FCC ID 2ANUG-PBXV2-5-USA

Connected Pillbox

by TowerView Health, Inc.

Grantee Code: 2ANUG   Product Code: PBXV25USA
Latest application date: 2018-01-19

FCC ID Device Details

FCC ID2ANUG-PBXV2-5-USA
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2ANUG
Product CodePBXV25USA
Applicant BusinessTowerView Health, Inc. 🇺🇸
Related Domains towerviewhealth.com
Equipment ClassConnected Pillbox
Test FirmIntertekTesting Services NA Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2018-01-19
2402-2480 MHzOriginal Equipment2018-01-19

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2018-01-19PDF 119.1 KB
Users manualUsers Manual2018-01-19PDF 119.1 KB
Internal photosInternal Photos2018-01-19PDF 1.7 MB
External photosExternal Photos2018-01-19PDF 334.8 KB
Label and location infoID Label/Location Info2018-01-19PDF 737.1 KB
Label artwork and location infoID Label/Location Info2018-01-19PDF 737.1 KB
Test setup photosTest Setup Photos2018-01-19PDF 200.7 KB
SAR Test ReportRF Exposure Info2018-01-19PDF 1.5 MB
SAR test reportRF Exposure Info2018-01-19PDF 1.5 MB
Test Report 2Test Report2018-01-19PDF 5.8 MB
Test Report LTE radiated spurious EmissionsTest Report2018-01-19PDF 361.6 KB
Test Report LTE radiated spurious emissionsTest Report2018-01-19PDF 361.6 KB
Test Report Wi-Fi part 1Test Report2018-01-19PDF 3.7 MB
Test Report Wi-Fi part 2Test Report2018-01-19PDF 5.8 MB
Test Report Wi-Fi part 3Test Report2018-01-19PDF 4 MB
Test report 1Test Report2018-01-19PDF 4.2 MB
Test report BLETest Report2018-01-19PDF 3.8 MB
Confidentiality requestCover Letter(s)2018-01-19PDF 30.2 KB
Letter of agencyCover Letter(s)2018-01-19PDF 297.2 KB
Block diagram Metadata onlyBlock DiagramPDF 41.5 KB
Schematics Metadata onlySchematicsPDF 2.3 MB
Operational description Metadata onlyOperational DescriptionPDF 160.9 KB
Operational description and antenna info Metadata onlyOperational DescriptionPDF 293.9 KB
Operational description and antenna spec Metadata onlyOperational DescriptionPDF 293.9 KB

Application Information

Application IDWfFj2Us5YYB55WNNCs7C8A==
Final Action Date2018-01-19
Application PurposeOriginal Equipment
Applicant FRN0026845453
ModelPBXV2-5-USA
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionConnected Pillbox
Responsible PartyAnkur Aggarwal, Co-Founder/CTO, ankur@towerviewhealth.com , 6507769322
AgentSuresh Suresh Suresh, Intertek Testing Services, surech.kondapalli@intertek.com , 6504632900
Technical ContactHareesh Ganesan, TowerView Health, Inc., hareesh@towerviewhealth.com , (650) 776-9322
Non-Technical ContactRahul Jain, TowerView Health, Inc., ankur@towerviewhealth.com , (650) 776-9322
Test FirmCharles Parker, IntertekTesting Services NA Inc., charles.parker@intertek.com , 650-463-2900
TCB EmailTCB_Admin@intertek.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is Peak conducted. The antenna(s) used for this transmitter must not be co-located with any other antenna or transmitter except as described in this filing or in accordance with FCC multi-transmitter product procedures. Only those antennas were tested or similar antennas having the same or less gain may be used with these transmitters. SAR tested as described in this filing. The highest reported SAR for body-worn and extremity exposure conditions are 0.69 W/kg and 0.54 W/kg, respectively. The device supports 802.11b, 802.11g and 802.11n with 20 MHz and 40 MHz bandwidth mode. The device contains LTE module operating in bands 4 and 13.

Applications

Application IDDatePurpose
WfFj2Us5YYB55WNNCs7C8A==2018-01-19Original Equipment
NEUYWtbv81jxSAagL8HG1w==2018-01-19Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.017500015CCC
2402-2480 MHz0.024815CCC
2412-2462 MHz0.026215CCC
2422-2452 MHz0.018415CCC

Grants

TCB Grant - Application WfFj2Us5YYB55WNNCs7C8A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Intertek Testing Services NA, Inc.
70 Codman Hill Road
Boxborough, MA 01719
Date of Grant: 01/19/2018

Application Dated: 01/19/2018
TowerView Health, Inc.
STE 2500
2001 Market Street
Philadelphia, PA 19103
 
Attention: Ankur Aggarwal , Co-Founder/CTO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ANUG-PBXV2-5-USA
Name of Grantee:  TowerView Health, Inc.
Equipment Class: Digital Transmission System
Notes: Connected Pillbox
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0248  
CC 15C 2412.0  -  2462.0 0.0262  
CC 15C 2422.0  -  2452.0 0.0184  

Power Output listed is Peak conducted. The antenna(s) used for this transmitter must not be co-located with any other antenna or transmitter except as described in this filing or in accordance with FCC multi-transmitter product procedures. Only those antennas were tested or similar antennas having the same or less gain may be used with these transmitters.

SAR tested as described in this filing. The highest reported SAR for body-worn and extremity exposure conditions are 0.69 W/kg and 0.54 W/kg, respectively.

The device supports 802.11b, 802.11g and 802.11n with 20 MHz and 40 MHz bandwidth mode.

The device contains LTE module operating in bands 4 and 13.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application WfFj2Us5YYB55WNNCs7C8A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

TowerView Health, Inc.
STE 2500 2001 Market Street
Philadelphia, PA 19103
United States
  Date of Grant: 01/19/2018

Application Dated: 01/19/2018
 
Attention: Ankur Aggarwal , Co-Founder/CTO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ANUG-PBXV2-5-USA
Name of Grantee:  TowerView Health, Inc.
Equipment Class: Digital Transmission System
Notes: Connected Pillbox
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0248  
CC 15C 2412.0  -  2462.0 0.0262  
CC 15C 2422.0  -  2452.0 0.0184  

Power Output listed is Peak conducted. The antenna(s) used for this transmitter must not be co-located with any other antenna or transmitter except as described in this filing or in accordance with FCC multi-transmitter product procedures. Only those antennas were tested or similar antennas having the same or less gain may be used with these transmitters.

SAR tested as described in this filing. The highest reported SAR for body-worn and extremity exposure conditions are 0.69 W/kg and 0.54 W/kg, respectively.

The device supports 802.11b, 802.11g and 802.11n with 20 MHz and 40 MHz bandwidth mode.

The device contains LTE module operating in bands 4 and 13.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application NEUYWtbv81jxSAagL8HG1w==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Intertek Testing Services NA, Inc.
70 Codman Hill Road
Boxborough, MA 01719
Date of Grant: 01/19/2018

Application Dated: 01/19/2018
TowerView Health, Inc.
STE 2500
2001 Market Street
Philadelphia, PA 19103
 
Attention: Ankur Aggarwal , Co-Founder/CTO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ANUG-PBXV2-5-USA
Name of Grantee:  TowerView Health, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Connected Pillbox
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0175  

Power Output listed is Peak conducted. The antenna(s) used for this transmitter must not be co-located with any other antenna or transmitter except as described in this filing or in accordance with FCC multi-transmitter product procedures. Only those antennas were tested or similar antennas having the same or less gain may be used with these transmitters.

SAR tested as described in this filing. The highest reported SAR for body-worn and extremity exposure conditions are 0.69 W/kg and 0.54 W/kg, respectively.

The device contains LTE module operating on bands 4 and 13.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application NEUYWtbv81jxSAagL8HG1w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

TowerView Health, Inc.
STE 2500 2001 Market Street
Philadelphia, PA 19103
United States
  Date of Grant: 01/19/2018

Application Dated: 01/19/2018
 
Attention: Ankur Aggarwal , Co-Founder/CTO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2ANUG-PBXV2-5-USA
Name of Grantee:  TowerView Health, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Connected Pillbox
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0175  

Power Output listed is Peak conducted. The antenna(s) used for this transmitter must not be co-located with any other antenna or transmitter except as described in this filing or in accordance with FCC multi-transmitter product procedures. Only those antennas were tested or similar antennas having the same or less gain may be used with these transmitters.

SAR tested as described in this filing. The highest reported SAR for body-worn and extremity exposure conditions are 0.69 W/kg and 0.54 W/kg, respectively.

The device contains LTE module operating on bands 4 and 13.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: