R1LTC Router miner Test Report ShenZhen Century Cloud Core Technologies Limited

ShenZhen Century Cloud Core Technologies Limited Router miner

Page 1 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 2 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 3 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 4 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 5 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 6 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 7 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 8 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 9 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 10 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 11 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 12 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 13 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 14 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 15 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 16 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 17 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 18 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 19 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 20 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 21 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 22 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 23 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 24 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 25 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 26 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 27 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 28 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 29 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 30 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 31 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 32 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 33 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 34 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 35 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 36 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 37 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 38 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 39 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 40 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 41 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 42 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 43 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 44 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 45 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 46 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 47 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 48 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 49 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 50 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 51 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 52 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 53 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 54 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 55 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 56 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 57 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 58 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Page 59 of R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited

Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 1 of 59 Report No.:SZAWW180112002-01
FCC TEST REPORT
For
ShenZhen Century Cloud Core Technologies Limited
Router miner
Model No.: R1_LTC, R1_DASH, R1_SIA
Prepared For
: ShenZhen Century Cloud Core Technologies Limited
Address
Prepared By
: Shenzhen Anbotek Compliance Laboratory Limited
Address
: 1/F, Building D, Sogood Science and Technology Park, Sanwei
community, Hangcheng Street, Bao'an District, Shenzhen, Guangdong,
China.518102
Building 7, Pengcheng Huihe Zhizao Innovation Park, Shajing Street,
Bao'an District, Shenzhen, China 518340
Tel: (86)755-26066365
Report Number
: SZAWW180112002-01
Date of Test
: Jan. 12~Feb. 02, 2018
Date of Report
: Feb. 02, 2018
Fax: (86)755-26014772
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 2 of 59 Report No.:SZAWW180112002-01
Contents
1. General Information......................................................................................................................... 5
1.1. Client Information................................................................................................................. 5
1.2. Description of Device (EUT)................................................................................................ 5
1.3. Auxiliary Equipment Used During Test................................................................................5
1.4. Description of Test Modes.................................................................................................... 6
1.5. List of channels......................................................................................................................7
1.6. Description Of Test Setup..................................................................................................... 8
1.7. Test Equipment List.............................................................................................................. 9
1.8. Measurement Uncertainty................................................................................................... 10
1.9. Description of Test Facility................................................................................................. 10
2. Summary of Test Results................................................................................................................11
3. Conducted Emission Test............................................................................................................... 12
3.1. Test Standard and Limit...................................................................................................... 12
3.2. Test Setup............................................................................................................................ 12
3.3. Test Procedure..................................................................................................................... 12
3.4. Test Data..............................................................................................................................12
4. Radiation Spurious Emission and Band Edge................................................................................ 17
4.1. Test Standard and Limit...................................................................................................... 17
4.2. Test Setup............................................................................................................................ 17
4.3. Test Procedure..................................................................................................................... 18
4.4. Test Data..............................................................................................................................19
5. Maximum Peak Output Power Test............................................................................................... 27
5.1. Test Standard and Limit...................................................................................................... 27
5.2. Test Setup............................................................................................................................ 27
5.3. Test Procedure..................................................................................................................... 27
5.4. Test Data..............................................................................................................................27
6. 6DB Occupy Bandwidth Test.........................................................................................................30
6.1. Test Standard and Limit...................................................................................................... 30
6.2. Test Setup............................................................................................................................ 30
6.3. Test Procedure..................................................................................................................... 30
6.4. Test Data..............................................................................................................................30
7. Power Spectral Density Test.......................................................................................................... 35
7.1. Test Standard and Limit...................................................................................................... 35
7.2. Test Setup............................................................................................................................ 35
7.3. Test Procedure..................................................................................................................... 35
7.4. Test Data..............................................................................................................................35
8. 100kHz Bandwidth of Frequency Band Edge Requirement.......................................................... 39
8.1. Test Standard and Limit...................................................................................................... 39
8.2. Test Setup............................................................................................................................ 39
8.3. Test Procedure..................................................................................................................... 39
8.4. Test Data..............................................................................................................................39
9. Antenna Requirement..................................................................................................................... 46
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 3 of 59 Report No.:SZAWW180112002-01
9.1. Test Standard and Requirement...........................................................................................46
9.2. Antenna Connected Construction........................................................................................46
APPENDIX I -- TEST SETUP PHOTOGRAPH...............................................................................47
APPENDIX II -- EXTERNAL PHOTOGRAPH............................................................................... 49
APPENDIX III -- INTERNAL PHOTOGRAPH...............................................................................52
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 4 of 59 Report No.:SZAWW180112002-01
TEST REPORT
Applicant
: ShenZhen Century Cloud Core Technologies Limited
Manufacturer
: ShenZhen Century Cloud Core Technologies Limited
Product Name
: Router miner
Model No.
: R1_LTC, R1_DASH, R1_SIA
Trade Mark
Rating(s)
Test Standard(s)
: FCC Part15 Subpart C 2017, Section 15.247
Test Method(s)
: ANSI C63.10: 2013, KDB558074 D01 DTS Meas Guidance v04
Input: AC 100-240V, 50-60Hz, 0.2A
Output: DC 5V, 1A
The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to
determine the maximum emission levels emanating from the device and the severe levels of the
device can endure and its performance criterion. The measurement results are contained in this test
report and Shenzhen Anbotek Compliance Laboratory Limited is assumed full of responsibility for
the accuracy and completeness of these measurements. Also, this report shows that the EUT
(Equipment Under Test) is technically compliant with the FCC Part 15 Subpart C requirements.
This report applies to above tested sample only and shall not be reproduced in part without written
approval of Shenzhen Anbotek Compliance Laboratory Limited.
Date of Test :
Jan. 12~Feb. 02, 2018
Prepared by :
(Tested Engineer / Winkey Wang)
Reviewer :
(Project Manager /Tangcy. T)
Approved & Authorized Signer :
(Manager / Tom Chen)
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 5 of 59 Report No.:SZAWW180112002-01
1. General Information
1.1. Client Information
Applicant
: ShenZhen Century Cloud Core Technologies Limited
Address
Manufacturer
: ShenZhen Century Cloud Core Technologies Limited
Address
Building 7, Pengcheng Huihe Zhizao Innovation Park, Shajing Street,
Bao'an District, Shenzhen, China 518340
Building 7, Pengcheng Huihe Zhizao Innovation Park, Shajing Street,
Bao'an District, Shenzhen, China 518340
1.2. Description of Device (EUT)
Product Name
: Router miner
Model No.
R1_LTC, R1_DASH, R1_SIA
(Note: All samples are the same except the main chip, R1_LTC is for
BM1485, R1_DASH is for BM1760, R1_SIA is for BM1720, so we
prepare "R1_LTC" for test only.)
Trade Mark
Test Power
Supply
: AC 120V, 60Hz for adapter/AC 240V, 60Hz for adapter
Product
Description
Operation Frequency:
802.11b/ g 2412-2462MHz
Number of Channel:
11 Channels for 802.11b/ g
: Modulation Type:
802.11b CCK; 802.11g OFDM
Antenna Type:
PIFA Antenna
Antenna Gain(Peak):
0.7 dBi
Remark: 1)For a more detailed features description, please refer to the manufacturer’s
specifications or the User’s Manual.
1.3. Auxiliary Equipment Used During Test
Adapter
With
: N/A
Load
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 6 of 59 Report No.:SZAWW180112002-01
1.4. Description of Test Modes
To investigate the maximum EMI emission characteristics generates from EUT, the test system was
pre-scanning tested base on the consideration of following EUT operation mode or test
configuration mode which possible have effect on EMI emission level. Each of these EUT
operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.
RADIATED EMISSION TEST (BELOW 1GHz):
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
between available modulations, data rates, XYZ axis and antenna ports (if EUT with antenna
diversity architecture).
Following channel(s) was (were) selected for the final test as listed below.
Available
Test
Modulation
Modulation
Channel
Channel
Tech.
Type
802.11b
1 to 11
CCK
DBPSK
For the test results, only the worst case was shown in test report.
Mode
Data Rate
(Mbps)
1.0
RADIATED EMISSION TEST (ABOVE 1GHz):
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
between available modulations, data rates, XYZ axis and antenna ports (if EUT with antenna
diversity architecture).
Following channel(s) was (were) selected for the final test as listed below.
Mode
802.11b
802.11g
Available
Channel
1 to 11
1 to 11
Test
Channel
1, 6, 11
1, 6, 11
Modulation
Tech.
CCK
OFDM
Modulation Data Rate
Type
(Mbps)
DBPSK
1.0
BPSK
6.0
POWER LINE CONDUCTED EMISSION TEST:
The EUT was tested with the following mode
EUT configure mode
Test Mode
Keeping TX+Charging mode
BANDEDGE MEASUREMENT:
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
between available modulations, data rates and antenna ports (if EUT with antenna diversity
architecture).
Following channel(s) was (were) selected for the final test as listed below.
Available
Test
Modulation
Modulation Data Rate
Mode
Channel
Channel
Tech.
Type
(Mbps)
802.11b
1 to 11
1, 11
CCK
DBPSK
1.0
802.11g
1 to 11
1, 11
OFDM
BPSK
6.0
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 7 of 59 Report No.:SZAWW180112002-01
ANTENNA PORT CONDUCTED MEASUREMENT:
This item includes all test value of each mode, but only includes spectrum plot of worst value of
each mode.
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
between available modulations, data rates and antenna ports (if EUT with antenna diversity
architecture).
Following channel(s) was (were) selected for the final test as listed below.
Mode
802.11b
802.11g
Available
Test
Modulation Modulation Data Rate
Channel Channel
Tech.
Type
(Mbps)
1 to 11
1, 6, 11
CCK
DBPSK
1.0
1 to 11
1, 6, 11
OFDM
BPSK
6.0
1.5. List of channels
Channel
01
02
03
Freq.
(MHz)
2412
2417
2422
Channel
04
05
06
Freq.
(MHz)
2427
2432
2437
Channel
07
08
09
Freq.
(MHz)
2442
2447
2452
Channel
10
11
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Freq.
(MHz)
2457
2462
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 8 of 59 Report No.:SZAWW180112002-01
1.6. Description Of Test Setup
CE
E-2
Load
E-1
EUT
AC Line
LISN
0.8m
Table
Table
1.5m
RE
E-1
EUT
AC Line
0.8m
Table
1.5m
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 9 of 59 Report No.:SZAWW180112002-01
1.7. Test Equipment List
Last Cal.
Cal.
Interval
Item
Equipment
Manufacturer
Model No.
Serial No.
1.
L.I.S.N.
Artificial Mains
Network
Rohde & Schwarz
ENV216
100055
Nov. 17, 2017 1 Year
ESCI
100627
Nov. 17, 2017 1 Year
2.
EMI Test Receiver Rohde & Schwarz
3.
RF Switching Unit
Compliance
Direction
RSU-M2
38303
Nov. 17, 2017 1 Year
4.
Spectrum Analysis
Agilent
E4407B
US39390582
Nov. 17, 2017 1 Year
5.
Spectrum Analysis
Agilent
N9038A
MY53227295 Nov. 17, 2017 1 Year
6.
Preamplifier
SKET Electronic
BK1G18G3
0D
KD17503
Nov. 17, 2017 1 Year
ESPI
101604
Nov. 17, 2017 1 Year
GTH-0118
351600
Nov. 20, 2017 1 Year
7.
8.
9.
EMI Test Receiver Rohde & Schwarz
Double Ridged
Horn Antenna
Bilog Broadband
Antenna
Instruments
corporation
Schwarzbeck
VULB9163 VULB 9163-289 Nov. 20, 2017 1 Year
10.
Loop Antenna
Schwarzbeck
HFH2-Z2
100047
Nov. 17, 2017 1 Year
11.
Horn Antenna
Schewarzbeck
BBHA9170
9170-375
Nov. 17, 2017 1 Year
12.
Pre-amplifier
SONOMA
310N
186860
Nov. 17, 2017 1 Year
SHURPLE
N/A
N/A
YIHENG
YH3000
2017430
EMI Test Software
EZ-EMC
RF Test Control
14.
System
13.
N/A
N/A
Nov. 18, 2017 1 Year
15.
Power Sensor
DAER
RPR3006W 15I00041SN045 Nov. 17, 2017 1 Year
16.
Power Sensor
DAER
RPR3006W 15I00041SN046 Nov. 17, 2017 1 Year
17.
18.
MXA Spectrum
Analysis
MXG RF Vector
Signal Generator
Agilent
N9020A
MY51170037 Nov. 18, 2017 1 Year
Agilent
N5182A
MY48180656 Nov. 18, 2017 1 Year
MY41000743 Nov. 18, 2017 1 Year
19.
Signal Generator
Agilent
E4421B
20.
DC Power Supply
LW
TPR-6410D
349315
Nov. 01, 2017 1 Year
21.
Constant
Temperature
Humidity Chamber
Sertep
ZJ-HWHS8
0B
ZJ-17042804
Nov. 01, 2017 1 Year
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 10 of 59 Report No.:SZAWW180112002-01
1.8. Measurement Uncertainty
Radiation Uncertainty
: Ur = 4.1 dB (Horizontal)
Ur = 4.3 dB (Vertical)
Conduction Uncertainty
: Uc = 3.4dB
1.9. Description of Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
FCC-Registration No.: 184111
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registed and fully
described in a report filed with the (FCC) Federal Communications Commission. The acceptance
letter from the FCC is maintained in our files. Registration No. 184111, July 31, 2017.
ISED-Registration No.: 8058A-1
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully
described in a report filed with the (ISED) Innovation, Science and Economic Development Canada.
The acceptance letter from the ISED is maintained in our files. Registration 8058A-1, June 13,
2016.
Test Location
All Emissions tests were performed at
Shenzhen Anbotek Compliance Laboratory Limited. at 1/F, Building D, Sogood Science and
Technology Park, Sanwei community, Hangcheng Street, Bao'an District, Shenzhen, Guangdong,
China.518102
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 11 of 59 Report No.:SZAWW180112002-01
2. Summary of Test Results
Standard Section
Test Item
Result
15.203/15.247(c)
Antenna Requirement
PASS
15.207
Conducted Emission
PASS
15.205/15.209
Spurious Emission
PASS
15.247(b)(3)
Conducted Peak Output Power
PASS
15.247(a)(2)
6dB Occupied Bandwidth
PASS
15.247(e)
Power Spectral Density
PASS
15.247(d)
Band Edge
PASS
Remark: “N/A” is an abbreviation for Not Applicable.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 12 of 59 Report No.:SZAWW180112002-01
3. Conducted Emission Test
3.1. Test Standard and Limit
Test Standard
FCC Part15 Section 15.207
Frequency
Test Limit
Maximum RF Line Voltage (dBuV)
Quasi-peak Level
Average Level
150kHz~500kHz
66 ~ 56 *
56 ~ 46 *
500kHz~5MHz
56
46
5MHz~30MHz
60
50
Remark: (1) *Decreasing linearly with logarithm of the frequency.
(2) The lower limit shall apply at the transition frequency.
3.2. Test Setup
3.3. Test Procedure
The EUT system is connected to the power mains through a line impedance stabilization network
(L.I.S.N.). This provides a 50ohm coupling impedance for the EUT system. Please refer the block
diagram of the test setup and photographs. Both sides of AC line are checked to find out the
maximum conducted emission. In order to find the maximum emission levels, the relative positions
of equipment and all of the interface cables shall be changed according to FCC ANSI C63.10-2013
on Conducted Emission Measurement.
The bandwidth of test receiver (ESCI) set at 9kHz.
The frequency range from 150kHz to 30MHz is checked.
3.4. Test Data
Please to see the following pages
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 13 of 59 Report No.:SZAWW180112002-01
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Keeping TX+Charging mode
Test Specification:
AC 120V, 60Hz via adapter
Comment:
Live Line
Tem.:24.8℃ Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 14 of 59 Report No.:SZAWW180112002-01
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Keeping TX+Charging mode
Test Specification:
AC 120V, 60Hz via adapter
Neutral Line
Comment:
Tem.:24.8℃ Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 15 of 59 Report No.:SZAWW180112002-01
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Keeping TX+Charging mode
Test Specification:
AC 240V, 60Hz via adapter
Comment:
Live Line
Tem.:24.8℃ Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 16 of 59 Report No.:SZAWW180112002-01
Conducted Emission Test Data
Test Site:
1# Shielded Room
Operating Condition:
Keeping TX+Charging mode
Test Specification:
AC 240V, 60Hz via adapter
Neutral Line
Comment:
Tem.:24.8℃ Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 17 of 59 Report No.:SZAWW180112002-01
4. Radiation Spurious Emission and Band Edge
4.1. Test Standard and Limit
Test Standard FCC Part15 C Section 15.209 and 15.205
Frequency
(MHz)
Field strength
(microvolt/meter)
Limit
(dBuV/m)
Remark
Measurement
distance (m)
0.009MHz~0.490MHz
2400/F(kHz)
300
0.490MHz-1.705MHz
24000/F(kHz)
30
1.705MHz-30MHz
30
30
30MHz~88MHz
100
40.0
Quasi-peak
88MHz~216MHz
150
43.5
Quasi-peak
216MHz~960MHz
200
46.0
Quasi-peak
960MHz~1000MHz
500
54.0
Quasi-peak
500
54.0
Average
74.0
Peak
Test Limit
Above 1000MHz
Remark:
(1)The lower limit shall apply at the transition frequency.
(2) 15.35(b), Unless otherwise specified, the limit on peak radio frequency emissions is 20dB above the maximum permitted average
emission limit applicable to the equipment under test. This peak limit applies to the total peak emission level radiated by the device.
4.2. Test Setup
Figure 1. Below 30MHz
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 18 of 59 Report No.:SZAWW180112002-01
Figure 2. 30MHz to 1GHz
Figure 3. Above 1 GHz
4.3. Test Procedure
For below 1GHz: The EUT is placed on a turntable, which is 0.8m above the ground plane.
For above 1GHz: The EUT is placed on a turntable, which is 1.5m above the ground plane.
The turn table can rotate 360 degrees to determine the position of the maximum emission level. The
EUT is set 3 meters away from the receiving antenna which is mounted on a antenna tower. The
antenna can be moved up and down from 1 to 4 meters to find out the maximum emission level.
Rotated the EUT through three orthogonal axes to determine the maximum emissions, both
horizontal and vertical polarization of the antenna are set on test. The EUT is tested in 9*6*6
Chamber. The device is evaluated in xyz orientation.
For the radiated emission test above 1GHz:
Place the measurement antenna away from each area of the EUT determined to be a source of
emissions at the specified measurement distance, while keeping the measurement antenna aimed at
the source of emissions at each frequency of significant emissions, with polarization oriented for
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 19 of 59 Report No.:SZAWW180112002-01
maximum response. The measurement antenna may have to be higher or lower than the EUT,
depending on the radiation pattern of the emission and staying aimed at the emission source for
receiving the maximum signal. The final measurement antenna elevation shall be that which
maximizes the emissions. The measurement antenna elevation for maximum emissions shall be
restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane.
For 9kHz to 150kHz, Set the spectrum analyzer as:
RBW = 200Hz, VBW =1kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.
For 150kHz to 30MHz, Set the spectrum analyzer as:
RBW = 9KHz, VBW =30kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.
For 30MHz to 1000MHz, Set the spectrum analyzer as:
RBW = 100kHz, VBW =300kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto
couple.
For above 1GHz,Set the spectrum analyzer as:
RBW =1MHz, VBW =1MHz, Detector= Peak, Trace mode= Max hold, Sweep- auto couple.
RBW =1MHz, VBW =10Hz, Detector= Average, Trace mode= Max hold, Sweep- auto couple.
4.4. Test Data
PASS
During the test, Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and found the X-axis
is the worst case.
The test results of 9kHz-30MHz was attenuated more than 20dB below the permissible limits, so
the results don't record in the report.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 20 of 59 Report No.:SZAWW180112002-01
Test Results (30~1000MHz)
Job No.:
SZAWW180112002-01
Temp.(℃)/Hum.(%RH)
24.3℃/55%RH
Standard:
FCC PART 15C
Power Source:
AC 120V, 60Hz
Test Mode:
Keeping
mode
Polarization:
Horizontal
TX+Charging
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 21 of 59 Report No.:SZAWW180112002-01
Test Results (30~1000MHz)
Job No.:
SZAWW180112002-01
Temp.(℃)/Hum.(%RH):
24.5℃/62%RH
Standard:
FCC PART 15C
Power Source:
AC 120V, 60Hz
Test Mode:
Keeping
mode
TX+Charging Polarization:
Vertical
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 22 of 59 Report No.:SZAWW180112002-01
Test Results (Above 1000MHz)
Test Mode: 802.11b Mode
Test channel: Lowest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4824.00
40.20
34.13
6.61
34.09
46.85
74.00
-27.15
7236.00
34.16
37.14
7.74
34.51
44.53
74.00
-29.47
9648.00
32.67
39.35
9.26
34.80
46.48
74.00
-27.52
12060.00
74.00
14472.00
74.00
16884.00
74.00
4824.00
38.89
34.13
6.61
34.09
45.54
74.00
-28.46
7236.00
33.92
37.14
7.74
34.51
44.29
74.00
-29.71
9648.00
32.26
39.35
9.26
34.80
46.07
74.00
-27.93
12060.00
74.00
14472.00
74.00
16884.00
74.00
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4824.00
29.30
34.13
6.61
34.09
35.95
54.00
-18.05
7236.00
23.03
37.14
7.74
34.51
33.40
54.00
-20.60
9648.00
23.02
39.35
9.26
34.80
36.83
54.00
-17.17
12060.00
54.00
14472.00
54.00
16884.00
54.00
4824.00
28.43
34.13
6.61
34.09
35.08
54.00
-18.92
7236.00
22.50
37.14
7.74
34.51
32.87
54.00
-21.13
9648.00
22.00
39.35
9.26
34.80
35.81
54.00
-18.19
12060.00
54.00
14472.00
54.00
16884.00
54.00
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 23 of 59 Report No.:SZAWW180112002-01
Test Results (Above 1000MHz)
Test Mode: 802.11b Mode
Test channel: Middle
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4874.00
39.28
34.35
6.67
34.09
46.21
74.00
-27.79
7311.00
34.24
37.21
7.77
34.53
44.69
74.00
-29.31
9748.00
33.70
39.45
9.33
34.80
47.68
74.00
-26.32
12185.00
74.00
14622.00
74.00
17059.00
74.00
4874.00
39.77
34.35
6.67
34.09
46.70
74.00
-27.30
7311.00
32.89
37.21
7.77
34.53
43.34
74.00
-30.66
9748.00
33.59
39.45
9.33
34.80
47.57
74.00
-26.43
12185.00
74.00
14622.00
74.00
17059.00
74.00
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4874.00
30.14
34.35
6.67
34.09
37.07
54.00
-16.93
7311.00
22.56
37.21
7.77
34.53
33.01
54.00
-20.99
9748.00
22.95
39.45
9.33
34.80
36.93
54.00
-17.07
12185.00
54.00
14622.00
54.00
17059.00
54.00
4874.00
29.88
34.35
6.67
34.09
36.81
54.00
-17.19
7311.00
21.98
37.21
7.77
34.53
32.43
54.00
-21.57
9748.00
23.31
39.45
9.33
34.80
37.29
54.00
-16.71
12185.00
54.00
14622.00
54.00
17059.00
54.00
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 24 of 59 Report No.:SZAWW180112002-01
Test Results (Above 1000MHz)
Test Mode:802.11b Mode
Test channel: Highest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4924.00
44.75
34.57
6.74
34.09
51.97
74.00
-22.03
7386.00
34.89
37.29
7.80
34.55
45.43
74.00
-28.57
9848.00
36.97
39.55
9.41
34.81
51.12
74.00
-22.88
12310.00
74.00
14772.00
74.00
17234.00
74.00
4924.00
44.08
34.57
6.74
34.09
51.30
74.00
-22.70
7386.00
33.80
37.29
7.80
34.55
44.34
74.00
-29.66
9848.00
33.15
39.55
9.41
34.81
47.30
74.00
-26.70
12310.00
74.00
14772.00
74.00
17234.00
74.00
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
4924.00
35.68
34.57
6.74
34.09
42.90
54.00
-11.10
7386.00
24.80
37.29
7.80
34.55
35.34
54.00
-18.66
9848.00
25.48
39.55
9.41
34.81
39.63
54.00
-14.37
12310.00
54.00
14772.00
54.00
17234.00
54.00
4924.00
34.45
34.57
6.74
34.09
41.67
54.00
-12.33
7386.00
23.19
37.29
7.80
34.55
33.73
54.00
-20.27
9848.00
22.41
39.55
9.41
34.81
36.56
54.00
-17.44
12310.00
54.00
14772.00
54.00
17234.00
54.00
Remark:
1. During the test, pre-scan the 802.11b,g mode, and found the 802.11b mode is worse case , the report only record this
mode.
2. Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
3. “*”, means this data is the too weak instrument of signal is unable to test.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 25 of 59 Report No.:SZAWW180112002-01
Radiated Band Edge:
Test Mode: 802.11b Mode
Test channel: Lowest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2390.00
52.26
29.15
3.41
34.01
50.81
74.00
-23.19
2400.00
61.47
29.16
3.43
34.01
60.05
74.00
-13.95
2390.00
53.98
29.15
3.41
34.01
52.53
74.00
-21.47
2400.00
63.43
29.16
3.43
34.01
62.01
74.00
-11.99
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2390.00
38.84
29.15
3.41
34.01
37.39
54.00
-16.61
2400.00
47.20
29.16
3.43
34.01
45.78
54.00
-8.22
2390.00
40.71
29.15
3.41
34.01
39.26
54.00
-14.74
2400.00
48.37
29.16
3.43
34.01
46.95
54.00
-7.05
Test Mode: 802.11b Mode
Test channel: Highest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2483.50
53.17
29.28
3.53
34.03
51.95
74.00
-22.05
2500.00
48.81
29.30
3.56
34.03
47.64
74.00
-26.36
2483.50
55.56
29.28
3.53
34.03
54.34
74.00
-19.66
2500.00
51.43
29.30
3.56
34.03
50.26
74.00
-23.74
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2483.50
39.30
29.28
3.53
34.03
38.08
54.00
-15.92
2500.00
35.29
29.30
3.56
34.03
34.12
54.00
-19.88
2483.50
41.30
29.28
3.53
34.03
40.08
54.00
-13.92
2500.00
37.19
29.30
3.56
34.03
36.02
54.00
-17.98
Remark:
1. Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 26 of 59 Report No.:SZAWW180112002-01
Radiated Band Edge:
Test Mode: 802.11g Mode
Test channel: Lowest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2390.00
51.14
27.53
5.47
33.92
50.22
74.00
-23.78
2400.00
59.98
27.55
5.49
29.93
63.09
74.00
-10.91
2390.00
52.79
27.53
5.47
33.92
51.87
74.00
-22.13
2400.00
61.64
27.55
5.49
29.93
64.75
74.00
-9.25
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2390.00
38.05
27.53
5.47
33.92
37.13
54.00
-16.87
2400.00
46.29
27.55
5.49
29.93
49.40
54.00
-4.60
2390.00
39.83
27.53
5.47
33.92
38.91
54.00
-15.09
2400.00
47.37
27.55
5.49
29.93
50.48
54.00
-3.52
Test Mode: 802.11g Mode
Test channel: Highest
Peak Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2483.50
51.58
29.28
3.53
34.03
50.36
74.00
-23.64
2500.00
47.57
29.30
3.56
34.03
46.40
74.00
-27.60
2483.50
53.73
29.28
3.53
34.03
52.51
74.00
-21.49
2500.00
49.98
29.30
3.56
34.03
48.81
74.00
-25.19
Average Value
Frequency
(MHz)
Read Level
(dBuV)
Antenna
Factor
(dB/m)
Cable Loss
(dB)
Preamp
Factor
(dB)
Level
(dBuV/m)
Limit
(dBuV/m)
Over Limit
(dB)
Pol.
2483.50
38.34
29.28
3.53
34.03
37.12
54.00
-16.88
2500.00
34.54
29.30
3.56
34.03
33.37
54.00
-20.63
2483.50
40.24
29.28
3.53
34.03
39.02
54.00
-14.98
2500.00
36.40
29.30
3.56
34.03
35.23
54.00
-18.77
Remark:
1. Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 27 of 59 Report No.:SZAWW180112002-01
5. Maximum Peak Output Power Test
5.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.247 (b)(3)
Test Limit
30dBm
5.2. Test Setup
5.3. Test Procedure
1. The Transmitter output (antenna port) was connected to the power meter.
2. Turn on the EUT and power meter and then record the power value.
3. Repeat above procedures on all channels needed to be tested.
Note: The cable loss and attenuator loss were offset into measure device as amplitude offset.
5.4. Test Data
Test Item
Test Voltage
Test Result
Max. peak output power
AC 120V/60Hz
PASS
Test Mode
: CH Low ~ CH High
Temperature : 24℃
Humidity
: 55%RH
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 28 of 59 Report No.:SZAWW180112002-01
Test Channel
Frequency
(MHz)
Maximum Peak Conducted
Output Power(PK)
(dBm)
Limit
dBm
Results
TX 802.11b Mode
CH01
2412
11.13
30
PASS
CH06
2437
10.35
30
PASS
CH11
2462
10.14
30
PASS
TX 802.11g Mode
CH01
2412
9.98
30
PASS
CH06
2437
9.48
30
PASS
CH11
2462
9.27
30
PASS
Note: For power test the duty cycle is 100% in continuous transmitting mode.
Please see the plot of next page
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 29 of 59 Report No.:SZAWW180112002-01
Duty Cycle
802.11b mode
802.11g mode
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 30 of 59 Report No.:SZAWW180112002-01
6. 6DB Occupy Bandwidth Test
6.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.247 (a)(2)
Test Limit
>500kHz
6.2. Test Setup
6.3. Test Procedure
1. Place the EUT on the table and set it in the transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to
the spectrum analyzer.
3. Set the spectrum analyzer as:
RBW= 100kHz, VBW≥3*RBW =300kHz
Detector= Peak
Trace mode= Max hold.
Sweep- auto couple.
4. Mark the peak frequency and –6dB (upper and lower) frequency.
5. Repeat until all the rest channels are investigated.
6.4. Test Data
Test Item
Test Voltage
Test Result
6dB Bandwidth
AC 120V/60Hz
PASS
Test Mode
: CH Low ~ CH High
Temperature : 24℃
Humidity
: 55%RH
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 31 of 59 Report No.:SZAWW180112002-01
Mode
802.11b
802.11g
Channel
Frequency
(MHz)
Bandwidth
(MHz)
Limit
(kHz)
Low
2412
9.576
Middle
2437
9.132
High
2462
9.598
PASS
Low
2412
15.38
PASS
Middle
2437
15.16
High
2462
15.48
Results
PASS
>500
>500
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
PASS
PASS
PASS
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 32 of 59 Report No.:SZAWW180112002-01
802.11b mode : Lowest
802.11b mode : Middle
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 33 of 59 Report No.:SZAWW180112002-01
802.11b mode : Highest
802.11g mode : Lowest
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 34 of 59 Report No.:SZAWW180112002-01
802.11g mode : Middle
802.11g mode : Highest
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 35 of 59 Report No.:SZAWW180112002-01
7. Power Spectral Density Test
7.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.247 (e)
Test Limit
8dBm/3KHz
7.2. Test Setup
7.3. Test Procedure
1. Place the EUT on the table and set it in transmitting mode. Remove the antenna from the EUT
and then connect a low loss RF cable from the antenna port to the spectrum analyzer.
2. Set the spectrum analyzer as RBW = 3kHz, VBW = 10kHz, Span = 1.5xDTS BW
3. Record the max. reading.
4. Repeat the above procedure until the measurements for all frequencies are completed.
7.4. Test Data
Test Item
Test Voltage
Test Result
Mode
802.11b
802.11g
: Power Spectral Density
: AC 120V/60Hz
: PASS
Channel
Low
Middle
High
Low
Middle
High
Frequency
(MHz)
2412
2437
2462
2412
2437
2462
Test Mode
: CH Low ~ CH High
Temperature : 24℃
Humidity
: 55%RH
PPSD
(dBm/3KHz)
-8.703
-9.019
-9.829
-13.761
-12.330
-12.170
Limit
(dBm/3KHz)
8.00
8.00
8.00
8.00
8.00
8.00
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Results
PASS
PASS
PASS
PASS
PASS
PASS
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 36 of 59 Report No.:SZAWW180112002-01
802.11b mode : Lowest
802.11b mode : Middle
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 37 of 59 Report No.:SZAWW180112002-01
802.11b mode : Highest
802.11g mode : Lowest
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 38 of 59 Report No.:SZAWW180112002-01
802.11g mode : Middle
802.11g mode : Highest
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 39 of 59 Report No.:SZAWW180112002-01
8. 100kHz Bandwidth of Frequency Band Edge Requirement
8.1. Test Standard and Limit
Test Standard
FCC Part15 C Section 15.247 (d)
Test Limit
in any 100 kHz bandwidth outside the frequency bands in which the
spread spectrum intentional radiator in operating, the radio frequency
power that is produced by the intentional radiator shall be at least 20dB
below that in the 100kHz bandwidth within the band that contains the
highest level of the desired power, In addition, radiated emissions which
fall in the restricted bands, as defined in §15.205(a), must also comply
with the radiated emission limits specified in15.209(a).
8.2. Test Setup
8.3. Test Procedure
Using the following spectrum analyzer setting:
1. Set the RBW = 100KHz.
2. Set the VBW = 300KHz.
3. Sweep time = auto couple.
4. Detector function = peak.
5. Trace mode = max hold.
6. Allow trace to fully stabilize.
8.4. Test Data
Test Item
Test Voltage
Test Result
Band edge
AC 120V/60Hz
PASS
Test Mode
: CH Low ~ CH High
Temperature : 24℃
Humidity
: 55%RH
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 40 of 59 Report No.:SZAWW180112002-01
Mode
Frequency Band
(MHz)
Delta Peak to Band
Emission
(dBc)
Limit
(dBc)
Results
2412
43.753
>20
PASS
2462
60.703
>20
PASS
2412
31.578
>20
PASS
2462
42.657
>20
PASS
802.11b
802.11g
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 41 of 59 Report No.:SZAWW180112002-01
802.11b mode : Lowest
802.11b mode : Highest
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 42 of 59 Report No.:SZAWW180112002-01
802.11g mode : Lowest
802.11g mode : Highest
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 43 of 59 Report No.:SZAWW180112002-01
Conducted Emission Method
802.11b mode : Lowest
802.11b mode : Middle
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 44 of 59 Report No.:SZAWW180112002-01
802.11b mode : Highest
802.11g mode : Lowest
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 45 of 59 Report No.:SZAWW180112002-01
802.11g mode : Middle
802.11g mode : Highest
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 46 of 59 Report No.:SZAWW180112002-01
9. Antenna Requirement
9.1. Test Standard and Requirement
Test Standard
FCC Part15 Section 15.203 /247(c)
Requirement
1) 15.203 requirement:
An intentional radiator shall be designed to ensure that no antenna other than
that furnished by the responsible party shall be used with the device.
The use
of a permanently attached antenna or of an antenna that uses a unique coupling
to the intentional radiator, the manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the use of a standard antenna
jack or electrical connector is prohibited.
2) 15.247(c) (1)(i) requirement:
Systems operating in the 2400-2483.5 MHz band that is used exclusively for
fixed. Point-to-point operations may employ transmitting antennas with
directional gain greater than 6dBi provided the maximum conducted output
power of the intentional radiator is reduced by 1 dB for every 3 dB that the
directional gain of the antenna exceeds 6 dBi.
9.2. Antenna Connected Construction
The WIFI antenna is a PIFA Antenna which permanently attached, and the best case gain of the
antenna is 0.7 dBi It complies with the standard requirement.
WIFI Antenna
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 47 of 59 Report No.:SZAWW180112002-01
APPENDIX I -- TEST SETUP PHOTOGRAPH
Photo of Conducted Emission Test
Photo of Radiation Emission Test
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 48 of 59 Report No.:SZAWW180112002-01
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 49 of 59 Report No.:SZAWW180112002-01
APPENDIX II -- EXTERNAL PHOTOGRAPH
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 50 of 59 Report No.:SZAWW180112002-01
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 51 of 59 Report No.:SZAWW180112002-01
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 52 of 59 Report No.:SZAWW180112002-01
APPENDIX III -- INTERNAL PHOTOGRAPH
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 53 of 59 Report No.:SZAWW180112002-01
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 54 of 59 Report No.:SZAWW180112002-01
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 55 of 59 Report No.:SZAWW180112002-01
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 56 of 59 Report No.:SZAWW180112002-01
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 57 of 59 Report No.:SZAWW180112002-01
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 58 of 59 Report No.:SZAWW180112002-01
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
FCC ID: 2APAA-R1LTC Page 59 of 59 Report No.:SZAWW180112002-01
End of Report
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066365
Fax:(86)755-26014772
www.anbotek.com
Download: R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Mirror Download [FCC.gov]R1LTC Router miner Test Report  ShenZhen Century Cloud Core Technologies Limited
Document ID3817004
Application IDJ4TCPNKdaSJALW8TUClR5Q==
Document DescriptionRF Test Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize338.62kB (4232719 bits)
Date Submitted2018-04-16 00:00:00
Date Available2018-04-16 00:00:00
Creation Date2018-03-21 14:24:49
Producing SoftwareAcrobat Distiller 9.3.3 (Windows)
Document Lastmod2018-03-21 14:26:32
Document TitleTest Report
Document CreatorPScript5.dll Version 5.2.2
Document Author: Administrator

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Administrator
Create Date                     : 2018:03:21 14:24:49+08:00
Modify Date                     : 2018:03:21 14:26:32+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2018:03:21 14:26:32+08:00
Producer                        : Acrobat Distiller 9.3.3 (Windows)
Format                          : application/pdf
Title                           : <5C5C3139322E3136382E322E3130325CCAB5D1E9CAD25C215246CAC2D2B5B2BF5C323031382050726F6A6563745C31D4C2B7DD5C535A41575731383031313230303220CAC0BCCDD4C6D0BE205231CFB5C1D02052315F4C544320CEE2B0EEBBD42DC3C9C1D6D3A2204643432D494428D0C5BFC6295CD6A4C
Creator                         : Administrator
Document ID                     : uuid:6c542b94-4f7d-49e2-9e4f-b8737b8f985c
Instance ID                     : uuid:ea9460c5-94c0-4e61-8860-2ee50a9e4f79
Page Count                      : 59