RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd

Shenzhen Renqing Excellent Investment Co.,Ltd Bluetooth Speaker

FCC ID Filing: 2ALT3-RQZY2201
Purchase on Amazon: Bluetooth Speaker

Download: RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Document TypeTest Report
Document TitleMicrosoft Word - SZ17070188E02_15B.docx

Document

Trouble Loading? Try RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd Download this document or view the HTML Version or PDF in frame.
Page 1 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 2 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 3 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 4 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 5 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 6 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 7 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 8 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 9 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 10 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 11 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 12 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 13 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 14 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 15 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 16 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 17 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 18 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 19 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 20 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 21 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 22 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Page 23 of RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd

REPORT No.:SZ17070188E02
FCC TEST REPORT
APPLICANT
Shenzhen Renqing Excellent Investment Co.,Ltd
PRODUCT NAME
Bluetooth Speaker
MODEL NAME
RAU0585,RAU0586,RAU0587,RAU0588,RAU0589,
RAU0590
TRADE NAME
N/A
BRAND NAME
ROCK, rock space, ROCK Lava
FCC ID
2ALT3-RQZY2201
STANDARD(S)
47 CFR Part 15 Subpart B
TEST DATE
2017-07-30 to 2017-08-11
ISSUE DATE
2017-08-14
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
REPORT No.:SZ17070188E02
DIRECTORY
1. TECHNICAL INFORMATION∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5
1.1. APPLICANT INFORMATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5
1.2. EQUIPMENT UNDER TEST (EUT) DESCRIPTION∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5
2. TEST RESULTS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
2.1. APPLIED REFERENCE DOCUMENTS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
3. TEST CONDITIONS SETTING ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8
3.1. TEST MODE ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8
3.2. TEST SETUP AND EQUIPMENTS LIST∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙9
3.2.1. CONDUCTED EMISSION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙9
3.2.2. RADIATED EMISSION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 11
4. 47 CFR PART 15B REQUIREMENTS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 13
4.1. CONDUCTED EMISSION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 13
4.1.1. REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 13
4.1.2. TEST DESCRIPTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 13
4.1.3. TEST RESULT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 13
4.2. RADIATED EMISSION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 16
4.2.1. REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 16
4.2.2. TEST DESCRIPTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 16
4.2.3. FREQUENCY RANGE OF MEASUREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 16
4.2.4. TEST RESULT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 17
ANNEX A TEST SETUP PHOTOS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 20
ANNEX B TEST UNCERTAINTY ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 22
ANNEX C TESTING LABORATORY INFORMATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 23
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page2 0f 23
REPORT No.:SZ17070188E02
1.
2.
3.
4.
IDENTIFICATION OF THE RESPONSIBLE TESTING LABORATORY ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 23
IDENTIFICATION OF THE RESPONSIBLE TESTING LOCATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙23
ACCREDITATION CERTIFICATE ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 23
TEST ENVIRONMENT CONDITIONS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 23
Change History
Issue
Date
Reason for change
1.0
2017-08-14
First edition
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page3 0f 23
REPORT No.:SZ17070188E02
Test Report Declaration
Applicant
Shenzhen Renqing Excellent Investment Co.,Ltd
Applicant Address
3/F,Block A7 Nanshan iPark,NO.1001 Xueyuan Road, Nanshan
District,Shenzhen
Manufacturer
Shenzhen Dehuida Intelligent Technology Co.,Ltd.
Manufacturer Address
Building D/E,No.237 Xikeng Road,Fucheng Street,Longhua New
District,Shenzhen City,Guangdong Province,P.R.China
Product Name
Bluetooth Speaker
Model Name
RAU0585,RAU0586,RAU0587,RAU0588,RAU0589,RAU0590
Brand Name
ROCK, rock space, ROCK Lava
HW Version
1.0
SW Version
1.0
Test Standards
47 CFR Part 15 Subpart B
Test Result
PASS
Tested by
Wu Zhongwen (Test Engineer)
Approved by
Andy Yeh (Technology Director)
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page4 0f 23
REPORT No.:SZ17070188E02
1. Technical Information
Note: Provided by applicant
1.1. Applicant Information
Company:
Address:
Shenzhen Renqing Excellent Investment Co.,Ltd
3/F,Block A7 Nanshan iPark,NO.1001 Xueyuan Road, Nanshan District,
Shenzhen
1.2. Equipment under Test (EUT) Description
EUT Type: Bluetooth Speaker
Serial No: (N/A, marked #1 by test site)
Hardware Version: 1.0
Software Version: 1.0
Power supply : Battery
Brand Name:
N/A
Model No.:
GSP103450
Serial No.:
(N/A, marked #1 by test site)
Capacity:
1800mAh
Rated Voltage:
3.7V
Charge Limit:
4.2V±0.01V
NOTE:
1.
The application for Bluetooth Speaker RAU0585, RAU0586, RAU0587, RAU0588, RAU0589,
RAU0590.
According to the certificate holder Shenzhen Renqing Excellent Investment Co,ltd, the models
RAU0585,RAU0586,RAU0587,RAU0588,AU0589,AU0590 are accordant in both hardware
platform and software.
Followings are the highlighted items which are same between these six products
a. The number of PCB used in the product.
b. All PCB layout.
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page5 0f 23
REPORT No.:SZ17070188E02
c. Bluetooth module.
d. Power supply mode
e. Operating voltage
The detail difference between these six products, application is as below:
f.
The appearances are different.
2.
The EUT is a Bluetooth Speaker which supports ISM 2.4GHz Bluetooth band.
3.
The EUT is equipped with a Micro USB port which can be connected to ancillary equipments.
4.
For a more detailed description, please refer to specification or user’s manual supplied by the
applicant and/or manufacturer.
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page6 0f 23
REPORT No.:SZ17070188E02
2. Test Results
2.1. Applied Reference Documents
The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:
No.
Identity
Document Title
47 CFR Part 15
Radio Frequency Devices
Test detailed items/section required by FCC rules and results are as below:
No.
Section
Description
Test Date
Result
15.107
Conducted Emission
2017.08.06
PASS
15.109
Radiated Emission
2017.08.07
PASS
NOTE: The tests were performed according to the method of measurements prescribed in ANSI
C63.4-2014.
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page7 0f 23
REPORT No.:SZ17070188E02
3.
Test Conditions Setting
3.1. Test Mode
The first test mode
The EUT configuration of the emission tests is EUT + Battery + PC.
During the measurement, the EUT was connected to a PC via the Micro-B USB port for
software upgrades.
The second test mode
The EUT configuration of the emission tests is EUT + Battery + Adapter.
During the measurement, the EUT was connected to the Adapter via the Micro-B USB
port and charged by the Adapter, meanwhile, the EUT was working normally as an
intentional device.
The third test mode
The EUT configuration of the emission tests is EUT + Battery + Adapter + Mobile
Phone.
During the measurement, the EUT was connected to the Adapter via the Micro-B USB
port and Mobile Phone via the AUX in port, meanwhile, the EUT was working normally
as an intentional device.
NOTE: All test modes are performed in the test, only the worst case (the third) is recorded in this
report.
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page8 0f 23
REPORT No.:SZ17070188E02
3.2. Test Setup and Equipments List
3.2.1. Conducted Emission
A. Test Setup:
The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor,
and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power
mains through a LISN which provides 50Ω/50µH of coupling impedance for the measuring
instrument. A Pulse Limiter is used to protect the measuring instrument. The factors of the whole
test system are calibrated to correct the reading.
The power strip or extension cord has been investigated to make sure that the LISN integrity inma
intained with respect to the impedance characteristics as prescribed in ANSI C63.4-2014
at
Clause 4.3.
B. Equipments List:
Description
Manufacturer
Model
Serial No.
Cal. Date
Due. Date
Receiver
Narda
PMM 9010
595WX11007
2017.05.17
2018.05.16
LISN
Schwarzbeck
NSLK 8127
812744
2017.05.17
2018.05.16
Pulse Limiter
(20dB)
VTSD
9561D
9537
2017.05.17
2018.05.16
Adapter
ZTE
STC-A515A
N/A
N/A
N/A
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page9 0f 23
REPORT No.:SZ17070188E02
C. Test Software Utilized
Model
Version Number
Producer
TS+ -[ JS32-CE]
Version2.5.0.0
Tonscend
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page10 0f 23
REPORT No.:SZ17070188E02
3.2.2. Radiated Emission
A. Test Setup:
1.
For radiated emissions from 30MHz to1GHz
2.
For radiated emissions above 1GHz
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page11 0f 23
REPORT No.:SZ17070188E02
The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of
the site (factors) is calculated to correct the reading.The EUT is placed on a 0.8m high insulating
Turn Table, and keeps 3m away from theTest Antenna, which is mounted onavariable-height
antenna master tower.
For the test Antenna:
In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn
TestAntenna (above 1GHz) are used. Test Antenna is 3m away from the EUT. Test Antenna
height is varied from 1m to 4m above the ground to determine the maximum value of the field
strength. The emission levels at both horizontal and vertical polarizations should be tested.
B. Equipments List:
Description
Manufacturer
Model
Serial No.
Cal. Date
MXE EMI Receiver
Agilent
N9038A
Semi-Anechoic
Chamber
Changning
9m*6m*6m
N/A
2017.01.11
2018.01.10
Test Antenna Bi-Log
Schwarzbeck
VULB 9163
9163-274
2016.12.09
2017.12.08
Test Antenna Horn
Schwarzbeck
BBHA9120C
9120C-384
2017.05.17
2018.05.16
Adapter
ZTE
STC-A515A
N/A
N/A
N/A
MY54130016 2017.05.17
Due. Date
2018.05.16
C. Test Software Utilized
Model
Version Number
Producer
MORLAB EMCR V1.2
Version 1.0
MORLAB
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page12 0f 23
REPORT No.:SZ17070188E02
4.
47 CFR Part 15B Requirements
4.1. Conducted Emission
4.1.1. Requirement
According to FCC section 15.107, the radio frequency voltage that is conducted back onto the
ACpower line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in
thefollowing table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).
Conducted Limit (dBµV)
Frequency range
(MHz)
Quasi-peak
Average
0.15 - 0.50
66 to 56
56 to 46
0.50 - 5
56
46
5 - 30
60
50
NOTE:
a) The limit subjects to the Class B digital device.
b) The lower limit shall apply at the band edges.
c)
The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.
4.1.2. Test Description
See section 3.2.1 of this report.
4.1.3. Test Result
The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and
Average (AV) detectors; the emission levels more than the AV and QP limits, and that have narrow
margins from the AV and QP limits will be re-measured with AV and QP detectors.Tests for both L
phase and N phase lines of the power mains connected to the EUT are performed. All test modes
are considered, refer to recorded points and plots below.
A. Test Plot and Suspicious Points:
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page13 0f 23
REPORT No
o.:SZ1707
70188E02
(Plo
ot A: L Phas
se)
NO
O.
Fre..
Emisssion Level (dBµV)
Limit (dBµV)
Pow
wer-line
Verdict
(MHzz)
Quai-p
peak
Avverage
Quai-peak
Averag
ge
0.15
30.6
60
24.80
66.00
56.00
PASS
0.150
06
35.8
89
30.15
65.97
55.97
PASS
0.550
04
31.7
78
24.53
56.00
46.00
1.269
92
41.8
82
36.15
56.00
46.00
4.655
30.3
31
24.07
56.00
46.00
PASS
13.756
62
29.4
45
22.43
60.00
50.00
PASS
MORLAB
B GROU
UP
Line
PASS
PASS
FL1-3, Bu
uilding A, FeiYang Sccience Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax:: 86-755-36698525
Block67, BaoAn District, She
enZhen , GuangDon
ng Province, P. R. China
Http://www
w.morlab.cn
E-mail: [email protected]
Page14 0f 23
REPORT No
o.:SZ1707
70188E02
(Plott B: N Phase)
NO
O.
Fre..
Emisssion Level (dBµV)
Limit (dBµV)
Pow
wer-line
Verdict
(MHzz)
Quai-p
peak
Avverage
Quai-peak
Averag
ge
0.183
38
36.1
17
29.30
64.31
54.31
PASS
29.994
46
21.9
96
15.90
60.00
50.00
PASS
0.465
52
30.3
35
22.57
56.60
46.60
2.109
98
36.6
66
30.82
56.00
46.00
6.449
96
30.0
07
24.62
60.00
50.00
PASS
14.374
46
33.0
05
25.99
60.00
50.00
PASS
Neutral
PASS
PASS
ass
Result: Pa
MORLAB
B GROU
UP
FL1-3, Bu
uilding A, FeiYang Sccience Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax:: 86-755-36698525
Block67, BaoAn District, She
enZhen , GuangDon
ng Province, P. R. China
Http://www
w.morlab.cn
E-mail: [email protected]
Page15 0f 23
REPORT No.:SZ17070188E02
4.2. Radiated Emission
4.2.1. Requirement
According to FCC section 15.109 (a), the field strength of radiated emissions from
unintentionalradiators at a distance of 3 meters shall not exceed the following values:
Frequency
range (MHz)
Field Strength Limitation at 3m Measurement Dist
(µV/m)
(dBµV/m)
30.0 - 88.0
100
20log 100
88.0 - 216.0
150
20log 150
216.0 - 960.0
200
20log 200
Above 960.0
500
20log 500
As shown in FCCsection 15.35(b), for frequencies above 1000MHz, the field strength limits are
based on average detector. When average radiated emission measurements are specified in this
part, including emission measurements below 1000MHz, there also is a limit on the radio
frequency emissions, as measured using instrumentation with a peak detector function,
corresponding to 20dB above the maximum permitted average limit for the frequency being
investigated unless a different peak emission limit is otherwise specified in the rules.
Note:
1)
2)
The tighter limit shall apply at the boundary between two frequency range.
Limitation expressed in dBµV/m is calculated by 20log Emission Level(µV/m).
4.2.2. Test Description
See section 3.2.2 of this report.
4.2.3. Frequency range of measurement
According to 15.33(b)(1), the frequency range of radiated measurement for the EUT is listed in the
following table:
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page16 0f 23
REPORT No.:SZ17070188E02
4.2.4. Test Result
The maximum radiated emission is searched using PK, QP and AV detectors; the emission levels
more than the limits, and that have narrow margins from the limits will be re-measured with AV and
QP detectors. Both the vertical and the horizontal polarizations of the Test Antenna are considered
to perform the tests. All test modes are considered, refer to recorded points and plots below.
The amplitude of spurious emissions (6GHz-12.5GHz) which are attenuated more than 20 dB
below the permissible value need not be reported.
Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis
test condition was recorded in this test report.
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page17 0f 23
REPORT No.:SZ17070188E02
A. Test Plots and Suspicious Points:
(Plot A: 30MHz – 6GHz, Test Antenna Vertical)
No.
Fre.
Pk
QP
AV
Limit-PK
Limit-QP
Limit-AV
MHz
dBµV/m
dBµV/m
dBµV/m
dBµV/m
dBµV/m
dBµV/m
34.850
N.A.
26.46
N.A.
N.A.
40.00
191.990
N.A.
24.76
N.A.
N.A.
384.050
N.A.
26.25
N.A.
1840.533
43.10
N.A.
3277.120
45.87
5345.600
46.90
MORLAB GROUP
ANT
Verdict
N.A.
PASS
43.50
N.A.
PASS
N.A.
46.00
N.A.
PASS
35.85
74.00
N.A.
54.00
PASS
N.A.
37.02
74.00
N.A.
54.00
PASS
N.A.
39.37
74.00
N.A.
54.00
PASS
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page18 0f 23
REPORT No.:SZ17070188E02
(Plot B: 30MHz – 6GHz, Test Antenna Horizontal)
No.
Fre.
Pk
QP
AV
Limit-PK
Limit-QP
Limit-AV
ANT
Verdict
MHz
dBµV/m
dBµV/m
dBµV/m
dBµV/m
dBµV/m
dBµV/m
191.990
N.A.
24.40
N.A.
N.A.
43.50
N.A.
PASS
239.520
N.A.
27.61
N.A.
N.A.
46.00
N.A.
PASS
384.050
N.A.
26.94
N.A.
N.A.
46.00
N.A.
PASS
1230.933
40.14
N.A.
33.25
74.00
N.A.
54.00
PASS
2826.560
45.66
N.A.
38.64
74.00
N.A.
54.00
PASS
4612.160
45.59
N.A.
39.02
74.00
N.A.
54.00
PASS
Result: Pass
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page19 0f 23
REPORT No.:SZ17070188E02
Annex A
Test Setup Photos
1. Conducted emission main’s port front view
2. Conducted emission main’s port side view
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page20 0f 23
REPORT No.:SZ17070188E02
3. Radiated emission (30MHz-1GHz)
4. Radiated emission (above 1GHz)
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page21 0f 23
REPORT No.:SZ17070188E02
Annex B
Test Uncertainty
The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
Uncertainty in Measurement" (GUM) published by ISO.
Uncertainty of Conducted Emission:
±1.8dB
Uncertainty of Radiated Emission:
±3.1dB
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page22 0f 23
REPORT No.:SZ17070188E02
Annex C
Testing Laboratory Information
1. Identification of the Responsible Testing Laboratory
Company Name:
Shenzhen Morlab Communications Technology Co., Ltd.
Department:
Morlab Laboratory
Address:
FL.3, Building A, FeiYang Science Park, No.8 LongChang
Road, Block 67, BaoAn District, ShenZhen, GuangDong
Province, P. R. China
Responsible Test Lab Manager:
Mr. Su Feng
Telephone:
+86 755 36698555
Facsimile:
+86 755 36698525
2. Identification of the Responsible Testing Location
Name:
Shenzhen Morlab Communications Technology Co., Ltd.
Morlab Laboratory
Address:
FL.3, Building A, FeiYang Science Park, No.8 LongChang
Road, Block 67, BaoAn District, ShenZhen, GuangDong
Province, P. R. China
3. Accreditation Certificate
Accredited Testing Laboratory:
The FCC designation number is CN1192.
(Shenzhen Morlab Communications Technology Co., Ltd.)
4. Test Environment Conditions
During the measurement, the environmental conditions were within the listed ranges:
Temperature (°C):
15 - 35
Relative Humidity (%):
30 - 60
Atmospheric Pressure (kPa):
86 - 106
***** END OF REPORT *****
MORLAB GROUP
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Tel: 86-755-36698555
Fax: 86-755-36698525
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Http://www.morlab.cn
E-mail: [email protected]
Page23 0f 23
Download: RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Mirror Download [FCC.gov]RQZY2201 Bluetooth Speaker Test Report SZ17070188E02_15Bx Shenzhen Renqing Excellent Investment Co.,Ltd
Document ID3548387
Application IDK/aw1OumZEGO12ZeUSTnhg==
Document DescriptionTest Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize85.68kB (1071045 bits)
Date Submitted2017-09-07 00:00:00
Date Available2017-09-08 00:00:00
Creation Date2017-08-24 11:56:54
Producing SoftwareAcrobat Distiller 9.3.2 (Windows)
Document Lastmod2017-08-24 13:15:57
Document TitleSZ17070188E02_15Bx
Document CreatorPScript5.dll Version 5.2.2
Document Author: Morlab

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : Morlab
Create Date                     : 2017:08:24 11:56:54+08:00
Modify Date                     : 2017:08:24 13:15:57+08:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Creator                         : Morlab
Title                           : Microsoft Word - SZ17070188E02_15B.docx
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:08:24 13:15:57+08:00
Producer                        : Acrobat Distiller 9.3.2 (Windows)
Document ID                     : uuid:7c2f0a4a-9065-4cf9-a9ef-903c33b5b387
Instance ID                     : uuid:68e0d671-ea8f-4479-8f24-5984bdd47828
Page Count                      : 23