FCC ID 2AM3Z-UR-A56

Walkie Talkie

by AUSWAY PACIFIC PTY LTD

Grantee Code: 2AM3Z   Product Code: URA56
Latest application date: 2017-09-08

FCC ID Device Details

FCC ID2AM3Z-UR-A56
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AM3Z
Product CodeURA56
Applicant BusinessAUSWAY PACIFIC PTY LTD 🇦🇺
Related Domains crazysales.com.au
Equipment ClassWalkie Talkie
Test FirmShenzhen POCE Technology Co.,Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
136-174 MHzOriginal Equipment2017-09-08

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2017-09-08PDF 682 KB
Internal photosInternal Photos2017-09-08PDF 648.2 KB
External photosExternal Photos2017-09-08PDF 565.6 KB
labelID Label/Location Info2017-09-08PDF 124.1 KB
Test photoTest Setup Photos2017-09-08PDF 227.7 KB
Test ReportTest Report2017-09-08PDF 1.4 MB
Frequency Attestation LetterAttestation Statements2017-09-08PDF 26.6 KB
Agent Authorization LetterCover Letter(s)2017-09-08PDF 13.8 KB
Long Term Confidentiality Request LetterCover Letter(s)2017-09-08PDF 13.7 KB
Model DifferenceCover Letter(s)2017-09-08PDF 33.7 KB
SAR Report Part 1RF Exposure Info2017-09-08PDF 3.9 MB
SAR Report Part 2RF Exposure Info2017-09-08PDF 3.9 MB
Block Diagram Metadata onlyBlock DiagramPDF 2.3 MB
SCH Metadata onlySchematicsPDF 1.1 MB
Operation Instruction Metadata onlyOperational DescriptionPDF 184.4 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 46.6 KB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 30.9 KB

Application Information

Application IDhRBLdqQSZdWLSI3rulZkDQ==
Final Action Date2017-09-08
Application PurposeOriginal Equipment
Applicant FRN0026705780
ModelUR-A56
Frequency Range136-174 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionWalkie Talkie
Responsible PartyHongsheng Fang, Director, VINCENTFANG@CRAZYSALES.COM.AU , 0061(03)86836923
Technical ContactJack Kang, Shenzhen POCE Technology Co.,Ltd., jack@poce-cert.com , 86-755-29113252
Test FirmBill Yuan, Shenzhen POCE Technology Co.,Ltd., bovey@poce-cert.com , 86-755-29113252
TCB Emailtcbinfo@metlabs.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted. Output is at the antenna terminal of the device. This transmitter has been tested for SAR compliance in Push-to-Talk and Body-Worn operating configurations with specific antennas, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50% and SAR compliance for body-worn operating configurations is limited to those described in this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported head and body-worn accessory SAR values at 50% duty factor are 1.67 W/kg and 2.29 W/kg, respectively.

Applications

Application IDDatePurpose
hRBLdqQSZdWLSI3rulZkDQ==2017-09-08Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
136-174 MHz52.5ppm11K0F3E9BD, EF
400-470 MHz52.5ppm11K0F1W9BD, EF

Grants

TCB Grant - Application hRBLdqQSZdWLSI3rulZkDQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Electrical and Electronic Testing NA, Inc
914 W. Patapsco Avenue
Baltimore, MD 21230-3432
Date of Grant: 09/08/2017

Application Dated: 09/08/2017
AUSWAY PACIFIC PTY LTD
Unit 2, 5 Brear St,
Springvale, VIC 3171,
Australia
 
Attention: Hongsheng Fang , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AM3Z-UR-A56
Name of Grantee:  AUSWAY PACIFIC PTY LTD
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Walkie Talkie
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BD EF 90 136.0  -  174.0 5.0 2.5  PM 11K0F3E
BD EF 90 400.0  -  470.0 5.0 2.5  PM 11K0F1W

Power output listed is conducted. Output is at the antenna terminal of the device. This transmitter has been tested for SAR compliance in Push-to-Talk and Body-Worn operating configurations with specific antennas, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50% and SAR compliance for body-worn operating configurations is limited to those described in this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported head and body-worn accessory SAR values at 50% duty factor are 1.67 W/kg and 2.29 W/kg, respectively.

BD: The output power is continuously variable from the value listed in this entry to 10%-15% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

EAS Grant - Application hRBLdqQSZdWLSI3rulZkDQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

AUSWAY PACIFIC PTY LTD
Unit 2, 5 Brear St,
Springvale, VIC 3171,
Australia
  Date of Grant: 09/08/2017

Application Dated: 09/08/2017
 
Attention: Hongsheng Fang , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AM3Z-UR-A56
Name of Grantee:  AUSWAY PACIFIC PTY LTD
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Walkie Talkie
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BD EF 90 136.0  -  174.0 5.0 2.5  PM 11K0F3E
BD EF 90 400.0  -  470.0 5.0 2.5  PM 11K0F1W

Power output listed is conducted. Output is at the antenna terminal of the device. This transmitter has been tested for SAR compliance in Push-to-Talk and Body-Worn operating configurations with specific antennas, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50% and SAR compliance for body-worn operating configurations is limited to those described in this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported head and body-worn accessory SAR values at 50% duty factor are 1.67 W/kg and 2.29 W/kg, respectively.


BD: The output power is continuously variable from the value listed in this entry to 10%-15% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

Mail To: