FCC ID 2AOLI-SBC007
Dual Alarm Clock Radio
by Shenzhen Chufan E-Commerce Limited Company
Grantee Code: 2AOLI Product Code: SBC007
Latest application date: 2017-12-28
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2017-12-28 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2017-12-28 | PDF 3.2 MB |
| Internal photos | Internal Photos | 2017-12-28 | PDF 785.6 KB |
| External photos | External Photos | 2017-12-28 | PDF 601.8 KB |
| Label | ID Label/Location Info | 2017-12-28 | PDF 69.5 KB |
| Test setup photos | Test Setup Photos | 2017-12-28 | PDF 145 KB |
| Test report 1 | Test Report | 2017-12-28 | PDF 4.3 MB |
| Test report 2 | Test Report | 2017-12-28 | PDF 5.3 MB |
| Authorization letter | Cover Letter(s) | 2017-12-28 | PDF 14.3 KB |
| Confidentiality request letter | Cover Letter(s) | 2017-12-28 | PDF 22.8 KB |
| Family model declaration | Cover Letter(s) | 2017-12-28 | PDF 13.8 KB |
| RF exposure | RF Exposure Info | 2017-12-28 | PDF 37.3 KB |
| Block Diagram Metadata only | Block Diagram | PDF 73.4 KB | |
| Schematics Metadata only | Schematics | PDF 935.9 KB | |
| Operational description Metadata only | Operational Description | PDF 249.6 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 9.6 KB |
Application Information
| Application ID | mMyR/9luqHj4n18AVHrNDg== |
|---|---|
| Final Action Date | 2017-12-28 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0027084136 |
| Model | SBC007 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | Dual Alarm Clock Radio |
| Responsible Party | ANDY Li, Manager, purchase@svinz.com |
| Technical Contact | Joe Zhou, Shenzhen Tongce Testing Lab, joe.zhou@tct-lab.com |
| Test Firm | Beryl Zhao, SHENZHEN TONGCE TESTING LAB, berylzhao@tct-lab.com |
| TCB Email | micomlabs_certification@micomlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| mMyR/9luqHj4n18AVHrNDg== | 2017-12-28 | Original Equipment |
Grants
TCB Grant - Application mMyR/9luqHj4n18AVHrNDg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 12/28/2017 Application Dated: 12/28/2017 |
| Shenzhen Chufan E-Commerce Limited Company |
| 1601-1602 Room, A Block, South |
| International Plaza, Yitian Road, Futian, |
| Shenzhen, Guangdong, China |
| Attention: ANDY Li , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AOLI-SBC007 |
| Name of Grantee: | Shenzhen Chufan E-Commerce Limited Company |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Dual Alarm Clock Radio |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 20 | 15C | 2402.0 - 2480.0 | 0.0018 |
| Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| 20: | All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed. |
EAS Grant - Application mMyR/9luqHj4n18AVHrNDg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Chufan E-Commerce Limited Company 1601-1602 Room, A Block, South International Plaza, Yitian Road, Futian, Shenzhen, Guangdong, China |
Date of Grant: 12/28/2017 Application Dated: 12/28/2017 |
| Attention: ANDY Li , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AOLI-SBC007 |
| Name of Grantee: | Shenzhen Chufan E-Commerce Limited Company |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Dual Alarm Clock Radio |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 20 | 15C | 2402.0 - 2480.0 | 0.0018 |
| Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| 20: | All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed. |
| Mail To: |