HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC

Remote Tech LLC keyless transmitter

Page 1 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 2 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 3 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 4 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 5 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 6 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 7 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 8 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 9 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 10 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 11 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 12 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 13 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 14 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 15 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 16 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 17 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 18 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 19 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 20 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 21 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 22 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 23 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Page 24 of HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC

Shenzhen Zhongjian Nanfang Testing Co., Ltd.
Report No: CCISE180911101
FCC/IC REPORT
Applicant:
Remote Tech LLC
Address of Applicant:
310 ALDER RD, DOVER DE 19904 USA
Equipment Under Test (EUT)
Product Name:
keyless transmitter
Model No.:
RT-HD545
FCC ID:
2AOKM-HD545
Canada IC:
24223-HD545
Applicable standards:
FCC CFR Title 47 Part 15 Subpart C,15.231
RSS-Gen Issue 5 April 2018
RSS-210 Issue 9 August 2016,Annex A
Date of sample receipt:
25 Sep., 2018
Date of Test:
25 Sep., to 11 Oct., 2018
Date of report issue:
12 Oct., 2018
Test Result:
PASS*
In the configuration tested, the EUT complied with the standards specified above.
Authorized Signature:
Bruce Zhang
Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.
This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.
This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.
Report No: CCISE180911101
Version
Version No.
Date
Description
00
12 Oct., 2018
Original
Prepared By:
Date:
12 Oct., 2018
Date:
12 Oct., 2018
Test Engineer
Check By:
Project Engineer
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 2 of 30
Report No: CCISE180911101
Contents
Page
COVER PAGE ....................................................................................................................................................... 1
VERSION ............................................................................................................................................................... 2
CONTENTS ........................................................................................................................................................... 3
TEST SUMMARY .................................................................................................................................................. 4
GENERAL INFORMATION .................................................................................................................................. 5
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
CLIENT INFORMATION ............................................................................................................................................ 5
GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
TEST MODE ............................................................................................................................................................ 5
DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 5
LABORATORY FACILITY.......................................................................................................................................... 6
LABORATORY LOCATION ....................................................................................................................................... 6
MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
TEST INSTRUMENTS LIST ....................................................................................................................................... 7
TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
6.1
ANTENNA REQUIREMENT ....................................................................................................................................... 8
6.2
RADIATED EMISSION ............................................................................................................................................. 9
6.2.1 Field Strength Of The Fundamental Signal .............................................................................................. 11
6.2.2 Spurious Emissions ..................................................................................................................................... 14
6.3
20DB BANDWIDTH ............................................................................................................................................... 19
6.4
DURATION TIME ................................................................................................................................................... 21
6.5
FREQUENCY STABILITY ....................................................................................................................................... 23
TEST SETUP PHOTOS...................................................................................................................................... 25
EUT CONSTRUCTIONAL PHOTOS ................................................................................................................. 26
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 3 of 30
Report No: CCISE180911101
Test Summary
Section in CFR 47
Test Item
Result
FCC
IC
RSS-GEN 6.8
Antenna requirement
15.203
Pass
Field strength of the fundamental signal
15.231 (b)
RSS-210 Annex A
Section A.1.2 (a)
Pass
Spurious emissions
15.231 (b)/15.209
RSS-210 Annex A
Section A.1.2 (b)
Pass
20dB and 99% Bandwidth
15.231 (c)
RSS-210 A.1.3
RSS-GEN 6.7
Pass
Duration time
15.231 (a1)
RSS-210 Annex A
Section A.1.1 (a)
Pass
Frequency stability
RSS-GEN
6.11 8.11
Pass
Conducted Emission
15.207
RSS-GEN 8.8
N/A
Remarks:
N/A: The EUT not applicable of the test item.
Pass: The EUT complies with the essential requirements in the standard.
TEST ACCORDING TO ANSI C63.4:2014 AND ANSI C63.10:2013.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 4 of 30
Report No: CCISE180911101
General Information
5.1 Client Information
Applicant:
Remote Tech LLC
Address of Applicant:
310 ALDER RD, DOVER DE 19904 USA
Manufacturer:
Remote Tech LLC
Address of Manufacturer:
310 ALDER RD, DOVER DE 19904 USA
5.2 General Description of E.U.T.
Product Name:
keyless transmitter
Model No.:
RT-HD545
Operation Frequency:
433.92MHz
Channel numbers:
Modulation type:
FSK
Antenna Type:
PCB antenna
Antenna gain:
0 dBi
Power supply:
DC 3V (CR1616 battery)
Test Sample Condition:
The test samples were provided in good working order with no visible
defects.
5.3 Test mode
Transmitting mode:
Keep the EUT in transmitting mode with modulation(new battery used)
Pre-Test Mode:
CCIS has verified the construction and function in typical operation, The EUT was placed on three different
polar directions; i.e. X axis, Y axis, Z axis. which was shown in this test report and defined as follows:
Axis
Field Strength(dBuV/m)
75.17
74.96
75.10
Final Test Mode:
According to ANSI C63.4 standards, the test results are both the “worst case” and “worst setup”: X axis
(see the test setup photo)
5.4 Description of Support Units
N/A
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 5 of 30
Report No: CCISE180911101
5.5
Laboratory Facility
The test facility is recognized, certified, or accredited by the following organizations:
 FCC - Registration No.: 727551
Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
(Federal Communications Commission). The Registration No. is 727551.
 IC - Registration No.: 10106A-1
The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
Registration No.: 10106A-1.
 CNAS - Registration No.: CNAS L6048
Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
Requirements for the Competence of Testing and Calibration laboratories for the competence of
testing. The Registration No. is CNAS L6048.
 A2LA - Registration No.: 4346.01
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
17025:2005 General requirements for the competence of testing and calibration laboratories. The test
scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf
5.6 Laboratory Location
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Tel: +86-755-23118282, Fax: +86-755-23116366
Email: info@ccis-cb.com, Website: http://www.ccis-cb.com
5.7 Measurement Uncertainty
Parameters
Conducted Emission (9kHz ~ 30MHz)
Radiated Emission (9kHz ~ 30MHz)
Radiated Emission (30MHz ~ 1000MHz)
Radiated Emission (1GHz ~ 18GHz)
Radiated Emission (18GHz ~ 40GHz)
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Expanded Uncertainty
±2.22 dB (k=2)
±2.76 dB (k=2)
±4.28 dB (k=2)
±5.72 dB (k=2)
±2.88 dB (k=2)
Project No.: CCISE1809111
Page 6 of 30
Report No: CCISE180911101
5.8 Test Instruments list
Radiated Emission:
Test Equipment
Manufacturer
Model No.
Serial No.
3m SAC
BiConiLog Antenna
Horn Antenna
Horn Antenna
Horn Antenna
SAEMC
SCHWARZBECK
SCHWARZBECK
SCHWARZBECK
SCHWARZBECK
9m*6m*6m
VULB9163
BBHA9120D
BBHA9120D
BBHA 9170
966
497
916
1805
BBHA9170582
Loop Antenna
EMI Test Software
Pre-amplifier
Pre-amplifier
Spectrum analyzer
Spectrum analyzer
SCHWARZBECK
AUDIX
HP
CD
Rohde & Schwarz
Rohde & Schwarz
FMZB 1519 B
E3
8447D
PAP-1G18
FSP30
FSP40
00044
EMI Test Receiver
Simulated Station
Cable
Cable
Cable
DC Power Supply
Temperature
Humidity Chamber
Rohde & Schwarz
Anritsu
ZDECL
MICRO-COAX
SUHNER
XinNuoEr
ESRP7
MT8820C
Z108-NJ-NJ-81
MFR64639
SUCOFLEX100
WYK-10020K
101070
6201026545
1608458
K10742-5
58193/4PE
1409050110020
HengPu
HPGDS-500
20140828008
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Cal. Date
(mm-dd-yy)
07-22-2017
03-16-2018
03-16-2018
06-22-2017
11-21-2017
04-28-2018
Version: 6.110919b
2944A09358
03-07-2018
11804
03-07-2018
101454
03-07-2018
100363
11-21-2017
03-07-2018
03-07-2018
03-07-2018
03-07-2018
03-07-2018
10-31-2017
09-24-2017
09-24-2018
Cal. Due date
(mm-dd-yy)
07-21-2020
03-15-2019
03-15-2019
06-21-2020
11-20-2018
04-27-2019
03-06-2019
03-06-2019
03-06-2019
11-20-2018
03-06-2019
03-06-2019
03-06-2019
03-06-2019
03-06-2019
10-30-2018
09-23-2018
09-23-2019
Project No.: CCISE1809111
Page 7 of 30
Report No: CCISE180911101
Test results and Measurement Data
6.1 Antenna requirement
Standard requirement:
FCC Part15 C Section 15.203
15.203 requirement:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
electrical connector is prohibited.
E.U.T Antenna:
The EUT make use of a PCB antenna, The typical gain of the antenna is 0 dBi.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 8 of 30
Report No: CCISE180911101
6.2 Radiated Emission
Test Requirement:
FCC Part15 C Section 15.231 (b)/15.209
RSS-210 Annex A Section A.1.2 (a)(b)
Test Method:
ANSI C63.10:2013
Test Frequency Range:
30MHz to 3500MHz
Test site:
Measurement Distance: 3m (Semi-Anechoic Chamber)
Receiver setup:
Frequency
Detector
RBW
VBW
30MHz-1GHz
Quasi-peak
120kHz
300kHz
Above 1GHz
Peak
1MHz
3MHz
Frequency
Limit (dBuV/m @3m)
Limit:
(Field strength of the
fundamental signal)
Limit:
(Spurious Emissions)
433.92MHz
Frequency
30MHz-88MHz
88MHz-216MHz
216MHz-960MHz
960MHz-1GHz
Above 1GHz
Test Procedure:
Remark
Quasi-peak Value
Peak Value
Remark
80.83
Average Value
100.83
Limit (dBuV/m @3m)
40.0
43.5
46.0
54.0
54.0
74.0
Peak Value
Remark
Quasi-peak Value
Quasi-peak Value
Quasi-peak Value
Quasi-peak Value
Average Value
Peak Value
Or The maximum permitted unwanted emission level is 20 dB below the
maximum permitted fundamental level whichever limit permits higher field
strength.
a. The EUT was placed on the top of a rotating table 0.8m(below 1GHz)
/1.5m(above 1GHz) above the ground at a 3 meter chamber. The
table was rotated 360 degrees to determine the position of the highest
radiation.
b. The EUT was set 3 meters away from the interference-receiving
antenna, which was mounted on the top of a variable-height antenna
tower.
c. The antenna height is varied from one meter to four meters above the
ground to determine the maximum value of the field strength. Both
horizontal and vertical polarizations of the antenna are set to make
the measurement.
d. For each suspected emission, the EUT was arranged to its worst case
and then the antenna was tuned to heights from 1 meter to 4 meters
and the rotatable table was turned from 0 degrees to 360 degrees to
find the maximum reading.
e. The test-receiver system was set to Peak Detect Function and
Specified Bandwidth with Maximum Hold Mode.
f. If the emission level of the EUT in peak mode was 10dB lower than
the limit specified, then testing could be stopped and the peak values
of the EUT would be reported. Otherwise the emissions that did not
have 10dB margin would be re-tested one by one using peak, quasipeak or average method as specified and then reported in a data
sheet.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 9 of 30
Report No: CCISE180911101
Test setup:
Below 1GHz
Above 1GHz
Test Instruments:
Refer to section 5.7 for details
Test mode:
Refer to section 5.3 for details
Test results:
Pass
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 10 of 30
Report No: CCISE180911101
6.2.1
Field Strength Of The Fundamental Signal
Peak value
Frequency
(MHz)
Read
Level
(dBuV)
Antenna
Factor
(dB/m)
Cable
Loss
(dB)
Preamp
Factor(dB)
PK Level
(dBuV/m)
AV Limit
(dBuV/m)
Over
Limit
(dB)
Polarization
433.92
41.12
15.91
3.16
0.00
60.19
80.83
-20.64
Vertical
433.92
56.10
15.91
3.16
0.00
75.17
80.83
-5.66
Horizontoal
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 11 of 30
Report No: CCISE180911101
Test Plots:
Product Name:
keyless transmitter
Product Model:
RT-HD545
Test By:
Carey
Test mode:
Tx mode
Test Frequency:
433.92 MHz
Polarization:
Vertical
Test Voltage:
DC 3V
Environment:
Temp: 24℃
Huni: 57%
Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 12 of 30
Report No: CCISE180911101
Product Name:
keyless transmitter
Product Model:
RT-HD545
Test By:
Carey
Test mode:
Tx mode
Test Frequency:
433.92 MHz
Polarization:
Horizontal
Test Voltage:
DC 3V
Environment:
Temp: 24℃
Huni: 57%
Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 13 of 30
Report No: CCISE180911101
6.2.2
Spurious Emissions
Below 1GHz (30MHz-1000MHz)
869.13
Read
Level
(dBuV/m)
16.48
Antenna
Factor
(dB/m)
21.69
Cable
Loss
(dB)
4.01
869.13
16.40
21.69
4.01
Frequency
(MHz)
Peak value
Preamp
PK Level
Factor
(dBuV/m)
(dB)
0.00
42.18
0.00
42.10
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
AV Limit
(dBuV/m)
polarization
60.83
Vertical
60.83
Horizontal
Project No.: CCISE1809111
Page 14 of 30
Report No: CCISE180911101
Test Plots:
Product Name:
keyless transmitter
Product Model:
RT-HD545
Test By:
Carey
Test mode:
Tx mode
Test Frequency:
30 MHz ~ 1 GHz
Polarization:
Vertical
Test Voltage:
DC 3V
Environment:
Temp: 24℃
Huni: 57%
Fundamental signal
Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 15 of 30
Report No: CCISE180911101
Product Name:
keyless transmitter
Product Model:
RT-HD545
Test By:
Carey
Test mode:
Tx mode
Test Frequency:
30 MHz ~ 1 GHz
Polarization:
Horizontal
Test Voltage:
DC 3V
Environment:
Temp: 24℃
Huni: 57%
Fundamental signal
Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 16 of 30
Report No: CCISE180911101
Product Name:
keyless transmitter
Product Model:
RT-HD545
Test By:
Carey
Test mode:
Tx mode
Test Frequency:
1 GHz ~ 5 GHz
Polarization:
Vertical
Test Voltage:
DC 3V
Environment:
Temp: 24℃
Huni: 57%
Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 17 of 30
Report No: CCISE180911101
Product Name:
keyless transmitter
Product Model:
RT-HD545
Test By:
Carey
Test mode:
Tx mode
Test Frequency:
1 GHz ~ 5 GHz
Polarization:
Horizontal
Test Voltage:
DC 3V
Environment:
Temp: 24℃
Huni: 57%
Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 18 of 30
Report No: CCISE180911101
6.3 20dB Bandwidth
Test Requirement:
FCC Part15 C Section 15.231 (c)
RSS-210 Annex A Section A.1.3
Test Method:
ANSI C63.10:2013
Receiver setup:
RBW=1kHz, VBW=3kHz, detector: Peak
The bandwidth of the emission shall be no wider than 0.25% of the center
frequency for devices operating above 70 MHz and below 900 MHz. For
devices operating above 900 MHz, the emission shall be no wider than
0.5% of the center frequency. Bandwidth is determined at the points 20
dB down from the modulated carrier.
1. According to the follow Test-setup, keep the relative position between
the artificial antenna and the EUT.
2. Set the EUT to proper test channel.
3. Max hold the radiated emissions, mark the peak power frequency
point and the -20dB upper and lower frequency points.
4. Read 20dB bandwidth.
Limit:
Test Procedure:
Test setup:
Test Instruments:
Refer to section 5.7 for details
Test mode:
Refer to section 5.3 for details
Test results:
Passed
Measurement Data:
20dB bandwidth (MHz)
Limit (MHz)
99% Occupy Bandwidth (MHz)
Results
0.108
1.0848
0.097
Passed
Note: 20dB bandwidth Limit= Fundamental frequency×0.25%=433.92×0.25%=1.0848MHz
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 19 of 30
Report No: CCISE180911101
Test plot as follows:
20dB Bandwidth
Ref
5 dBm
Offset
* Att
* RBW
1 kHz
* VBW
3 kHz
10 dB
SWT 500 ms
5 dB
Delta 1 [T1 ]
-2.59 dB
108.000000000 kHz
Marker 1 [T1 ]
-26.44 dBm
433.828000000 MHz
D1 -5.7 dBm
1 PK
-10
MAXH
LVL
-20
D2 -25.7 dBm
-30
-40
-50
3DB
AC
-60
-70
-80
-90
Center 433.92 MHz
Date: 27.SEP.2018
50 kHz/
Span 500 kHz
20:57:04
99% Occupy Bandwidth
* RBW
1 kHz
VBW 3 kHz
Ref
5 dBm
Offset
Att
15 dB
SWT 500 ms
5 dB
-8.75 dBm
433.925000000 MHz
OBW 97.000000000 kHz
Temp 1 [T1 OBW]
1 PK
Marker 1 [T1 ]
-28.23 dBm
433.831000000 MHz
-10
Temp 2 [T1 OBW]
MAXH
-22.99 dBm LVL
T2
-20
433.928000000 MHz
T1
-30
-40
-50
3DB
AC
-60
-70
-80
-90
Center 433.92 MHz
Date: 30.SEP.2018
50 kHz/
Span 500 kHz
20:50:54
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 20 of 30
Report No: CCISE180911101
6.4 Duration Time
Test Requirement:
FCC Part15 C Section 15.231 (a1)
RSS-210 Annex A Section A.1.1 (a)
Test Method:
ANSI C63.10: 2013
Receiver setup:
RBW=1MHz, VBW=1MHz, span=0Hz, detector: Peak
Limit:
Not more than 5 seconds
Test mode:
Transmitting mode
Test Procedure:
1. According to the follow Test-setup, keep the relative position between
the artificial antenna and the EUT.
2. Set the EUT to proper test channel.
3. Single scan the transmission, and read the transmission time.
Test setup:
Test Instruments:
Refer to section 5.8 for details
Test mode:
Refer to section 5.3 for details
Test results:
Passed
Measurement Data
Duration time (second)
Limit (second)
Result
0.288
<5.0
Pass
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 21 of 30
Report No: CCISE180911101
Test plot as follows:
RBW 1 MHz
* VBW
Ref
5 dBm
Offset
* Att
10 dB
Delta 2 [T1 ]
1 MHz
0.67 dB
SWT 8 s
5.000000 s
5 dB
Marker 1 [T1 ]
-68.45 dBm
464.000000 ms
1 PK *
Delta 1 [T1 ]
-10
SGL
-1.42 dB
CLRWR
288.000000 ms
LVL
-20
-30
-40
-50
3DB
AC
-60
-70
-80
-90
Center 433.92 MHz
Date: 27.SEP.2018
800 ms/
17:48:00
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 22 of 30
Report No: CCISE180911101
6.5 Frequency Stability
Test Requirement:
RSS-GEN Section 8.11
Test Method:
RSS-GEN Section 6.11
kept within at least the central 80% of its permitted operating frequency
band.
Limit:
Test setup:
Test procedure:
1.
2.
3.
4.
5.
The EUT is installed in an environment test chamber with external
power source.
Set the chamber to operate at 50 centigrade and external power
source to output at nominal voltage of EUT.
A sufficient stabilization period at each temperature is used prior to
each frequency measurement.
When temperature is stabled, measure the frequency stability.
The test shall be performed under -20 to 50 centigrade and 85 to
115 percent of the nominal voltage. Change setting of chamber
and external power source to complete all conditions.
Test Instruments:
Refer to section 5.7 for details
Test mode:
Unmodulated carrier is not available, test at modulated carrier mode.
Test results:
Passed
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 23 of 30
Report No: CCISE180911101
Measurement Data:
Voltage vs. Frequency Stability
Test conditions
Temp(℃)
Voltage(ac)
Measurement Frequency (MHz)
Limit (MHz)
433.8370
433.8363
433.8360
281 ~ 449
3.2V
3.0V
2.5V
20
Note: EUT stops working when the supply voltage is lower than DC 2.5V.
Temperature vs. Frequency Stability
Test conditions
Temp(℃)
Voltage(dc)
Frequency(MHz)
Limit (MHz)
433.8370
433.8366
433.8368
433.8365
433.8363
433.8362
433.8364
433.8360
281 ~ 449
-20
-10
10
20
30
40
50
3.0V
Test plot as follows (worst case):
Ref
5 dBm
Offset
Att
30 dB
* RBW
1 kHz
* VBW
1 kHz
SWT 500 ms
Marker 1 [T1 ]
-7.43 dBm
433.837000000 MHz
5 dB
1 PK
-10
MAXH
LVL
-20
-30
-40
-50
3DB
-60
-70
-80
-90
Center 433.92 MHz
Date: 29.SEP.2018
50 kHz/
Span 500 kHz
19:46:26
Shenzhen Zhongjian Nanfang Testing Co., Ltd.
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366
Project No.: CCISE1809111
Page 24 of 30
Download: HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Mirror Download [FCC.gov]HD545 keyless transmitter Test Report HD 271 S1 Remote Tech LLC
Document ID4064132
Application IDv5KSDW0TbSdCKHGaJ6ikDg==
Document DescriptionTest report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize204.84kB (2560441 bits)
Date Submitted2018-11-08 00:00:00
Date Available2018-11-08 00:00:00
Creation Date2018-10-30 15:53:30
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2018-11-08 13:17:40
Document TitleHD 271 S1
Document CreatorMicrosoft® Word 2010
Document Author: LAB02

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : LAB02
Create Date                     : 2018:10:30 15:53:30+08:00
Modify Date                     : 2018:11:08 13:17:40+08:00
Has XFA                         : No
Language                        : zh-CN
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Format                          : application/pdf
Creator                         : LAB02
Title                           : HD 271 S1
Creator Tool                    : Microsoft® Word 2010
Metadata Date                   : 2018:11:08 13:17:40+08:00
Producer                        : Microsoft® Word 2010
Document ID                     : uuid:0b9c5494-7946-4b1d-872f-4afbd425c9cc
Instance ID                     : uuid:408f51e2-a23d-4cda-b538-341306a261c7
Page Count                      : 24