K536 Smart Phone Test Report Epik One America Corporation

Epik One America Corporation Smart Phone

Page 1 of K536 Smart Phone Test Report  Epik One America Corporation
Page 2 of K536 Smart Phone Test Report  Epik One America Corporation
Page 3 of K536 Smart Phone Test Report  Epik One America Corporation
Page 4 of K536 Smart Phone Test Report  Epik One America Corporation
Page 5 of K536 Smart Phone Test Report  Epik One America Corporation
Page 6 of K536 Smart Phone Test Report  Epik One America Corporation
Page 7 of K536 Smart Phone Test Report  Epik One America Corporation
Page 8 of K536 Smart Phone Test Report  Epik One America Corporation
Page 9 of K536 Smart Phone Test Report  Epik One America Corporation
Page 10 of K536 Smart Phone Test Report  Epik One America Corporation
Page 11 of K536 Smart Phone Test Report  Epik One America Corporation
Page 12 of K536 Smart Phone Test Report  Epik One America Corporation
Page 13 of K536 Smart Phone Test Report  Epik One America Corporation
Page 14 of K536 Smart Phone Test Report  Epik One America Corporation
Page 15 of K536 Smart Phone Test Report  Epik One America Corporation
Page 16 of K536 Smart Phone Test Report  Epik One America Corporation
Page 17 of K536 Smart Phone Test Report  Epik One America Corporation
Page 18 of K536 Smart Phone Test Report  Epik One America Corporation
Page 19 of K536 Smart Phone Test Report  Epik One America Corporation
Page 20 of K536 Smart Phone Test Report  Epik One America Corporation
Page 21 of K536 Smart Phone Test Report  Epik One America Corporation
Page 22 of K536 Smart Phone Test Report  Epik One America Corporation
Page 23 of K536 Smart Phone Test Report  Epik One America Corporation
Page 24 of K536 Smart Phone Test Report  Epik One America Corporation
Page 25 of K536 Smart Phone Test Report  Epik One America Corporation
Page 26 of K536 Smart Phone Test Report  Epik One America Corporation
Page 27 of K536 Smart Phone Test Report  Epik One America Corporation
Page 28 of K536 Smart Phone Test Report  Epik One America Corporation
Page 29 of K536 Smart Phone Test Report  Epik One America Corporation
Page 30 of K536 Smart Phone Test Report  Epik One America Corporation
Page 31 of K536 Smart Phone Test Report  Epik One America Corporation
Page 32 of K536 Smart Phone Test Report  Epik One America Corporation
Page 33 of K536 Smart Phone Test Report  Epik One America Corporation
Page 34 of K536 Smart Phone Test Report  Epik One America Corporation
Page 35 of K536 Smart Phone Test Report  Epik One America Corporation
Page 36 of K536 Smart Phone Test Report  Epik One America Corporation
Page 37 of K536 Smart Phone Test Report  Epik One America Corporation
Page 38 of K536 Smart Phone Test Report  Epik One America Corporation
Page 39 of K536 Smart Phone Test Report  Epik One America Corporation
Page 40 of K536 Smart Phone Test Report  Epik One America Corporation
Page 41 of K536 Smart Phone Test Report  Epik One America Corporation
Page 42 of K536 Smart Phone Test Report  Epik One America Corporation
Page 43 of K536 Smart Phone Test Report  Epik One America Corporation
Page 44 of K536 Smart Phone Test Report  Epik One America Corporation
Page 45 of K536 Smart Phone Test Report  Epik One America Corporation
Page 46 of K536 Smart Phone Test Report  Epik One America Corporation
Page 47 of K536 Smart Phone Test Report  Epik One America Corporation
Page 48 of K536 Smart Phone Test Report  Epik One America Corporation
Page 49 of K536 Smart Phone Test Report  Epik One America Corporation
Page 50 of K536 Smart Phone Test Report  Epik One America Corporation
Page 51 of K536 Smart Phone Test Report  Epik One America Corporation
Page 52 of K536 Smart Phone Test Report  Epik One America Corporation
Page 53 of K536 Smart Phone Test Report  Epik One America Corporation
Page 54 of K536 Smart Phone Test Report  Epik One America Corporation
Page 55 of K536 Smart Phone Test Report  Epik One America Corporation
Page 56 of K536 Smart Phone Test Report  Epik One America Corporation

FCC PART 15.247
TEST REPORT
For
Epik One America Corporation
170 Ocean Lane Dr. #705, Key Biscayne, FL 33149, United States
FCC ID: 2AO6ZK536
Report Type:
Product Type:
Original Report
S mart Phone
Report Number:
Report Date:
RSZ181116001-00B
2018-12-10
Rocky Kang
Reviewed By:
RF Engineer
Prepared By:
Bay Area Compliance Laboratories Corp. (Shenzhen)
6/F., West Wing, Third Phase of Wanli Industrial
Building, Shihua Road, Futian Free Trade Zone,
Shenzhen, Guangdong, China
Tel: +86-755-33320018
Fax: +86-755-33320008
www.baclcorp.com.cn
Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any
agency of the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked
with an asterisk “*”.
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
TABLE OF CONTENTS
GENERAL INFORMATION .......................................................................................................................................4
PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4
OBJECTIVE ...................................................................................................................................................................4
RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................4
TEST METHODOLOGY ..................................................................................................................................................4
MEASUREMENT UNCERTAINTY ....................................................................................................................................5
TEST FACILITY .............................................................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6
EUT EXERCISE SOFTWARE ..........................................................................................................................................6
SPECIAL ACCESSORIES .................................................................................................................................................6
EQUIPMENT MODIFICATIONS .......................................................................................................................................6
SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................6
EXTERNAL I/O CABLE..................................................................................................................................................6
BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................7
SUMMARY OF TEST RESULTS ...............................................................................................................................8
TEST EQUIPMENT LIST ...........................................................................................................................................9
FCC§15.247 (i), §1.1307 (b) (1) &§2.1093 – RF EXPOSURE ......................................................................................11
APPLICABLE STANDARD ............................................................................................................................................11
FCC §15.203 – ANTENNA REQUIREMENT ..........................................................................................................12
APPLICABLE STANDARD ............................................................................................................................................12
ANTENNA CONNECTOR CONSTRUCTION ....................................................................................................................12
FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS .....................................................................................13
APPLICABLE STANDARD ............................................................................................................................................13
EUT SETUP ................................................................................................................................................................13
EMI TEST RECEIVER SETUP .......................................................................................................................................13
TEST PROCEDURE ......................................................................................................................................................13
CORRECTED FACTOR & MARGIN CALCULATION .......................................................................................................14
TEST RESULTS SUMMARY ..........................................................................................................................................14
TEST DATA ................................................................................................................................................................14
FCC §15.205, §15.209 & §15.247(d) – RADIATED EMISSIONS ...........................................................................17
APPLICABLE STANDARD ............................................................................................................................................17
EUT SETUP ................................................................................................................................................................17
EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP ..............................................................................................18
TEST PROCEDURE ......................................................................................................................................................18
CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................18
TEST RESULTS SUMMARY ..........................................................................................................................................18
TEST DATA ................................................................................................................................................................19
FCC §15.247(a) (1)-CHANNEL SEPARATION TEST ...........................................................................................26
APPLICABLE STANDARD ............................................................................................................................................26
TEST PROCEDURE ......................................................................................................................................................26
TEST DATA ................................................................................................................................................................26
FCC Part 15.247
Page 2 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
FCC §15.247(a) (1) – 20 dB EMISSION BANDWIDTH ..........................................................................................33
APPLICABLE STANDARD ............................................................................................................................................33
TEST PROCEDURE ......................................................................................................................................................33
TEST DATA ................................................................................................................................................................33
FCC §15.247(a) (1) (iii)-QUANTITY OF HOPPING CHANNEL TEST ...............................................................39
APPLICABLE STANDARD ............................................................................................................................................39
TEST PROCEDURE ......................................................................................................................................................39
TEST DATA ................................................................................................................................................................39
FCC §15.247(a) (1) (iii) - TIME OF OCCUPANCY (DWELL TIME) ...................................................................42
APPLICABLE STANDARD ............................................................................................................................................42
TEST PROCEDURE ......................................................................................................................................................42
TEST DATA ................................................................................................................................................................42
FCC §15.247(b) (1) - PEAK OUTPUT POWER MEASUREMENT ......................................................................49
APPLICABLE STANDARD ............................................................................................................................................49
TEST PROCEDURE ......................................................................................................................................................49
TEST DATA ................................................................................................................................................................49
FCC §15.247(d) - BAND EDGES TESTING ............................................................................................................50
APPLICABLE STANDARD ............................................................................................................................................50
TEST PROCEDURE ......................................................................................................................................................50
TEST DATA ................................................................................................................................................................50
FCC Part 15.247
Page 3 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The Epik One America Corporation’s product, model number: K536 (FCC ID: 2AO6ZK536) or the
"EUT" in this report was a Smart Phone, which was measured approximately: 151.0 mm (L) × 72.0 mm
(W) × 9.0 mm (H), rated with input voltage: DC 3.8V from rechargeable Li-ion battery or DC 5.0V from
adapter.
Adapter Information:
Model: JWS664-501000
Input: AC 100-240V, 50/60Hz, 0.2A
Output: DC 5.0V, 1000 mA
Notes: This series product models: K535 and K536 are electrically identical, the difference among them is only
model number due to marketing purpose, model K536 was selected for fully testing, the detailed information can be
referred to the declaration letter which was stated and guaranteed by the applicant.
*All measurement and test data in this report was gathered from production sample serial number: 1801830.
(Assigned by BACL, Shenzhen). The EUT supplied by the applicant was received on 2018-11-16.
Objective
This test report is prepared on behalf of Epik One America Corporation in accordance with Part 2-Subpart
J, Part 15-Subparts A and C of the Federal Communication Commissions rules.
The tests were performed in order to determine compliance with FCC Part 15, Subpart C, section 15.203,
15.205, 15.207, 15.209 and 15.247 rules.
Related Submittal(s)/Grant(s)
Part 15.247 DTS and Part 22H /24E PCE submissions with FCC ID: 2AO6ZK536.
Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.
For Radiated Emissions testing, please refer to DA 00-705 Released March 30, 2000, Filing and Measurement
Guidelines for Frequency Hopping Spread Spectrum Systems.
All emissions measurement was performed at Bay Area Compliance Laboratories Corp. (Shenzhen). The
radiated testing was performed at an antenna-to-EUT distance of 3 meters.
FCC Part 15.247
Page 4 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
Measurement Uncertainty
Parameter
Uncertainty
Occupied Channel Bandwidth
±5%
RF Output Power with Power meter
±0.5dB
RF conducted test with spectrum
±1.5dB
AC Power Lines Conducted Emissions
±1.95dB
Emissions,
Radiated
Below 1GHz
Above 1GHz
±4.75dB
±4.88dB
Temperature
±3℃
Humidity
±6%
Supply voltages
±0.4%
Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located
on the 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone,
Shenzhen, Guangdong, China.
The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No.: 342867, the FCC Designation No.: CN1221.
The test site has been registered with ISED Canada under ISED Canada Registration Number 3062B.
FCC Part 15.247
Page 5 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in an engineering mode.
EUT Exercise Software
No exercise software was made to the EUT tested.
Special Accessories
No special accessory.
Equipment Modifications
No modification was made to the EUT tested.
Support Equipment List and Details
Manufacturer
Description
Model
Serial Number
External I/O Cable
Cable Description
Length (m)
From Port
To
Un-shielding Detachable USB Cable
1.0
EUT
Adapter
FCC Part 15.247
Page 6 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
Block Diagram of Test Setup
For conducted emission:
Adapter
LISN
10cm
Receptacle
1.0 Meter
Earphone
EUT
Non-Conductive Table
80 cm above Ground Plane
1.5 Meters
FCC Part 15.247
Page 7 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
SUMMARY OF TEST RESULTS
FCC Rules
Description of Test
Result
§15.247 (i), §1.1307 (b) (1)&
§2.1093
RF Exposure
Compliance
§15.203
Antenna Requirement
Compliance
§15.207(a)
AC Line Conducted Emissions
Compliance
§15.205, §15.209 &
§15.247(d)
Radiated Emissions
Compliance
§15.247(a)(1)
20 dB Emission Bandwidth
Compliance
§15.247(a)(1)
Channel Separation Test
Compliance
§15.247(a)(1)(iii)
Time of Occupancy (Dwell Time)
Compliance
§15.247(a)(1)(iii)
Quantity of hopping channel Test
Compliance
§15.247(b)(1)
Peak Output Power Measurement
Compliance
§15.247(d)
Band edges
Compliance
FCC Part 15.247
Page 8 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
TEST EQUIPMENT LIST
Manufacturer
Description
Serial
Number
Model
Calibration
Date
Calibration
Due Date
Conducted Emissions Test
Rohde & Schwarz
EMI Test Receiver
ESCS30
100176
2018-07-11
2019-07-11
Rohde & Schwarz
LISN
ENV216
3560.6650.12101613-Yb
2017-12-21
2018-12-21
Rohde & Schwarz
Transient Limiter
ESH3Z2
DE25985
2018-11-12
2019-11-12
Rohde & Schwarz
CE Test software
EMC 32
V8.53.0
NCR
NCR
Un-known
Conducted Emission
Cable
78652
UF A210B-10720-504504
2018-11-12
2019-05-12
Radiated Emission Test
A.H. System
Horn Antenna
SAS-200/571
135
2018-09-01
2021-08-31
Rohde & Schwarz
Signal Analyzer
FSEM
845987/005
2018-06-23
2019-06-23
COM-POWER
Pre-amplifier
PA-122
181919
2018-11-12
2019-11-12
Sonoma instrument
Amplifier
310N
186238
2018-11-12
2019-11-12
Sunol Sciences
Broadband Antenna
JB1
A040904-1
2017-12-22
2020-12-21
Rohde & Schwarz
EMI Test Receiver
ESCI
101120
2018-01-11
2019-01-11
RF Cable
UFA147A2362-100100
MFR64639
231029-003
2018-08-01
2019-02-01
RF Cable
104PEA
218124002
2018-11-21
2019-05-21
RF Cable
RG-214
2018-11-19
2019-05-21
RF Cable
RG-214
2018-11-22
2019-05-22
1007726-04
2017-12-29
2020-12-28
15964001002
2018-08-01
2019-02-01
99632
2018-11-21
2019-05-21
V9.10
NCR
NCR
Ducommun
technologies
Ducommun
technologies
Ducommun
technologies
Ducommun
technologies
Ducommun
Technologies
Horn Antenna
Heatsink Required
Amplifier
Sinoscite
Band Reject Filter
Rohde & Schwarz
Auto test software
FCC Part 15.247
ARH-422302
QLW18405536-J0
BSF24022480MN0898-001
EMC 32
Page 9 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Manufacturer
Description
Report No.: RSZ181116001-00B
Model
Serial
Number
Calibration
Date
Calibration
Due Date
2018-06-23
2019-06-23
RF Conducted Test
Agilent
USB wideband power
meter
U2021XA
MY54250003
WEINSCHEL
3dB Attenuator
6231
666
Each Time
WEINSCHEL
10dB Attenuator
N/A
2018004
Each Time
Rohde & Schwarz
Spectrum Analyzer
FSU26
200120
Ducommun
technologies
RF Cable
RG-214
2017-12-24
2018-12-24
Each Time
* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).
FCC Part 15.247
Page 10 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
FCC§15.247 (i), §1.1307 (b) (1) &§2.1093 – RF EXPOSURE
Applicable Standard
According to FCC §2.1093 and §1.1307(b) (1), systems operating under the provisions of this section shall
be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess
of the Commission’s guideline.
According to KDB 447498 D01 General RF Exposure Guidance
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
1. f(GHz) is the RF channel transmit frequency in GHz.
2. Power and distance are rounded to the nearest mW and mm before calculation.
3. The result is rounded to one decimal place for comparison.
4. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR
test Exclusion.
For worst case:
Frequency
(MHz)
2480
Maximum Tune-up
power
(dBm)
(mW)
3.3
2.14
Calculated
Distance
(mm)
Calculated
Value
Threshold
(1-g SAR)
SAR Test
Exclusion
0.7
3.0
Yes
Result: No Standalone SAR test is required
FCC Part 15.247
Page 11 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
FCC §15.203 – ANTENNA REQUIREMENT
Applicable Standard
According to FCC § 15.203, an intentional radiator shall be designed to ensure that no antenna other than
that furnished by the responsible party shall be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this Section. The manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is
prohibited.
Antenna Connector Construction
The EUT has one internal antenna arrangement, which was permanently attached and the antenna gain is
0.8 dBi, fulfill the requirement of this section. Please refer to the EUT photos.
Result: Compliance.
FCC Part 15.247
Page 12 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS
Applicable Standard
FCC §15.207(a)
EUT Setup
The measurement procedure of EUT setup is according with ANSI C63.10-2013. The related limit was
specified in FCC Part 15.207.
The spacing between the peripherals was 10 cm.
EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.
During the conducted emission test, the EMI test receiver was set with the following configurations:
Frequency Range
IF B/W
150 kHz – 30 MHz
9 kHz
Test Procedure
During the conducted emission test, the adapter was connected to the outlet of the LISN.
Maximizing procedure was performed on the six (6) highest emissions of the EUT.
All final data was recorded in the Quasi-peak and average detection mode.
FCC Part 15.247
Page 13 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
Corrected Factor & Margin Calculation
The Corrected factor is calculated by adding LISN VDF (Voltage Division Factor), Cable Loss and
Transient Limiter Attenuation. The basic equation is as follows:
Correction Factor = LISN VDF + Cable Loss + Transient Limiter Attenuation
The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:
Margin = Limit – Corrected Amplitude
Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.207,
Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if
Lm + U(Lm) ≤ Llim + Ucispr
In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.
Test Data
Environmental Conditions
Temperature:
25 ℃
Relative Humidity:
56 %
ATM Pressure:
101.0 kPa
The testing was performed by Haiguo Li on 2018-11-17.
EUT operation mode: Transmitting & charging (the worst case is GFSK Mode, Low channel)
FCC Part 15.247
Page 14 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
AC 120V/60 Hz, Line
90
80
70
QP
Level in dBμ
60
AV
50
40
30
20
10
150k
300 400 500
800 1M
2M
3M 4M 5M 6
8 10M
20M
30M
Frequency in Hz
Frequency
(MHz)
Corrected
Amplitude
(dBμV)
Correction
Factor
(dB)
Limit
(dBμV)
Margin
(dB)
Detector
(PK/Ave./QP)
0.277500
38.9
19.8
60.9
22.0
QP
0.305470
42.9
19.8
60.1
17.2
QP
0.321110
40.5
19.8
59.7
19.2
QP
0.482770
40.8
19.8
56.3
15.5
QP
0.482830
40.7
19.8
56.3
15.6
QP
0.995150
37.7
19.8
56.0
18.3
QP
0.277500
33.5
19.8
50.9
17.4
Ave.
0.305470
34.4
19.8
50.1
15.7
Ave.
0.321110
33.5
19.8
49.7
16.2
Ave.
0.482770
32.0
19.8
46.3
14.3
Ave.
0.482830
31.9
19.8
46.3
14.4
Ave.
0.995150
28.4
19.8
46.0
17.6
Ave.
FCC Part 15.247
Page 15 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
AC 120V/60 Hz, Neutral
90
80
70
QP
Level in dBμ
60
AV
50
40
30
20
10
150k
300 400 500
800 1M
2M
3M 4M 5M 6
8 10M
20M
30M
Frequency in Hz
Frequency
(MHz)
Corrected
Amplitude
(dBμV)
Correction
Factor
(dB)
Limit
(dBμV)
Margin
(dB)
Detector
(PK/Ave./QP)
0.161500
40.9
19.7
65.4
24.5
QP
0.285500
43.0
19.8
60.7
17.7
QP
0.293500
43.9
19.8
60.4
16.5
QP
0.317230
40.4
19.8
59.8
19.4
QP
1.007090
35.7
19.8
56.0
20.3
QP
1.101710
35.7
19.8
56.0
20.3
QP
0.161500
25.9
19.7
55.4
29.5
Ave.
0.285500
36.8
19.8
50.7
13.9
Ave.
0.293500
38.3
19.8
50.4
12.1
Ave.
0.317230
34.2
19.8
49.8
15.6
Ave.
1.007090
26.5
19.8
46.0
19.5
Ave.
1.101710
27.7
19.8
46.0
18.3
Ave.
Note:
1) Correction Factor =LISN VDF (Voltage Division Factor) + Cable Loss + Transient Limiter Attenuation
2) Corrected Amplitude = Reading + Correction Factor
3) Margin = Limit – Corrected Amplitude
FCC Part 15.247
Page 16 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
FCC §15.205, §15.209 & §15.247(d) – RADIATED EMISSIONS
Applicable Standard
FCC §15.205; §15.209; §15.247(d)
EUT Setup
Below 1 GHz:
Above 1GHz:
The radiated emission tests were performed in the 3 meters, using the setup accordance with the ANSI
C63.10-2013. The specification used was the FCC 15.209 and FCC 15.247 limits.
FCC Part 15.247
Page 17 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
EMI Test Receiver & Spectrum Analyzer Setup
The system was investigated from 30 MHz to 25 GHz.
During the radiated emission test, according to the DA 00-705 Released March 30, 2000, the EMI test
receiver & Spectrum Analyzer Setup were set with the following configurations:
Frequency Range
RBW
Video B/W
IF B/W
Measurement
30 MHz – 1000 MHz
100 kHz
1 MHz
1 MHz
300 kHz
3 MHz
10 Hz
120 kHz
QP
PK
Average
Above 1 GHz
Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.
All final data was recorded in Quasi-peak detection mode for frequency range of 30 MHz -1 GHz and peak
and Average detection modes for frequencies above 1 GHz.
Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:
Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain
The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:
Margin = Limit – Corrected Amplitude
Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Title 47, Part 15,
Subpart C, section 15.205, 15.209 and 15.247.
Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if
Lm + U(Lm ) ≤ Llim  Ucispr
In BACL, U(Lm ) is less thanUcispr, if Lm is less than Llim, it implies that the EUT complies with the limit.
FCC Part 15.247
Page 18 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
Test Data
Environmental Conditions
Temperature:
25 ℃
Relative Humidity:
56 %
ATM Pressure:
101.0 kPa
The testing was performed by Hill He on 2018-11-22.
EUT operation mode: Transmitting (Scan with GFSK, π/4-DQPSK, 8DPSK mode, the worst case is GFSK Mode)
FCC Part 15.247
Page 19 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
30 MHz~1 GHz: (the worst case is GFSK Mode, Low channel)
80
70
60
Electric Field Strength QP-3m
Level in dBμV/
50
40
30
20
10
30M
50
60
80 100M
200
300
400
500
800
1G
Frequency in Hz
Frequency
(MHz)
Corrected
Amplitude
(dBμV/m)
Antenna
height
(cm)
Antenna
Polarity
Turntable
position
(degree)
Correction
Factor
(dB/m)
Limit
(dBμV/m)
Margin
(dB)
167.990125
26.14
150.0
100.0
-14.8
43.50
17.36
216.001625
28.16
132.0
117.0
-13.9
46.00
17.84
407.981500
27.61
108.0
127.0
-10.0
46.00
18.39
696.005250
29.32
116.0
156.0
-1.4
46.00
16.68
838.095000
30.07
368.0
307.0
5.8
46.00
15.93
893.070000
27.16
387.0
92.0
4.5
46.00
18.84
FCC Part 15.247
Page 20 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
1 GHz - 25 GHz:
Frequency
(MHz)
Receiver
Reading
PK/QP/Ave.
(dBμV)
2399.31
2399.31
2484.25
2484.25
4804.00
4804.00
27.89
13.86
27.19
13.64
44.20
31.02
PK
Ave.
PK
Ave.
PK
Ave.
4882.00
4882.00
43.94
30.25
PK
Ave.
2399.46
2399.46
2483.50
2483.50
4960.00
4960.00
27.15
13.63
28.62
17.73
43.80
30.13
PK
Ave.
PK
Ave.
PK
Ave.
Rx Antenna Corrected Corrected
Turntable
Limit
Height
Polar Factor Amplitude (dBμV/m)
Degree
(m) (H/V) (dB/m) (dBμV/m)
Low Channel (2402 MHz)
208
1.4
33.00
208
1.4
33.00
162
1.1
33.20
162
1.1
33.20
21
1.2
7.88
21
1.2
7.88
Middle Channel (2441 MHz)
24
1.7
9.21
24
1.7
9.21
High Channel (2480 MHz)
82
1.8
33.00
82
1.8
33.00
235
1.1
33.20
235
1.1
33.20
79
2.3
9.07
79
2.3
9.07
Margin
(dB)
60.89
46.86
60.39
46.84
52.08
38.90
74
54
74
54
74
54
13.11
7.14
13.61
7.16
21.92
15.10
53.15
39.46
74
54
20.85
14.54
60.15
46.63
61.82
50.93
52.87
39.20
74
54
74
54
74
54
13.85
7.37
12.18
3.07
21.13
14.80
Note:
Corrected Factor = Antenna factor (RX) + Cable Loss – Amplifier Factor
Corrected Amplitude = Corrected Factor + Reading
Margin = Limit - Corrected. Amplitude
The other spurious emission which is 20dB to the limit was not recorded.
And for the pre-scan is performed with the 2400-2483.5MHz band filter.
FCC Part 15.247
Page 21 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
Pre-scan with middle channel Peak
Horizontal
FCC Part 15.247
Page 22 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
Vertical
FCC Part 15.247
Page 23 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
Pre-scan for Average
Horizontal
FCC Part 15.247
Page 24 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
Vertical
FCC Part 15.247
Page 25 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
FCC §15.247(a) (1)-CHANNEL SEPARATION TEST
Applicable Standard
Frequency hopping systems shall have hoping channel carrier frequencies separated by a minimum of 25
kHz or the 20 dB bandwidth of the hopping channel, whichever is greater. Alternatively, frequency
hopping systems operating in the 2400-2483.5 MHz band may have hopping channel carrier frequencies
that are separated by 25 kHz or two-thirds of the 20 dB bandwidth of the hopping channel, whichever is
greater provided the systems operate with an output power no greater than 125 mW. The system shall hop
to channel frequencies that are selected at the system hopping rate from a pseudo randomly ordered list of
hopping frequencies. Each frequency must be used equally on the average by each transmitter. The system
receivers shall have input bandwidths that match the hopping channel bandwidths of their corresponding
transmitters and shall shift frequencies in synchronization with the transmitted signals.
Test Procedure
1. Set the EUT in transmitting mode, maxhold the channel.
2. Set the adjacent channel of the EUT and maxhold another trace.
3. Measure the channel separation.
Test Data
Environmental Conditions
Temperature:
25 ℃
Relative Humidity:
56 %
ATM Pressure:
101.0 kPa
The testing was performed by Hill He on 2018-11-21.
EUT operation mode: Transmitting
Test Result: Compliance. Please refer to following table and plots.
FCC Part 15.247
Page 26 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Mode
BDR
(GFSK)
EDR
(π/4-DQPSK)
EDR
(8DPSK)
Channel
Frequency
(MHz)
Low
2402
Adjacent
2403
Middle
2441
Adjacent
2442
High
2480
Adjacent
2479
Low
2402
Adjacent
2403
Middle
2441
Adjacent
2442
High
2480
Adjacent
Low
Adjacent
2479
2402
2403
Middle
2441
Adjacent
2442
High
2480
Adjacent
2479
Report No.: RSZ181116001-00B
Channel
Separation
(MHz)
≥Limit
(MHz)
Result
1.000
0.622
Pass
1.005
0.628
Pass
0.995
0.625
Pass
1.000
0.837
Pass
1.000
0.837
Pass
1.000
0.840
Pass
1.005
0.846
Pass
1.005
0.846
Pass
1.005
0.843
Pass
Note: Limit = 20 dB bandwidth *2/3
FCC Part 15.247
Page 27 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
BDR (GFSK): Low Channel
* RBW 30 kHz
* VBW 100 kHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
1.02 dBm
2.401836538 GHz
10.5 dB
10
1 PK
MAXH
Delta 1 [T1 ]
-0.03 dB
1.000000000 MHz
LVL
-10
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.402 GHz
Date: 21.NOV.2018
300 kHz/
Span
3 MHz
13:59:22
BDR (GFSK): Middle Channel
* RBW 30 kHz
* VBW 100 kHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
0.81 dBm
2.440831731 GHz
10.5 dB
10
1 PK
MAXH
Delta 1 [T1 ]
0.11 dB
1.004807692 MHz
LVL
-10
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4415 GHz
Date: 21.NOV.2018
FCC Part 15.247
300 kHz/
Span
3 MHz
13:56:22
Page 28 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
BDR (GFSK): High Channel
* RBW 30 kHz
* VBW 100 kHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
0.10 dBm
2.478836538 GHz
10.5 dB
10
1 PK
MAXH
Delta 1 [T1 ]
-0.29 dB
995.192307693 kHz
LVL
-10
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4795 GHz
Date: 21.NOV.2018
300 kHz/
Span
3 MHz
13:52:30
EDR (π/4-DQPSK): Low Channel
* RBW 30 kHz
* VBW 100 kHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-0.19 dBm
2.401831731 GHz
10.5 dB
10
1 PK
MAXH
Delta 1 [T1 ]
0.01 dB
1.000000000 MHz
LVL
-10
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4025 GHz
Date: 21.NOV.2018
FCC Part 15.247
300 kHz/
Span
3 MHz
13:24:59
Page 29 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
EDR (π/4-DQPSK): Middle Channel
* RBW 30 kHz
* VBW 100 kHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-1.64 dBm
2.441009615 GHz
10.5 dB
10
1 PK
MAXH
Delta 1 [T1 ]
-0.05 dB
999.999999998 kHz
LVL
-10
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4415 GHz
Date: 21.NOV.2018
300 kHz/
Span
3 MHz
13:32:35
EDR (π/4-DQPSK): High Channel
* RBW 30 kHz
* VBW 100 kHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-0.83 dBm
2.478841346 GHz
10.5 dB
10
1 PK
MAXH
Delta 1 [T1 ]
-0.08 dB
999.999999999 kHz
LVL
-10
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4795 GHz
Date: 21.NOV.2018
FCC Part 15.247
300 kHz/
Span
3 MHz
13:36:30
Page 30 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
EDR (8DPSK): Low Channel
* RBW 30 kHz
* VBW 100 kHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-1.37 dBm
2.401831731 GHz
10.5 dB
10
1 PK
MAXH
Delta 1 [T1 ]
-0.18 dB
1.004807692 MHz
LVL
-10
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4025 GHz
Date: 21.NOV.2018
300 kHz/
Span
3 MHz
13:19:00
EDR (8DPSK): Middle Channel
* RBW 30 kHz
* VBW 100 kHz
Ref
* Att
14 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-1.48 dBm
2.440836538 GHz
10.5 dB
10
1 PK
MAXH
Delta 1 [T1 ]
-0.02 dB
1.004807692 MHz
LVL
-10
-20
-30
-40
3DB
-50
-60
-70
-80
Center
2.4415 GHz
Date: 21.NOV.2018
FCC Part 15.247
300 kHz/
Span
3 MHz
13:14:01
Page 31 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
EDR (8DPSK): High Channel
* RBW 30 kHz
* VBW 100 kHz
Ref
* Att
14 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-2.08 dBm
2.478831731 GHz
10.5 dB
10
1 PK
MAXH
Delta 1 [T1 ]
-0.10 dB
1.004807692 MHz
LVL
-10
-20
-30
-40
3DB
-50
-60
-70
-80
Center
2.4795 GHz
Date: 21.NOV.2018
FCC Part 15.247
300 kHz/
Span
3 MHz
13:09:53
Page 32 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
FCC §15.247(a) (1) – 20 dB EMISSION BANDWIDTH
Applicable Standard
Alternatively, frequency hopping systems operating in the 2400–2483.5 MHz band may have hopping
channel carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB bandwidth of the
hopping channel, whichever is greater, provided the systems operate with an output power no greater than
125 mW.
Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect it to
measurement instrument. Then set it to any one convenient frequency within its operating range. Set a
reference level on the measuring instrument equal to the highest peak value.
3. Measure the frequency difference of two frequencies that were attenuated 20 dB from the reference
level. Record the frequency difference as the emission bandwidth.
4. Repeat above procedures until all frequencies measured were complete.
Test Data
Environmental Conditions
Temperature:
25 ℃
Relative Humidity:
56 %
ATM Pressure:
101.0 kPa
The testing was performed by Hill He on 2018-11-21.
EUT operation mode: Transmitting
Test Result: Compliance. Please refer to following table and plots.
Mode
BDR
(GFSK)
EDR
(π/4-DQPSK)
EDR
(8DPSK)
FCC Part 15.247
Channel
Frequency
(MHz)
20 dB Emission
Bandwidth
(MHz)
Low
2402
0.933
Middle
2441
0.942
High
2480
0.937
Low
2402
1.255
Middle
2441
1.255
High
2480
1.260
Low
2402
1.269
Middle
2441
1.269
High
2480
1.264
Page 33 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
BDR (GFSK): Low Channel
* RBW 30 kHz
* VBW 100 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-20.23 dBm
2.401538462 GHz
10.5 dB
10
1 PK
MAXH
Delta 1 [T1 ]
1.63 dB
932.692307690 kHz
D1 0.9 dBm
LVL
-10
D2 -19.1 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.402 GHz
Date: 21.NOV.2018
300 kHz/
Span
3 MHz
12:13:35
BDR (GFSK): Middle Channel
* RBW 30 kHz
* VBW 100 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-20.24 dBm
2.440538462 GHz
10.5 dB
10
1 PK
MAXH
Delta 1 [T1 ]
0.94 dB
942.307692307 kHz
D1 0.79 dBm
LVL
-10
D2 -19.21 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.441 GHz
Date: 21.NOV.2018
FCC Part 15.247
300 kHz/
Span
3 MHz
12:12:05
Page 34 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
BDR (GFSK): High Channel
* RBW 30 kHz
Delta 1 [T1 ]
1.50 dB
937.499999998 kHz
* VBW 100 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-21.16 dBm
2.479538462 GHz
10.5 dB
10
1 PK
MAXH
D1 0.13 dBm
LVL
-10
D2 -19.87 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.48 GHz
Date: 21.NOV.2018
300 kHz/
Span
3 MHz
12:09:25
EDR (π/4-DQPSK): Low Channel
* RBW 30 kHz
Delta 1 [T1 ]
0.95 dB
1.254807692 MHz
* VBW 100 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-20.76 dBm
2.401360577 GHz
10.5 dB
10
1 PK
MAXH
D1 -0.14 dBm
LVL
-10
D2 -20.14 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.402 GHz
Date: 21.NOV.2018
FCC Part 15.247
300 kHz/
Span
3 MHz
10:58:29
Page 35 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
EDR (π/4-DQPSK): Middle Channel
* RBW 30 kHz
Delta 1 [T1 ]
1.56 dB
1.254807692 MHz
* VBW 100 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-21.04 dBm
2.440360577 GHz
10.5 dB
10
1 PK
MAXH
D1 0.06 dBm
LVL
-10
D2 -19.94 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.441 GHz
Date: 21.NOV.2018
300 kHz/
Span
3 MHz
12:05:15
EDR (π/4-DQPSK): High Channel
* RBW 30 kHz
Delta 1 [T1 ]
0.86 dB
1.259615385 MHz
* VBW 100 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-21.55 dBm
2.479360577 GHz
10.5 dB
10
1 PK
MAXH
D1 -0.72 dBm
LVL
-10
D2 -20.72 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.48 GHz
Date: 21.NOV.2018
FCC Part 15.247
300 kHz/
Span
3 MHz
12:06:42
Page 36 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
EDR (8DPSK): Low Channel
* RBW 30 kHz
Delta 1 [T1 ]
0.71 dB
1.269230769 MHz
* VBW 100 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-22.01 dBm
2.401360577 GHz
10.5 dB
10
1 PK
MAXH
D1 -1.5 dBm
LVL
-10
D2 -21.5 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.402 GHz
Date: 21.NOV.2018
300 kHz/
Span
3 MHz
10:57:02
EDR (8DPSK): Middle Channel
* RBW 30 kHz
Delta 1 [T1 ]
0.75 dB
1.269230769 MHz
* VBW 100 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-22.17 dBm
2.440360577 GHz
10.5 dB
10
1 PK
MAXH
D1 -1.52 dBm
LVL
-10
D2 -21.52 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.441 GHz
Date: 21.NOV.2018
FCC Part 15.247
300 kHz/
Span
3 MHz
10:55:25
Page 37 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
EDR (8DPSK): High Channel
* RBW 30 kHz
Delta 1 [T1 ]
1.11 dB
1.264423077 MHz
* VBW 100 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 15 ms
Marker 1 [T1 ]
-22.71 dBm
2.479360577 GHz
10.5 dB
10
1 PK
MAXH
LVL
D1 -2.19 dBm
-10
D2 -22.19 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.48 GHz
Date: 21.NOV.2018
FCC Part 15.247
300 kHz/
Span
3 MHz
10:53:32
Page 38 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
FCC §15.247(a) (1) (iii)-QUANTITY OF HOPPING CHANNEL TEST
Applicable Standard
Frequency hopping systems in the 2400–2483.5 MHz band shall use at least 15 channels. The average time
of occupancy on any channel shall not be greater than 0.4 seconds within a period of 0.4 seconds
multiplied by the number of hopping channels employed. Frequency hopping systems may avoid or
suppress transmissions on a particular hopping frequency provided that a minimum of 15 channels are
used.
Test Procedure
1. Check the calibration of the measuring instrument (SA) using either an internal calibrator or a known
signal from an external generator.
2. Set the EUT in hopping mode from first channel to last.
3. By using the max-hold function record the quantity of the channel.
Test Data
Environmental Conditions
Temperature:
25 ℃
Relative Humidity:
56 %
ATM Pressure:
101.0 kPa
The testing was performed by Hill He on 2018-11-21.
EUT operation mode: Transmitting
Test Result: Compliance. Please refer to following table and plots.
Mode
BDR
(GFSK)
EDR
(π/4-DQPSK)
EDR
(8DPSK)
FCC Part 15.247
Frequency Range
(MHz)
Number of Hopping
Channel
(CH)
Limit
(CH)
2400-2483.5
79
≥15
2400-2483.5
79
≥15
2400-2483.5
79
≥15
Page 39 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
BDR (GFSK): Number of Hopping Channels
* RBW 100 kHz
* VBW 300 kHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 10 ms
Marker 1 [T1 ]
2.66 dBm
2.401873397 GHz
10.5 dB
10
1 PK
MAXH
Delta 1 [T1 ]
-0.83 dB
78.281250000 MHz
LVL
-10
-20
-30
3DB
-40
-50
-60
-70
-80
Start
2.4 GHz
Date: 21.NOV.2018
8.35 MHz/
Stop
2.4835 GHz
14:55:38
EDR (π/4-DQPSK): Number of Hopping Channels
* RBW 100 kHz
* VBW 300 kHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 10 ms
Delta 1 [T1 ]
-0.89 dB
78.281250000 MHz
Marker 1 [T1 ]
1.71 dBm
2.401739583 GHz
10.5 dB
10
1 PK
MAXH
LVL
-10
-20
-30
3DB
-40
-50
-60
-70
-80
Start
2.4 GHz
Date: 21.NOV.2018
FCC Part 15.247
8.35 MHz/
Stop
2.4835 GHz
14:59:36
Page 40 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
EDR (8DPSK): Number of Hopping Channels
* RBW 100 kHz
* VBW 300 kHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 10 ms
Marker 1 [T1 ]
-0.36 dBm
2.401739583 GHz
10.5 dB
10
1 PK
MAXH
Delta 1 [T1 ]
0.44 dB
78.415064103 MHz
LVL
-10
-20
-30
3DB
-40
-50
-60
-70
-80
Start
2.4 GHz
Date: 21.NOV.2018
FCC Part 15.247
8.35 MHz/
Stop
2.4835 GHz
15:06:15
Page 41 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
FCC §15.247(a) (1) (iii) - TIME OF OCCUPANCY (DWELL TIME)
Applicable Standard
Frequency hopping systems in the 2400-2483.5 MHz shall use at least 15 channels. The average time of
occupancy on any channel shall not be greater than 0.4 seconds within a period of 0.4 seconds multiplied
by the number of hopping channels employed. Frequency hopping systems may avoid or suppress
transmissions on a particular hopping frequency provided that a minimum of 15 channels are used.
Test Procedure
1.
2.
3.
4.
5.
6.
7.
8.
9.
The EUT was worked in channel hopping.
Set the RBW to: 1MHz.
Set the VBW ≥ 3×RBW.
Set the span to 0Hz.
Detector = peak.
Sweep time = auto couple.
Trace mode = max hold.
Allow trace to fully stabilize.
Recorded the time of single pulses
Test Data
Environmental Conditions
Temperature:
25 ℃
Relative Humidity:
56 %
ATM Pressure:
101.0 kPa
The testing was performed by Hill He on 2018-11-21.
EUT operation mode: Transmitting
FCC Part 15.247
Page 42 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
Test Result: Compliance. Please refer to following table and plots
Mode
Channel
DH 1
BDR
(GFSK)
DH 3
DH 5
2DH 1
EDR
(π/4-DQPSK)
2DH 3
2DH 5
3DH 1
EDR Mode
(8 DPSK)
3DH 3
3DH 5
FCC Part 15.247
Pulse Width
(ms)
Dwell Time
(S)
Limit
(S)
Result
Low
0.394
0.126
0.4
Note: DH1:Dwell time = Pulse time*(1600/2/79)*31.6S
Low
1.678
0.268
0.4
Note: DH3:Dwell time = Pulse time*(1600/4/79)*31.6S
Low
2.909
0.310
0.4
Note: DH5:Dwell time = Pulse time*(1600/6/79)*31.6S
Pass
Low
Pass
0.399
0.128
0.4
Note: 2DH1:Dwell time = Pulse time*(1600/2/79)*31.6S
Low
1.668
0.267
0.4
Note: 2DH3:Dwell time = Pulse time*(1600/4/79)*31.6S
Low
2.941
0.314
0.4
Note:2DH5:Dwell time = Pulse time*(1600/6/79)*31.6S
Low
0.401
0.128
0.4
Note: 3DH1:Dwell time = Pulse time*(1600/2/79)*31.6S
Low
1.668
0.267
0.4
Note: 3DH3:Dwell time = Pulse time*(1600/4/79)*31.6S
Low
2.917
0.311
0.4
Note: 3DH5:Dwell time = Pulse time*(1600/6/79)*31.6s
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Page 43 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
BDR (GFSK):
Pulse time, DH1
RBW 1 MHz
* VBW 1 MHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 1 ms
Marker 1 [T1 ]
-66.94 dBm
-4.487179 µs
10.5 dB
10
1 PK *
CLRWR
Delta 1 [T1 ]
1.55 dB
394.230769 µs
SGL
TRG
LVL
-10
TRG -13.1 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center 2.402 GHz
Date: 21.NOV.2018
100 µs/
14:14:44
Pulse time, DH3
RBW 1 MHz
* VBW 1 MHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 3 ms
Marker 1 [T1 ]
-65.83 dBm
-7.692308 µs
10.5 dB
10
1 PK *
CLRWR
Delta 1 [T1 ]
3.70 dB
1.677885 ms
-10
SGL
TRG
LVL
TRG -11.4 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center 2.402 GHz
Date: 21.NOV.2018
FCC Part 15.247
300 µs/
14:24:20
Page 44 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
Pulse time, DH5
RBW 1 MHz
Delta 1 [T1 ]
2.64 dB
2.908654 ms
* VBW 1 MHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 5 ms
Marker 1 [T1 ]
-63.51 dBm
-10.897436 µs
10.5 dB
10
1 PK *
CLRWR
-10
SGL
TRG
LVL
TRG -11.4 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center 2.402 GHz
Date: 21.NOV.2018
500 µs/
14:28:12
EDR (π/4-DQPSK):
Pulse time, 2DH1
RBW 1 MHz
Delta 1 [T1 ]
0.58 dB
399.038462 µs
* VBW 1 MHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 1 ms
Marker 1 [T1 ]
-65.12 dBm
-1.923077 µs
10.5 dB
10
1 PK *
CLRWR
-10
SGL
TRG
LVL
TRG -11.4 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center 2.402 GHz
Date: 21.NOV.2018
FCC Part 15.247
100 µs/
14:30:18
Page 45 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
Pulse time, 2DH3
RBW 1 MHz
Delta 1 [T1 ]
1.07 dB
1.668269 ms
* VBW 1 MHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 3 ms
Marker 1 [T1 ]
-63.93 dBm
-8.653846 µs
10.5 dB
10
1 PK *
CLRWR
-10
SGL
TRG
LVL
TRG -11.4 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center 2.402 GHz
Date: 21.NOV.2018
300 µs/
14:36:14
Pulse time, 2DH5
RBW 1 MHz
Delta 1 [T1 ]
2.29 dB
2.940705 ms
* VBW 1 MHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 5 ms
Marker 1 [T1 ]
-63.97 dBm
-39.102564 µs
10.5 dB
10
1 PK *
CLRWR
-10
SGL
TRG
LVL
TRG -11.4 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center 2.402 GHz
Date: 21.NOV.2018
FCC Part 15.247
500 µs/
14:37:33
Page 46 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
EDR (8DPSK):
Pulse time, 3DH1
RBW 1 MHz
Delta 1 [T1 ]
1.42 dB
400.641026 µs
* VBW 1 MHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 1 ms
Marker 1 [T1 ]
-67.21 dBm
-3.525641 µs
10.5 dB
10
1 PK *
CLRWR
-10
SGL
TRG
LVL
TRG -11.4 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center 2.402 GHz
Date: 21.NOV.2018
100 µs/
14:41:48
Pulse time, 3DH3
RBW 1 MHz
* VBW 1 MHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 3 ms
Marker 1 [T1 ]
-62.37 dBm
-6.730769 µs
10.5 dB
10
1 PK *
CLRWR
-10
Delta 1 [T1 ]
-1.21 dB
1.668269 ms
SGL
TRG
LVL
TRG -11.4 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center 2.402 GHz
Date: 21.NOV.2018
FCC Part 15.247
300 µs/
14:42:52
Page 47 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
Pulse time, 3DH5
RBW 1 MHz
* VBW 1 MHz
Ref
* Att
17 dBm
Offset
10 dB
SWT 5 ms
Marker 1 [T1 ]
-61.31 dBm
-6.410256 µs
10.5 dB
10
1 PK *
CLRWR
Delta 1 [T1 ]
-1.44 dB
2.916667 ms
-10
SGL
TRG
LVL
TRG -11.4 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center 2.402 GHz
Date: 21.NOV.2018
FCC Part 15.247
500 µs/
14:46:45
Page 48 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
FCC §15.247(b) (1) - PEAK OUTPUT POWER MEASUREMENT
Applicable Standard
According to §15.247(b) (1), for frequency hopping systems operating in the 2400–2483.5 MHz band
employing at least 75 non-overlapping hopping channels, and all frequency hopping systems in the 57255850 MHz band: 1 watt. And for all other frequency hopping systems in the 2400–2483.5 MHz band:
0.125 watts.
Test Procedure
1. Place the EUT on a bench and set in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to one
test equipment.
3. Add a correction factor to the display.
Test Data
Environmental Conditions
Temperature:
25 ℃
Relative Humidity:
56 %
ATM Pressure:
101.0 kPa
The testing was performed by Hill He on 2018-11-21.
EUT operation mode: Transmitting
Test Result: Compliance. Please refer to following table.
Mode
BDR
(GFSK)
EDR
(π/4-DQPSK)
EDR
(8DPSK)
FCC Part 15.247
Channel
Frequency
(MHz)
Peak Output Power
(dBm)
(mW)
Limit
(mW)
Low
2402
3.30
2.14
125
Middle
2441
3.13
2.06
125
High
2480
2.37
1.73
125
Low
2402
2.87
1.94
125
Middle
2441
2.77
1.89
125
High
2480
2.05
1.60
125
Low
2402
2.98
1.99
125
Middle
2441
2.82
1.91
125
High
2480
2.10
1.62
125
Page 49 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
FCC §15.247(d) - BAND EDGES TESTING
Applicable Standard
In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated
intentional radiator is operating, the radio frequency power that is produced by the intentional radiator
shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level
of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter
demonstrates compliance with the peak conducted power limits. If the transmitter complies with the
conducted power limits based on the use of RMS averaging over a time interval, as permitted under
paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20
dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated
emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated
emission limits specified in §15.209(a) (see §15.205(c)).
Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
from an external generator.
2. Remove the antenna from the EUT and then connect to a low loss RF cable from the antenna port to a
EMI test receiver, then turn on the EUT and make it operate in transmitting mode. Then set it to Low
Channel and High Channel within its operating range, and make sure the instrument is operated in its
linear range.
3. Set RBW of spectrum analyzer to 100 kHz with a convenient frequency span including 100 kHz
bandwidth from band edge.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.
Test Data
Environmental Conditions
Temperature:
25 ℃
Relative Humidity:
56 %
ATM Pressure:
101.0 kPa
The testing was performed by Hill He on 2018-11-21 and 2018-11-29.
EUT operation mode: Transmitting
Test Result: Compliance. Please refer to following plots.
FCC Part 15.247
Page 50 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
BDR (GFSK): Band Edge-Left Side
Hopping
* RBW 100 kHz
* VBW 300 kHz
Ref
* Att
19 dBm
Offset
20 dB
SWT 20 ms
Marker 1 [T1 ]
-51.65 dBm
2.324038462 GHz
10.5 dB
10
1 PK
MAXH
D1 3.4 dBm
LVL
-10
D2 -16.6 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4 GHz
Date: 29.NOV.2018
20 MHz/
Span
200 MHz
09:36:18
Single
* RBW 100 kHz
* VBW 300 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 5 ms
Marker 1 [T1 ]
-44.91 dBm
2.399262821 GHz
10.5 dB
10
1 PK
MAXH
D1 2.91 dBm
LVL
-10
D2 -17.09 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4 GHz
Date: 21.NOV.2018
FCC Part 15.247
1 MHz/
Span
10 MHz
12:19:20
Page 51 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
BDR (GFSK): Band Edge-Right Side
Hopping
* RBW 100 kHz
Marker 1 [T1 ]
-54.07 dBm
2.527089744 GHz
* VBW 300 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 20 ms
10.5 dB
10
1 PK
MAXH
D1 3.1 dBm
LVL
-10
D2 -16.9 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4835 GHz
Date: 21.NOV.2018
20 MHz/
Span
200 MHz
12:23:04
Single
* RBW 100 kHz
* VBW 300 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 5 ms
Marker 1 [T1 ]
-47.93 dBm
2.483612179 GHz
10.5 dB
10
1 PK
MAXH
D1 2.05 dBm
LVL
-10
D2 -17.95 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4835 GHz
Date: 21.NOV.2018
FCC Part 15.247
1 MHz/
Span
10 MHz
12:21:08
Page 52 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
EDR (π/4-DQPSK): Band Edge-Left Side
Hopping
* RBW 100 kHz
* VBW 300 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 20 ms
Marker 1 [T1 ]
-49.11 dBm
2.399358974 GHz
10.5 dB
10
1 PK
MAXH
D1 2.04 dBm
LVL
-10
D2 -17.96 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4 GHz
Date: 21.NOV.2018
20 MHz/
Span
200 MHz
12:29:17
Single
* RBW 100 kHz
* VBW 300 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 5 ms
Marker 1 [T1 ]
-49.02 dBm
2.399919872 GHz
10.5 dB
10
1 PK
MAXH
D1 1.95 dBm
LVL
-10
D2 -18.05 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4 GHz
Date: 21.NOV.2018
FCC Part 15.247
1 MHz/
Span
10 MHz
12:39:52
Page 53 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
EDR (π/4-DQPSK): Band Edge-Right Side
Hopping
* RBW 100 kHz
* VBW 300 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 20 ms
Marker 1 [T1 ]
-54.75 dBm
2.510743590 GHz
10.5 dB
10
1 PK
MAXH
D1 2.17 dBm
LVL
-10
D2 -17.83 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4835 GHz
Date: 21.NOV.2018
20 MHz/
Span
200 MHz
12:32:04
Single
* RBW 100 kHz
* VBW 300 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 5 ms
Marker 1 [T1 ]
-53.46 dBm
2.483580128 GHz
10.5 dB
10
1 PK
MAXH
D1 1.16 dBm
LVL
-10
D2 -18.84 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4835 GHz
Date: 21.NOV.2018
FCC Part 15.247
1 MHz/
Span
10 MHz
12:41:39
Page 54 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
EDR (8DPSK): Band Edge-Left Side
Hopping
* RBW 100 kHz
* VBW 300 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 20 ms
Marker 1 [T1 ]
-51.28 dBm
2.399679487 GHz
10.5 dB
10
1 PK
MAXH
D1 2.22 dBm
LVL
-10
D2 -17.78 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4 GHz
Date: 21.NOV.2018
20 MHz/
Span
200 MHz
12:48:31
Single
* RBW 100 kHz
* VBW 300 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 5 ms
Marker 1 [T1 ]
-48.95 dBm
2.399855769 GHz
10.5 dB
10
1 PK
MAXH
D1 1.9 dBm
LVL
-10
D2 -18.1 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4 GHz
Date: 21.NOV.2018
FCC Part 15.247
1 MHz/
Span
10 MHz
12:44:40
Page 55 of 56
Bay Area Compliance Laboratories Corp. (Shenzhen)
Report No.: RSZ181116001-00B
EDR (8DPSK): Band Edge-Right Side
Hopping
* RBW 100 kHz
* VBW 300 kHz
Ref
* Att
14 dBm
Offset
10 dB
SWT 20 ms
Marker 1 [T1 ]
-59.52 dBm
2.483820513 GHz
10.5 dB
10
D1 2.26 dBm
1 PK
MAXH
LVL
-10
D2 -17.74 dBm
-20
-30
-40
3DB
-50
-60
-70
-80
Center
2.4835 GHz
Date: 21.NOV.2018
20 MHz/
Span
200 MHz
12:54:23
Single
* RBW 100 kHz
* VBW 300 kHz
Ref
20
* Att
20 dBm
Offset
10 dB
SWT 5 ms
Marker 1 [T1 ]
-53.42 dBm
2.483676282 GHz
10.5 dB
10
1 PK
MAXH
D1 1.09 dBm
LVL
-10
D2 -18.91 dBm
-20
-30
3DB
-40
-50
-60
-70
-80
Center
2.4835 GHz
Date: 21.NOV.2018
1 MHz/
Span
10 MHz
12:42:59
***** END OF REPORT *****
FCC Part 15.247
Page 56 of 56
Download: K536 Smart Phone Test Report  Epik One America Corporation
Mirror Download [FCC.gov]K536 Smart Phone Test Report  Epik One America Corporation
Document ID4121485
Application IDBAobID25IvBlDAv7xUp0zw==
Document DescriptionTest Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize88.16kB (1101978 bits)
Date Submitted2018-12-28 00:00:00
Date Available2018-12-28 00:00:00
Creation Date2018-12-27 18:16:37
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2018-12-27 18:16:37
Document TitleTest Report
Document CreatorPScript5.dll Version 5.2.2
Document Author: SZ8102

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : SZ8102
Create Date                     : 2018:12:27 18:16:37+08:00
Modify Date                     : 2018:12:27 18:16:37+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Format                          : application/pdf
Title                           : Microsoft Word - RSZ181116001-00B FCC Part 15.247 BT Report--已改,标红.doc
Creator                         : SZ8102
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:846d3cdb-c454-4757-82f0-8358d69fc64a
Instance ID                     : uuid:c886119d-5050-45b2-911b-ba1cf72cb143
Page Count                      : 56