FCC ID Device Details

FCC ID2AQA9BCFE01
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AQA9
Product CodeBCFE01
Applicant BusinessBrainco Inc. 🇺🇸
Related Domains brainco.tech sgs.com
Equipment ClassWearable BCI Device
Test FirmSGS-CSTC Standards Technical Services Co., Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2018-08-31

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2018-08-31PDF 1.8 MB
Internal PhotosInternal Photos2018-08-31PDF 1.7 MB
External PhotosExternal Photos2018-08-31PDF 735.3 KB
LabelID Label/Location Info2018-08-31PDF 527.5 KB
Test Setup PhotosTest Setup Photos2018-08-31PDF 271.3 KB
SAR Test ReportRF Exposure Info2018-08-31PDF 2.9 MB
SAR test reportParts List/Tune Up Info2018-08-31PDF 256.4 KB
SAR test reportRF Exposure Info2018-08-31PDF 1.3 MB
Test ReportTest Report2018-08-31PDF 3.4 MB
Authorization LetterCover Letter(s)2018-08-31PDF 458.9 KB
Channel StatementCover Letter(s)2018-08-31PDF 357.9 KB
Confidentially LetterCover Letter(s)2018-08-31PDF 148.5 KB
InquiryCover Letter(s)2018-08-31PDF 143.5 KB
Block Diagram Metadata onlyBlock DiagramPDF 193.9 KB
Schematics Metadata onlySchematicsPDF 258.2 KB
Opeartional Description Metadata onlyOperational DescriptionPDF 14.2 KB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 338.9 KB

Application Information

Application IDYVaBI9Lrdud8txhk3oDfcw==
Final Action Date2018-08-31
Application PurposeOriginal Equipment
Applicant FRN0027658160
ModelBCFE01
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWearable BCI Device
Responsible PartyWenming Liu, Wenming.liu@brainco.tech , +1 617 945 1493
Technical ContactKeny xu, SGS-CSTC Standards Technical Services Co., Ltd, keny.xu@sgs.com , 0755-2654 4119
Non-Technical ContactJoyce shi, SGS-CSTC Standards Technical Services Co., Ltd, Joyce.Shi@sgs.com , 0755-25328662
Test FirmDerek Yang, SGS-CSTC Standards Technical Services Co., Ltd, Derek-WZ.yang@sgs.com , +86 0135 6484 8721
TCB EmailUSCTS.TCB@SGS.COM
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsPower Output listed is conducted. This device has 20MHz and 40MHz bandwidth modes. RF Exposure was evaluated for head condition. End-users must be informed regarding RF exposure compliance. The highest reported SAR for head is 0.16W/kg

Applications

Application IDDatePurpose
YVaBI9Lrdud8txhk3oDfcw==2018-08-31Original Equipment

Equipment Authorization

FrequencyOutputRules
2412-2462 MHz0.147915C
2422-2452 MHz0.039115C

Grants

TCB Grant - Application YVaBI9Lrdud8txhk3oDfcw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 08/31/2018

Application Dated: 08/31/2018
Brainco Inc.
120 Beacon St. STE 201,
Somerville, MA, 02143
Boston, MA 02143
 
Attention: Wenming Liu

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AQA9BCFE01
Name of Grantee:  Brainco Inc.
Equipment Class: Digital Transmission System
Notes: Wearable BCI Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.1479  
15C 2422.0  -  2452.0 0.0391  

Power Output listed is conducted. This device has 20MHz and 40MHz bandwidth modes. RF Exposure was evaluated for head condition. End-users must be informed regarding RF exposure compliance. The highest reported SAR for head is 0.16W/kg

EAS Grant - Application YVaBI9Lrdud8txhk3oDfcw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Brainco Inc.
120 Beacon St. STE 201, Somerville, MA, 02143
Boston, MA 02143
United States
  Date of Grant: 08/31/2018

Application Dated: 08/31/2018
 
Attention: Wenming Liu

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AQA9BCFE01
Name of Grantee:  Brainco Inc.
Equipment Class: Digital Transmission System
Notes: Wearable BCI Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.1479  
15C 2422.0  -  2452.0 0.0391  

Power Output listed is conducted. This device has 20MHz and 40MHz bandwidth modes. RF Exposure was evaluated for head condition. End-users must be informed regarding RF exposure compliance. The highest reported SAR for head is 0.16W/kg



Mail To: