FCC ID 2AMUD-M100
Portable Power Station
by Duracell U.S. Operations, Inc.
Grantee Code: 2AMUD Product Code: M100
Latest application date: 2024-07-18
FCC ID Device Details
| FCC ID | 2AMUD-M100 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AMUD |
| Product Code | M100 |
| Applicant Business | Duracell U.S. Operations, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | Portable Power Station |
| Test Firm | Shenzhen LCS Compliance Testing Laboratory Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 0.11-0.205 MHz | Original Equipment | 2024-07-18 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2024-07-18 | PDF 300.8 KB |
| Internal Photos | Internal Photos | 2024-07-18 | PDF 3.5 MB |
| External Photos | External Photos | 2024-07-18 | PDF 800.4 KB |
| Label and Location-FCC | ID Label/Location Info | 2024-07-18 | PDF 510.5 KB |
| Test Setup Photos | Test Setup Photos | 2024-07-18 | PDF 430.9 KB |
| Antenna spcification_earphone coil | Test Report | 2024-07-18 | PDF 131.1 KB |
| Antenna spcification_phone coil | Test Report | 2024-07-18 | PDF 162.1 KB |
| Test Report | Test Report | 2024-07-18 | PDF 1.4 MB |
| Covered Equipment Attestation_2.911(d)(5)(i) and (ii | Attestation Statements | 2024-07-18 | PDF 87.9 KB |
| US_Agent | Attestation Statements | 2024-07-18 | PDF 92 KB |
| FCC Confidentiality request letter | Cover Letter(s) | 2024-07-18 | PDF 131.7 KB |
| FCC POA | Cover Letter(s) | 2024-07-18 | PDF 134.5 KB |
| RF Exposure-MPE | RF Exposure Info | 2024-07-18 | PDF 1 MB |
| block diagram Metadata only | Block Diagram | PDF 78.9 KB | |
| schematic Metadata only | Schematics | PDF 590 KB | |
| Operation Description-FCC Metadata only | Operational Description | PDF 182.7 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 104.5 KB |
Application Information
| Application ID | rIE30EcJ4wGANRMVyYNMgA== |
|---|---|
| Final Action Date | 2024-07-18 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0025298753 |
| Model | M100 |
| Frequency Range | 0.11-0.205 MHz |
| Equipment Class | DCD - Part 15 Low Power Transmitter Below 1705 kHz |
| Device Description | Portable Power Station |
| Responsible Party | Laura Zadrick, zadrick.lj@duracell.com |
| Test Firm | Gavin Liang, Shenzhen LCS Compliance Testing Laboratory Ltd., gavin.liang@lcs-cert.com |
| TCB Email | JoerdisMitzloff@eurofins.de |
| TCB Scope | A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | The FCC certification of this device refers to RF exposure testing performed in typical operating conditions, where a person is no closer than 20 centimeters from the device surface at all times, except for non-repetitive patterns with transient time intervals in the order of a second. Only in the stated conditions, the device is shown to fully comply with the FCC RF Exposure requirements of KDB 447498. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| rIE30EcJ4wGANRMVyYNMgA== | 2024-07-18 | Original Equipment |
Equipment Authorization
| Frequency | Rules |
|---|---|
| 0.11-0.205 MHz | 15C |
Grants
TCB Grant - Application rIE30EcJ4wGANRMVyYNMgA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 07/18/2024 Application Dated: 07/17/2024 |
| Duracell U.S. Operations, Inc. |
| Berkshire Corporate Park |
| 14 Research Drive |
| Bethel, CT 06801 |
| Attention: Laura Zadrick |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AMUD-M100 |
| Name of Grantee: | Duracell U.S. Operations, Inc. |
| Equipment Class: | Part 15 Low Power Transmitter Below 1705 kHz |
| Notes: | Portable Power Station |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 0.1101 - 0.205 |
| The FCC certification of this device refers to RF exposure testing performed in typical operating conditions, where a person is no closer than 20 centimeters from the device surface at all times, except for non-repetitive patterns with transient time intervals in the order of a second. Only in the stated conditions, the device is shown to fully comply with the FCC RF Exposure requirements of KDB 447498. |
EAS Grant - Application rIE30EcJ4wGANRMVyYNMgA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Duracell U.S. Operations, Inc. Berkshire Corporate Park 14 Research Drive Bethel, CT 06801 United States |
Date of Grant: 07/18/2024 Application Dated: 07/17/2024 |
| Attention: Laura Zadrick |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AMUD-M100 |
| Name of Grantee: | Duracell U.S. Operations, Inc. |
| Equipment Class: | Part 15 Low Power Transmitter Below 1705 kHz |
| Notes: | Portable Power Station |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 0.1101 - 0.205 |
| The FCC certification of this device refers to RF exposure testing performed in typical operating conditions, where a person is no closer than 20 centimeters from the device surface at all times, except for non-repetitive patterns with transient time intervals in the order of a second. Only in the stated conditions, the device is shown to fully comply with the FCC RF Exposure requirements of KDB 447498. |
| Mail To: |