WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi

Zimi Mi LevPower X Qi Wireless Charger

Page 1 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Page 2 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Page 3 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Page 4 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Page 5 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Page 6 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Page 7 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Page 8 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Page 9 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Page 10 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Page 11 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Page 12 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Page 13 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Page 14 of WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi

SGS-CSTC Standards Technical Services Co.,
Ltd. Shanghai Branch
588 West Jindu Road, Xinqiao, Songjiang, 201612 Shanghai, China
Telephone:
+86 (0) 21 6191 5666
Fax:
+86 (0) 21 6191 5678
ee.shanghai@sgs.com
Report No.: SHEM180800632702
Page:
1 of 14
Human Exposure Report
Application No.:
FCC ID:
Applicant:
Address of Applicant:
Manufacturer:
Address of Manufacturer:
Factory:
Address of Factory:
SHEM1808006327CR
2AMIN- WTX10
ZIMI CORPORATION
Room A913, No.159 Chengjiang Road, Jiangyin City, Jiangsu Province,
214431, P.R.C
ZIMI CORPORATION
Room A913, No.159 Chengjiang Road, Jiangyin City, Jiangsu Province,
214431, P.R.C
1.Dongguan DBK Energy Technology Co.,Ltd.
2.Suzhou Lineprinting Wireless Communication Co.,Ltd.
3.Shenzhen DBK Electronics Co.,Ltd.
1.No.51 Zhangshen Middle Road,Xuzhen Community,Zhangmutou
Town,Dongguan,Guangdong,P.R.China.
2.Floor 6,Building 40 and Floor 8,Building 39,No.18,Dongchang
Road,SIP,Suzhou,China.
3.Room No.208-1,308,404-408 in Building Five,2-4 Floor in Building
Three,No.8 Qinghua Road,Zhu Village,518109,Fucheng New
Community,Guanlan Street,Longhua District,Shenzhen City,Guangdong
Province,P.R.China.
Equipment Under Test (EUT):
ZMI LevPower X Qi Wireless Charger
EUT Name:
WTX10
Model No.:
47 CFR PART 1, Subpart I, Section 1.1310
Standards:
2018-07-31
Date of Receipt:
2018-07-31 to 2018-08-17
Date of Test:
2018-08-24
Date of Issue:
Test Result :
Pass*
* In the configuration tested, the EUT complied with the standards specified above.
Parlam Zhan
E&E Section Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS
International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS
International Electrical Approvals in writing.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights
and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.
SGS-CSTC Standards Technical Services Co., Ltd.
Shanghai Branch
Report No.: SHEM180800632702
Page:
2 of 16
Revision Record
Version
Description
Date
Remark
00
Original
2018-08-24
Authorized for issue
by:
Vincent Zhu /Project Engineer
Parlam /Reviewer
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shanghai Branch
Report No.: SHEM180800632702
Page:
3 of 16
Contents
Page
COVER PAGE ............................................................................................................................................1
CONTENTS .............................................................................................................................................................. 3
GENERAL INFORMATION .................................................................................................................................... 4
3.1 DETAILS OF E.U.T. ..................................................................................................................................................... 4
3.2 DESCRIPTION OF SUPPORT UNITS ............................................................................................................................... 4
3.3 TEST LOCATION.......................................................................................................................................................... 4
3.4 TEST FACILITY............................................................................................................................................................ 5
3.5 DEVIATION FROM STANDARDS ................................................................................................................................... 5
3.6 ABNORMALITIES FROM STANDARD CONDITIONS ........................................................................................................ 5
EQUIPMENTS USED DURING TEST .................................................................................................................. 6
TEST RESULTS ...................................................................................................................................................... 7
5.1 RF EXPOSURE TEST .................................................................................................................................................... 7
E.U.T. Operation ...................................................................................................................................................... 7
Operating Environment: .......................................................................................................................................... 7
EUT Operation:......................................................................................................................................................... 7
Measurement Data: ................................................................................................................................................. 8
PHOTOGRAPHS ................................................................................................................................................... 12
6.1 TEST PHOTOS ............................................................................................................................................................ 12
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shanghai Branch
Report No.: SHEM180800632702
Page:
4 of 16
General Information
3.1 Details of E.U.T.
Power supply:
DC 5V 2A/9V 1.6A by USB Type-C
Test voltage:
AC 120V 60Hz for USB Type-C
Cable:
DC Cable 1m for USB Port
Wireless Output:
DC 5V, 5W or 9V, 10W
Operation frequency:
110-205 kHz
Antenna type:
Inductive Loop Coil Antenna
Remark:
Tests were conducted in three loads and the worst case is reported only.
3.2 Description of Support Units
The EUT has been tested with associated equipment below.
Description
Load
Manufacturer
Model No.
Serial No.
provided by client
N/A
N/A
Samaung
Galaxy S8
N/A
Mobile Phone
3.3 Test Location
All tests were performed at:
SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch
588 West Jindu Road, Xinqiao, Songjiang, 201612 Shanghai, China
Tel: +86 21 6191 5666
Fax: +86 21 6191 5678
No tests were sub-contracted.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shanghai Branch
Report No.: SHEM180800632702
Page:
5 of 16
3.4 Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
• CNAS (No. CNAS L0599)
CNAS has accredited SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. to ISO/IEC
17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories
(CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration Laboratories) for the
competence in the field of testing.
• NVLAP (Certificate No. 201034-0)
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. is accredited by the National Voluntary
Laboratory Accreditation Program(NVLAP). Certificate No. 201034-0.
• FCC –Designation Number: CN5033
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. has been recognized as an accredited
testing laboratory.
Designation Number: CN5033. Test Firm Registration Number: 479755.
• Industry Canada (IC) – IC Assigned Code: 8617A
The 3m Semi-anechoic chamber of SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.
has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment
testing with Registration No.: 8617A-1.
• VCCI (Member No.: 3061)
The 3m Semi-anechoic chamber and Shielded Room of SGS-CSTC Standards Technical Services
(Shanghai) Co., Ltd. has been registered in accordance with the Regulations for Voluntary Control
Measures with Registration No.: R-3868, C-4336, T-12221, G-10830 respectively.
3.5 Deviation from Standards
None.
3.6 Abnormalities from Standard Conditions
None.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shanghai Branch
Report No.: SHEM180800632702
Page:
6 of 16
Equipments Used during Test
Item
Test Equipment
Manufacturer
Model No. Inventory No.
Cal Date
Cal. Due date
(yyyy-mm-dd)
(yyyy-mm-dd)
3m Semi-Anechoic
Chamber
ST
N/A
SHEM078-2
2017-07-20
2020-07-21
Electromagnetic
Field Probe
WANDEL &
GOLTERMANN
EMR-20
SHEM0907
2018-04-10
2019-04-11
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shanghai Branch
Report No.: SHEM180800632702
Page:
7 of 16
Test Results
5.1 RF Exposure test
Test Requirement:
47 CFR PART 1, Subpart I, Section 1.1310
Measurement Distance:
15 cm for surrounding the device and 20 cm for above the top surface.
Test voltage
Input:DC 5V 2A/DC 9V,1.6A, Wireless Output:5V 5W/9V 10W
Limit:
Frequency range Electric field strength Magnetic field strength Power density Averaging time
(MHz)
(V/m)
(A/m)
(mW/cm2)
(minutes)
(A) Limits for Occupational/Controlled Exposures
0.3-3.0
614
1.63
*(100)
3.0-30
1842/f
4.89/f
*(900/f2)
30-300
61.4
0.163
1.0
300-1500
f/300
1500-100,000
(B) Limits for General Population/Uncontrolled Exposure
0.3-1.34
614
1.63
*(100)
30
1.34-30
824/f
2.19/f
*(180/f2)
30
30-300
27.5
0.073
0.2
30
300-1500
f/1500
30
1500-100,000
1.0
30
F=frequency in MHz
*=Plane-wave equivalent power density
RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules.
The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits for
150kHz:614V/m,1.63A/m).
E.U.T. Operation
Operating Environment:
Temperature:
24.0 C
Humidity:
52 % RH
Atmospheric Pressure: 1015 mbar
EUT Operation:
This device has been tested the worst status(AC input) of full load and the device has been tested
with mobile phone at zero charge, intermediate charge, and full charge.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shanghai Branch
Report No.: SHEM180800632702
Page:
8 of 16
Measurement Data:
1: When use three type load to test, the worst case is Output Voltage=DC 5V; The max output
power =5W;Calculation of resistor value=5Ω (DC 5V/1A)
Electric Field Emissions
Test Position
Operating
Frequency
Test
Distance
(cm)
Probe
Measure
Result
Limit
50% Limit
(V/m)
(V/m)
(V/m)
Side 1
118KHz
15
7.32
614
307
Side 2
118KHz
15
7.54
614
307
Side 3
118KHz
15
7.15
614
307
Side 4
118KHz
15
6.92
614
307
Top
118KHz
20
8.74
614
307
Bottom
118KHz
15
7.37
614
307
Test
Distance
Probe
Measure
Result
Limit
50% Limit
(A/m)
(A/m)
Magnetic Field Emissions
Test Position
Operating
Frequency
(cm)
(A/m)
Side 1
118KHz
15
0.0954
1.63
0.815
Side 2
118KHz
15
0.0965
1.63
0.815
Side 3
118KHz
15
0.0963
1.63
0.815
Side 4
118KHz
15
0.0918
1.63
0.815
Top
118KHz
20
0.2276
1.63
0.815
Bottom
118KHz
15
0.1108
1.63
0.815
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shanghai Branch
Report No.: SHEM180800632702
Page:
9 of 16
2: When use three type load to test, the worst case is Output Voltage=DC 9V; The max output
power =10W;Calculation of resistor value=8.1Ω (DC 9V/1.11A)
Electric Field Emissions
Test Position
Operating
Frequency
Test
Distance
(cm)
Probe
Measure
Result
Limit
50% Limit
(V/m)
(V/m)
(V/m)
Side 1
118KHz
15
8.95
614
307
Side 2
118KHz
15
8.42
614
307
Side 3
118KHz
15
8.63
614
307
Side 4
118KHz
15
8.72
614
307
Top
118KHz
20
9.64
614
307
Bottom
118KHz
15
8.68
614
307
Test
Distance
Probe
Measure
Result
Limit
50% Limit
(A/m)
(A/m)
Magnetic Field Emissions
Test Position
Operating
Frequency
(cm)
(A/m)
Side 1
118KHz
15
0.1084
1.63
0.815
Side 2
118KHz
15
0.1164
1.63
0.815
Side 3
118KHz
15
0.1086
1.63
0.815
Side 4
118KHz
15
0.1038
1.63
0.815
Top
118KHz
20
0.2847
1.63
0.815
Bottom
118KHz
15
0.1376
1.63
0.815
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shanghai Branch
Report No.: SHEM180800632702
Page:
10 of 16
3:Mobile phone has been charge at zero charge, intermediate charge, and full charge.
The Maximum value has been recorded in the below table.(DC 5V 5W)
Electric Field Emissions
Test
Operating
Position
Frequency
Side 1
115kHz
Side 2
115kHz
Side 3
115kHz
Side 4
115kHz
Top
115kHz
Bottom
115kHz
Test
Distance
(cm)
Probe Measure Result(V/m)
zero
charge
intermediate
charge
full
charge
15
6.42
6.85
7.15
15
6.49
7.13
7.41
15
6.84
6.94
7.34
15
6.22
6.57
7.02
20
7.95
8.26
8.42
15
6.78
7.02
7.29
Limit(V/m)/
50%Limit(V/m)
614/307
614/307
614/307
614/307
614/307
614/307
Magnetic Field Emissions
Position
Frequency
Test
Distance
(cm)
Side 1
115kHz
15
0.0798
0.0844
0.0942
Side 2
115kHz
15
0.0812
0.0923
0.0951
Side 3
115kHz
15
0.0856
0.0927
0.0991
Side 4
115kHz
15
0.0829
0.0895
0.0912
Top
115kHz
20
0.1965
0.2065
0.2133
Bottom
115kHz
15
0.1084
0.1123
0.1088
Test
Operating
Probe Measure Result(A/m)
zero
charge
intermediate
charge
full
charge
Limit(A/m)/
50%Limit(A/m)
1.63/0.815
1.63/0.815
1.63/0.815
1.63/0.815
1.63/0.815
1.63/0.815
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shanghai Branch
Report No.: SHEM180800632702
Page:
11 of 16
4:Mobile phone has been charge at zero charge, intermediate charge, and full charge.
The Maximum value has been recorded in the below table.(DC 9V 10W)
Electric Field Emissions
Test
Operating
Position
Frequency
Side 1
115kHz
Side 2
115kHz
Side 3
115kHz
Side 4
115kHz
Top
115kHz
Bottom
115kHz
Test
Distance
(cm)
Probe Measure Result(V/m)
zero
charge
intermediate
charge
full
charge
15
7.23
7.85
8.26
15
7.32
7.53
8.17
15
7.71
7.92
8.32
15
6.96
7.68
8.29
20
8.05
8.26
9.27
15
6.85
7.37
8.19
Limit(V/m)/
50%Limit(V/m)
614/307
614/307
614/307
614/307
614/307
614/307
Magnetic Field Emissions
Test
Operating
Position
Frequency
Side 1
115kHz
Side 2
115kHz
Side 3
115kHz
Side 4
115kHz
Top
115kHz
Bottom
115kHz
Test
Distance
(cm)
Probe Measure Result(A/m)
zero
charge
intermediate
charge
full
charge
15
0.0842
0.0964
0.1043
15
0.0913
0.0921
0.1115
15
0.0865
0.0987
0.1027
15
0.0812
0.0845
0.1018
20
0.1865
0.2125
0.2531
15
0.0976
0.1097
0.1176
Limit(A/m)/
50%Limit(A/m)
1.63/0.815
1.63/0.815
1.63/0.815
1.63/0.815
1.63/0.815
1.63/0.815
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shanghai Branch
Report No.: SHEM180800632702
Page:
12 of 16
Photographs
6.1 Test photos
Side 1
Side 2
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shanghai Branch
Report No.: SHEM180800632702
Page:
13 of 16
Side 3
Side 4
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shanghai Branch
Report No.: SHEM180800632702
Page:
14 of 16
Top
Bottom
- End of the Report -
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
Download: WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Mirror Download [FCC.gov]WTX10 Mi LevPower X Qi Wireless Charger RF Exposure Info HD 271 S1 Zimi
Document ID3986995
Application ID7kQEOxlMbGKaG77xjmXC4g==
Document DescriptionRF Exposure Info
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize53.56kB (669501 bits)
Date Submitted2018-09-01 00:00:00
Date Available2018-09-01 00:00:00
Creation Date2018-08-31 09:02:23
Producing SoftwareMicrosoft® Word 2016
Document Lastmod2018-08-31 09:02:23
Document TitleHD 271 S1
Document CreatorMicrosoft® Word 2016
Document Author: LAB02

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 14
Language                        : zh-CN
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Microsoft® Word 2016
Title                           : HD 271 S1
Creator                         : LAB02
Creator Tool                    : Microsoft® Word 2016
Create Date                     : 2018:08:31 09:02:23+08:00
Modify Date                     : 2018:08:31 09:02:23+08:00
Document ID                     : uuid:727EDD4E-B210-411A-BAD7-BC29BDAE1101
Instance ID                     : uuid:727EDD4E-B210-411A-BAD7-BC29BDAE1101
Author                          : LAB02