FCC ID 2AQA6-H5174

Smart Thermo-Hygrometer

by Shenzhen Intellirocks Tech. Co., Ltd.

Grantee Code: 2AQA6   Product Code: H5174
Latest application date: 2020-12-08

FCC ID Device Details

FCC ID2AQA6-H5174
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AQA6
Product CodeH5174
Applicant BusinessShenzhen Intellirocks Tech. Co., Ltd. 🇨🇳
Related Domains ihoment.com
Equipment ClassSmart Thermo-Hygrometer
Test FirmGlobal United Technology Services Co. Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2020-12-08

Exhibits

DocumentTypeAvailableFile
user_manualUsers Manual2021-06-06PDF 1.6 MB
Internal_PhotosInternal Photos2021-06-06PDF 2.5 MB
External_PhotosExternal Photos2021-06-06PDF 1.9 MB
Label_and_Label_LocationID Label/Location Info2020-12-08PDF 200.9 KB
Test_Setup_PhotosTest Setup Photos2021-06-06PDF 804.7 KB
GTS202009000288-01 BT-LETest Report2020-12-08PDF 1.2 MB
GTS202009000288F01 BT-LETest Report2020-12-08PDF 1.2 MB
FCC_Short_&_Long_Term_Confidentiality_RequestCover Letter(s)2020-12-08PDF 53.1 KB
Letter_of_AuthorizationCover Letter(s)2020-12-08PDF 38.4 KB
MPE_reportRF Exposure Info2020-12-08PDF 84.7 KB
Block_Diagram Metadata onlyBlock DiagramPDF 359.6 KB
Schematic Metadata onlySchematicsPDF 370 KB
Operation_Description Metadata onlyOperational DescriptionPDF 141.1 KB

Application Information

Application IDnnBe6TCzzZrb5ojHOJzOKQ==
Final Action Date2020-12-08
Application PurposeOriginal Equipment
Applicant FRN0027657980
ModelH5174
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSmart Thermo-Hygrometer
Responsible PartyEric Pan, Manager, xiaopeng.pan@ihoment.com , 0755-21010375
Technical ContactShenzhen Intellirocks Tech. Co., Ltd., yuling.zhan@ihoment.com
Test FirmRobinson Lo, Global United Technology Services Co. Ltd., robinson.lo@gtstest.com , 86-0-755-2779-8480
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date06/06/2021
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is the maximum conducted output power. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
nnBe6TCzzZrb5ojHOJzOKQ==2020-12-08Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.001340015C

Grants

TCB Grant - Application nnBe6TCzzZrb5ojHOJzOKQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 12/08/2020

Application Dated: 12/08/2020
Shenzhen Intellirocks Tech. Co., Ltd.
No.2901-2904, 3002, Block C, Section 1, Chuangzhi
Yuncheng Building, Liuxian Avenue,Xili Community
Xili Street, Nanshan District, Shenzhen, Guangdong
China
 
Attention: Eric Pan , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AQA6-H5174
Name of Grantee:  Shenzhen Intellirocks Tech. Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Smart Thermo-Hygrometer
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00134  

Power listed is the maximum conducted output power. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

EAS Grant - Application nnBe6TCzzZrb5ojHOJzOKQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Intellirocks Tech. Co., Ltd.
No.2901-2904, 3002, Block C, Section 1, Chuangzhi Yuncheng Building, Liuxian Avenue,Xili Community
Xili Street, Nanshan District, Shenzhen, Guangdong
China
  Date of Grant: 12/08/2020

Application Dated: 12/08/2020
 
Attention: Eric Pan , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AQA6-H5174
Name of Grantee:  Shenzhen Intellirocks Tech. Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Smart Thermo-Hygrometer
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00134  

Power listed is the maximum conducted output power. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.



Mail To: