FCC ID 2AOVG-K3D

Smart Access Controller

by Hangzhou Sciener Smart Technology Co., Ltd.

Grantee Code: 2AOVG   Product Code: K3D
Latest application date: 2025-12-02

FCC ID Device Details

FCC ID2AOVG-K3D
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AOVG
Product CodeK3D
Applicant BusinessHangzhou Sciener Smart Technology Co., Ltd. 🇨🇳
Related Domains sciener.cn
Equipment ClassSmart Access Controller
Test FirmGuangdong Zhonghan Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
13.56 MHzOriginal Equipment2025-12-02
2412-2462 MHzOriginal Equipment2025-12-02

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2025-12-02PDF 759.4 KB
Internal PhotosInternal Photos2025-12-02PDF 2.5 MB
External PhotosExternal Photos2025-12-02PDF 2.2 MB
Label and Label locationID Label/Location Info2025-12-02PDF 423.6 KB
Test Setup PhotoTest Setup Photos2025-12-02PDF 1.7 MB
Test ReportTest Report2025-12-02PDF 4.9 MB
Test ReportTest Report2025-12-02PDF 1.4 MB
Attestation Statements of US Agent for Service of Process, 2.911(d)(7)Attestation Statements2025-12-02PDF 145.6 KB
Attestation of Covered Equipment, 2.911(d)(5)(i)(ii)Attestation Statements2025-12-02PDF 101.3 KB
ANT ReportCover Letter(s)2025-12-02PDF 213.1 KB
ANT ReportCover Letter(s)2025-12-02PDF 293.9 KB
Agent Authorization Letter TemplateCover Letter(s)2025-12-02PDF 100.1 KB
FCC Short & Long Term Confidentiality RequestCover Letter(s)2025-12-02PDF 65.9 KB
RF ExposureRF Exposure Info2025-12-02PDF 236.5 KB
Block Diagram Metadata onlyBlock DiagramPDF 72.7 KB
SCH Metadata onlySchematicsPDF 556.1 KB
OPS Metadata onlyOperational DescriptionPDF 47.1 KB

Application Information

Application IDxPbLXhZgNxJzGqi+j2f7vA==
Final Action Date2025-12-02
Application PurposeOriginal Equipment
Applicant FRN0027160696
ModelK3D
Frequency Range13.56 MHz
Equipment ClassDXX - Part 15 Low Power Communication Device Transmitter
Device DescriptionSmart Access Controller
Responsible PartyBaohong Wan, wumangui@sciener.cn , 0571-88690590
Technical ContactHangzhou Sciener Smart Technology Co., Ltd., wumangui@sciener.cn
Test FirmAlex Wang, Guangdong Zhonghan Testing Technology Co., Ltd., alex_wang_zht@163.com , 86-18307618653
TCB Emailanezam@qai.org
TCB ScopeA1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
xPbLXhZgNxJzGqi+j2f7vA==2025-12-02Original Equipment
6TQznlnOpNOzzV3eMhE6eA==2025-12-02Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
13.56 MHz15CCC
2412-2462 MHz0.154515CCC
2402-2480 MHz0.001915CCC

Grants

TCB Grant - Application xPbLXhZgNxJzGqi+j2f7vA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  QAI LABORATORIES LTD
3980 North Fraser Way
Burnaby, BC, V5J5K5
Canada
Date of Grant: 12/02/2025

Application Dated: 12/02/2025
Hangzhou Sciener Smart Technology Co., Ltd.
Room 1101,Building A2
2-150#, Yunlian Road, Yuhang District
Hangzhou, Zhejiang Province, PRC 311121,
China
 
Attention: Baohong Wan ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AOVG-K3D
Name of Grantee:  Hangzhou Sciener Smart Technology Co., Ltd.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Smart Access Controller
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 6TQznlnOpNOzzV3eMhE6eA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  QAI LABORATORIES LTD
3980 North Fraser Way
Burnaby, BC, V5J5K5
Canada
Date of Grant: 12/02/2025

Application Dated: 12/02/2025
Hangzhou Sciener Smart Technology Co., Ltd.
Room 1101,Building A2
2-150#, Yunlian Road, Yuhang District
Hangzhou, Zhejiang Province, PRC 311121,
China
 
Attention: Baohong Wan ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AOVG-K3D
Name of Grantee:  Hangzhou Sciener Smart Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Smart Access Controller
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.1545  
CC 15C 2402.0  -  2480.0 0.0019  

Power listed is the maximum conducted output power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.