FCC ID 2AOX8-F1200

Flume Intelligent Water Monitoring System (Bridge)

by Flume Inc.

Grantee Code: 2AOX8   Product Code: F1200
Latest application date: 2018-02-22

FCC ID Device Details

FCC ID2AOX8-F1200
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AOX8
Product CodeF1200
Applicant BusinessFlume Inc. 🇺🇸
Related Domains flumetech.com
Equipment ClassFlume Intelligent Water Monitoring System (Bridge)
Test FirmBureau Veritas Consumer Products Services, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902-928 MHzOriginal Equipment2018-02-22

Exhibits

DocumentTypeAvailableFile
Electronic User Manual InformationCover Letter(s)2018-02-22PDF 80.5 KB
End User License AgreementUsers Manual2018-02-22PDF 119.5 KB
User ManualUsers Manual2018-02-22PDF 397.4 KB
Internal PhotoInternal Photos2018-02-22PDF 385 KB
External PhotoExternal Photos2018-02-22PDF 262.1 KB
Product LabelID Label/Location Info2018-02-22PDF 899.3 KB
Test Setup PhotoTest Setup Photos2018-02-22PDF 368.8 KB
2.4GHz Test Report Metadata onlyTest Report2018-02-22PDF 1.3 MB
2.4GHz Test Report (Co-location)Test Report2018-02-22PDF 1.3 MB
UHF-RFID Test ReportTest Report2018-02-22PDF 1.8 MB
Confidentiality Request LetterCover Letter(s)2018-02-22PDF 66.8 KB
Project and Product Certification Representative Authorization LetterCover Letter(s)2018-02-22PDF 29.7 KB
MPE CalculationRF Exposure Info2018-02-22PDF 85.8 KB
Block Diagram Metadata onlyBlock DiagramPDF 48.8 KB
Schematics Metadata onlySchematicsPDF 48.1 KB
Operation Description Metadata onlyOperational DescriptionPDF 397.4 KB

Application Information

Application ID3GJkNzLT5J2xUAksjQb+4g==
Final Action Date2018-02-22
Application PurposeOriginal Equipment
Applicant FRN0027192228
ModelF1200
Frequency Range902-928 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionFlume Intelligent Water Monitoring System (Bridge)
Responsible PartyR Alan Beverly, VP Engineering, abeverly@flumetech.com , (805)234-3711
Test FirmSarb Shelopal, Bureau Veritas Consumer Products Services, Inc., Sarbjit.Shelopal@bureauveritas.com , +1 925 963 4420
TCB Emailtcb@siemic.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
3GJkNzLT5J2xUAksjQb+4g==2018-02-22Original Equipment

Equipment Authorization

FrequencyOutputRules
902-928 MHz0.034000015C

Grants

TCB Grant - Application 3GJkNzLT5J2xUAksjQb+4g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 02/22/2018

Application Dated: 02/21/2018
Flume Inc.
872 Higuera St.
P.O. Box 93401,
San Luis Obispo, CA 93401
 
Attention: R Alan Beverly , VP Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AOX8-F1200
Name of Grantee:  Flume Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Flume Intelligent Water Monitoring System (Bridge)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.0  -  928.0 0.034  

Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application 3GJkNzLT5J2xUAksjQb+4g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Flume Inc.
872 Higuera St. P.O. Box 93401,
San Luis Obispo, CA 93401
United States
  Date of Grant: 02/22/2018

Application Dated: 02/21/2018
 
Attention: R Alan Beverly , VP Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AOX8-F1200
Name of Grantee:  Flume Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Flume Intelligent Water Monitoring System (Bridge)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.0  -  928.0 0.034  

Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.



Mail To: