO, Florida, 32824. United States
5.2 General Description of E.U.T.
Product Name:
Jaguar PRO LTE
Model No.:
PL570
Power supply:
Rechargeable Li-ion Battery DC3.8V2800mAh
AC adapter :
Model: PL570
Input: AC100-240V, 50/60Hz, 0.2A
Output: DC 5.0V, 1.0A
5.3 Test Mode
Operating mode
PC mode
Charging+Recording mode
Charging+Playing mode
FM mode
Detail description
Keep the EUT in Downloading mode(Worst case)
Keep the EUT in Charging+Recording mode
Keep the EUT in Charging+Playing mode
Keep the EUT in FM receiver mode
GPS mode
Keep the EUT in GPS receiver mode
The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
vertical polarities were performed. During the test, each emission was maximized by: having the EUT
continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying
antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown
in Test Results of the following pages.
5.4 Measurement Uncertainty
Parameters
Conducted Emission (9kHz ~ 30MHz)
Radiated Emission (9kHz ~ 30MHz)
Radiated Emission (30MHz ~ 1000MHz)
Radiated Emission (1GHz ~ 18GHz)
Radiated Emission (18GHz ~ 40GHz)
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Expanded Uncertainty
±2.22 dB (k=2)
±2.76 dB (k=2)
±4.28 dB (k=2)
±5.72 dB (k=2)
±2.88 dB (k=2)
Project No.: CCISE1807110
Page 5 of 18
Report No: CCISE180711006
5.5 Description of Support Units
Manufacturer
Description
Model
Serial Number
FCC ID/DoC
DELL
PC
OPTIPLEX745
N/A
DoC
DELL
MONITOR
E178FPC
N/A
DoC
DELL
KEYBOARD
SK-8115
N/A
DoC
DELL
MOUSE
MOC5UO
N/A
DoC
LENOVO
Laptop
SL510
2847A65
DoC
5.6 Related Submittal(s) / Grant (s)
This is an original grant, no related submittals and grants.
5.7 Laboratory Facility
The test facility is recognized, certified, or accredited by the following organizations:
 FCC - Registration No.: 727551
Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
(Federal Communications Commission). The Registration No. is 727551.
 IC - Registration No.: 10106A-1
The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
with Registration No.: 10106A-1.
 CNAS - Registration No.: CNAS L6048
Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
Requirements for the Competence of Testing and Calibration laboratories for the competence of
testing. The Registration No. is CNAS L6048.
 A2LA - Registration No.: 4346.01
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
17025:2005 General requirements for the competence of testing and calibration laboratories. The test
scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf
5.8 Laboratory Location
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Tel: +86-755-23118282, Fax: +86-755-23116366
Email: info@ccis-cb.com, Website: http://www.ccis-cb.com
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1807110
Page 6 of 18
Report No: CCISE180711006
5.9 Test Instruments list
Radiated Emission:
CCIS0001
CCIS0005
CCIS0006
Cal. Date
(mm-dd-yy)
07-22-2017
03-16-2018
03-16-2018
Cal. Due date
(mm-dd-yy)
07-21-2020
03-15-2019
03-15-2019
8447D
CCIS0003
03-07-2018
03-06-2019
Compliance Direction
Systems Inc.
PAP-1G18
CCIS0011
03-07-2018
03-06-2019
Rohde & Schwarz
FSP30
CCIS0023
03-07-2018
03-06-2019
Rohde & Schwarz
AUDIX
N/A
N/A
ESRP7
E3
N/A
N/A
CCIS0167
Test Equipment
Manufacturer
Model No.
Inventory No.
Shielding Room
EMI Test Receiver
LISN
LISN
Coaxial Cable
EMI Test Software
ZhongShuo Electron
Rohde & Schwarz
CHASE
Rohde & Schwarz
CCIS
AUDIX
11.0(L)x4.0(W)x3.0(H)
ESCI
MN2050D
ESH3-Z5
N/A
E3
Test Equipment
Manufacturer
Model No.
Inventory No.
3m SAC
BiConiLog Antenna
Horn Antenna
Pre-amplifier
(10kHz-1.3GHz)
Pre-amplifier
(1GHz-18GHz)
Spectrum analyzer
9k-30GHz
EMI Test Receiver
EMI Test Software
Coaxial Cable
Coaxial Cable
SAEMC
SCHWARZBECK
SCHWARZBECK
9(L)*6(W)* 6(H)
VULB9163
BBHA9120D
HP
CCIS0018
CCIS0020
03-07-2018
03-06-2019
Version: 6.110919b
03-07-2018
03-06-2019
03-07-2018
03-06-2019
Conducted Emission:
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Cal.Date
(mm-dd-yy)
CCIS0061
07-22-2017
CCIS0002
03-07-2018
CCIS0074
03-19-2018
8438621/010
07-21-2017
CCIS0086
03-07-2018
Version: 6.110919b
Cal.Due date
(mm-dd-yy)
07-21-2020
03-06-2019
03-18-2019
07-20-2018
03-06-2019
Project No.: CCISE1807110
Page 7 of 18
Report No: CCISE180711006
Test results and Measurement Data
6.1 Conducted Emission
Test Requirement:
FCC Part 15 B Section 15.107
Test Method:
ANSI C63.4:2014
Test Frequency Range:
150kHz to 30MHz
Class / Severity:
Class B
Receiver setup:
RBW=9kHz, VBW=30kHz
Limit:
Limit (dBµV)
Quasi-peak
Average
0.15-0.5
66 to 56*
56 to 46*
0.5-5
56
46
0.5-30
60
50
* Decreases with the logarithm of the frequency.
Class B
Frequency range (MHz)
Test setup:
Test procedure
1. The E.U.T and simulators are connected to the main power through a
line impedance stabilization network(L.I.S.N.). The provide a
50ohm/50uH coupling impedance for the measuring equipment.
2. The peripheral devices are also connected to the main power through
a LISN that provides a 50ohm/50uH coupling impedance with 50ohm
termination. (Please refers to the block diagram of the test setup and
photographs).
3. Both sides of A.C. line are checked for maximum conducted
interference. In order to find the maximum emission, the relative
positions of equipment and all of the interface cables must be changed
according to ANSI C63.4: 2014 on conducted measurement.
Test environment:
Temp.:
Test Instruments:
Refer to section 5.9 for details
Test mode:
Refer to section 5.3 for details
Test results:
Pass
23 C
Humid.:
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
56%
Press.:
101kPa
Project No.: CCISE1807110
Page 8 of 18
Report No: CCISE180711006
Measurement data:
Test Phase: Line
Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1807110
Page 9 of 18
Report No: CCISE180711006
Test Phase: Neutral
Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1807110
Page 10 of 18
Report No: CCISE180711006
6.2 Radiated Emission
Test Requirement:
FCC Part 15 B Section 15.109
Test Method:
ANSI C63.4:2014
Test Frequency Range:
30MHz to 6000MHz
Test site:
Limit:
Measurement Distance: 3m (Semi-Anechoic Chamber)
Frequency
Detector
RBW
VBW
Remark
30MHz-1GHz
Quasi-peak
120kHz
300kHz
Quasi-peak Value
Peak
1MHz
3MHz
Peak Value
Above 1GHz
RMS
1MHz
3MHz
Average Value
Frequency
Limit (dBuV/m @3m)
Remark
30MHz-88MHz
40.0
Quasi-peak Value
88MHz-216MHz
43.5
Quasi-peak Value
216MHz-960MHz
46.0
Quasi-peak Value
960MHz-1GHz
54.0
Quasi-peak Value
54.0
Average Value
Above 1GHz
74.0
Peak Value
Test setup:
Below 1GHz
Receiver setup:
Above 1GHz
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1807110
Page 11 of 18
Report No: CCISE180711006
Test Procedure:
1. The EUT was placed on the top of a rotating table 0.8 meters above the
ground at a 3 meter semi-anechoic camber. The table was rotated 360
degrees to determine the position of the highest radiation.
2. The EUT was set 3 meters away from the interference-receiving
antenna, which was mounted on the top of a variable-height antenna
tower.
3. The antenna height is varied from one meter to four meters above the
ground to determine the maximum value of the field strength. Both
horizontal and vertical polarizations of the antenna are set to make the
measurement.
4. For each suspected emission, the EUT was arranged to its worst case
and then the antenna was tuned to heights from 1 meter to 4 meters
and the rotatable table was turned from 0 degrees to 360 degrees to
find the maximum reading.
5. The test-receiver system was set to Peak Detect Function and Specified
Bandwidth with Maximum Hold Mode.
6. If the emission level of the EUT in peak mode was 10dB lower than the
limit specified, then testing could be stopped and the peak values of the
EUT would be reported. Otherwise the emissions that did not have 10dB
margin would be re-tested one by one using peak, quasi-peak or
average method as specified and then reported in a data sheet.
Test environment:
Temp.:
Test Instruments:
Refer to section 5.9 for details
Test mode:
Refer to section 5.3 for details
Test results:
Passed
Remark:
All of the observed value above 6GHz ware the niose floor , which were no
recorded
25 C
Humid.:
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
55%
Press.:
1 01kPa
Project No.: CCISE1807110
Page 12 of 18
Report No: CCISE180711006
Measurement Data:
Below 1GHz
Test Polarization: Horizontal
Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1807110
Page 13 of 18
Report No: CCISE180711006
Test Polarization: Vertical
Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1807110
Page 14 of 18
Report No: CCISE180711006
Above 1GHz
Test Polarization: Horizontal
Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1807110
Page 15 of 18
Report No: CCISE180711006
Test Polarization: Vertical
Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366
Project No.: CCISE1807110
Page 16 of 18
Download: PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Mirror Download [FCC.gov]PL570 Jaguar PRO LTE Test Report HD 271 S1 PCD, LLC
Document ID3996777
Application IDHCWOG4pSEtyB1BZOA/y/+g==
Document DescriptionTest report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize117.79kB (1472407 bits)
Date Submitted2018-09-09 00:00:00
Date Available2018-09-09 00:00:00
Creation Date2018-08-30 11:08:01
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2018-08-30 11:08:01
Document TitleHD 271 S1
Document CreatorMicrosoft® Word 2010
Document Author: LAB02

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 16
Language                        : zh-CN
Title                           : HD 271 S1
Author                          : LAB02
Creator                         : Microsoft® Word 2010
Create Date                     : 2018:08:30 11:08:01+08:00
Modify Date                     : 2018:08:30 11:08:01+08:00
Producer                        : Microsoft® Word 2010