FCC ID 2ANY8-CREDO-CB
Cardiopulmonary Resuscitation Assistance Product
by CREDO
Grantee Code: 2ANY8 Product Code: CREDOCB
Latest application date: 2021-01-22
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2021-01-22 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2021-07-21 | PDF 2 MB |
| Internal Photos | Internal Photos | 2021-07-21 | PDF 175.7 KB |
| External Photos | External Photos | 2021-07-21 | PDF 123.8 KB |
| Label Information | ID Label/Location Info | 2021-01-22 | PDF 157 KB |
| Test Setup Photos | Test Setup Photos | 2021-07-21 | PDF 769.4 KB |
| Test Report | Test Report | 2021-01-22 | PDF 2.3 MB |
| Agent Authorization Letter | Cover Letter(s) | 2021-01-22 | PDF 292.4 KB |
| Applicant Declaration Letter | Cover Letter(s) | 2021-01-22 | PDF 110.9 KB |
| Confidentiality Request | Cover Letter(s) | 2021-01-22 | PDF 20.5 KB |
| RF Exposure | RF Exposure Info | 2021-01-22 | PDF 168 KB |
| Block Diagram Metadata only | Block Diagram | PDF 51.9 KB | |
| Schematics Metadata only | Schematics | PDF 96.1 KB | |
| Operational Description Metadata only | Operational Description | PDF 31.4 KB |
Application Information
| Application ID | CCIjsaD2SXoxTQZoasz8ng== |
|---|---|
| Final Action Date | 2021-01-22 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0026912667 |
| Model | CREDO-CB |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Cardiopulmonary Resuscitation Assistance Product |
| Responsible Party | Ji Hyo wang, CMO, wangjihyo@gmail.com |
| Technical Contact | Julia Choi, SGS Korea Co., Ltd, kr.gpq@sgs.com |
| Non-Technical Contact | Becky Kim, SGS Korea Co., Ltd, becky.kim@sgs.com |
| Test Firm | Park Heejin, SGS Korea Co., Ltd, heejin.park@sgs.com |
| TCB Email | uscts.tcb@sgs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 07/21/2021 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is conducted |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| CCIjsaD2SXoxTQZoasz8ng== | 2021-01-22 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2402-2480 MHz | 0.0002000 | 15C |
Grants
TCB Grant - Application CCIjsaD2SXoxTQZoasz8ng==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 01/22/2021 Application Dated: 01/22/2021 |
| CREDO |
| #401 ,Medical instrument venture center,1 |
| Yeonsedae-gil, Heung-eop-myeon |
| Wonju-si, 26493 South Korea |
| Attention: Ji Hyo wang , CMO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ANY8-CREDO-CB |
| Name of Grantee: | CREDO |
| Equipment Class: | Digital Transmission System |
| Notes: | Cardiopulmonary Resuscitation Assistance Product |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0002 |
| Power output listed is conducted |
EAS Grant - Application CCIjsaD2SXoxTQZoasz8ng==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
CREDO #401 ,Medical instrument venture center,1 Yeonsedae-gil, Heung-eop-myeon Wonju-si, 26493 South Korea |
Date of Grant: 01/22/2021 Application Dated: 01/22/2021 |
| Attention: Ji Hyo wang , CMO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2ANY8-CREDO-CB |
| Name of Grantee: | CREDO |
| Equipment Class: | Digital Transmission System |
| Notes: | Cardiopulmonary Resuscitation Assistance Product |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0002 |
| Power output listed is conducted |
| Mail To: |