FCC ID 2ANPBRMSLP4-G2

Renogy ONE M1

by RNG International Inc.

Grantee Code: 2ANPB   Product Code: RMSLP4G2
Latest application date: 2022-06-16

FCC ID Device Details

FCC ID2ANPBRMSLP4-G2
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ANPB
Product CodeRMSLP4G2
Applicant BusinessRNG International Inc. 🇺🇸
Related Domains renogy.com
Equipment ClassRenogy ONE M1
Test FirmKSIGN (Guangdong) Testing Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2022-06-16

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2022-06-16PDF 1.6 MB
Int photosInternal Photos2022-06-16PDF 5.1 MB
Internal photosInternal Photos2022-06-16PDF 1.3 MB
External photosExternal Photos2022-06-16PDF 2.1 MB
LabelID Label/Location Info2022-06-16PDF 1.3 MB
Test PhotosTest Setup Photos2022-06-16PDF 403.9 KB
Test ReportTest Report2022-06-16PDF 5.9 MB
FCC Short & Long Term Confidentiality RequestCover Letter(s)2022-06-16PDF 102.5 KB
Letter of AuthorizationCover Letter(s)2022-06-16PDF 150.6 KB
BLOCK Metadata onlyBlock DiagramPDF 57.5 KB
SCH Metadata onlySchematicsPDF 5.5 MB
Operation Description Metadata onlyOperational DescriptionPDF 180.9 KB

Application Information

Application IDtbzmXZRsh1pmZXO5pumJEw==
Final Action Date2022-06-16
Application PurposeOriginal Equipment
Applicant FRN0026824391
ModelRMSLP4-G2
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionRenogy ONE M1
Responsible Partyjason jiang, jason.jiang@renogy.com , 9095173598
Technical ContactRNG International Inc., jason.jiang@renogy.com
Test FirmNeil Wan, KSIGN (Guangdong) Testing Co., Ltd., info@gdksign.cn , +(86) 0755-2985 2678
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
tbzmXZRsh1pmZXO5pumJEw==2022-06-16Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.0014915C
2412-2462 MHz0.0048515C

Grants

TCB Grant - Application tbzmXZRsh1pmZXO5pumJEw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 06/16/2022

Application Dated: 06/16/2022
RNG International Inc.
5050 S Archibald Ave
Ontario, CA 91762
 
Attention: jason jiang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ANPBRMSLP4-G2
Name of Grantee:  RNG International Inc.
Equipment Class: Digital Transmission System
Notes: Renogy ONE M1
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00149  
15C 2412.0  -  2462.0 0.00485  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

EAS Grant - Application tbzmXZRsh1pmZXO5pumJEw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

RNG International Inc.
5050 S Archibald Ave
Ontario, CA 91762
United States
  Date of Grant: 06/16/2022

Application Dated: 06/16/2022
 
Attention: jason jiang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ANPBRMSLP4-G2
Name of Grantee:  RNG International Inc.
Equipment Class: Digital Transmission System
Notes: Renogy ONE M1
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00149  
15C 2412.0  -  2462.0 0.00485  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.