FCC ID 2AM8F-BW

GPS TRACKER

by Shenzhen Benway Technology Co., Limited

Grantee Code: 2AM8F   Product Code: BW
Latest application date: 2017-09-05

FCC ID Device Details

FCC ID2AM8F-BW
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AM8F
Product CodeBW
Applicant BusinessShenzhen Benway Technology Co., Limited 🇨🇳
Related Domains szbenway.com
Equipment ClassGPS TRACKER
Test FirmShenzhen SEM.Test Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2017-09-05

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2017-09-05PDF 143.2 KB
Internal PhotosInternal Photos2017-09-05PDF 3.6 MB
External PhotosExternal Photos2017-09-05PDF 480.6 KB
Label Info & LocationID Label/Location Info2017-09-05PDF 96 KB
Test Setup PhotosTest Setup Photos2017-09-05PDF 399 KB
Test ReportTest Report2017-09-05PDF 388.4 KB
Confidential Request LetterCover Letter(s)2017-09-05PDF 291.7 KB
Power of Attorney LetterCover Letter(s)2017-09-05PDF 133.6 KB
RF ExposureRF Exposure Info2017-09-05PDF 172.2 KB
Block Diagram Metadata onlyBlock DiagramPDF 39.5 KB
Schematics Metadata onlySchematicsPDF 143.8 KB
Operational Description Metadata onlyOperational DescriptionPDF 49.8 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 10.2 KB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 81.9 KB

Application Information

Application IDom2bhA9AEOpEGj48zlHtLQ==
Final Action Date2017-09-05
Application PurposeOriginal Equipment
Applicant FRN0026732222
ModelBW
Frequency Range824.2-848.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionGPS TRACKER
Responsible PartyAmy Kang, Sales Manager, amy@szbenway.com , (86) 755-25338347
Test FirmJandy So, Shenzhen SEM.Test Technology Co., Ltd., jandyso@semtest.com.cn , 086-755-33663308
TCB Emailtei@timcoengr.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power is EIRP and ERP for above and below 1 GHz, respectively. This device must be installed to provide a separation distance of at least 20-cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with installation instructions and transmitter operating conditions and instructions for satisfying RF exposure compliance. This device contains functions that are not operational in U.S. Territories; this filing is applicable only for U.S. operations.

Applications

Application IDDatePurpose
om2bhA9AEOpEGj48zlHtLQ==2017-09-05Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz0.8690.0741ppm251KGXW22H
1850.2-1909.8 MHz0.43350.0287ppm250KGXW24E

Grants

TCB Grant - Application om2bhA9AEOpEGj48zlHtLQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 09/05/2017

Application Dated: 09/05/2017
Shenzhen Benway Technology Co., Limited
2nd floor, No 1 factory building, LianYi
Street, Liuyue, Henggang, Longgang
ShenZhen, 518000
China
 
Attention: Amy Kang , Sales Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AM8F-BW
Name of Grantee:  Shenzhen Benway Technology Co., Limited
Equipment Class: PCS Licensed Transmitter
Notes: GPS TRACKER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.869 0.0741  PM 251KGXW
24E 1850.2  -  1909.8 0.4335 0.0287  PM 250KGXW

Output Power is EIRP and ERP for above and below 1 GHz, respectively. This device must be installed to provide a separation distance of at least 20-cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with installation instructions and transmitter operating conditions and instructions for satisfying RF exposure compliance. This device contains functions that are not operational in U.S. Territories; this filing is applicable only for U.S. operations.

EAS Grant - Application om2bhA9AEOpEGj48zlHtLQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Benway Technology Co., Limited
2nd floor, No 1 factory building, LianYi Street, Liuyue, Henggang, Longgang
ShenZhen, 518000
China
  Date of Grant: 09/05/2017

Application Dated: 09/05/2017
 
Attention: Amy Kang , Sales Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AM8F-BW
Name of Grantee:  Shenzhen Benway Technology Co., Limited
Equipment Class: PCS Licensed Transmitter
Notes: GPS TRACKER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.869 0.0741  PM 251KGXW
24E 1850.2  -  1909.8 0.4335 0.0287  PM 250KGXW

Output Power is EIRP and ERP for above and below 1 GHz, respectively. This device must be installed to provide a separation distance of at least 20-cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with installation instructions and transmitter operating conditions and instructions for satisfying RF exposure compliance. This device contains functions that are not operational in U.S. Territories; this filing is applicable only for U.S. operations.



Mail To: