FCC ID 2AN4V-GKU1001-2G
Siren Gateway
by Siren Care(Shanghai)information and technology company
Grantee Code: 2AN4V Product Code: GKU10012G
Latest application date: 2019-09-05
FCC ID Device Details
| FCC ID | 2AN4V-GKU1001-2G |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AN4V |
| Product Code | GKU10012G |
| Applicant Business | Siren Care(Shanghai)information and technology company 🇨🇳 |
| Related Domains | |
| Equipment Class | Siren Gateway |
| Test Firm | Shenzhen LCS Compliance Testing Laboratory Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2019-09-05 |
| 1850.2-1909.8 MHz | Original Equipment | 2019-09-05 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User-Manual | Users Manual | 2019-09-05 | PDF 472.2 KB |
| Internal Photos | Internal Photos | 2019-09-05 | PDF 1.1 MB |
| External_Photos | External Photos | 2019-09-05 | PDF 249.5 KB |
| Label_and_Label_Location | ID Label/Location Info | 2019-09-05 | PDF 74.4 KB |
| Test Setup Photos_WWAN | Test Setup Photos | 2019-09-05 | PDF 234.3 KB |
| Test_Setup_Photos | Test Setup Photos | 2019-09-05 | PDF 166.1 KB |
| Appendix A Test Data for BT LE | Test Report | 2019-09-05 | PDF 349.3 KB |
| LCS190724027AEA_BT LE FCC | Test Report | 2019-09-05 | PDF 800.9 KB |
| LCS190724027AEB_GSM FCC | Test Report | 2019-09-05 | PDF 2.1 MB |
| Agent_Authorization_Rev_ | Cover Letter(s) | 2019-09-05 | PDF 14.1 KB |
| Agent_Authorization_Rev_1 | Cover Letter(s) | 2019-09-05 | PDF 14.1 KB |
| FCC Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 2019-09-05 | PDF 57.6 KB |
| MPE Report FCC | RF Exposure Info | 2019-09-05 | PDF 170 KB |
| Block_Diagram Metadata only | Block Diagram | PDF 110.5 KB | |
| Schematic Metadata only | Schematics | PDF 341.9 KB | |
| Operation Description Metadata only | Operational Description | PDF 176.8 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 223.2 KB | |
| Tune up Procedure Metadata only | Parts List/Tune Up Info | PDF 11.6 KB |
Application Information
| Application ID | puC/RN0UddDBPn9TS7Ngpg== |
|---|---|
| Final Action Date | 2019-09-05 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0026945139 |
| Model | GKU1001-2G |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Siren Gateway |
| Responsible Party | Xuening Shen, R&D; manager, shen.xuening@siren.care |
| Technical Contact | Siren Care(Shanghai)information and technology com, shen.xuening@siren.care |
| Test Firm | Gavin Liang, Shenzhen LCS Compliance Testing Laboratory Ltd., gavin.liang@lcs-cert.com |
| TCB Email | certification@micomlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| puC/RN0UddDBPn9TS7Ngpg== | 2019-09-05 | Original Equipment |
| YbRCOR2GtoOYhY7fEDIJfw== | 2019-09-05 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application YbRCOR2GtoOYhY7fEDIJfw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 09/05/2019 Application Dated: 09/05/2019 |
| Siren Care(Shanghai)information and technology company |
| Room 816,Building B,900 Yishan Rd, Shanghai,China |
| Shanghai, 200000 China |
| Attention: Xuening Shen , R&D manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AN4V-GKU1001-2G |
| Name of Grantee: | Siren Care(Shanghai)information and technology company |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Siren Gateway |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.2 - 1909.8 | 0.6124 | 0.024 PM | 246KGXW | |
| 24E | 1850.2 - 1909.8 | 0.1928 | 0.026 PM | 247KG7W |
| Output power listed is EIRP power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
EAS Grant - Application YbRCOR2GtoOYhY7fEDIJfw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Siren Care(Shanghai)information and technology company Room 816,Building B,900 Yishan Rd, Shanghai,China Shanghai, 200000 China |
Date of Grant: 09/05/2019 Application Dated: 09/05/2019 |
| Attention: Xuening Shen , R&D manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AN4V-GKU1001-2G |
| Name of Grantee: | Siren Care(Shanghai)information and technology company |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Siren Gateway |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.2 - 1909.8 | 0.6124 | 0.024 PM | 246KGXW | |
| 24E | 1850.2 - 1909.8 | 0.1928 | 0.026 PM | 247KG7W |
| Output power listed is EIRP power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 09/05/2019 Application Dated: 09/05/2019 |
| Siren Care(Shanghai)information and technology company |
| Room 816,Building B,900 Yishan Rd, Shanghai,China |
| Shanghai, 200000 China |
| Attention: Xuening Shen , R&D manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AN4V-GKU1001-2G |
| Name of Grantee: | Siren Care(Shanghai)information and technology company |
| Equipment Class: | Digital Transmission System |
| Notes: | Siren Gateway |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0012 |
| Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
EAS Grant - Application puC/RN0UddDBPn9TS7Ngpg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Siren Care(Shanghai)information and technology company Room 816,Building B,900 Yishan Rd, Shanghai,China Shanghai, 200000 China |
Date of Grant: 09/05/2019 Application Dated: 09/05/2019 |
| Attention: Xuening Shen , R&D manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AN4V-GKU1001-2G |
| Name of Grantee: | Siren Care(Shanghai)information and technology company |
| Equipment Class: | Digital Transmission System |
| Notes: | Siren Gateway |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0012 |
| Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| Mail To: |