Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2023-03-17 |
| 2412-2462 MHz | Original Equipment | 2023-03-17 |
| 824.2-848.8 MHz | Original Equipment | 2023-03-17 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2023-03-17 | PDF 2.3 MB |
| Internal Photos | Internal Photos | 2023-03-17 | PDF 1.3 MB |
| External Photos | External Photos | 2023-03-17 | PDF 676.9 KB |
| Label & Label Location | ID Label/Location Info | 2023-03-17 | PDF 621 KB |
| Test Setup Photos | Test Setup Photos | 2023-03-17 | PDF 382.4 KB |
| Test Setup Photos | Test Setup Photos | 2023-03-17 | PDF 238.8 KB |
| Antenna Specification | Test Report | 2023-03-17 | PDF 5.7 MB |
| Test Report | Test Report | 2023-03-17 | PDF 2 MB |
| Test Report | Test Report | 2023-03-17 | PDF 4.9 MB |
| Test Report | Test Report | 2023-03-17 | PDF 5.4 MB |
| Test Report Appendix A | Test Report | 2023-03-17 | PDF 1 MB |
| Test Report Appendix B | Test Report | 2023-03-17 | PDF 996.7 KB |
| Test Report Appendix C | Test Report | 2023-03-17 | PDF 734.3 KB |
| 2.911 (d)(5)(i) Attestation Statement | Attestation Statements | 2023-03-17 | PDF 287.4 KB |
| 2.911 (d)(5)(ii) Attestation Statement | Attestation Statements | 2023-03-17 | PDF 301.2 KB |
| Attestation Letter | Attestation Statements | 2023-03-17 | PDF 215.6 KB |
| US Agent Attestation Letter | Attestation Statements | 2023-03-17 | PDF 11.3 KB |
| FCC Agent Authorization Letter | Cover Letter(s) | 2023-03-17 | PDF 11.8 KB |
| FCC Long-term Confidential Request | Cover Letter(s) | 2023-03-17 | PDF 113.6 KB |
| RF Exposure | RF Exposure Info | 2023-03-17 | PDF 195 KB |
| SAR EUT Test Position Photos | RF Exposure Info | 2023-03-17 | PDF 1.6 MB |
| SAR Probe & Dipole Calibration Certificates | RF Exposure Info | 2023-03-17 | PDF 5.5 MB |
| SAR Report | RF Exposure Info | 2023-03-17 | PDF 1.7 MB |
| SAR Scan Plots | RF Exposure Info | 2023-03-17 | PDF 5.5 MB |
| Block Diagram Metadata only | Block Diagram | PDF 126.5 KB | |
| Schematics Metadata only | Schematics | PDF 3.6 MB | |
| Circuit Description Metadata only | Operational Description | PDF 294.7 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 480.7 KB | |
| Tune up Procedure Metadata only | Parts List/Tune Up Info | PDF 377.2 KB |
Application Information
| Application ID | hQptIDctuGwQAGra0fJJPA== |
|---|---|
| Final Action Date | 2023-03-17 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0027561588 |
| Model | K51 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | 4G Smart Phone |
| Responsible Party | RENATO TAVARES, RENATO@KRIP.COM |
| Test Firm | Lisa Zhang, Shenzhen Accurate Technology Co., Ltd., qa@atc-lab.com |
| TCB Email | bacl.regulatory@baclcorp.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission exposure conditions are 0.03 W/kg, 0.02 W/kg and 0.74 W/kg, respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| hQptIDctuGwQAGra0fJJPA== | 2023-03-17 | Original Equipment |
| Zb64LKl/429PGoJhnrKYsw== | 2023-03-17 | Original Equipment |
| 6f1+MFmMAZ35vpSP6iyJBg== | 2023-03-17 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 824.2-848.8 MHz | 0.211 | 2.5ppm | 251KG7W | 22H |
| 826.4-846.6 MHz | 0.129 | 2.5ppm | 4M16F9W | 22H |
| 1711.5-1753.5 MHz | 0.169 | 2.5ppm | 2M70G7D | 27 |
| 1711.5-1753.5 MHz | 0.158 | 2.5ppm | 2M71D7W | 27 |
| 1720-1745 MHz | 0.18 | 2.5ppm | 18M1G7D | 27 |
| 1720-1745 MHz | 0.154 | 2.5ppm | 18M1D7W | 27 |
| 1850.2-1909.8 MHz | 0.923 | 2.5ppm | 246KGXW | 24E |
| 1850.2-1909.8 MHz | 0.419 | 2.5ppm | 246KG7W | 24E |
| 1852.4-1907.6 MHz | 0.206 | 2.5ppm | 4M17F9W | 24E |
| 1852.5-1907.5 MHz | 0.18 | 2.5ppm | 4M54G7D | 24E |
| 1852.5-1907.5 MHz | 0.139 | 2.5ppm | 4M54D7W | 24E |
| 1860-1900 MHz | 0.161 | 2.5ppm | 18M1D7W | 24E |
| 1860-1900 MHz | 0.178 | 2.5ppm | 18M1G7D | 24E |
| 2402-2480 MHz | 0.0020000 | 15C | ||
| 2402-2480 MHz | 0.001 | 15C | ||
| 2412-2462 MHz | 0.109 | 15C | ||
| 2502.5-2567.5 MHz | 0.196 | 2.5ppm | 4M56G7D | 27 |
| 2502.5-2567.5 MHz | 0.161 | 2.5ppm | 4M56D7W | 27 |
| 2510-2560 MHz | 0.177 | 2.5ppm | 18M0G7D | 27 |
| 2510-2560 MHz | 0.153 | 2.5ppm | 18M1D7W | 27 |
Grants
TCB Grant - Application Zb64LKl/429PGoJhnrKYsw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratories Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 03/17/2023 Application Dated: 03/17/2023 |
| KRIPTO MOBILE CORPORATION |
| 7640 NW 25TH ST |
| STE 101 |
| MIAMI, FL 33122 |
| Attention: RENATO TAVARES |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2APX7K51 |
| Name of Grantee: | KRIPTO MOBILE CORPORATION |
| Equipment Class: | Digital Transmission System |
| Notes: | 4G Smart Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.109 | |||
| 15C | 2402.0 - 2480.0 | 0.001 |
| Output power listed is peak conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission exposure conditions are 0.47 W/kg, 0.22 W/kg and 0.94 W/kg, respectively. |
EAS Grant - Application Zb64LKl/429PGoJhnrKYsw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
KRIPTO MOBILE CORPORATION 7640 NW 25TH ST STE 101 MIAMI, FL 33122 United States |
Date of Grant: 03/17/2023 Application Dated: 03/17/2023 |
| Attention: RENATO TAVARES |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2APX7K51 |
| Name of Grantee: | KRIPTO MOBILE CORPORATION |
| Equipment Class: | Digital Transmission System |
| Notes: | 4G Smart Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.109 | |||
| 15C | 2402.0 - 2480.0 | 0.001 |
| Output power listed is peak conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission exposure conditions are 0.47 W/kg, 0.22 W/kg and 0.94 W/kg, respectively. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratories Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 03/17/2023 Application Dated: 03/17/2023 |
| KRIPTO MOBILE CORPORATION |
| 7640 NW 25TH ST |
| STE 101 |
| MIAMI, FL 33122 |
| Attention: RENATO TAVARES |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2APX7K51 |
| Name of Grantee: | KRIPTO MOBILE CORPORATION |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | 4G Smart Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.002 |
| Output power listed is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission exposure conditions are 0.03 W/kg, 0.02 W/kg and 0.74 W/kg, respectively. |
EAS Grant - Application hQptIDctuGwQAGra0fJJPA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
KRIPTO MOBILE CORPORATION 7640 NW 25TH ST STE 101 MIAMI, FL 33122 United States |
Date of Grant: 03/17/2023 Application Dated: 03/17/2023 |
| Attention: RENATO TAVARES |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2APX7K51 |
| Name of Grantee: | KRIPTO MOBILE CORPORATION |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | 4G Smart Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.002 |
| Output power listed is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission exposure conditions are 0.03 W/kg, 0.02 W/kg and 0.74 W/kg, respectively. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratories Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 03/17/2023 Application Dated: 03/17/2023 |
| KRIPTO MOBILE CORPORATION |
| 7640 NW 25TH ST |
| STE 101 |
| MIAMI, FL 33122 |
| Attention: RENATO TAVARES |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2APX7K51 |
| Name of Grantee: | KRIPTO MOBILE CORPORATION |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | 4G Smart Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 1.211 | 2.5 PM | 248KGXW | |
| 22H | 824.2 - 848.8 | 0.211 | 2.5 PM | 251KG7W | |
| 22H | 826.4 - 846.6 | 0.129 | 2.5 PM | 4M16F9W | |
| 24E | 1850.2 - 1909.8 | 0.923 | 2.5 PM | 246KGXW | |
| 24E | 1850.2 - 1909.8 | 0.419 | 2.5 PM | 246KG7W | |
| 24E | 1852.4 - 1907.6 | 0.206 | 2.5 PM | 4M17F9W | |
| 24E | 1852.5 - 1907.5 | 0.18 | 2.5 PM | 4M54G7D | |
| 24E | 1852.5 - 1907.5 | 0.139 | 2.5 PM | 4M54D7W | |
| 24E | 1860.0 - 1900.0 | 0.178 | 2.5 PM | 18M1G7D | |
| 24E | 1860.0 - 1900.0 | 0.161 | 2.5 PM | 18M1D7W | |
| 27 | 1711.5 - 1753.5 | 0.169 | 2.5 PM | 2M70G7D | |
| 27 | 1711.5 - 1753.5 | 0.158 | 2.5 PM | 2M71D7W | |
| 27 | 1720.0 - 1745.0 | 0.18 | 2.5 PM | 18M1G7D | |
| 27 | 1720.0 - 1745.0 | 0.154 | 2.5 PM | 18M1D7W | |
| 27 | 2502.5 - 2567.5 | 0.196 | 2.5 PM | 4M56G7D | |
| 27 | 2502.5 - 2567.5 | 0.161 | 2.5 PM | 4M56D7W | |
| 27 | 2510.0 - 2560.0 | 0.177 | 2.5 PM | 18M0G7D | |
| 27 | 2510.0 - 2560.0 | 0.153 | 2.5 PM | 18M1D7W |
| Output power listed is ERP for operation below 1 GHz and EIRP for operation above 1 GHz. LTE supports 1.4/3/5/10/15/20 MHz BW modes in Band 2/4, 5/10/15/20 MHz BW modes in Band 7. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific, and simultaneous transmission exposure conditions are 0.22 W/kg, 0.72 W/kg, 0.94 W/kg, and 0.94 W/kg, respectively. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations. |
EAS Grant - Application 6f1+MFmMAZ35vpSP6iyJBg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
KRIPTO MOBILE CORPORATION 7640 NW 25TH ST STE 101 MIAMI, FL 33122 United States |
Date of Grant: 03/17/2023 Application Dated: 03/17/2023 |
| Attention: RENATO TAVARES |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2APX7K51 |
| Name of Grantee: | KRIPTO MOBILE CORPORATION |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | 4G Smart Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 1.211 | 2.5 PM | 248KGXW | |
| 22H | 824.2 - 848.8 | 0.211 | 2.5 PM | 251KG7W | |
| 22H | 826.4 - 846.6 | 0.129 | 2.5 PM | 4M16F9W | |
| 24E | 1850.2 - 1909.8 | 0.923 | 2.5 PM | 246KGXW | |
| 24E | 1850.2 - 1909.8 | 0.419 | 2.5 PM | 246KG7W | |
| 24E | 1852.4 - 1907.6 | 0.206 | 2.5 PM | 4M17F9W | |
| 24E | 1852.5 - 1907.5 | 0.18 | 2.5 PM | 4M54G7D | |
| 24E | 1852.5 - 1907.5 | 0.139 | 2.5 PM | 4M54D7W | |
| 24E | 1860.0 - 1900.0 | 0.178 | 2.5 PM | 18M1G7D | |
| 24E | 1860.0 - 1900.0 | 0.161 | 2.5 PM | 18M1D7W | |
| 27 | 1711.5 - 1753.5 | 0.169 | 2.5 PM | 2M70G7D | |
| 27 | 1711.5 - 1753.5 | 0.158 | 2.5 PM | 2M71D7W | |
| 27 | 1720.0 - 1745.0 | 0.18 | 2.5 PM | 18M1G7D | |
| 27 | 1720.0 - 1745.0 | 0.154 | 2.5 PM | 18M1D7W | |
| 27 | 2502.5 - 2567.5 | 0.196 | 2.5 PM | 4M56G7D | |
| 27 | 2502.5 - 2567.5 | 0.161 | 2.5 PM | 4M56D7W | |
| 27 | 2510.0 - 2560.0 | 0.177 | 2.5 PM | 18M0G7D | |
| 27 | 2510.0 - 2560.0 | 0.153 | 2.5 PM | 18M1D7W |
| Output power listed is ERP for operation below 1 GHz and EIRP for operation above 1 GHz. LTE supports 1.4/3/5/10/15/20 MHz BW modes in Band 2/4, 5/10/15/20 MHz BW modes in Band 7. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific, and simultaneous transmission exposure conditions are 0.22 W/kg, 0.72 W/kg, 0.94 W/kg, and 0.94 W/kg, respectively. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations. |