FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited

Golden Mark (HK) Limited Fan Control

Page 1 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 2 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 3 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 4 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 5 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 6 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 7 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 8 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 9 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 10 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 11 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 12 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 13 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 14 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 15 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 16 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 17 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 18 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 19 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 20 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 21 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 22 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Page 23 of FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited

REPORT No.:SZ17110127W01
TEST REPORT
APPLICANT
: Golden Mark (HK) Limited
PRODUCT NAME
: Fan Control
MODEL NAME
BRAND NAME
: N/A
FCC ID
: 2AMY9FC100
STANDARD(S)
: 47 CFR Part 15 Subpart C
TEST DATE
: 2018-01-15 to 2018-01-18
ISSUE DATE
: 2018-01-23
HS-FC200+ / FC100 / ZWP-FC-100
/ ZL-FC-100
Tested by:
Wu Junke (Test Engineer)
Approved by:
Peng Huarui ( Supervisor )
NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
REPORT No.:SZ17110127W01
DIRECTORY
1. Technical Information ··················································································· 4
1.1. Applicant and Manufacturer Information ······················································· 4
1.2. Equipment Under Test (EUT) Description ······················································ 4
1.3. Test Standards and Results ········································································ 5
1.4. Environmental Conditions ·········································································· 5
2. 47 CFR Part 15C Requirements ······································································ 6
2.1. Antenna requirement ················································································· 6
2.2. Bandwidth ································································································ 7
2.3. Conducted Emission ·················································································· 9
2.4. Field strength of fundamental····································································· 12
2.5. Radiated Emission and field strength of harmonics ······································ 14
Annex A Test Uncertainty ················································································ 20
Annex B Testing Laboratory Information ··························································· 21
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 2 0f 23
REPORT No.:SZ17110127W01
Change History
Issue
Date
Reason for change
1.0
2018-01-23
First edition
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 3 0f 23
REPORT No.:SZ17110127W01
1. Technical Information
Note: Provide by applicant.
1.1. Applicant and Manufacturer Information
Applicant:
Golden Mark (HK) Limited
Applicant Address:
6/F., Kimberley Plaza, 45-47 Kimberley Road, Tsim Sha Tsui,
Kowloon, Hong Kong
Golden Mark (HK) Limited
Manufacturer:
Manufacturer Address:
6/F., Kimberley Plaza, 45-47 Kimberley Road, Tsim Sha Tsui,
Kowloon, Hong Kong
1.2. Equipment Under Test (EUT) Description
Product Name:
Fan Control
Serial No:
(N/A, marked #1 by test site)
Hardware Version:
N/A
Software Version:
N/A
Operating Frequency:
908.4MHz; 916.0MHz
Antenna Type:
PCB Antenna
Antenna Gain:
4 dBi
Note 1: The EUT is only operating at 908.4MHz and 916MHz.
Note 2: According to the certificate holder, they declared that the models: HS-FC200+ / FC100 /
ZWP-FC-100 / ZL-FC-100 are accordant in both hardware and software. These models only differ
in application information. The detail difference for Fan Control application is as below:
Model Number
Feature Description
HS-FC200+
4 RGB LED in the unit
FC100
4 white LED in the unit
ZWP-FC-100
4 white LED in the unit
ZL-FC-100
4 white LED in the unit
The main measuring model is HS-FC200+, only the results for HS-FC200+ was recorded in this
report.
Note 3: For a more detailed description, please refer to Specification or User’s Manual supplied by
the applicant and/or manufacturer.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 4 0f 23
REPORT No.:SZ17110127W01
1.3. Test Standards and Results
The objective of the report is to perform testing according to 47 CFR Part 15 Subpart C for the EUT
FCC ID Certification:
No
Identity
Document Title
47 CFR Part 15 (10-1-15 Edition)
Radio Frequency Devices
Test detailed items/section required by FCC rules and results are as below:
No.
Section
Description
Test Date
Test Engineer
Result
N/A
N/A
PASS
15.203
Antenna Requirement
15.215
Bandwidth
Jan 18, 2018
Wu Junke
PASS
15.207
Conducted Emission
Jan 16, 2018
Wu Junke
PASS
15.249(a)
Field strength
Jan 15, 2018
Wu Junke
PASS
15.209,
15.249(a)
Radiated Emission and field
strength of harmonics
Jan 16, 2018
Wu Junke
PASS
Note: The tests were performed according to the method of measurements prescribed in
ANSIC63.10-2013.
1.4. Environmental Conditions
During the measurement, the environmental conditions were within the listed ranges:
Temperature (°C):
15 - 35
Relative Humidity (%):
30 -60
Atmospheric Pressure (kPa):
86-106
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 5 0f 23
REPORT No.:SZ17110127W01
2. 47 CFR Part 15C Requirements
2.1. Antenna requirement
2.1.1. Applicable Standard
According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other
than that furnished by the responsible party shall be used with the device. The use of a
permanently attached antenna or of an antenna that uses a unique coupling to the intentional
radiator shall be considered sufficient to comply with the provisions of this section.
2.1.2. Result: Compliant
The EUT has a permanently and irreplaceable attached antenna. Please refer to the EUT internal
photos.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 6 0f 23
REPORT No.:SZ17110127W01
2.2. Bandwidth
2.2.1. Requirement
Refer to FCC 15.215
2.2.2. Test Description
A. Test Set:
The EUT is coupled to the Spectrum Analyzer; the RF load attached to the EUT antenna terminal
is 50Ohm; the path loss as the factor is calibrated to correct the reading.
Make the measurement with the spectrum analyzer's resolution bandwidth (RBW) = 10 kHz. In
order to make an accurate measurement, set the span greater than RBW.
B. Equipments List:
Please reference ANNEX A(1.5).
2.2.3. Test Result
A.
Test Verdict:
Channel
Frequency (MHz)
20 dB Bandwidth (kHz)
Result
908.4
104.9
PASS
916.0
160.9
PASS
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 7 0f 23
REPORT No.:SZ17110127W01
B. Test Plots:
(Channel 1: 908.4MHz)
(Channel 2: 916.0 MHz)
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 8 0f 23
REPORT No.:SZ17110127W01
2.3. Conducted Emission
2.3.1. Requirement
According to FCC section 15.207, for an intentional radiator that is designed to be connected to the
public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power
line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following
table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).
range Conducted Limit (dBµV)
Frequency
(MHz)
Quai-peak
Average
0.15 - 0.50
66 to 56
56 to 46
0.50 - 5
56
46
5 - 30
60
50
NOTE:
(a) The lower limit shall apply at the band edges.
(b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.
2.3.2. Test Description
A. Test Setup:
The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal
reference ground plane. EUT was connected to LISN and LISN was connected to reference
Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI
C63.10: 2013.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 9 0f 23
REPORT No.:SZ17110127W01
B. Equipments List:
Please reference ANNEX A(1.5).
2.3.3. Test Result
The maximum conducted interference is searched using Peak (PK), if the emission levels more
than the AV and QP limits, and that have narrow margins from the AV and QP limits will be
re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power
mains connected to the EUT are performed. Refer to recorded points and plots below.
A. Test setup:
The EUT configuration of the emission tests is EUT + Link.
Note: The test voltage is AC 120V/60Hz.
B. Test Plots:
(Plot A: L Phase)
Emission Level (dBµV)
Limit (dBµV)
Fre.
(MHz)
Quai-peak
Average
Quai-peak
Average
0.115
37.84
31.59
65.73
55.73
PASS
0.29
33.72
27.67
60.38
50.38
PASS
0.53
32.90
26.70
56.00
46.00
0.76
29.87
24.17
56.00
46.00
1.46
41.43
35.63
56.00
46.00
PASS
18.95
24.58
16.37
60.00
50.00
PASS
NO.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Power-line
Line
Verdict
PASS
PASS
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 10 0f 23
REPORT No.:SZ17110127W01
(Plot B: N Phase)
Emission Level (dBµV)
Limit (dBµV)
Fre.
(MHz)
Quai-peak
Average
Quai-peak
Average
0.17
37.30
30.97
65.21
55.21
PASS
0.27
34.32
28.36
61.01
51.01
PASS
0.48
33.85
27.61
56.33
46.33
0.86
41.00
39.97
56.00
46.00
1.47
41.37
35.54
56.00
46.00
PASS
19.30
24.15
15.49
60.00
50.00
PASS
NO.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Power-line
Neutral
Verdict
PASS
PASS
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 11 0f 23
REPORT No.:SZ17110127W01
2.4. Field strength of fundamental
2.4.1. Requirement
According to FCC section 15.249(a), except as provided in paragraph (b) of this section, the field
strength of emissions from intentional radiators operated within these frequency bands shall
comply with the following:
Fundamental
frequency
Field strength of fundamental
(millivolts/meter)
Field strength of harmonics
(microvolts/meter)
902-928 MHz
50
500
2400-2483.5 MHz
50
500
5725-5875 MHz
50
500
24.0-24.25 GHz
250
2500
2.4.2. Test Description
A. Test Setup:
The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of
the site as factors are calculated to correct the reading.
For the Test Antenna:
Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the
ground to determine the maximum value of the field strength.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 12 0f 23
REPORT No.:SZ17110127W01
B. Equipments List:
Please reference ANNEX A(1.5).
2.4.3. Test Procedure
Use the following spectrum analyzer settings:
Span = wide enough to fully capture the emission being measured
RBW = 120 kHz
VBW ≥ RBW
Sweep = auto
Detector function = peak
Trace = max hold
2.4.4. Test Result
The measurement results are obtained as below:
E [dBμV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB]
AT: Total correction Factor except Antenna
UR: Receiver Reading
Gpreamp: Preamplifier Gain
AFactor: Antenna Factor at 3m
During the test, the total correction Factor AT and AFactor were built in test software.
Note: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis
test condition was recorded in this test report
A. Test Verdict:
Frequency
(MHz)
Detector
QP
Receiver
Reading
UR
(dBuV)
AT (dB)
AFactor
(dB@3m)
Max.
Emission
Limit
Verdict
(dBµV/m)
(dBµV/m)
908.4
QP
57.35
2.24
28.50
88.09
94
Pass
916.0
QP
52.39
2.24
28.50
83.13
94
Pass
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 13 0f 23
REPORT No.:SZ17110127W01
2.5. Radiated Emission and field strength of harmonics
2.5.1. Requirement
According to section 15.249(a), the field strength of emissions from intentional radiators operated
within these frequency bands shall comply with the following:
Fundamental
frequency
Field strength of fundamental
(millivolts/meter)
Field strength of harmonics
(microvolts/meter)
902-928 MHz
50
500
2400-2483.5 MHz
50
500
5725-5875 MHz
50
500
24.0-24.25 GHz
250
2500
According to section 15.249(d), Emission Radiated outside of the specified frequency bands,
except for harmonics, shall be attenuated by at least 50dB below the level of the fundamental or to
the general radiated emission limits in Section 15.209:
Frequency
(MHz)
Field Strength
(µV/m)
Measurement
Distance (m)
0.009 - 0.490
2400/F(kHz)
0.490 - 1.705
Field Strength Limitation at 3m Measurement
Distance
(uV/m)
(dBuV/m)
300
10000*
2400/F(KHz)
20log 2400/F(KHz) + 80
24000/F(kHz)
30
100* 2400/F(KHz)
20log 2400/F(KHz) + 40
1.705 - 30.0
30
30
100*30
20log 30 + 40
30 - 88
100
100
20log 100
88 - 216
150
150
20log 150
216 - 960
200
200
20log 200
Above 960
500
500
20log 500
According to section 15.249(e), for frequencies above 1000MHz, the above field strength limits are
based on average limits. The peak field strength of any emission shall not exceed the maximum
permitted average limits specified above by more than 20dB under any condition of modulation.
Note:
1) The tighter limit shall apply at the boundary between two frequency range.
2) Limitation expressed in dBuV/m is calculated by 20log Emission Level(uV/m).
3) If measurement is made at 3m distance, then F.S Limitation at 3m distance is adjusted by using
theformula of Ld1 = Ld2 * (d2/d1)2.
Example: F.S Limit at 30m distance is 30uV/m, then F.S Limitation at 3m distance is adjusted as
Ld1 = L1 = 30uV/m * (10)2 = 100 * 30uV/m
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 14 0f 23
REPORT No.:SZ17110127W01
2.5.2. Test Description
A. Test Setup:
1)
For radiated emissions from 9kHz to 30MHz
2)
For radiated emissions from 30MHz to1GHz
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 15 0f 23
REPORT No.:SZ17110127W01
3)
For radiated emissions above 1GHz
The RF absorbing material used on the reference ground plane and on the turntable have a
maximum height (thickness) of 30 cm (12 in) and have a minimum-rated attenuation of 20 dB at all
frequencies from 1 GHz to 18 GHz. Test site have a minimum area of the ground plane covered
with RF absorbing material as specified in Figure 6 of ANSI C63.4: 2014.
The test site semi-anechoic chamber has met the requirement of NSA tolerance 4dB according to
the standards: ANSI C63.10:2013. For radiated emissions below or equal to 1GHz, The EUT was
set-up on insulator 80cm above the Ground Plane, For radiated emissions above 1GHz, The EUT
was set-up on insulator 150cm above the Ground Plane. The set-up and test methods were
according to ANSI C63.10:2013.
The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of
the site as factors are calculated to correct the reading.
For the Test Antenna:
(a) In the frequency range of 9 kHz to 30MHz, magnetic field is measured with Loop Test Antenna.
The Test Antenna is positioned with its plane vertical at 1m distance from the EUT. The center of
the Loop Test Antenna is 1m above the ground. During the measurement the Loop Test Antenna
rotates about its vertical axis for maximum response at each azimuth about the EUT.
(b) In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test
Antenna (above 1GHz) are used. Place the test antenna at 3m away from area of the EUT, while
keeping the test antenna aimed at the source of emissions at each frequency of significant
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 16 0f 23
REPORT No.:SZ17110127W01
emissions, with polarization oriented for maximum response. The test antenna may have to be
higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed
at the emission source for receiving the maximum signal. The final test antenna elevation shall be
that which maximizes the emissions. The test antenna elevation for maximum emissions shall be
restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane.
The emission levels at both horizontal and vertical polarizations should be tested.
B. Equipments List:
Please reference ANNEX A(1.5).
2.5.3. Test Result
According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than
amplitudes measured with the quasi-peak (or average) detector, the measurement data from a
spectrum analyzer peak detector will represent the worst-case results, if the peak measured value
complies with the quasi-peak limit, it is unnecessary to perform an quasi-peak measurement.
The measurement results are obtained as below:
E [dBμV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB]
AT: Total correction Factor except Antenna
UR: Receiver Reading
Gpreamp: Preamplifier Gain
AFactor: Antenna Factor at 3m
During the test, the total correction Factor A T and A Factor were built in test software.
Note: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis
test condition was recorded in this test report.
The low frequency, which started from 9 kHz to 30MHz, was pre-scanned and the result which was
20dB lower than the limit line per 15.31(o) was not reported.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 17 0f 23
REPORT No.:SZ17110127W01
Test Plots
Fre.
(MHz)
36.070
Pk
(dBμV/m)
23.28
QP
(dBμV/m)
N/A
AV
(dBμV/m)
N/A
Limit-PK
(dBμV/m)
N/A
Limit-QP
(dBμV/m)
40.00
Limit-AV
(dBμV/m)
N/A
Antenna
Verdict
Horizontal
PASS
908.949
31.12
N/A
N/A
N/A
N/A
N/A
Horizontal
N/A
1816.800
42.47
N/A
33.84
74.0
N/A
54.00
Horizontal
PASS
2645.100
44.25
N/A
31.85
74.0
N/A
54.00
Horizontal
PASS
4542.100
49.65
N/A
44.38
74.0
N/A
54.00
Horizontal
PASS
6358.900
53.33
N/A
49.54
74.0
N/A
54.00
Horizontal
PASS
(908.4MHz, Antenna Horizontal, 30MHz to 10GHz)
Fre.
(MHz)
61.564
Pk
(dBμV/m)
25.92
QP
(dBμV/m)
N/A
AV
(dBμV/m)
N/A
Limit-PK
(dBμV/m)
N/A
Limit-QP
(dBμV/m)
40.00
Limit-AV
(dBμV/m)
N/A
908.949
30.07
N/A
N/A
N/A
N/A
1931.500
41.83
N/A
28.48
74.0
2725.400
44.81
N/A
39.08
4539.400
46.01
N/A
6358.800
50.50
N/A
Antenna
Verdict
Vertical
PASS
N/A
Vertical
N/A
N/A
54.0
Vertical
PASS
74.0
N/A
54.0
Vertical
PASS
32.37
74.0
N/A
54.0
Vertical
PASS
45.09
74.0
N/A
54.0
Vertical
PASS
(908.4MHz, Antenna Vertical, 30MHz to 10GHz)
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 18 0f 23
REPORT No.:SZ17110127W01
Fre.
(MHz)
36.070
Pk
(dBμV/m)
25.49
QP
(dBμV/m)
N/A
AV
(dBμV/m)
N/A
Limit-PK
(dBμV/m)
N/A
Limit-QP
(dBμV/m)
40.00
Limit-AV
(dBμV/m)
N/A
Antenna
Verdict
Horizontal
PASS
916.233
46.96
N/A
N/A
N/A
N/A
N/A
Horizontal
N/A
1816.700
41.39
N/A
27.87
74.0
N/A
54.00
Horizontal
PASS
2748.390
46.39
N/A
32.52
74.0
N/A
54.00
Horizontal
PASS
4579.900
51.89
N/A
44.03
74.0
N/A
54.00
Horizontal
PASS
6412.000
48.69
N/A
40.60
74.0
N/A
54.00
Horizontal
PASS
(916MHz, Antenna Horizontal, 30MHz to 10GHz)
Fre.
(MHz)
36.070
Pk
(dBμV/m)
28.89
QP
(dBμV/m)
N/A
AV
(dBμV/m)
N/A
Limit-PK
(dBμV/m)
N/A
Limit-QP
(dBμV/m)
40.00
Limit-AV
(dBμV/m)
N/A
916.233
45.08
N/A
N/A
N/A
N/A
1829.600
42.23
N/A
27.74
74.0
2748.200
44.91
N/A
39.28
4580.000
49.99
N/A
6412.100
47.36
N/A
Antenna
Verdict
Vertical
PASS
N/A
Vertical
N/A
N/A
54.00
Vertical
PASS
74.0
N/A
54.00
Vertical
PASS
43.54
74.0
N/A
54.00
Vertical
PASS
37.08
74.0
N/A
54.00
Vertical
PASS
(916MHz, Antenna Vertical, 30MHz to 10GHz)
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 19 0f 23
REPORT No.:SZ17110127W01
Annex A Test Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for test
performed on the EUT as specified in CISPR 16-1-2:
Test items
Uncertainty
Bandwidth
±5%
Conducted Emission
±2.44dB
Radiated Emission
±2.95dB
This uncertainty represent an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 20 0f 23
REPORT No.:SZ17110127W01
Annex B Testing Laboratory Information
1. Identification of the Responsible Testing Laboratory
Company Name:
Shenzhen Morlab Communications Technology Co., Ltd.
Department:
Morlab Laboratory
Address:
FL.3, Building A, FeiYang Science Park, No.8 LongChang
Road, Block 67, BaoAn District, ShenZhen, GuangDong
Province, P. R. China
Responsible Test Lab
Manager:
Mr. Su Feng
Telephone:
+86 755 36698555
Facsimile:
+86 755 36698525
2. Identification of the Responsible Testing Location
Name:
Shenzhen Morlab Communications Technology Co., Ltd.
Morlab Laboratory
Address:
FL.3, Building A, FeiYang Science Park, No.8 LongChang
Road, Block 67, BaoAn District, ShenZhen, GuangDong
Province, P. R. China
3. Facilities and Accreditations
All measurement facilities used to collect the measurement data are located at FL.3, Building A,
FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is
constructed in conformance with the requirements of ANSI C63.10-2013 and CISPR Publication 22;
the FCC designation number is CN1192.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 21 0f 23
REPORT No.:SZ17110127W01
4. Test Equipments Utilized
4.1 Radiated Test Equipments
Equipment
Name
Serial No.
Type
Manufacturer
Cal. Date
Cal. Due
Receiver
MY54130016
N9038A
Agilent
2017.05.17
2018.05.16
Test Antenna Bi-Log
9163-519
VULB 9163
Schwarzbeck
2017.05.14
2018.05.13
Test Antenna Horn
9170C-531
BBHA9170
Schwarzbeck
2017.09.13
2018.09.12
Test Antenna Loop
1519-022
FMZB1519
Schwarzbeck
2017.03.07
2018.03.06
Test Antenna Horn
01774
BBHA 9120D
Schwarzbeck
2017.09.13
2018.09.12
Coaxial cable
(N male)
(9KHz-30MHz)
CB04
EMC04
Morlab
N/A
N/A
Coaxial cable
(N male)
(30MHz-26GHz)
CB02
EMC02
Morlab
N/A
N/A
Coaxial cable
(N male)
(30MHz-26GHz)
CB03
EMC03
Morlab
N/A
N/A
1-18GHz
pre-Amplifier
MA02
TS-PR18
Rohde&
Schwarz
2017.05.17
2018.05.16
18-26.5GHz
pre-Amplifier
MA03
TS-PR18
Rohde&
Schwarz
2017.05.17
2018.05.16
Anechoic
Chamber
N/A
9m*6m*6m
CRT
2017.11.19
2020.11.18
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 22 0f 23
REPORT No.:SZ17110127W01
4.2 Conducted Emission Test Equipments
Equipment Name
Receiver
Serial No.
MY56400093
Type
N9038A
Manufacturer
KEYSIGHT
Schwarzbeck
Cal. Date
2017.07.13
2017.05.17
Cal. Due
2018.07.12
2018.05.16
LISN
812744
NSLK 8127
Pulse Limiter
(20dB)
9391
VTSD
9561-D
Schwarzbeck
2017.05.17
2018.05.16
Coaxial cable(BNC)
(30MHz-26GHz)
CB01
EMC01
Morlab
N/A
N/A
END OF REPORT
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 23 0f 23
Download: FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Mirror Download [FCC.gov]FC100 Fan Control Test Report CE RF Golden Mark (HK) Limited
Document ID3820563
Application IDd7PPhwTJC1FEz95lYaSAqw==
Document DescriptionSZ17110127W01_15.249 fcc
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize59.7kB (746312 bits)
Date Submitted2018-04-18 00:00:00
Date Available2018-04-18 00:00:00
Creation Date2018-04-18 09:03:45
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2018-04-18 09:05:44
Document TitleCE RF TEST REPORT
Document CreatorAcrobat PDFMaker 9.1 Word 版
Document Author: X

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : X
Company                         : Microsoft
Create Date                     : 2018:04:18 09:03:45+08:00
KSO Product Build Ver           : 2052-9.1.0.4855
Modify Date                     : 2018:04:18 09:05:44+08:00
Source Modified                 : D:20180418010302
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2018:04:18 09:05:44+08:00
Creator Tool                    : Acrobat PDFMaker 9.1 Word 版
Document ID                     : uuid:496a22b7-ced1-42c9-b7cb-1d6563982a74
Instance ID                     : uuid:2f3dfae0-4f0e-4a30-b172-c3cee32ffe80
Subject                         : 14
Format                          : application/pdf
Title                           : CE RF TEST REPORT
Creator                         : X
Producer                        : Adobe PDF Library 9.0
Page Layout                     : OneColumn
Page Count                      : 23