FCC ID 2AOHT-HYLETON-331

SMART POWER STRIP

by Shenzhen Hyleton Technology Co.,Ltd.

Grantee Code: 2AOHT   Product Code: HYLETON331
Latest application date: 2018-07-23

FCC ID Device Details

FCC ID2AOHT-HYLETON-331
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AOHT
Product CodeHYLETON331
Applicant BusinessShenzhen Hyleton Technology Co.,Ltd. 🇨🇳
Equipment ClassSMART POWER STRIP
Test FirmShenzhen NTEK Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2018-07-23

Exhibits

DocumentTypeAvailableFile
Users manualUsers Manual2018-07-23PDF 2.5 MB
Internal photoInternal Photos2018-07-23PDF 738.8 KB
External photoExternal Photos2018-07-23PDF 150.3 KB
LabelID Label/Location Info2018-07-23PDF 195.5 KB
Test setup photoTest Setup Photos2018-07-23PDF 283 KB
Test reportTest Report2018-07-23PDF 3.3 MB
Authorization letterCover Letter(s)2018-07-23PDF 200.6 KB
Confidentiality request letterCover Letter(s)2018-07-23PDF 298.2 KB
Declaration of conformityCover Letter(s)2018-07-23PDF 190.8 KB
MPE reportRF Exposure Info2018-07-23PDF 146.5 KB
Block diagram Metadata onlyBlock DiagramPDF 145.9 KB
Schematics Metadata onlySchematicsPDF 146.3 KB
Operational description Metadata onlyOperational DescriptionPDF 86.5 KB

Application Information

Application IDZ7ExTKYHmrbOpfgIDg1bww==
Final Action Date2018-07-23
Application PurposeOriginal Equipment
Applicant FRN0027054246
ModelHYLETON-331
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSMART POWER STRIP
Responsible PartyMei jun Zeng, General manager, 705274354@qq.com , 15815500751
Test FirmAlex Li, Shenzhen NTEK Testing Technology Co., Ltd., certification@ntek.org.cn , +86-755-6115-9384
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. This device contains 20 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
Z7ExTKYHmrbOpfgIDg1bww==2018-07-23Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.062000015C20

Grants

TCB Grant - Application Z7ExTKYHmrbOpfgIDg1bww==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/23/2018

Application Dated: 07/23/2018
Shenzhen Hyleton Technology Co.,Ltd.
4F,A3 Building,Fenghuanggang 3rd lndustry
Park,Xixiang,Baoan
shenzhen,
China
 
Attention: Mei jun Zeng , General manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AOHT-HYLETON-331
Name of Grantee:  Shenzhen Hyleton Technology Co.,Ltd.
Equipment Class: Digital Transmission System
Notes: SMART POWER STRIP
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2412.0  -  2462.0 0.062  

Output power listed is conducted. This device contains 20 MHz signal bandwidth.

The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application Z7ExTKYHmrbOpfgIDg1bww==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Hyleton Technology Co.,Ltd.
4F,A3 Building,Fenghuanggang 3rd lndustry Park,Xixiang,Baoan
shenzhen,
China
  Date of Grant: 07/23/2018

Application Dated: 07/23/2018
 
Attention: Mei jun Zeng , General manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AOHT-HYLETON-331
Name of Grantee:  Shenzhen Hyleton Technology Co.,Ltd.
Equipment Class: Digital Transmission System
Notes: SMART POWER STRIP
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2412.0  -  2462.0 0.062  

Output power listed is conducted. This device contains 20 MHz signal bandwidth.

The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

Mail To: