FCC ID 2APJ4-SLT779
MiFi
by MeiG Smart Technology Co., Ltd
Grantee Code: 2APJ4 Product Code: SLT779
Latest application date: 2022-08-30
FCC ID Device Details
| FCC ID | 2APJ4-SLT779 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2APJ4 |
| Product Code | SLT779 |
| Applicant Business | MeiG Smart Technology Co., Ltd 🇨🇳 |
| Related Domains | |
| Equipment Class | MiFi |
| Test Firm | Shenzhen NTEK Testing Technology Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2022-08-30 |
| 5745-5825 MHz | Original Equipment | 2022-08-30 |
| 665.5-695.5 MHz | Original Equipment | 2022-08-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| U Manual | Users Manual | 2023-02-26 | PDF 467.2 KB |
| User Manual | Users Manual | 2023-02-26 | PDF 467.2 KB |
| Internal Photos | Internal Photos | 2023-02-26 | PDF 2.3 MB |
| Internal photo | Internal Photos | 2023-02-26 | PDF 2.3 MB |
| External Photos | External Photos | 2023-02-26 | PDF 1 MB |
| External photo | External Photos | 2023-02-26 | PDF 1 MB |
| Label and Label Location | ID Label/Location Info | 2022-08-30 | PDF 82.2 KB |
| Label and Label location | ID Label/Location Info | 2022-08-30 | PDF 82.2 KB |
| T Setup photo | Test Setup Photos | 2023-02-26 | PDF 231.2 KB |
| Test Setup Photos SAR | Test Setup Photos | 2023-02-26 | PDF 1,019.5 KB |
| Test Setup photos | Test Setup Photos | 2023-02-26 | PDF 488.7 KB |
| Test Setup photos | Test Setup Photos | 2023-02-26 | PDF 321.9 KB |
| Test photos | Test Setup Photos | 2023-02-26 | PDF 321.9 KB |
| Test Report | Test Report | 2022-08-30 | PDF 5.8 MB |
| Test Report | Test Report | 2022-08-30 | PDF 5.7 MB |
| Test Report | Test Report | 2022-08-30 | PDF 5.8 MB |
| Test ReportSAR | RF Exposure Info | 2022-08-30 | PDF 4.6 MB |
| SDoCAttestationLetter | Cover Letter(s) | 2022-08-30 | PDF 81.5 KB |
| Antenna Report | Cover Letter(s) | 2022-08-30 | PDF 350.4 KB |
| Antenna kitting | Cover Letter(s) | 2022-08-30 | PDF 350.4 KB |
| AntennaSpecification | Cover Letter(s) | 2022-08-30 | PDF 350.4 KB |
| FCC Short_Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 2022-08-30 | PDF 126.8 KB |
| FCC Software Configuration Control Declaration Rev1.1 | Cover Letter(s) | 2022-08-30 | PDF 75.1 KB |
| Letter of Authorization Rev 2.0 | Cover Letter(s) | 2022-08-30 | PDF 108.7 KB |
| Long | Cover Letter(s) | 2022-08-30 | PDF 126.8 KB |
| Sample_LetterofAuthorizationRev2.0 | Cover Letter(s) | 2022-08-30 | PDF 108.7 KB |
| Block Metadata only | Block Diagram | PDF 172.6 KB | |
| Block Diagram Metadata only | Block Diagram | PDF 172.6 KB | |
| SCH Metadata only | Schematics | PDF 317.4 KB | |
| OP Metadata only | Operational Description | PDF 167.8 KB | |
| FCC Software Security Requirements for UNII devices Rev 2.1 Metadata only | SDR Software/Security Inf | PDF 135.6 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 190.4 KB | |
| Tune Up Procedure Metadata only | Parts List/Tune Up Info | PDF 339.2 KB |
Application Information
| Application ID | vxuK1+ZiQrvEao2Wr1KEXw== |
|---|---|
| Final Action Date | 2022-08-30 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0027430412 |
| Model | SLT779 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | MiFi |
| Responsible Party | Xinwei Lou, HW test Leader, louxinwei@meigsmart.com |
| Technical Contact | MeiG Smart Technology Co., Ltd, louxinwei@meigsmart.com |
| Test Firm | Alex Li, Shenzhen NTEK Testing Technology Co., Ltd., certification@ntek.org.cn |
| TCB Email | certification@micomlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 02/26/2023 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for product specific (wireless router) and simultaneous transmission use conditions is 0.19W/kg and 1.29W/kg respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| vxuK1+ZiQrvEao2Wr1KEXw== | 2022-08-30 | Original Equipment |
| mUuM/sVNFVN2rhCr/Yw58w== | 2022-08-30 | Original Equipment |
| 2yxXDlxuR/H5Kd0WeM/7hg== | 2022-08-30 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 665.5-695.5 MHz | 0.11041 | 0.00443ppm | 17M9G7D | 27 | |
| 665.5-695.5 MHz | 0.07907 | 0.00561ppm | 17M9W7D | 27 | |
| 699.7-715.3 MHz | 0.09016 | 0.01363ppm | 8M96G7D | 27 | |
| 699.7-715.3 MHz | 0.07674 | 0.01311ppm | 8M97W7D | 27 | |
| 779.5-784.5 MHz | 0.10839 | 0.01886ppm | 8M95G7D | 27 | |
| 779.5-784.5 MHz | 0.08511 | 0.0184ppm | 8M93W7D | 27 | |
| 814.7-823.3 MHz | 0.11912 | 0.01183ppm | 8M95G7D | 9 | |
| 814.7-823.3 MHz | 0.09397 | 0.01232ppm | 8M95W7D | 9 | |
| 824.7-848.3 MHz | 0.10889 | 0.0115ppm | 13M4G7D | 22H | |
| 824.7-848.3 MHz | 0.0859 | 0.01253ppm | 13M4W7D | 22H | |
| 824.7-848.3 MHz | 0.14723 | 0.00821ppm | 8M96G7D | 22H | |
| 824.7-848.3 MHz | 0.12134 | 0.00793ppm | 8M95W7D | 22H | |
| 1710.7-1779.3 MHz | 0.14894 | 0.0045ppm | 17M9G7D | 27 | |
| 1710.7-1779.3 MHz | 0.13868 | 0.00534ppm | 17M9W7D | 27 | |
| 1710.7-1754.3 MHz | 0.15631 | 0.00538ppm | 17M9G7D | 27 | |
| 1710.7-1754.3 MHz | 0.12134 | 0.00594ppm | 17M9W7D | 27 | |
| 1850.7-1914.3 MHz | 0.15241 | 0.00543ppm | 17M9G7D | 24E | |
| 1850.7-1914.3 MHz | 0.12882 | 0.00541ppm | 18M0W7D | 24E | |
| 1850.7-1909.3 MHz | 0.13243 | 0.0051ppm | 18M0W7D | 24E | |
| 2412-2462 MHz | 0.0690200 | 15C | CC | ||
| 2498.5-2687.5 MHz | 0.22646 | 0.00395ppm | 17M9G7D | 27 | |
| 2498.5-2687.5 MHz | 0.16255 | 0.00266ppm | 17M9W7D | 27 | |
| 5180-5240 MHz | 0.06166 | 15E | CC | ||
| 5745-5825 MHz | 0.06668 | 15E | CC |
Grants
TCB Grant - Application vxuK1+ZiQrvEao2Wr1KEXw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 08/30/2022 Application Dated: 08/30/2022 |
| MeiG Smart Technology Co., Ltd |
| 2nd Floor, Office Building,No.5 Lingxia Road, |
| Fenghuang,Fuyong Street, |
| Bao 'an District,shenzhen, China |
| Attention: Xinwei Lou , HW test Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2APJ4-SLT779 |
| Name of Grantee: | MeiG Smart Technology Co., Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | MiFi |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.06902 |
| Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for product specific (wireless router) and simultaneous transmission use conditions is 0.19W/kg and 1.29W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application vxuK1+ZiQrvEao2Wr1KEXw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
MeiG Smart Technology Co., Ltd 2nd Floor, Office Building,No.5 Lingxia Road, Fenghuang,Fuyong Street, Bao 'an District,shenzhen, China |
Date of Grant: 08/30/2022 Application Dated: 08/30/2022 |
| Attention: Xinwei Lou , HW test Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2APJ4-SLT779 |
| Name of Grantee: | MeiG Smart Technology Co., Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | MiFi |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.06902 |
| Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for product specific (wireless router) and simultaneous transmission use conditions is 0.19W/kg and 1.29W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 08/30/2022 Application Dated: 08/30/2022 |
| MeiG Smart Technology Co., Ltd |
| 2nd Floor, Office Building,No.5 Lingxia Road, |
| Fenghuang,Fuyong Street, |
| Bao 'an District,shenzhen, China |
| Attention: Xinwei Lou , HW test Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2APJ4-SLT779 |
| Name of Grantee: | MeiG Smart Technology Co., Ltd |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | MiFi |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.06166 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.06668 |
| Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for product specific (wireless router) and simultaneous transmission use conditions is 0.48W/kg and 1.49W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application mUuM/sVNFVN2rhCr/Yw58w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
MeiG Smart Technology Co., Ltd 2nd Floor, Office Building,No.5 Lingxia Road, Fenghuang,Fuyong Street, Bao 'an District,shenzhen, China |
Date of Grant: 08/30/2022 Application Dated: 08/30/2022 |
| Attention: Xinwei Lou , HW test Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2APJ4-SLT779 |
| Name of Grantee: | MeiG Smart Technology Co., Ltd |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | MiFi |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.06166 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.06668 |
| Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for product specific (wireless router) and simultaneous transmission use conditions is 0.48W/kg and 1.49W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 08/30/2022 Application Dated: 08/30/2022 |
| MeiG Smart Technology Co., Ltd |
| 2nd Floor, Office Building,No.5 Lingxia Road, |
| Fenghuang,Fuyong Street, |
| Bao 'an District,shenzhen, China |
| Attention: Xinwei Lou , HW test Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2APJ4-SLT779 |
| Name of Grantee: | MeiG Smart Technology Co., Ltd |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | MiFi |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 826.4 - 846.6 | 0.2133 | 0.029376 PM | 4M14F9W | |
| 24E | 1850.7 - 1909.3 | 0.15959 | 0.00767 PM | 17M9G7D | |
| 24E | 1850.7 - 1909.3 | 0.13243 | 0.0051 PM | 18M0W7D | |
| 27 | 1710.7 - 1754.3 | 0.15631 | 0.00538 PM | 17M9G7D | |
| 27 | 1710.7 - 1754.3 | 0.12134 | 0.00594 PM | 17M9W7D | |
| 22H | 824.7 - 848.3 | 0.14723 | 0.00821 PM | 8M96G7D | |
| 22H | 824.7 - 848.3 | 0.12134 | 0.00793 PM | 8M95W7D | |
| 27 | 699.7 - 715.3 | 0.09016 | 0.01363 PM | 8M96G7D | |
| 27 | 699.7 - 715.3 | 0.07674 | 0.01311 PM | 8M97W7D | |
| 27 | 779.5 - 784.5 | 0.10839 | 0.01886 PM | 8M95G7D | |
| 27 | 779.5 - 784.5 | 0.08511 | 0.0184 PM | 8M93W7D | |
| 24E | 1850.7 - 1914.3 | 0.15241 | 0.00543 PM | 17M9G7D | |
| 24E | 1850.7 - 1914.3 | 0.12882 | 0.00541 PM | 18M0W7D | |
| 90 | 814.7 - 823.3 | 0.11912 | 0.01183 PM | 8M95G7D | |
| 90 | 814.7 - 823.3 | 0.09397 | 0.01232 PM | 8M95W7D | |
| 22H | 824.7 - 848.3 | 0.10889 | 0.0115 PM | 13M4G7D | |
| 22H | 824.7 - 848.3 | 0.0859 | 0.01253 PM | 13M4W7D | |
| 27 | 2498.5 - 2687.5 | 0.22646 | 0.00395 PM | 17M9G7D | |
| 27 | 2498.5 - 2687.5 | 0.16255 | 0.00266 PM | 17M9W7D | |
| 27 | 1710.7 - 1779.3 | 0.14894 | 0.0045 PM | 17M9G7D | |
| 27 | 1710.7 - 1779.3 | 0.13868 | 0.00534 PM | 17M9W7D | |
| 27 | 665.5 - 695.5 | 0.11041 | 0.00443 PM | 17M9G7D | |
| 27 | 665.5 - 695.5 | 0.07907 | 0.00561 PM | 17M9W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for product specific (wireless router) and simultaneous transmission use conditions is 1.13W/kg and 1.49W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. |
EAS Grant - Application 2yxXDlxuR/H5Kd0WeM/7hg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
MeiG Smart Technology Co., Ltd 2nd Floor, Office Building,No.5 Lingxia Road, Fenghuang,Fuyong Street, Bao 'an District,shenzhen, China |
Date of Grant: 08/30/2022 Application Dated: 08/30/2022 |
| Attention: Xinwei Lou , HW test Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2APJ4-SLT779 |
| Name of Grantee: | MeiG Smart Technology Co., Ltd |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | MiFi |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 826.4 - 846.6 | 0.2133 | 0.029376 PM | 4M14F9W | |
| 24E | 1850.7 - 1909.3 | 0.15959 | 0.00767 PM | 17M9G7D | |
| 24E | 1850.7 - 1909.3 | 0.13243 | 0.0051 PM | 18M0W7D | |
| 27 | 1710.7 - 1754.3 | 0.15631 | 0.00538 PM | 17M9G7D | |
| 27 | 1710.7 - 1754.3 | 0.12134 | 0.00594 PM | 17M9W7D | |
| 22H | 824.7 - 848.3 | 0.14723 | 0.00821 PM | 8M96G7D | |
| 22H | 824.7 - 848.3 | 0.12134 | 0.00793 PM | 8M95W7D | |
| 27 | 699.7 - 715.3 | 0.09016 | 0.01363 PM | 8M96G7D | |
| 27 | 699.7 - 715.3 | 0.07674 | 0.01311 PM | 8M97W7D | |
| 27 | 779.5 - 784.5 | 0.10839 | 0.01886 PM | 8M95G7D | |
| 27 | 779.5 - 784.5 | 0.08511 | 0.0184 PM | 8M93W7D | |
| 24E | 1850.7 - 1914.3 | 0.15241 | 0.00543 PM | 17M9G7D | |
| 24E | 1850.7 - 1914.3 | 0.12882 | 0.00541 PM | 18M0W7D | |
| 90 | 814.7 - 823.3 | 0.11912 | 0.01183 PM | 8M95G7D | |
| 90 | 814.7 - 823.3 | 0.09397 | 0.01232 PM | 8M95W7D | |
| 22H | 824.7 - 848.3 | 0.10889 | 0.0115 PM | 13M4G7D | |
| 22H | 824.7 - 848.3 | 0.0859 | 0.01253 PM | 13M4W7D | |
| 27 | 2498.5 - 2687.5 | 0.22646 | 0.00395 PM | 17M9G7D | |
| 27 | 2498.5 - 2687.5 | 0.16255 | 0.00266 PM | 17M9W7D | |
| 27 | 1710.7 - 1779.3 | 0.14894 | 0.0045 PM | 17M9G7D | |
| 27 | 1710.7 - 1779.3 | 0.13868 | 0.00534 PM | 17M9W7D | |
| 27 | 665.5 - 695.5 | 0.11041 | 0.00443 PM | 17M9G7D | |
| 27 | 665.5 - 695.5 | 0.07907 | 0.00561 PM | 17M9W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for product specific (wireless router) and simultaneous transmission use conditions is 1.13W/kg and 1.49W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. |
| Mail To: |