FCC ID 2AN4V-GKU1001-2G

Siren Gateway

by Siren Care(Shanghai)information and technology company

Grantee Code: 2AN4V   Product Code: GKU10012G
Latest application date: 2019-09-05

FCC ID Device Details

FCC ID2AN4V-GKU1001-2G
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AN4V
Product CodeGKU10012G
Applicant BusinessSiren Care(Shanghai)information and technology company 🇨🇳
Related Domains siren.care
Equipment ClassSiren Gateway
Test FirmShenzhen LCS Compliance Testing Laboratory Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2019-09-05
1850.2-1909.8 MHzOriginal Equipment2019-09-05

Exhibits

DocumentTypeAvailableFile
User-ManualUsers Manual2019-09-05PDF 472.2 KB
Internal PhotosInternal Photos2019-09-05PDF 1.1 MB
External_PhotosExternal Photos2019-09-05PDF 249.5 KB
Label_and_Label_LocationID Label/Location Info2019-09-05PDF 74.4 KB
Test Setup Photos_WWANTest Setup Photos2019-09-05PDF 234.3 KB
Test_Setup_PhotosTest Setup Photos2019-09-05PDF 166.1 KB
Appendix A Test Data for BT LETest Report2019-09-05PDF 349.3 KB
LCS190724027AEA_BT LE FCCTest Report2019-09-05PDF 800.9 KB
LCS190724027AEB_GSM FCCTest Report2019-09-05PDF 2.1 MB
Agent_Authorization_Rev_Cover Letter(s)2019-09-05PDF 14.1 KB
Agent_Authorization_Rev_1Cover Letter(s)2019-09-05PDF 14.1 KB
FCC Long Term Confidentiality Request Rev4.1Cover Letter(s)2019-09-05PDF 57.6 KB
MPE Report FCCRF Exposure Info2019-09-05PDF 170 KB
Block_Diagram Metadata onlyBlock DiagramPDF 110.5 KB
Schematic Metadata onlySchematicsPDF 341.9 KB
Operation Description Metadata onlyOperational DescriptionPDF 176.8 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 223.2 KB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 11.6 KB

Application Information

Application IDpuC/RN0UddDBPn9TS7Ngpg==
Final Action Date2019-09-05
Application PurposeOriginal Equipment
Applicant FRN0026945139
ModelGKU1001-2G
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSiren Gateway
Responsible PartyXuening Shen, R&D; manager, shen.xuening@siren.care , +86 02131588663
Technical ContactSiren Care(Shanghai)information and technology com, shen.xuening@siren.care
Test FirmGavin Liang, Shenzhen LCS Compliance Testing Laboratory Ltd., gavin.liang@lcs-cert.com , 0755-82591330
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
puC/RN0UddDBPn9TS7Ngpg==2019-09-05Original Equipment
YbRCOR2GtoOYhY7fEDIJfw==2019-09-05Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1850.2-1909.8 MHz0.61240.024ppm246KGXW24E
1850.2-1909.8 MHz0.19280.026ppm247KG7W24E
2402-2480 MHz0.001200015C

Grants

TCB Grant - Application YbRCOR2GtoOYhY7fEDIJfw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 09/05/2019

Application Dated: 09/05/2019
Siren Care(Shanghai)information and technology company
Room 816,Building B,900 Yishan Rd, Shanghai,China
Shanghai, 200000
China
 
Attention: Xuening Shen , R&D manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AN4V-GKU1001-2G
Name of Grantee:  Siren Care(Shanghai)information and technology company
Equipment Class: PCS Licensed Transmitter
Notes: Siren Gateway
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.6124 0.024  PM 246KGXW
24E 1850.2  -  1909.8 0.1928 0.026  PM 247KG7W

Output power listed is EIRP power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

EAS Grant - Application YbRCOR2GtoOYhY7fEDIJfw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Siren Care(Shanghai)information and technology company
Room 816,Building B,900 Yishan Rd, Shanghai,China
Shanghai, 200000
China
  Date of Grant: 09/05/2019

Application Dated: 09/05/2019
 
Attention: Xuening Shen , R&D manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AN4V-GKU1001-2G
Name of Grantee:  Siren Care(Shanghai)information and technology company
Equipment Class: PCS Licensed Transmitter
Notes: Siren Gateway
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.6124 0.024  PM 246KGXW
24E 1850.2  -  1909.8 0.1928 0.026  PM 247KG7W

Output power listed is EIRP power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.



TCB Grant - Application puC/RN0UddDBPn9TS7Ngpg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 09/05/2019

Application Dated: 09/05/2019
Siren Care(Shanghai)information and technology company
Room 816,Building B,900 Yishan Rd, Shanghai,China
Shanghai, 200000
China
 
Attention: Xuening Shen , R&D manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AN4V-GKU1001-2G
Name of Grantee:  Siren Care(Shanghai)information and technology company
Equipment Class: Digital Transmission System
Notes: Siren Gateway
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0012  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

EAS Grant - Application puC/RN0UddDBPn9TS7Ngpg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Siren Care(Shanghai)information and technology company
Room 816,Building B,900 Yishan Rd, Shanghai,China
Shanghai, 200000
China
  Date of Grant: 09/05/2019

Application Dated: 09/05/2019
 
Attention: Xuening Shen , R&D manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AN4V-GKU1001-2G
Name of Grantee:  Siren Care(Shanghai)information and technology company
Equipment Class: Digital Transmission System
Notes: Siren Gateway
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0012  

Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.



Mail To: