CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.

SHENZHEN TORRAS TECHNOLOGY CO.,LTD. Wireless Charger

Page 1 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 2 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 3 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 4 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 5 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 6 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 7 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 8 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 9 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 10 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 11 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 12 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 13 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 14 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 15 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 16 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 17 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 18 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 19 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 20 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 21 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 22 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 23 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 24 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 25 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 26 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Page 27 of CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.

TEST REPORT
FCC ID: 2AN4YCDRZ25
Product: Wireless Charger
Model No.: CDRZ25
Additional Model: CDRZ26
Trade Mark: TORRAS
Report No.: TCT171218E013
Issued Date: Jan. 03, 2018
Issued for:
SHENZHEN TORRAS TECHNOLOGY CO., LTD.
17F, BLOCK C, ZHANTAO TECHNOLOGY BUILDING, MINZHI ROAD,
LONGHUA DISTRICT, SHENZHEN, China
Issued By:
Shenzhen Tongce Testing Lab.
1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District,
Shenzhen, Guangdong, China
TEL: +86-755-27673339
FAX: +86-755-27673332
Note: This report shall not be reproduced except in full, without the written approval of Shenzhen Tongce Testing Lab.
This document may be altered or revised by Shenzhen Tongce Testing Lab. personnel only, and shall be noted in
the revision section of the document. The test results in the report only apply to the tested sample.
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
TABLE OF CONTENTS
1. Test Certification ...................................................................................... 3
2. Test Result Summary ............................................................................... 4
3. EUT Description ........................................................................................ 5
4. Genera Information ................................................................................... 6
4.1. Test environment and mode ................................................................................ 6
4.2. Description of Support Units ............................................................................... 6
5. Facilities and Accreditations ................................................................... 7
5.1. Facilities ................................................................................................................ 7
5.2. Location ................................................................................................................. 7
5.3. Measurement Uncertainty .................................................................................... 7
6. Test Results and Measurement Data....................................................... 8
6.1. Antenna requirement ............................................................................................ 8
6.2. Conducted Emission ............................................................................................ 9
6.3. Radiated Spurious Emission Measurement ..................................................... 13
Appendix A: Photographs of Test Setup
Appendix B: Photographs of EUT
Page 2 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
1. Test Certification
Product:
Wireless Charger
Model No.:
CDRZ25
Additional
Model No.:
CDRZ26
Trade Mark:
TORRAS
Applicant:
SHENZHEN TORRAS TECHNOLOGY CO., LTD.
Address:
17F, BLOCK C, ZHANTAO TECHNOLOGY BUILDING, MINZHI
ROAD, LONGHUA DISTRICT, SHENZHEN, China
Manufacturer: SHENZHEN TORRAS TECHNOLOGY CO., LTD.
Address:
17F, BLOCK C, ZHANTAO TECHNOLOGY BUILDING, MINZHI
ROAD, LONGHUA DISTRICT, SHENZHEN, China
Date of Test:
Dec. 19, 2017 - Jan. 02, 2018
Applicable
Standards:
FCC CFR Title 47 Part 15 Subpart C
The above equipment has been tested by Shenzhen Tongce Testing Lab. and found
compliance with the requirements set forth in the technical standards mentioned above. The
results of testing in this report apply only to the product/system, which was tested. Other
similar equipment will not necessarily produce the same results due to production tolerance
and measurement uncertainties.
Tested By:
Date:
Jan. 02, 2018
Date:
Jan. 03, 2018
Date:
Jan. 03, 2018
Brews Xu
Reviewed By:
Joe Zhou
Approved By:
Tomsin
Page 3 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
2.
Test Result Summary
Requirement
CFR 47 Section
Result
Antenna requirement
§15.203
PASS
AC Power Line Conducted
Emission
§15.207
PASS
Spurious Emission
§15.209(a)(f)
PASS
Note:
1. PASS: Test item meets the requirement.
2. Fail: Test item does not meet the requirement.
3. N/A: Test case does not apply to the test object.
4. The test result judgment is decided by the limit of test standard.
Page 4 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
3. EUT Description
Product:
Wireless Charger
Model No.:
CDRZ25
Additional Model No.:
CDRZ26
Trade Mark:
TORRAS
Operation Frequency:
110-205KHz
Number of Channel:
20 Channels
Modulation
Technology:
MSK
Antenna Type:
Inductive loop coil Antenna
Antenna Gain:
0dBi
Remark:
All models above are identical in interior structure, electrical
circuits and components, and just model names are different
for the marketing requirement.
Operation Frequency each of channel
Channel
Frequency
(MHz)
Channel
Frequency
(MHz)
Channel
Frequency
(MHz)
Channel
Frequency
(MHz)
0.110
0.115
0.120
0.125
0.130
10
0.135
0.140
0.145
0.150
0.155
11
12
13
14
15
0.160
0.165
0.170
0.175
0.180
16
17
18
19
20
0.185
0.190
0.195
0.200
0.205
Page 5 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
4. Genera Information
4.1. Test environment and mode
Operating Environment:
Temperature:
25.0 C
Humidity:
56 % RH
Atmospheric Pressure:
1010 mbar
Test Mode:
Engineering mode:
Keep the EUT in continuous transmitting
by select channel and modulations(The
value of duty cycle is 98.46%) with
Fully-charged battery.
The sample was placed (0.1m below 1GHz, 1.5m above 1GHz) above the ground
plane of 3m chamber. Measurements in both horizontal and vertical polarities were
performed. During the test, each emission was maximized by: having the EUT
continuously working, investigated all operating modes, rotated about all 3 axis (X, Y &
Z) and considered typical configuration to obtain worst position, manipulating
interconnecting cables, rotating the turntable, varying antenna height from 1m to 4m in
both horizontal and vertical polarizations. The emissions worst-case are shown in Test
Results of the following pages.
4.2. Description of Support Units
The EUT has been tested as an independent unit together with other necessary
accessories or support units. The following support units or accessories were used to
form a representative test configuration during the tests.
Equipment
Model No.
Serial No.
FCC ID
Trade Name
Adapter
HW-059200CHQ
K68247F5H01734
HUAWEI
Mobilephone
honor 9
5JPDU17610004560
honor
Note:
1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test.
2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended
use.
3. For conducted measurements (Output Power, 6dB Emission Bandwidth, Power Spectral Density, Spurious
Emissions), the antenna of EUT is connected to the test equipment via temporary antenna connector, the
antenna connector is soldered on the antenna port of EUT, and the temporary antenna connector is listed in the
Test Instruments.
Page 6 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
5.
Facilities and Accreditations
5.1. Facilities
The test facility is recognized, certified, or accredited by the following organizations:
● FCC - Registration No.: 645098
Shenzhen Tongce Testing Lab
The 3m Semi-anechoic chamber has been registered and fully described in a report
with the (FCC) Federal Communications Commission. The acceptance letter from the
FCC is maintained in our files.
● IC - Registration No.: 10668A-1
The 3m Semi-anechoic chamber of Shenzhen TCT Testing Technology Co., Ltd. has
been registered by Certification and Engineering Bureau of Industry Canada for radio
equipment testing
5.2. Location
Shenzhen Tongce Testing Lab
Address: 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District,
Shenzhen, Guangdong, China
TEL: +86-755-27673339
5.3. Measurement Uncertainty
The reported uncertainty of measurement y ± U, where expended uncertainty U is based
on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of
confidence of approximately 95 %.
No.
Item
MU
Conducted Emission
±2.56dB
RF power, conducted
±0.12dB
Spurious emissions, conducted
±0.11dB
All emissions, radiated(<1G)
±3.92dB
All emissions, radiated(>1G)
±4.28dB
Temperature
±0.1°C
Humidity
±1.0%
Page 7 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
6.
Test Results and Measurement Data
6.1. Antenna requirement
Standard requirement:
FCC Part15 C Section 15.203
15.203 requirement:
An intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a
permanently attached antenna or of an antenna that uses a unique coupling to the
intentional radiator, the manufacturer may design the unit so that a broken antenna
can be replaced by the user, but the use of a standard antenna jack or electrical
connector is prohibited.
E.U.T Antenna:
The antenna is inductive loop coil antenna which permanently attached, and the best
case gain of the antenna is 0dBi.
Antenna
Page 8 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
6.2. Conducted Emission
6.2.1. Test Specification
Test Requirement:
FCC Part15 C Section 15.207
Test Method:
ANSI C63.10:2013
Frequency Range:
150 kHz to 30 MHz
Receiver setup:
RBW=9 kHz, VBW=30 kHz, Sweep time=auto
Limits:
Frequency range
(MHz)
0.15-0.5
0.5-5
5-30
Limit (dBuV)
Quasi-peak
Average
66 to 56*
56 to 46*
56
46
60
50
Test Setup:
Test Mode:
Charging + Transmitting Mode
Test Procedure:
1. The E.U.T is connected to an adapter through a line
impedance stabilization network (L.I.S.N.). This
provides a 50ohm/50uH coupling impedance for the
measuring equipment.
2. The peripheral devices are also connected to the main
power through a LISN that provides a 50ohm/50uH
coupling impedance with 50ohm termination. (Please
refer to the block diagram of the test setup and
photographs).
3. Both sides of A.C. line are checked for maximum
conducted interference. In order to find the maximum
emission, the relative positions of equipment and all of
the interface cables must be changed according to
ANSI C63.10: 2013 on conducted measurement.
Test Result:
PASS
Page 9 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
6.2.2. Test Instruments
Conducted Emission Shielding Room Test Site (843)
Equipment
Manufacturer
Model
Serial Number Calibration Due
Test Receiver
R&S
ESPI
101401
Jun. 12, 2018
LISN
Schwarzbeck
NSLK 8126
8126453
Sep. 27, 2018
Coax cable
(9KHz-30MHz)
TCT
CE-05
N/A
Sep. 27, 2018
EMI Test Software
Shurple
Technology
EZ-EMC
N/A
N/A
Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to
international system unit (SI).
Page 10 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
6.2.3. Test data
Please refer to following diagram for individual
Conducted Emission on Line Terminal of the power line (150 kHz to 30MHz)
Note:
Freq. = Emission frequency in MHz
Reading level (dBµV) = Receiver reading
Corr. Factor (dB) = Antenna factor + Cable loss
Measurement (dBµV) = Reading level (dBµV) + Corr. Factor (dB)
Limit (dBµV) = Limit stated in standard
Margin (dB) = Measurement (dBµV) – Limits (dBµV)
Q.P. =Quasi-Peak
AVG =average
* is meaning the worst frequency has been tested in the frequency range 150 kHz to 30MHz
Page 11 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
Conducted Emission on Neutral Terminal of the power line (150 kHz to 30MHz)
Note1:
Freq. = Emission frequency in MHz
Reading level (dBµV) = Receiver reading
Corr. Factor (dB) = Antenna factor + Cable loss
Measurement (dBµV) = Reading level (dBµV) + Corr. Factor (dB)
Limit (dBµV) = Limit stated in standard
Margin (dB) = Measurement (dBµV) – Limits (dBµV)
Q.P. =Quasi-Peak
AVG =average
* is meaning the worst frequency has been tested in the frequency range 150 kHz to 30MHz.
Page 12 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
6.3. Radiated Spurious Emission Measurement
6.3.1. Test Specification
Test Requirement:
FCC Part15 C Section 15.209
Test Method:
ANSI C63.10: 2013
Frequency Range:
9 kHz to 25 GHz
Measurement Distance:
3m
Antenna Polarization:
Horizontal & Vertical
Operation mode:
Refer to item 4.1
Receiver Setup:
Frequency
9kHz- 150kHz
150kHz30MHz
30MHz-1GHz
Above 1GHz
Detector
Quasi-peak
Quasi-peak
RBW
200Hz
9kHz
VBW
1kHz
30kHz
Remark
Quasi-peak Value
Quasi-peak Value
Quasi-peak
Peak
Peak
100KHz
1MHz
1MHz
300KHz
3MHz
10Hz
Quasi-peak Value
Peak Value
Average Value
Frequency
Limit:
0.009-0.490
0.490-1.705
1.705-30
30-88
88-216
216-960
Above 960
Field Strength
(microvolts/meter)
2400/F(KHz)
24000/F(KHz)
30
100
150
200
500
Frequency
Field Strength
(microvolts/meter)
Above 1GHz
500
5000
Measurement
Distance (meters)
300
30
30
Measurement
Distance
(meters)
Detector
Average
Peak
For radiated emissions below 30MHz
Test setup:
30MHz to 1GHz
Page 13 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
Above 1GHz
Test Procedure:
1. For the radiated emission test below 1GHz:
The EUT was placed on a turntable with 0.8 meter
above ground. The EUT was set 3 meters from the
interference receiving antenna, which was mounted
on the top of a variable height antenna tower. The
EUT was arranged to its worst case and then tune
the antenna tower (from 1 m to 4 m) and turntable
(from 0 degree to 360 degrees) to find the maximum
reading. A pre-amp and a high PASS filter are used
for the test in order to get better signal level.
For the radiated emission test above 1GHz:
Place the measurement antenna on a turntable with
1.5 meter above ground, which is away from each
area of the EUT determined to be a source of
emissions at the specified measurement distance,
while keeping the measurement antenna aimed at
the source of emissions at each frequency of
significant emissions, with polarization oriented for
maximum response. The measurement antenna
may have to be higher or lower than the EUT,
depending on the radiation pattern of the emission
and staying aimed at the emission source for
receiving the maximum signal. The final
Page 14 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
Test mode:
measurement antenna elevation shall be that which
maximizes the emissions. The measurement
antenna elevation for maximum emissions shall be
restricted to a range of heights of from 1 m to 4 m
above the ground or reference ground plane.
2. Corrected Reading: Antenna Factor + Cable Loss +
Read Level - Preamp Factor = Level
3. For measurement below 1GHz, If the emission level
of the EUT measured by the peak detector is 3 dB
lower than the applicable limit, the peak emission
level will be reported. Otherwise, the emission
measurement will be repeated using the quasi-peak
detector and reported.
4. Use the following spectrum analyzer settings:
(1) Span shall wide enough to fully capture the
emission being measured;
(2) Set RBW=100 kHz for f < 1 GHz; VBW ≥
RBW;
Sweep = auto; Detector function = peak; Trace =
max hold;
(3) Set RBW = 1 MHz, VBW= 3MHz for f  1 GHz
for peak measurement.
For average measurement: VBW = 10 Hz, when
duty cycle is no less than 98 percent. VBW ≥1/T,
when duty cycle is less than 98 percent where T is
the minimum transmission duration over which the
transmitter is on and is transmitting at its maximum
power control level for the tested mode of operation.
Refer to section 4.1 for details
Test results:
PASS
Page 15 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
6.3.2. Test Instruments
Radiated Emission Test Site (966)
Name of
Equipment
Manufacturer
Model
Serial
Number
Calibration Due
Test Receiver
ROHDE&SCHW
ARZ
ESVD
100008
Sep. 27, 2018
Spectrum Analyzer
ROHDE&SCHW
ARZ
FSQ
200061
Sep. 27, 2018
Pre-amplifier
EM Electronics
Corporation
CO.,LTD
EM30265
07032613
Sep. 27, 2018
Pre-amplifier
HP
8447D
2727A05017
Sep. 27, 2018
Loop antenna
ZHINAN
ZN30900A
12024
Sep. 27, 2018
Broadband Antenna
Schwarzbeck
VULB9163
340
Sep. 27, 2018
Horn Antenna
Schwarzbeck
BBHA 9120D
631
Sep. 27, 2018
Horn Antenna
Schwarzbeck
BBH 9170
582
Jun. 07, 2018
Antenna Mast
Keleto
CC-A-4M
N/A
N/A
Coax cable
(9KHz-1GHz)
TCT
RE-low-01
N/A
Sep. 27, 2018
Coax cable
(9KHz-40GHz)
TCT
RE-high-02
N/A
Sep. 27, 2018
Coax cable
(9KHz-1GHz)
TCT
RE-low-03
N/A
Sep. 27, 2018
Coax cable
(9KHz-40GHz)
TCT
RE-high-04
N/A
Sep. 27, 2018
EMI Test Software
Shurple
Technology
EZ-EMC
N/A
N/A
Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to
international system unit (SI).
Page 16 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
6.3.3. Test Data
Please refer to following diagram for individual
9KHz-30MHz
9KHz-150KHz:
Page 17 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
150KHz-30MHz:
Page 18 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
30MHz-1GHz
Horizontal:
Page 19 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
Vertical:
Note:
Emission Level=Peak Reading + Correction Factor; Correction Factor= Antenna Factor + Cable loss – Pre-amplifier
Page 20 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
Appendix A: Photographs of Test Setup
Product: Wireless Charger
Model: CDRZ25
Radiated Emission
Page 21 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
Conducted Emission
Page 22 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
Appendix B: Photographs of EUT
Product: Wireless Charger
Model: CDRZ25
External Photos
Page 23 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
Page 24 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
Page 25 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
Product: Wireless Charger
Model: CDRZ25
Internal Photos
Page 26 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Report No.: TCT171218E013
*****END OF REPORT*****
Page 27 of 27
Hotline: 400-6611-140
Tel: 86-755-27673339
Fax: 86-755-27673332
http://www.tct-lab.com
Download: CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Mirror Download [FCC.gov]CDRZ25 Wireless Charger Test Report CE EMC SHENZHEN TORRAS TECHNOLOGY CO.,LTD.
Document ID3706296
Application IDZIHxOw5vAu0EWnriT0Hnjw==
Document DescriptionTest Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize146.02kB (1825210 bits)
Date Submitted2018-01-09 00:00:00
Date Available2018-01-09 00:00:00
Creation Date2018-01-09 07:14:51
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2018-01-09 07:14:51
Document TitleCE EMC TEST REPORT
Document CreatorMicrosoft® Office Word 2007
Document Author: Harris

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 27
Language                        : zh-CN
Tagged PDF                      : Yes
Title                           : CE EMC TEST REPORT
Author                          : Harris
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2018:01:09 07:14:51
Modify Date                     : 2018:01:09 07:14:51
Producer                        : Microsoft® Office Word 2007