FCC ID 2AOKWBT-058

iMeter BT Flow Meter

by Savant Electronics Inc.

Grantee Code: 2AOKW   Product Code: BT058
Latest application date: 2018-01-09

FCC ID Device Details

FCC ID2AOKWBT-058
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AOKW
Product CodeBT058
Applicant BusinessSavant Electronics Inc. 🇹🇼
Related Domains ms65.hinet.net
Equipment ClassiMeter BT Flow Meter
Test FirmBureau Veritas CPS (H.K.) Ltd., Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2018-01-09

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2018-01-09PDF 385.3 KB
Internal PhotosInternal Photos2018-01-09PDF 1.1 MB
External PhotosExternal Photos2018-01-09PDF 245.8 KB
Label & Label LocationID Label/Location Info2018-01-09PDF 122.1 KB
RF Test Set-up PhotosTest Setup Photos2018-01-09PDF 268.8 KB
RF Test ReportTest Report2018-01-09PDF 479.8 KB
Authorization LetterCover Letter(s)2018-01-09PDF 77.3 KB
LTC LetterCover Letter(s)2018-01-09PDF 89.8 KB
RF Exposure ReportRF Exposure Info2018-01-09PDF 190.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 1.7 MB
Schematics Metadata onlySchematicsPDF 468.9 KB
Operational Description Metadata onlyOperational DescriptionPDF 22.4 KB

Application Information

Application IDAktaeDhN5PM2/EELABxkZg==
Final Action Date2018-01-09
Application PurposeOriginal Equipment
Applicant FRN0027078864
ModelBT-058
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptioniMeter BT Flow Meter
Responsible PartyGeorge Liang, General Manager, savantco@ms65.hinet.net , 04-24255578
Test FirmRichard Chen, Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch, richard.chen@bureauveritas.com , +886-3-2600884
TCB Emailtcb@siemic.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is maximum conducted output power. Responsible parties must be provided operating instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines.

Applications

Application IDDatePurpose
AktaeDhN5PM2/EELABxkZg==2018-01-09Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.001000015C

Grants

TCB Grant - Application AktaeDhN5PM2/EELABxkZg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 01/09/2018

Application Dated: 01/09/2018
Savant Electronics Inc.
No.2088-3,Sec 1,Huanzhong Rd.,Xitun Dist.,
Taichung City, 40761
Taiwan
 
Attention: George Liang , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AOKWBT-058
Name of Grantee:  Savant Electronics Inc.
Equipment Class: Digital Transmission System
Notes: iMeter BT Flow Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.001  

Power listed is maximum conducted output power. Responsible parties must be provided operating instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines.

EAS Grant - Application AktaeDhN5PM2/EELABxkZg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Savant Electronics Inc.
No.2088-3,Sec 1,Huanzhong Rd.,Xitun Dist.,
Taichung City, 40761
Taiwan
  Date of Grant: 01/09/2018

Application Dated: 01/09/2018
 
Attention: George Liang , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AOKWBT-058
Name of Grantee:  Savant Electronics Inc.
Equipment Class: Digital Transmission System
Notes: iMeter BT Flow Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.001  

Power listed is maximum conducted output power. Responsible parties must be provided operating instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines.



Mail To: