FCC ID 2AQ9VMARS1717XU

Wireless digital flat panel detector

by Shanghai United Imaging Healthcare Co., Ltd.

Grantee Code: 2AQ9V   Product Code: MARS1717XU
Latest application date: 2018-12-26

FCC ID Device Details

FCC ID2AQ9VMARS1717XU
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AQ9V
Product CodeMARS1717XU
Applicant BusinessShanghai United Imaging Healthcare Co., Ltd. 🇨🇳
Related Domains united-imaging.com sgs.com
Equipment ClassWireless digital flat panel detector
Test FirmCompliance Certification Services (Kunshan) Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2018-12-26
5180-5220 MHzOriginal Equipment2018-12-26

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2018-12-26PDF 2.5 MB
User Manual Metadata onlyTest Setup Photos2018-12-26PDF 2.5 MB
Internal PhotosInternal Photos2018-12-26PDF 3.4 MB
External PhotosExternal Photos2018-12-26PDF 515.5 KB
LabelID Label/Location Info2018-12-26PDF 1 MB
Test Setup PhotoTest Setup Photos2018-12-26PDF 497.1 KB
Test setup photosTest Setup Photos2018-12-26PDF 497.1 KB
SAR Test ReportTest Report2018-12-26PDF 566 KB
Test ReportTest Report2018-12-26PDF 4.8 MB
Test ReportTest Report2018-12-26PDF 2.6 MB
Test reportTest Report2018-12-26PDF 4.8 MB
Authority LetterCover Letter(s)2018-12-26PDF 33.8 KB
Authorization LetterCover Letter(s)2018-12-26PDF 33.8 KB
COVER LETTERCover Letter(s)2018-12-26PDF 55 KB
Confidentiality LetterCover Letter(s)2018-12-26PDF 125.4 KB
Declaration of ConformityCover Letter(s)2018-12-26PDF 15.3 KB
RF Exposure InfoRF Exposure Info2018-12-26PDF 566 KB
Block Diagram Metadata onlyBlock DiagramPDF 678.5 KB
Schematic Metadata onlySchematicsPDF 1.2 MB
Schematics Metadata onlySchematicsPDF 1.2 MB
Schematics Metadata onlySchematicsPDF 48.8 KB
Operational Description Metadata onlyOperational DescriptionPDF 601.8 KB
SDR software Info Metadata onlySDR Software/Security InfPDF 271.7 KB
Tune up Info Metadata onlyParts List/Tune Up InfoPDF 23.9 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 23.9 KB

Application Information

Application IDnynKLM7IrDIBzaLo0MgmKw==
Final Action Date2018-12-26
Application PurposeOriginal Equipment
Applicant FRN0027856590
ModelMARS1717XU
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWireless digital flat panel detector
Responsible PartyXin GAO, xin.gao@united-imaging.com , 02167076888
Technical ContactJeff Fang, Compliance Certification Services Inc., jeff.fang@ccsrf.com , 86-512-57355888
Non-Technical ContactMandy Liu, Compliance Certification Services Inc., mandy.liu1@sgs.com , 86-512-57355888
Test FirmJessica Chen, Compliance Certification Services (Kunshan) Inc., Jessica.chen1@sgs.com , + 86-0512-57355888
TCB EmailUSCTS.TCB@SGS.COM
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is conducted. This device is a client device containing a 2x2 Spatial Multiplexing MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. The highest reported SAR values for body, head and simultaneous transmission conditions are 0.14 W/kg, 0.11 W/kg and 0.28W/kg respectively. This device has a 20 MHz, 40 MHz bandwidth mode.

Applications

Application IDDatePurpose
nynKLM7IrDIBzaLo0MgmKw==2018-12-26Original Equipment
d932D91mF6hAi7Dk8d6vEQ==2018-12-26Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.32715CCC, MO
2422-2452 MHz0.21815CCC, MO
5180-5220 MHz0.02215ECC, MO
5190 MHz0.02115ECC, MO
5745-5825 MHz0.03315ECC, MO
5755-5795 MHz0.02315ECC, MO

Grants

TCB Grant - Application nynKLM7IrDIBzaLo0MgmKw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 12/26/2018

Application Dated: 12/26/2018
Shanghai United Imaging Healthcare Co., Ltd.
2258 Chengbei Rd., Jiading District
shanghai, 201807
China
 
Attention: Xin GAO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AQ9VMARS1717XU
Name of Grantee:  Shanghai United Imaging Healthcare Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Wireless digital flat panel detector
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.327  
CC MO 15C 2422.0  -  2452.0 0.218  

Power Output listed is conducted. This device is a client device containing a 2x2 Spatial Multiplexing MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. The highest reported SAR values for body, head and simultaneous transmission conditions are 0.14 W/kg, 0.11 W/kg and 0.28W/kg respectively. This device has a 20 MHz, 40 MHz bandwidth mode.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application nynKLM7IrDIBzaLo0MgmKw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shanghai United Imaging Healthcare Co., Ltd.
2258 Chengbei Rd., Jiading District
shanghai, 201807
China
  Date of Grant: 12/26/2018

Application Dated: 12/26/2018
 
Attention: Xin GAO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AQ9VMARS1717XU
Name of Grantee:  Shanghai United Imaging Healthcare Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Wireless digital flat panel detector
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.327  
CC MO 15C 2422.0  -  2452.0 0.218  

Power Output listed is conducted. This device is a client device containing a 2x2 Spatial Multiplexing MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. The highest reported SAR values for body, head and simultaneous transmission conditions are 0.14 W/kg, 0.11 W/kg and 0.28W/kg respectively. This device has a 20 MHz, 40 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application d932D91mF6hAi7Dk8d6vEQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 12/26/2018

Application Dated: 12/26/2018
Shanghai United Imaging Healthcare Co., Ltd.
2258 Chengbei Rd., Jiading District
shanghai, 201807
China
 
Attention: Xin GAO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AQ9VMARS1717XU
Name of Grantee:  Shanghai United Imaging Healthcare Co., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Wireless digital flat panel detector
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5220.0 0.022  
CC MO 15E 5190.0  -  5190.0 0.021  
CC MO 15E 5745.0  -  5825.0 0.033  
CC MO 15E 5755.0  -  5795.0 0.023  

Power Output listed is conducted. This device is a client device containing a 2x2 Spatial Multiplexing MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. The highest reported SAR values for body, head and simultaneous transmission conditions are 0.14 W/kg, 0.11 W/kg and 0.28W/kg respectively. This device has a 20 MHz, 40 MHz bandwidth mode.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application d932D91mF6hAi7Dk8d6vEQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shanghai United Imaging Healthcare Co., Ltd.
2258 Chengbei Rd., Jiading District
shanghai, 201807
China
  Date of Grant: 12/26/2018

Application Dated: 12/26/2018
 
Attention: Xin GAO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AQ9VMARS1717XU
Name of Grantee:  Shanghai United Imaging Healthcare Co., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Wireless digital flat panel detector
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5220.0 0.022  
CC MO 15E 5190.0  -  5190.0 0.021  
CC MO 15E 5745.0  -  5825.0 0.033  
CC MO 15E 5755.0  -  5795.0 0.023  

Power Output listed is conducted. This device is a client device containing a 2x2 Spatial Multiplexing MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. The highest reported SAR values for body, head and simultaneous transmission conditions are 0.14 W/kg, 0.11 W/kg and 0.28W/kg respectively. This device has a 20 MHz, 40 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: